Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eur J Radiol ; 80(3): e351-5, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21156342

RESUMO

PURPOSE: Accurate stenosis quantification in the carotid arteries is of great clinical importance. We aimed to compare the diagnostic accuracy of multi-slice computed tomography angiography (CTA) to digital subtraction angiography (DSA) for the detection and grading of atherosclerotic lesions involving the supraaortic arteries. MATERIALS AND METHODS: We retrospectively analyzed 30 patients (10 women; mean age, 67 years). CTA was performed after administration of 100 ml Ultravist 370 (Bayer Schering, Germany), at a flow of 5 ml/s, using a Philips Brilliance 16MDCT scanner (Philips, Best, Netherland) at a collimation of 16 mm×0.75 mm prior to DSA. The supraaortic arteries were divided into 17 segments, and, within each segment, the presence and severity of stenotic or occlusive lesions was determined, based on a four-point scale (0-49%, 50-69%, 70-99%, occlusion), by four independent readers using the NASCET criteria. Sensitivity and specificity of MDCT was calculated for the detection of moderate (50-69%) versus significant stenoses (70-99%) and occlusion. RESULTS: There were 291 segments assessed with both methods. Thirteen lesions were "not assessable" on CTA. DSA identified 53 significant lesions, and CTA 56 significant lesions. With regard to significant lesions, CTA overrated six lesions and underestimated six lesions, resulting in a sensitivity, specificity, and accuracy of 86.4%, 97.6%, and 95.9%, respectively. For the detection of stenoses greater than 50%, sensitivity, specificity, and accuracy were 90.2%, 95.8%, and 94.8%, respectively. CONCLUSIONS: Compared to DSA, CTA shows high accuracy in the detection and grading of lesions involving the supraaortic arteries enabling its use in the detection and treatment planning for stenoses of the supraaortic vessels.


Assuntos
Angiografia Digital/métodos , Estenose da Valva Aórtica/diagnóstico por imagem , Aortografia/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
Rofo ; 173(12): 1118-25, 2001 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-11740673

RESUMO

PURPOSE: We describe the implementation of quality improvement measures in a quality management system. METHODS: With questionnaires for radiologists and patients, we investigated the relations between patient preparation and diagnostic quality serving the main purpose, to improve diagnostic quality with the help of more detailed patient information (e.g., changing preparation sheets and handling out "peri-med" information sheets to the patients). Furthermore, a comparative data ascertainment at other institutes was integrated. RESULTS: For the group of outpatients, increasing process quality (patient information) and outcome (diagnostic quality) could be achieved. Taking aspects of quality costs into consideration, a decrease in costs due to failures was achieved. CONCLUSION: More detailed patient information has positive effects on diagnostic quality of the double contrast (barium) enema.


Assuntos
Sulfato de Bário , Colo/diagnóstico por imagem , Meios de Contraste , Gestão da Qualidade Total , Atitude do Pessoal de Saúde , Doenças do Colo/diagnóstico por imagem , Colonoscopia , Análise Custo-Benefício , Feminino , Alemanha , Humanos , Masculino , Cooperação do Paciente , Educação de Pacientes como Assunto , Radiografia , Inquéritos e Questionários , Irrigação Terapêutica , Gestão da Qualidade Total/economia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA