Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 24(3)2024 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-38339484

RESUMO

Postural deformities often manifest themselves in a sagittal imbalance and an asymmetric morphology of the torso. As a novel topographic method, torsobarography assesses the morphology of the back by analysing pressure distribution along the torso in a lying position. At torsobarography's core is a capacitive pressure sensor array. To evaluate its feasibility as a diagnostic tool, the reproducibility of the system and extracted anatomical associated parameters were evaluated on 40 subjects. Landmarks and reference distances were identified within the pressure images. The examined parameters describe the shape of the spine, various structures of the trunk symmetry, such as the scapulae, and the pelvic posture. The results showed that the localisation of the different structures performs with a good (ICC > 0.75) to excellent (ICC > 0.90) reliability. In particular, parameters for approximating the sagittal spine shape were reliably reproduced (ICC > 0.83). Lower reliability was observed for asymmetry parameters, which can be related to the low variability within the subject group. Nonetheless, the reliability levels of selected parameters are comparable to commercial systems. This study demonstrates the substantial potential of torsobarography at its current stage for reliable posture analysis and may pave the way as an early detection system for postural deformities.


Assuntos
Postura , Coluna Vertebral , Humanos , Reprodutibilidade dos Testes , Variações Dependentes do Observador , Pelve
2.
Sensors (Basel) ; 23(14)2023 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-37514793

RESUMO

The soft tissues of residual limb amputees are subject to large volume fluctuations over the course of a day. Volume fluctuations in residual limbs can lead to local pressure marks, causing discomfort, pain and rejection of prostheses. Existing methods for measuring interface stress encounter several limitations. A major problem is that the measurement instrumentation is applied in the sensitive interface between the prosthesis and residual limb. This paper presents the principle investigation of a non-intrusive technique to evaluate the fit of orthopaedic prosthesis sockets in transfemoral amputees based on experimentally obtained vibrational data. The proposed approach is based on changes in the dynamical behaviour detectable at the outer surface of prostheses; thus, the described interface is not affected. Based on the experimental investigations shown and the derived results, it can be concluded that structural dynamic measurements are a promising non-intrusive technique to evaluate the fit of orthopaedic prosthesis sockets in transfemoral amputee patients. The obtained resonance frequency changes of 2% are a good indicator of successful applicabilityas these changes can be detected without the need for complex measurement devices.


Assuntos
Amputados , Membros Artificiais , Ortopedia , Humanos , Desenho de Prótese , Implantação de Prótese , Cotos de Amputação
3.
Brain Sci ; 11(8)2021 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-34439668

RESUMO

In multiple sclerosis (MS), gait impairment is one of the most prominent symptoms. For a sensitive assessment of pathological gait patterns, a comprehensive analysis and processing of several gait analysis systems is necessary. The objective of this work was to determine the best diagnostic gait system (DIERS pedogait, GAITRite system, and Mobility Lab) using six machine learning algorithms for the differentiation between people with multiple sclerosis (pwMS) and healthy controls, between pwMS with and without fatigue and between pwMS with mild and moderate impairment. The data of the three gait systems were assessed on 54 pwMS and 38 healthy controls. Gaussian Naive Bayes, Decision Tree, k-Nearest Neighbor, and Support Vector Machines (SVM) with linear, radial basis function (rbf) and polynomial kernel were applied for the detection of subtle walking changes. The best performance for a healthy-sick classification was achieved on the DIERS data with a SVM rbf kernel (κ = 0.49 ± 0.11). For differentiating between pwMS with mild and moderate disability, the GAITRite data with the SVM linear kernel (κ = 0.61 ± 0.06) showed the best performance. This study demonstrates that machine learning methods are suitable for identifying pathologic gait patterns in early MS.

4.
Z Orthop Unfall ; 158(3): 318-332, 2020 Jun.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-31404938

RESUMO

BACKGROUND: The FED method (Fixation, Elongation, Derotation) is a treatment method approach to Patients with scoliosis. The FED method is especially established in Spain and Poland, whereby in Germany it is less well-known. Nevertheless the FED method is within the scope of a research project (Project Number: 19200 BR/3). The purpose of the paper is to characterize the FED method and to highlight the specificities in contrast to the Schroth method, which is international established and especially in Germany. METHODS: This systematic literature research was conducted in Nov 2017-Jan 2018. Therefore common medical and physiotherapeutic databases were used. Furthermore there was a hand search in selected scientific journals. Only a small number of relevant references were identified. That is why the respective authors were asked to provide the full-texts of their papers and to recommend further references. RESULTS: A total of 378 references were identified. After removing duplicates and the content-related selection, 19 references were deemed to be relevant. Based on the analysis of this relevant literature, the FED method was comprehensively characterized. First of all the general structure of the FED method and the scientific evidence for its effectiveness was described. And as a result of the literature research, the operating principles of the FED method were pointed out. Then these operating principles were discussed in comparison with the Schroth method. The Schroth method based on sensomotoric and kinesthetic principles and the correction of the pathologic posture was performed by selective muscle activation and breathing-pattern. Thus, the posture correction will be performed by the patients (auto correction). Compared to the Schroth method, the FED method implements the posture correction by the FED-device. This correction is influenced by mechanical forces with a comparatively high strength and intensity. The repetitive mechanical correction stimulates the sensomotoric system. And due to trophic/biochemical adaptations, the physiological bone growth will be stimulated. CONCLUSION: In total the authors want to clarify, that both treatment methods (Schroth method, FED method) supposed to be applied in consideration of the preconditions of the patients and the pursue of the different treatment goals. Thus, the implementation of treatment methods should be used according to the individual treatment demand and on different stages in the treatment process.


Assuntos
Modalidades de Fisioterapia , Escoliose , Terapia por Exercício , Alemanha , Humanos , Polônia , Postura , Escoliose/terapia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...