Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Exp Orthop ; 11(3): e12092, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39119048

RESUMO

Purpose: Radial head arthroplasty (RHA) reestablishes elbow stability after complex radial head fracture, but complication rates are high, possibly due to inappropriate implant sizing. Knowledge of impact of radial head implant diameter on elbow kinematics is limited and warranted. This study evaluated elbow kinematics of different radial head implant diameters after RHA using dynamic radiostereometric analysis (dRSA). Methods: Eight human donor arms were examined with dRSA during elbow flexion with the forearm in unloaded neutral position, and in supinated- and pronated position without and with 10N either varus or valgus load, respectively. Elbow kinematics were examined before and after RHA with head diameters of anatomical size, -2 mm (undersized), and +2 mm (oversized). The ligaments were kept intact by use of step-cut humerus osteotomy for repeated RHA exchange. Bone models were obtained from CT, and by AutoRSA software bone models were matched with dRSA recordings. The elbow kinematics were described using anatomical coordinate systems. Results: Compared to the native radial head during elbow flexion, the anatomical sized RHA shifted 2.0 mm in ulnar direction during unloaded pronated forearm position. The undersized RHA shifted 1.5 mm in posterior direction and 2.1 mm in ulnar direction during unloaded pronated forearm position and increased the varus angle by 2.4° during supinated loaded forearm position. The oversized RHA shifted 1.6 mm in radial direction during loaded supinated forearm position. Conclusions: The anatomically sized RHA should be preferred as it maintained native elbow kinematics the best. The kinematic changes with oversized and undersized RHA diameters were small, suggesting forgiveness for the RHA diameter size. Level of Evidence: Level III.

2.
J Orthop Res ; 38(3): 510-522, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31595550

RESUMO

Complex radial head fracture and elbow instability can be treated with radial head arthroplasty. Good clinical results have been described after this surgical treatment. However, the revision and complication rate reported in the literature is concerning. This might be due to altered kinematics after radial head arthroplasty. Eight human native elbows were examined with dynamic radiostereometric analysis and compared with a radial head arthroplasty. Translations of the radial head in the x-, y-, and z-directions relative to the humerus and the ulna were measured. The radiocapitellar joint pressure was measured using a pressure sensor. The tension within the interosseous membrane was measured using a custom-made strain gauge. After radial head arthroplasty, the radial head was displaced approximately 1.8 mm medially and 1.4 mm distally at the starting point. During unloaded flexion motion the difference in all translations between the native radial head and the radial head arthroplasty was less than 1 mm (95% confidence interval [CI] ± 0.5 mm) (p = 0.001). With loading the difference was less than 1.5 mm (95% CI ± 1.5 mm) (p = 0.001). The mean difference in radiocapitellar joint contact pressure was less than 0.30 MPa (95% CI ± 0.40 MPa) (p = 0.001) during unloaded flexion motion. There were only submillimetre kinematic changes and small changes in joint pressure and interosseous membrane tension after the insertion of a radial head arthroplasty in an experimental setting. © 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 38:510-522, 2020.


Assuntos
Artroplastia/métodos , Articulação do Cotovelo/fisiologia , Membrana Interóssea/patologia , Fraturas do Rádio/cirurgia , Rádio (Anatomia)/fisiologia , Rádio (Anatomia)/cirurgia , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Dinamarca , Articulação do Cotovelo/cirurgia , Feminino , Humanos , Úmero/cirurgia , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Pressão , Estresse Mecânico , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA