Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Int J Part Ther ; 13: 100628, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39296494

RESUMO

Purpose: The purpose of this work was to reduce the severity of radiation dermatitis for breast cancer patients receiving pencil beam scanning proton therapy. The hypothesis was that eliminating proton spots (SpotDelete) in the 0.5 cm skin rind would reduce the potentially higher relative biological effectiveness (RBE) known to occur at the Bragg Peak. Patients and Methods: Our center has been using an in-house developed Python script in RayStation since 2021 to remove spots from the skin rind of breast patients. In this work, we retrospectively reviewed the on-treatment visit data from a cohort of breast patients treated with hypofractionation (16 fractions) before this technique (MinDepth) and after (SpotDelete) to acquire the physician-reported radiation dermatitis scores. We evaluated the delivered treatment plans, calculating the linear energy transfer (LET) and applying 3 variable RBE models, Carabe-Fernandez, Wedenberg, and McNamara. An α/ß of 10 was assumed for the skin. Results: In the MinDepth cohort (n = 28), grade 1, 2, and 3 dermatitis accounted for 57%, 36%, and 7% of the cases, respectively. For SpotDelete (n = 27), the incidence rate of grade 1 and 2 acute radiation dermatitis was 67% and 37%, respectively. There were 0 instances of grade 3 dermatitis observed in the SpotDelete cohort. The onset of radiation dermatitis in the SpotDelete cohort was delayed compared to MinDepth, occurring 1 week later in the course of treatment. There was no significant difference in LET or in any of the variable RBE models when analyzing the 0.5 cm skin rind between the cohorts. Conclusion: Despite the lack of correlation in LET or RBE, SpotDelete has been shown to reduce the severity and onset of radiation dermatitis. Possibly, more research into the α/ß for skin and RBE models based on skin cell lines could provide insight into the efficacy of the SpotDelete technique.

2.
Med Dosim ; 49(1): 37-40, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37989691

RESUMO

Proton therapy offers unique physical properties that make it an excellent choice for treating metastatic breast cancer, particularly when recurrent disease occurs near previously irradiated tissues. This case study demonstrates the dosimetric benefits of proton therapy in patients with metastatic breast cancer to the skin. The case consists of one patient with 5 separate areas treated with Pencil Beam Scanning (PBS) proton therapy over a period of 2 years using Monte Carlo calculation and robust optimization. The results demonstrate that proton therapy effectively spared healthy tissues while delivering the prescribed dose to the tumor. This case demonstrates the feasibility of developing effective radiation plans for skin metastases using proton therapy, highlighting its dosimetric advantages and minimal impact on nearby organs.


Assuntos
Neoplasias da Mama , Terapia com Prótons , Humanos , Feminino , Neoplasias da Mama/radioterapia , Dosagem Radioterapêutica , Terapia com Prótons/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radiometria , Método de Monte Carlo
5.
J Appl Clin Med Phys ; 23(2): e13491, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34890101

RESUMO

BACKGROUND: It is well known in proton therapy that the relative biological effectiveness (RBE) is not constant across the entire Bragg peak, with higher RBE at the distal end of the Bragg peak due to higher linear energy transfer (LET). Treatment planning systems are moving toward LET optimization to mitigate this potentially higher biological impact at a track end. However, using a simple script, proton users can begin to simulate this process by deleting spots from critical structures during optimization. In most cases, nominal target coverage and plan robustness remain satisfactory. METHODS: In our clinic, we developed a script that allows the user to delete spots in all organs at risk (OARs) of interest for one or more treatment beams. The purpose of this script is to potentially reduce side effects by eliminating Bragg peaks within OARs. The script was first used for prostate patients where spots in the rectum and sigmoid, outside of the overlap with the target, were deleted. We then began to use the script for head and neck (H&N) and breast/chestwall patients to reduce acute side effects of the skin by removing spots in a 0.5-cm skin rind. CONCLUSIONS: By utilizing a simple script for deleting spots in critical structures, we have seen excellent clinical results thus far. We have noted reduced skin reactions for nearly all H&N and breast patients.


Assuntos
Terapia com Prótons , Humanos , Transferência Linear de Energia , Masculino , Órgãos em Risco , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Eficiência Biológica Relativa
6.
J Appl Clin Med Phys ; 23(2): e13510, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34936205

RESUMO

BACKGROUND: Pencil beam scanning (PBS) proton therapy offers dosimetric advantages for several treatment sites, including head and neck (H&N). However, to achieve the optimal target coverage and robustness, these plans can be complex and time consuming to develop and optimize. Automating the treatment planning process can ensure a high-quality and standardized plan, reduce burden to the planner, and decrease time-to-treatment. We utilized in-house scripting to automate a four-field multi-field optimization (MFO) H&N planning technique. METHODS AND MATERIALS: Ten bilateral H&N patients were planned in RayStation v6 with a four-field modified-X beam configuration using MFO planning. Automation included creation of avoidance structures to control spot placement and development of standardized beams, PBS spot settings, robust optimization objectives, and patient-specific predicted planning constraints. Each patient was planned both with and without automation to evaluate differences in planning time, perceived effort and plan quality, plan robustness, and OAR sparing. RESULTS: On average, scripted plans required 3.2 h, compared to 4.3 h without the script. There was no difference in target coverage or plan robustness with or without automation. Automation significantly reduced mean dose to the oral cavity, parotids, esophagus, trachea, and larynx. Perceived effort was scaled from 1 (minimum effort) to 100 (maximum effort), and automation reduced perceived effort by 42% (p < 0.05). Two non-scripted plans required re-planning due to errors. CONCLUSIONS: Automation of this multi-beam, the MFO proton planning process reduced planning time and improved OAR sparing compared to the same planning process without scripting. Scripting generation of complex structures and planning objectives reduced burden on the planner. With most current treatment planning software, this automation is simple to implement and can standardize quality of care across all treatment planners.


Assuntos
Terapia com Prótons , Radioterapia de Intensidade Modulada , Humanos , Radiometria , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
7.
J Appl Clin Med Phys ; 20(12): 127-137, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31763759

RESUMO

PURPOSE: Our purposes are to compare the accuracy of RaySearch's analytical pencil beam (APB) and Monte Carlo (MC) algorithms for clinical proton therapy and to present clinical validation data using a novel animal tissue lung phantom. METHODS: We constructed a realistic lung phantom composed of a rack of lamb resting on a stack of rectangular natural cork slabs simulating lung tissue. The tumor was simulated using 70% lean ground lamb meat inserted in a spherical hole with diameter 40 ± 5 mm carved into the cork slabs. A single-field plan using an anterior beam and a two-field plan using two anterior-oblique beams were delivered to the phantom. Ion chamber array measurements were taken medial and distal to the tumor. Measured doses were compared with calculated RayStation APB and MC calculated doses. RESULTS: Our lung phantom enabled measurements with the MatriXX PT at multiple depths in the phantom. Using the MC calculations, the 3%/3 mm gamma index pass rates, comparing measured with calculated doses, for the distal planes were 74.5% and 85.3% for the APB and 99.1% and 92% for the MC algorithms. The measured data revealed up to 46% and 30% underdosing within the distal regions of the target volume for the single and the two field plans when APB calculations are used. These discrepancies reduced to less than 18% and 7% respectively using the MC calculations. CONCLUSIONS: RaySearch Laboratories' Monte Carlo dose calculation algorithm is superior to the pencil-beam algorithm for lung targets. Clinicians relying on the analytical pencil-beam algorithm should be aware of its pitfalls for this site and verify dose prior to delivery. We conclude that the RayStation MC algorithm is reliable and more accurate than the APB algorithm for lung targets and therefore should be used to plan proton therapy for patients with lung cancer.


Assuntos
Algoritmos , Neoplasias Pulmonares/radioterapia , Método de Monte Carlo , Órgãos em Risco/efeitos da radiação , Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador/métodos , Humanos , Terapia com Prótons/métodos , Dosagem Radioterapêutica
8.
J Appl Clin Med Phys ; 20(10): 160-171, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31541536

RESUMO

PURPOSE: The aim of this study is to validate the RayStation Monte Carlo (MC) dose algorithm using animal tissue neck phantoms and a water breast phantom. METHODS: Three anthropomorphic phantoms were used in a clinical setting to test the RayStation MC dose algorithm. We used two real animal necks that were cut to a workable shape while frozen and then thawed before being CT scanned. Secondly, we made a patient breast phantom using a breast prosthesis filled with water and placed on a flat surface. Dose distributions in the animal and breast phantoms were measured using the MatriXX PT device. RESULTS: The measured doses to the neck and breast phantoms compared exceptionally well with doses calculated by the analytical pencil beam (APB) and MC algorithms. The comparisons between APB and MC dose calculations and MatriXX PT measurements yielded an average depth difference for best gamma agreement of <1 mm for the neck phantoms. For the breast phantom better average gamma pass rates between measured and calculated dose distributions were observed for the MC than for the APB algorithms. CONCLUSIONS: The MC dose calculations are more accurate than the APB calculations for the static phantoms conditions we evaluated, especially in areas where significant inhomogeneous interfaces are traversed by the beam.


