Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Sep Sci ; 45(10): 1646-1655, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35233941

RESUMO

Tolperisone and etodolac were proven to have synergistic effect for patients of acute low back pain associated with musculoskeletal spasm. In this work, a specific, highly sensitive and reproducible analytical method was developed and validated for the simultaneous determination of tolperisone and etodolac in human plasma using liquid chromatography-tandem mass spectrometric technique. Liquid-liquid extraction was optimized for sample preparation. Zorbax C8 column (3.5 µm, 50 × 4.6 mm) was used, carrying a mobile phase mixture of 10.0 mM ammonium formate:acetonitrile (40:60, v/v) pH 3.8, running in an isocratic mode. Chlorzoxazone acted as an internal standard. Sample volume of injection was 5.0 µL, and analysis was achieved within 2.5 min. Detection and quantitation were performed by electrospray ionization mass spectrometry using the multiple-reaction monitoring mode. The proposed method could determine the analytes in the range of concentration 0.5-200.0 ng mL-1 for tolperisone and 0.05-20.0 µg mL-1 for etodolac. Findings of inter- and intraday precisions were ≤12.3% with accuracy of ±5.0%. Pharmacokinetics study for the two drugs after oral administration of healthy human volunteers was achieved with the aid of application of the developed study.


Assuntos
Tolperisona , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Líquida , Etodolac , Humanos , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem/métodos
2.
Biomed Chromatogr ; 36(2): e5258, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34622957

RESUMO

Ramucirumab (RAMU) is a recently US Food and Drug Administration-approved monoclonal antibody that is included in various anticancer protocols. It has a structural complexity and high degradation risk that have a significant effect on its safety and effectiveness. The major aim of this work was to assess the degradation pattern of RAMU based on physicochemical characterization. Mechanical agitation, repeated freeze-thaw cycles, pH and temperature were the selected stress conditions to which RAMU samples were subjected. The SE-HPLC method was applied and validated to monitor the RAMU monomer along with its aggregates and/or fragments. The purity of the separated peaks together with system suitability parameters were determined through the calculation of percentage purity and percentage drop in RAMU concentration. The results were interpreted by correlating them with those of dynamic light scattering and reducing and non-reducing sodium dodecyl sulfate-polyacrylamide gel electrophoresis. Samples incubated at pH 2.0-10.0 and 37°C for up to 4 weeks were analysed, recording detection of reversed phase (RP) aggregates and low molecular weight peptide fragments. Similarly, samples under short-term storage conditions of 4 weeks at different temperatures (-20, 2-8, 25, 37 and 50°C) showed low molecular weight peptide fragments but to a lesser extent. These results highlight the alarming effect on RAMU multidose vial efficacy and safety.


Assuntos
Anticorpos Monoclonais Humanizados/análise , Anticorpos Monoclonais Humanizados/química , Cromatografia em Gel/métodos , Cromatografia Líquida de Alta Pressão/métodos , Humanos , Limite de Detecção , Modelos Lineares , Fragmentos de Peptídeos/análise , Fragmentos de Peptídeos/química , Estabilidade Proteica , Reprodutibilidade dos Testes , Ramucirumab
3.
Chem Cent J ; 12(1): 67, 2018 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-29858703

