Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Aliment Pharmacol Ther ; 42(9): 1122-30, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26314389

RESUMO

BACKGROUND: Monitoring of the treatment response in eosinophilic oesophagitis (EoE) requires structured endoscopical and histological examination of the oesophagus. Less invasive methods would be highly desirable. AIM: To evaluate the utility of several EoE-associated blood and serum markers in order to non-invasively monitor the response to treatment with swallowed topical corticosteroids in adult EoE patients. METHODS: In a randomised, controlled double-blind trial blood samples of EoE patients (n = 69) were collected at baseline and after 14 days of treatment with budesonide (n = 51) or placebo (n = 18) respectively. Absolute blood eosinophil count (AEC) as well as serum levels of CCL-17, CCL-18, CCL-26, eosinophil-cationic-protein (ECP) and mast cell tryptase (MCT) were determined and correlated with oesophageal eosinophil density and with symptom and endoscopy scores. RESULTS: Histological remission, defined as mean number of <16 eos/mm(2) hpf at end-of-treatment, was achieved in 98% of the budesonide and 0% of the placebo recipients. AEC [380.2 vs. 214.7/mm(3) (P = 0.0001)], serum-CCL-17 [294.3 vs. 257.9 pg/mL (P = 0.0019)], -CCL-26 [26.7 vs. 16.2 pg/mL (P = 0.0058)], -ECP [45.5 ± 44.7 vs. 27.5 ± 25.0 µg/L (P = 0.0016)] and -MCT [5.3 ± 2.9 vs. 4.5 ± 2.6 µg/L (P = 0.0019)] significantly decreased under budesonide but not under placebo. AEC significantly correlated with oesophageal eosinophil density before (r = 0.28, P = 0.0236) and after (r = 0.42, P = 0.0004) budesonide treatment. In ROC-AUC analyses post-treatment values of AEC were significantly associated with histological remission (ROC-AUC 0.754; 95% CI: 0.617-0.891; P = 0.0003). CONCLUSIONS: The budesonide-induced treatment response in EoE is mirrored by several blood and serum markers, and the absolute blood eosinophil count is the most valuable as it shows correlation with the oesophageal eosinophil density.


Assuntos
Biomarcadores/sangue , Budesonida/uso terapêutico , Esofagite Eosinofílica/sangue , Esofagite Eosinofílica/tratamento farmacológico , Eosinófilos , Glucocorticoides/uso terapêutico , Adulto , Quimiocinas CC/sangue , Método Duplo-Cego , Monitoramento de Medicamentos , Proteína Catiônica de Eosinófilo/sangue , Esofagite Eosinofílica/diagnóstico , Feminino , Humanos , Contagem de Leucócitos , Masculino , Pessoa de Meia-Idade , Curva ROC , Indução de Remissão , Triptases/sangue
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA