Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
AJNR Am J Neuroradiol ; 37(9): 1727-32, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27231223

RESUMO

BACKGROUND AND PURPOSE: Children with sickle cell disease have low hematocrit and elevated CBF, the latter of which can be assessed with arterial spin-labeling MR imaging. Quantitative CBF values are obtained by using an estimation of the longitudinal relaxation time of blood (T1blood). Because T1blood depends on hematocrit in healthy individuals, we investigated the importance of measuring T1blood in vivo with MR imaging versus calculating it from hematocrit or assuming an adult fixed value recommended by the literature, hypothesizing that measured T1blood would be the most suited for CBF quantification in children with sickle cell disease. MATERIALS AND METHODS: Four approaches for T1blood estimation were investigated in 39 patients with sickle cell disease and subsequently used in the CBF quantification from arterial spin-labeling MR imaging. First, we used 1650 ms as recommended by the literature (T1blood-fixed); second, T1blood calculated from hematocrit measured in patients (T1blood-hematocrit); third, T1blood measured in vivo with a Look-Locker MR imaging sequence (T1blood-measured); and finally, a mean value from T1blood measured in this study in children with sickle cell disease (T1blood-sickle cell disease). Quantitative flow measurements acquired with phase-contrast MR imaging served as reference values for CBF. RESULTS: T1blood-measured (1818 ± 107 ms) was higher than the literature recommended value of 1650 ms, was significantly lower than T1blood-hematocrit (2058 ± 123 ms, P < .001), and, most interesting, did not correlate with hematocrit measurements. Use of either T1blood-measured or T1blood-sickle cell disease provided the best agreement on CBF between arterial-spin labeling and phase-contrast MR imaging reference values. CONCLUSIONS: This work advocates the use of patient-specific measured T1blood or a standardized value (1818 ms) in the quantification of CBF from arterial spin-labeling in children with SCD.


Assuntos
Anemia Falciforme/sangue , Anemia Falciforme/diagnóstico por imagem , Circulação Cerebrovascular , Adolescente , Criança , Feminino , Hematócrito , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Masculino , Valores de Referência , Marcadores de Spin
2.
NMR Biomed ; 29(4): 519-26, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26876426

RESUMO

The purpose of this study was to assess whether there was an agreement between quantitative cerebral blood flow (CBF) and arterial cerebral blood volume (CBVA) measurements by [(15)O]H2O positron emission tomography (PET) and model-free QUASAR MRI. Twelve healthy subjects were scanned within a week in separate MRI and PET imaging sessions, after which quantitative and qualitative agreement between both modalities was assessed for gray matter, white matter and whole brain region of interests (ROI). The correlation between CBF measurements obtained with both modalities was moderate to high (r(2): 0.28-0.60, P < 0.05), although QUASAR significantly underestimated CBF by 30% (P < 0.001). CBVA was moderately correlated (r(2): 0.28-0.43, P < 0.05), with QUASAR yielding values that were only 27% of the [(15)O]H2O-derived values (P < 0.001). Group-wise voxel statistics identified minor areas with significant contrast differences between [(15)O]H2O PET and QUASAR MRI, indicating similar qualitative CBVA and CBF information by both modalities. In conclusion, the results of this study demonstrate that QUASAR MRI and [(15)O]H2O PET provide similar CBF and CBVA information, but with systematic quantitative discrepancies.


Assuntos
Artérias/fisiologia , Volume Sanguíneo/fisiologia , Circulação Cerebrovascular/fisiologia , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons/métodos , Água/metabolismo , Adulto , Feminino , Hemodinâmica , Humanos , Masculino , Isótopos de Oxigênio , Adulto Jovem
3.
PLoS One ; 10(8): e0133717, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26241897

RESUMO

PURPOSE: The current study assesses the feasibility and value of crushed cerebral blood flow (CBFcrushed) and arterial transit time (ATT) estimations for large clinical imaging studies in elderly with hypertension. MATERIAL AND METHODS: Two pseudo-continuous arterial spin labeling (ASL) scans with (CBFcrushed) and without flow crushers (CBFnon-crushed) were performed in 186 elderly with hypertension, from which CBF and ATT maps were calculated. Standard flow territory maps were subdivided into proximal, intermediate and distal flow territories, based on the measured ATT. The coefficient of variation (CV) and physiological correlations with age and gender were compared between the three perfusion parameters. RESULTS: There was no difference in CV between CBFcrushed and CBFnon-crushed (15-24%, p>0.4) but the CV of ATT (4-9%) was much smaller. The total gray matter correlations with age and gender were most significant with ATT (p = .016 and p<.001 respectively), in between for CBFcrushed (p = .206 and p = .019) and least significant for CBFnon-crushed (p = .236 and p = .100). CONCLUSION: These data show the feasibility and added value of combined measurements of both crushed CBF and ATT for group analyses in elderly with hypertension. The obtained flow territories provide knowledge on vascular anatomy of elderly with hypertension and can be used in future studies to investigate regional vascular effects.


Assuntos
Artérias Cerebrais/fisiopatologia , Circulação Cerebrovascular , Hipertensão/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Marcadores de Spin , Idoso , Idoso de 80 Anos ou mais , Velocidade do Fluxo Sanguíneo , Estudos de Viabilidade , Feminino , Substância Cinzenta/irrigação sanguínea , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Técnica de Subtração
4.
Neuroimage ; 92: 182-92, 2014 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-24531046

RESUMO

Measurements of the cerebral blood flow (CBF) and cerebrovascular reactivity (CVR) provide useful information about cerebrovascular condition and regional metabolism. Pseudo-continuous arterial spin labeling (pCASL) is a promising non-invasive MRI technique to quantitatively measure the CBF, whereas additional hypercapnic pCASL measurements are currently showing great promise to quantitatively assess the CVR. However, the introduction of pCASL at a larger scale awaits further evaluation of the exact accuracy and precision compared to the gold standard. (15)O H2O positron emission tomography (PET) is currently regarded as the most accurate and precise method to quantitatively measure both CBF and CVR, though it is one of the more invasive methods as well. In this study we therefore assessed the accuracy and precision of quantitative pCASL-based CBF and CVR measurements by performing a head-to-head comparison with (15)O H2O PET, based on quantitative CBF measurements during baseline and hypercapnia. We demonstrate that pCASL CBF imaging is accurate during both baseline and hypercapnia with respect to (15)O H2O PET with a comparable precision. These results pave the way for quantitative usage of pCASL MRI in both clinical and research settings.


Assuntos
Artérias Cerebrais/diagnóstico por imagem , Artérias Cerebrais/metabolismo , Circulação Cerebrovascular , Hipercapnia/diagnóstico por imagem , Hipercapnia/metabolismo , Radioisótopos de Oxigênio/farmacocinética , Adulto , Velocidade do Fluxo Sanguíneo , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Imagem de Perfusão/métodos , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos/farmacocinética , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Marcadores de Spin , Água/metabolismo , Adulto Jovem
5.
Neuroimage ; 72: 1-9, 2013 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-23296186

RESUMO

Pharmacological magnetic resonance imaging (phMRI) maps the neurovascular response to a pharmacological challenge and is increasingly used to assess neurotransmitter systems. Here we investigated the hemodynamic response to a dopaminergic (DAergic) challenge with dextroamphetamine (dAMPH) in humans using arterial spin labeling (ASL) based phMRI. Twelve healthy male subjects aged 21.0years (±1.5) were included. We used a pseudo-continuous ASL sequence (40min) to quantify cerebral blood flow (CBF) and started dAMPH infusion (0.3mg/kg) after 10min. On another day, we measured baseline dopamine D2/3 receptor availability with [(123)I]IBZM single photon emission computed tomography (SPECT). Baseline measures on mood and impulsivity and subjective behavioral responses to dAMPH were obtained. CBF response was corrected for cardiovascular effects using an occipital cortex mask for internal reference. Corrected CBF (sCBF) was analyzed using ROI-based and voxel-based analysis, in addition to independent component analysis (ICA). CBF data was correlated to D2/3 receptor availability and behavioral measures. Subjects reported experiencing euphoria following dAMPH administration. In the striatum sCBF significantly increased, as demonstrated by all three analysis methods. Voxel-based analysis and ICA also showed increased sCBF in the thalamus, anterior cingulate and cerebellum. Decreased sCBF was observed in several cortical areas, the posterior cingulated and paracingulate cortex. Apart from one ICA component, no correlations were found with sCBF changes and D2/3 receptor availability and behavioral measures. Our observations are in line with literature and provide further evidence that ASL-based phMRI with dAMPH is a promising technique to assess DAergic function in human subjects.


Assuntos
Mapeamento Encefálico/métodos , Encéfalo/irrigação sanguínea , Estimulantes do Sistema Nervoso Central/farmacologia , Dextroanfetamina/farmacologia , Dopamina/metabolismo , Imageamento por Ressonância Magnética/métodos , Encéfalo/efeitos dos fármacos , Circulação Cerebrovascular/efeitos dos fármacos , Circulação Cerebrovascular/fisiologia , Hemodinâmica , Humanos , Masculino , Receptores de Dopamina D2/metabolismo , Receptores de Dopamina D3/metabolismo , Marcadores de Spin , Tomografia Computadorizada de Emissão de Fóton Único , Adulto Jovem
6.
AJNR Am J Neuroradiol ; 33(2): 329-35, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22081677

RESUMO

BACKGROUND AND PURPOSE: Therapeutic carotid occlusion is an established technique for treatment of large and giant aneurysms of the ICA, in patients with synchronous venous filling on angiography during BTO. Concern remains that hemodynamic alterations after permanent occlusion will predispose the patient to new ischemic injury in the ipsilateral hemisphere. The purpose of this study was to assess whether BTO with synchronous venous filling is associated with normal CBF long term after carotid sacrifice. MATERIALS AND METHODS: Eleven patients were included (all women; mean age, 50.5 years; mean follow-up, 38.5 months). ASL with single and multiple TIs was used to assess CBF and its temporal characteristics. Selective ASL was used to assess actual territorial contribution of the ICA and BA. Collateral flow via the AcomA or PcomA or both was determined by time-resolved 3D PCMR. Paired t tests were used to compare CBF and timing parameters between hemispheres. RESULTS: Absolute CBF values were within the normal range. There was no significant CBF difference between hemispheres ipsilateral and contralateral to carotid sacrifice (49.4 ± 11.2 versus 50.1 ± 10.1 mL/100 g/min). Arterial arrival time and trailing edge time were significantly prolonged on the occlusion side (816 ± 119 ms versus 741 ± 103 ms, P = .001; and 1765 ± 179 ms versus 1646 ± 190 ms, P < .001). Two patients had collateral flow through the AcomA only and were found to have increased timing parameters compared with 9 patients with mixed collateral flow through both the AcomA and PcomA. CONCLUSIONS: In this small study, patients with synchronous venous filling during BTO had normal CBF long term after therapeutic ICA occlusion.


Assuntos
Oclusão com Balão , Encéfalo/irrigação sanguínea , Artéria Carótida Interna , Circulação Cerebrovascular , Aneurisma Intracraniano/terapia , Angiografia por Ressonância Magnética , Adulto , Idoso , Feminino , Humanos , Pessoa de Meia-Idade , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA