Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Opt Express ; 25(11): 12935-12943, 2017 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-28786645

RESUMO

We demonstrate a simple method to measure optomechanically induced transparency (OMIT) in a Fabry-Perot based system using a trampoline resonator. In OMIT, the transmitted intensity of a weak probe beam in the presence of a strong control beam is modified via the optomechanical interaction, leading to an ultra-narrow optical resonance. To retrieve both the magnitude and the phase of the probe beam, a homodyne detection technique is typically used. We have greatly simplified this method by using a single acousto-optical modulator to create a control and two probe beams. The beat signal between the transmitted control and probe beams shows directly the typical OMIT characteristics. This method therefore demonstrates an elegant solution when a homodyne field is needed but experimentally not accessible.

2.
Opt Express ; 23(6): 8014-20, 2015 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-25837139

RESUMO

For experimental investigations of macroscopic quantum superpositions and the possible role of gravitational effects on the reduction of the corresponding quantum wave function it is beneficial to consider large mass, low frequency optomechanical systems. We report optical side-band cooling from room temperature for a 1.5×10⁻¹° kg (mode mass), low frequency side-band resolved optomechanical system based on a 5 cm long Fabry-Perot cavity. By using high-quality Bragg mirrors for both the stationary and the micromechanical mirror we are able to construct an optomechanical cavity with an optical linewidth of 23 kHz. This, together with a resonator frequency of 315 kHz, makes the system operate firmly in the side-band resolved regime. With the presented optomechanical system parameters cooling close to the ground state is possible. This brings us one step closer to creating and verifying macroscopic quantum superpositions.

3.
Rev Sci Instrum ; 83(11): 115110, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23206101

RESUMO

Ferrule-top probes are self-aligned all-optical devices obtained by fabricating a cantilever on the top of a ferruled optical fiber. This approach has been proven to provide a new platform for the realization of small footprint atomic force microscopes (AFMs) that adapt well to utilization outside specialized laboratories [D. Chavan et al., Rev. Sci. Instrum. 81, 123702 (2010); ibid. 82, 046107 (2011)]. In this paper we now show that ferrule-top cantilevers can be also used to develop nanoindenters. Our instrument combines the sensitivity of commercial AFM-based indentation with the ease-of-use of more macroscopic instrumented indenters available today on the market. Furthermore, the all-optical design allows smooth operations also in liquids, where other devices are much more limited and often provide data that are difficult to interpret. This study may pave the way to the implementation of a new generation user-friendly nanoindenters for the measurement of the stiffness of samples in material sciences and medical research.

4.
Rev Sci Instrum ; 81(12): 123702, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21198027

RESUMO

Ferrule-top cantilevers are a new generation of all-optical miniaturized devices for utilization in liquids, harsh environments, and small volumes [G. Gruca et al., Meas. Sci. Technol. 21, 094033 (2010)]. They are obtained by carving the end of a ferruled fiber in the form of a mechanical beam. Light coupled from the opposite side of the fiber allows detection of cantilever deflections. In this paper, we demonstrate that ferrule-top cantilevers can be used to develop ultra compact AFMs for contact mode imaging in air and in liquids with sensitivity comparable to that of commercial AFMs. The probes do not require any alignment procedure and are easy to handle, favoring applications also outside research laboratories.

5.
Phys Rev Lett ; 103(4): 040402, 2009 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-19659332

RESUMO

The possibility to modify the strength of the Casimir effect by tailoring the dielectric functions of the interacting surfaces is regarded as a unique opportunity in the development of micro- and nanoelectromechanical systems. In air, however, one expects that, unless noble metals are used, the electrostatic force arising from trapped charges overcomes the Casimir attraction, leaving no room for exploitation of Casimir force engineering at ambient conditions. Here we show that, in the presence of a conductive oxide, the Casimir force can be the dominant interaction even in air, and that the use of conductive oxides allows one to reduce the Casimir force up to a factor of 2 when compared to noble metals.

6.
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...