Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Thromb Res ; 240: 109045, 2024 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-38834002

RESUMO

INTRODUCTION: Thrombin generation assays (TGAs) assess the overall functionality of the hemostatic system and thereby provide a reflection of the hemostatic capacity of patients with disorders in this system. Currently, four (semi-)automated TGA platforms are available: the Calibrated Automated Thrombogram, Nijmegen Hemostasis Assay, ST Genesia and Ceveron s100. In this study, we compared their performance for detecting patients with congenital single coagulation factor deficiencies. MATERIALS AND METHODS: Pooled patient samples, healthy control samples and normal pooled plasma were tested on all four platforms, using the available reagents that vary in tissue factor and phospholipid concentrations. The TGA parameters selected for analysis were peak height and thrombin potential. Results were normalized by using the calculated mean of healthy controls and a correction for between-run variation. Outcomes were presented as relative values, with the mean of healthy controls standardized to 100 %. RESULTS: Across all platforms and reagents used, thrombin potentials and peak heights of samples with coagulation factor deficiencies were lower than those of healthy controls. Reagents designed for bleeding tendencies yielded the lowest values on all platforms (relative median peak height 19-32 %, relative median thrombin potential 19-45 %). Samples representing more severe coagulation factor deficiencies generally exhibited lower relative peak heights and thrombin potentials. CONCLUSIONS: Thrombin generation assays prove effective in differentiating single coagulation factor deficient samples from healthy controls, with modest discrepancies observed between the platforms. Reagents designed for assessing bleeding tendencies, featuring the lowest tissue factor and phospholipid concentrations, emerged as the most suitable option for detecting coagulation factor deficiencies.

3.
Thromb Res ; 234: 51-58, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38159324

RESUMO

BACKGROUND: Patients with severe coronavirus disease 2019 (COVID-19) present with persisting hypercoagulability, hypofibrinolysis and prolonged clot initiation as measured with viscoelastic assays. The objective of this study was to investigate the trajectories of traditional assays of hemostasis, routine and tissue plasminogen activator (tPA) rotational thromboelastometry (ROTEM) in COVID-19 patients and to study their association with mortality. METHODS: Patients enrolled within the Maastricht Intensive Care COVID (MaastrICCht) cohort were included. Traditional assays of hemostasis (prothrombin time; PT, fibrinogen and D-dimer) were measured daily and ROTEM EXTEM, FIBTEM and tPA assays were performed weekly. Trajectories of these biomarkers were analyzed over time for survivors and non-survivors using linear mixed-effects models. Additional Fine and Gray competing risk survival analysis was performed for the first available measurement after intubation. RESULTS: Of the 138 included patients, 57 (41 %) died in the intensive care unit (ICU). Over 450, 400 and 1900 individual measurements were available for analysis of routine, tPA ROTEM and traditional assays of hemostasis, respectively, with a median [IQR] follow-up of 15 [8-24] days. Non-survivors on average had prolonged CT (clotting time) and increased fibrinogen compared to survivors. MCF (maximum clot firmness), LOT (lysis onset time), LT (lysis time) and PT measurements increased more over time in non-survivors compared to survivors. Associations persisted after adjustment for demographics and disease severity. EXTEM and FIBTEM CT at intubation were associated with increased 45-day ICU mortality. CONCLUSIONS: ROTEM measurements demonstrate a further increase of hypercoagulability and (hypo)fibrinolysis parameters in non-survivors throughout ICU admission. Furthermore, prolonged CT at intubation was associated with higher 45-day ICU mortality.


Assuntos
COVID-19 , Trombofilia , Humanos , Tromboelastografia , Ativador de Plasminogênio Tecidual , Testes de Coagulação Sanguínea , Fibrinogênio , Biomarcadores , Cuidados Críticos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...