Assuntos
Algoritmos , Mama/efeitos da radiação , Cabeça/efeitos da radiação , Método de Monte Carlo , Pescoço/efeitos da radiação , Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador/métodos , Animais , Cervos , Feminino , Humanos , Neoplasias/radioterapia , Órgãos em Risco/efeitos da radiação , Terapia com Prótons , Dosagem Radioterapêutica , Ovinos
9.
Brachytherapy ; 17(1): 31-39, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-28818442

RESUMO

PURPOSE: Episcleral plaque brachytherapy (EPB) planning is conventionally based on approximations of the implant geometry with no volumetric imaging following plaque implantation. We have developed an MRI-based technique for EPB treatment planning and dose delivery verification based on the actual patient-specific geometry. METHODS AND MATERIALS: MR images of 6 patients, prescribed 85 Gy over 96 hours from Collaborative Ocular Melanoma Study-based EPB, were acquired before and after implantation. Preimplant and postimplant scans were used to generate "preplans" and "postplans", respectively. In the preplans, a digital plaque model was positioned relative to the tumor, sclera, and nerve. In the postplans, the same plaque model was positioned based on the imaged plaque. Plaque position, point doses, percentage of tumor volume receiving 85 Gy (V100), and dose to 100% of tumor volume (Dmin) were compared between preplans and postplans. All isodose plans were computed using TG-43 formalism with no heterogeneity corrections. RESULTS: Shifts and tilts of the plaque ranged from 1.4 to 8.6 mm and 1.0 to 3.8 mm, respectively. V100 was ≥97% for 4 patients. Dmin for preplans and postplans ranged from 83 to 118 Gy and 45 to 110 Gy, respectively. Point doses for tumor apex and base were all found to decrease from the preimplant to the postimplant plan, with mean differences of 16.7 ± 8.6% and 30.5 ± 11.3%, respectively. CONCLUSIONS: By implementing MRI for EPB, we eliminate reliance on approximations of the eye and tumor shape and the assumption of idealized plaque placement. With MRI, one can perform preimplant as well as postimplant imaging, facilitating EPB treatment planning based on the actual patient-specific geometry and dose-delivery verification based on the imaged plaque position.


Assuntos
Braquiterapia/métodos , Imageamento por Ressonância Magnética , Melanoma/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias Uveais/radioterapia , Humanos , Radioisótopos do Iodo/uso terapêutico , Melanoma/diagnóstico por imagem , Dosagem Radioterapêutica , Esclera , Neoplasias Uveais/diagnóstico por imagem
10.
J Appl Clin Med Phys ; 18(1): 82-89, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28291933

RESUMO

The purpose of this study was to investigate the consistency of rectal sparing using multiple periodic quality assurance computerized tomography imaging scans (QACT) obtained during the course of proton therapy for patients with prostate cancer treated with a hydrogel spacer. Forty-one low- and intermediate-risk prostate cancer patients treated with image-guided proton therapy with rectal spacer hydrogel were analyzed. To assess the reproducibility of rectal sparing with the hydrogel spacer, three to four QACTs were performed for each patient on day 1 and during weeks 1, 3, and 5 of treatment. The treatment plan was calculated on the QACT and the rectum V90%, V75%, V65%, V50%, and V40% were evaluated. For the retrospective analysis, we evaluated each QACT and compared it to the corresponding treatment planning CT (TPCT), to determine the average change in rectum DVH points. We were also interested in how many patients exceeded an upper rectum V90% threshold on a QACT. Finally, we were interested in a correlation between rectum volume and V90%. On each QACT, if the rectum V90% exceeded the upper threshold of 6%, the attending physician was notified and the patient was typically prescribed additional stool softeners or laxatives and reminded of dietary compliance. In all cases of the rectum V90% exceeding the threshold, the patient had increased gas and/or stool, compared to the TPCT. On average, the rectum V90% calculated on the QACT was 0.81% higher than that calculated on the TPCT. The average increase in V75%, V65%, V50%, and V40% on the QACT was 1.38%, 1.59%, 1.87%, and 2.17%, respectively. The rectum V90% was within ± 1% of the treatment planning dose in 71.2% of the QACTs, and within ± 5% in 93.2% of the QACTs. The 6% threshold for rectum V90% was exceeded in 7 out of 144 QACTs (4.8%), identified in 5 of the 41 patients. We evaluated the average rectum V90% across all QACTs for each of these patients, and it was found that the rectum V90% never exceeded 6%. 53% of the QACTs had a rectum volume within 5 cm3 of the TPCT volume, 68% were within 10 cm3. We found that patients who exceeded the threshold on one or more QACTs had a lower TPCT rectal volume than the overall average. By extrapolating patient anatomy from three to four QACT scans, we have shown that the use of hydrogel in conjunction with our patient diet program and use of stool softeners is effective in achieving consistent rectal sparing in patients undergoing proton therapy.