RESUMO

Paracetamol (PAR), Pseudoephedrine hydrochloride (PSE) and cetirizine dihydrochloride (CET) is a ternary mixture that composes tablets which are popular for the relief of flu in Egypt. The spectra of the drugs were overlapped and no spectrophotometric methods were reported to resolve the mixture. This research proposes four spectrophotometric methods that are efficient and require water only as a solvent. The first method was ratio subtraction-ratio difference method (RSDM) where PAR was initially removed from the mixture by ratio subtraction and determined at 292.4 nm, then PSE and CET were quantified by subtracting the amplitudes of their ratio spectra between 257.0 and 230.0 nm for PSE and between 228.0 and 257.0 nm for CET. The second method was derivative ratio spectra-zero crossing (DRZC) which was based on determining both PSE and CET from the zero-crossing points of the first and third derivative of their ratio spectra at 252.0 and 237.0 nm, respectively while PAR was determined using its first derivative at 292.4 nm. Moreover, the ternary mixture was resolved using successive derivative ratio (SDR) method where PAR, PSE and CET were determined at 310.2, 257.0 and 242.4 nm, respectively. The fourth proposed method was pure component contribution algorithm (PCCA) which was applied to quantify the drugs at their λmax. Recovery percentages for RSDM were 100.7 ± 1.890, 99.69 ± 0.8400 and 99.38 ± 1.550; DRZC were 101.8 ± 0.8600, 99.04 ± 1.200 and 98.95 ± 1.300; SDR were 101.9 ± 1.060, 99.59 ± 1.010 and 100.2 ± 0.6300; PCCA were 101.6 ± 1.240, 99.10 ± 0.5400 and 100.4 ± 1.800 for PAR, PSE and BRM; respectively. The suggested methods were effectively applied to analyze laboratory prepared mixtures and their combined dosage form.

4.
J AOAC Int ; 99(6): 1513-1521, 2016 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-27697097

RESUMO

New, simple, highly sensitive, precise, and accurate gradient reversed-phase chromatographic methods were developed using HPLC and ultra-HPLC (UPLC) systems for the determination of five components, namely thiamine, pyridoxine, cyanocobalamin, benfotiamine, and diclofenac in tablets and capsules. The methods were compared for their efficiency in the separation and determination of these five compounds using two different C18 columns (250 × 4.6 mm, 5 µm; and 100 × 4.6 mm, 2.6 µm) for HPLC and UPLC, respectively. Chromatographic separation was performed with a mobile phase containing acetonitrile and 0.025 M phosphate buffer (pH 3.5), with a gradient program and a flow rate of 1.5 and 1.0 mL/min for both methods, respectively. The methods were validated according to International Conference on Harmonization guidelines. Linearity was achieved in the range of 5.00 to 150.00 µg/mL for each of the five compounds. Ruggedness and intermediate precision were confirmed by different analysts on different columns on different days. Moreover, the components were subjected to an accelerated stability study under acidic, alkaline, and oxidative stress conditions and no interfering peaks were observed. The five compounds were efficiently separated in <20 min by HPLC, whereas for UPLC, separation was achieved in <8 min, which dramatically decreased the consumption of organic solvents.


Assuntos
Diclofenaco/análise , Tiamina/análogos & derivados , Complexo Vitamínico B/análise , Cápsulas/química , Cromatografia Líquida de Alta Pressão , Diclofenaco/química , Comprimidos/química , Tiamina/análise , Tiamina/química , Complexo Vitamínico B/química
5.
J Pharm Anal ; 4(2): 132-143, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29403875

RESUMO

Simple, accurate, sensitive and validated UV spectrophotometric and chemometric methods were developed for the determination of imidapril hydrochloride (IMD) in the presence of both its alkaline (AKN) and oxidative (OXI) degradation products and in its pharmaceutical formulation. Method A is the fourth derivative spectra (D4) which allows the determination of IMD in the presence of both AKN and OXD, in pure form and in tablets by measuring the peak amplitude at 243.0 nm. Methods B, C and D, manipulating ratio spectra, were also developed. Method B is the double divisor-ratio difference spectrophotometric one (DD-RD) by computing the difference between the amplitudes of IMD ratio spectra at 232 and 256.3 nm. Method C is the double divisor-first derivative of ratio spectra method (DD-DR1) at 243.2 nm, while method D is the mean centering of ratio spectra (MCR) at 288.0 nm. Methods A, B, C and D could successfully determine IMD in a concentration range of 4.0-32.0 µg/mL. Methods E and F are principal component regression (PCR) and partial least-squares (PLS), respectively, for the simultaneous determination of IMD in the presence of both AKN and OXI, in pure form and in its tablets. The developed methods have the advantage of simultaneous determination of the cited components without any pre-treatment. The accuracy, precision and linearity ranges of the developed methods were determined. The results obtained were statistically compared with those of a reported HPLC method, and there was no significant difference between the proposed methods and the reported method regarding both accuracy and precision.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...