Assuntos
Tratamentos com Preservação do Órgão/métodos , Neoplasias da Próstata/radioterapia , Terapia com Prótons , Garantia da Qualidade dos Cuidados de Saúde/normas , Planejamento da Radioterapia Assistida por Computador/métodos , Reto/efeitos da radiação , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Prognóstico , Dosagem Radioterapêutica , Radioterapia Guiada por Imagem/métodos , Radioterapia de Intensidade Modulada/normas , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
11.
J Appl Clin Med Phys ; 18(2): 106-112, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28300377

RESUMO

The purpose of this study was to evaluate intrafraction prostate motion in patients treated with proton therapy and an endorectal balloon or a hydrogel spacer using orthogonal x-rays acquired before and after each treatment field. This study evaluated 10 patients (662 fields throughout treatment) treated daily with an endorectal balloon (ERB) and 16 patients (840 fields throughout treatment) treated with a hydrogel spacer (GEL) without an ERB. Patient shifts were recorded before and after each treatment field, correlated with a treatment time, using x-ray imaging and implanted fiducial alignment. For each shift, recorded in X, Y, and Z, a 3D vector was calculated to determine the positional change. There was a statistically significant difference in the mean vector shift between ERB (0.06 cm) and GEL (0.09 cm), (P < 0.001). The mean includes a large number of zero shifts, but the smallest non-zero shift recorded was 0.2 cm. The largest shifts were, on average, in the Z direction (anterior to posterior). The average Z shift was +0.02 cm for both ERB and GEL. There was no statistical difference between ERB and GEL for shifts greater than 0.3 cm (P = 0.13) or greater than 0.5 cm (P = 0.36). For treatment times between 5 and 9 min, a majority of shifts were less than 0.2 cm, 85.9% for ERB and 73.2% for GEL. There was a significant positive correlation between the vector shifts and field time for both ERB (r = 0.2, P < 0.001) and GEL (r = 0.07, P < 0.04). We have shown that prostate motion is clinically comparable between an ERB and a hydrogel spacer, and the time dependencies are similar. A large majority of shifts for both ERB and hydrogel are well within a typical robust planning margin. For GEL patients, we chose to maintain slightly larger planning margins than for ERB due to already improved rectal sparing with GEL.


Assuntos
Cateterismo/métodos , Marcadores Fiduciais , Hidrogel de Polietilenoglicol-Dimetacrilato/química , Imobilização/métodos , Neoplasias da Próstata/radioterapia , Terapia com Prótons , Planejamento da Radioterapia Assistida por Computador/métodos , Reto , Cateterismo/instrumentação , Humanos , Imobilização/instrumentação , Masculino , Órgãos em Risco/efeitos da radiação , Neoplasias da Próstata/patologia , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos
12.
Int J Radiat Oncol Biol Phys ; 95(1): 249-257, 2016 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-27084645

RESUMO

PURPOSE: To measure, in the setting of typical passively scattered proton craniospinal irradiation (CSI) treatment, the secondary neutron spectra, and use these spectra to calculate dose equivalents for both internal and external neutrons delivered via a Mevion single-room compact proton system. METHODS AND MATERIALS: Secondary neutron spectra were measured using extended-range Bonner spheres for whole brain, upper spine, and lower spine proton fields. The detector used can discriminate neutrons over the entire range of the energy spectrum encountered in proton therapy. To separately assess internally and externally generated neutrons, each of the fields was delivered with and without a phantom. Average neutron energy, total neutron fluence, and ambient dose equivalent [H* (10)] were calculated for each spectrum. Neutron dose equivalents as a function of depth were estimated by applying published neutron depth-dose data to in-air H* (10) values. RESULTS: For CSI fields, neutron spectra were similar, with a high-energy direct neutron peak, an evaporation peak, a thermal peak, and an intermediate continuum between the evaporation and thermal peaks. Neutrons in the evaporation peak made the largest contribution to dose equivalent. Internal neutrons had a very low to negligible contribution to dose equivalent compared with external neutrons, largely attributed to the measurement location being far outside the primary proton beam. Average energies ranged from 8.6 to 14.5 MeV, whereas fluences ranged from 6.91 × 10(6) to 1.04 × 10(7) n/cm(2)/Gy, and H* (10) ranged from 2.27 to 3.92 mSv/Gy. CONCLUSIONS: For CSI treatments delivered with a Mevion single-gantry proton therapy system, we found measured neutron dose was consistent with dose equivalents reported for CSI with other proton beamlines.


Assuntos
Radiação Cranioespinal/métodos , Nêutrons , Terapia com Prótons/métodos , Espalhamento de Radiação , Encéfalo/efeitos da radiação , Institutos de Câncer , Humanos , Radiometria/métodos , Dosagem Radioterapêutica , Coluna Vertebral/efeitos da radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA