Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Nucl Med ; 64(9): 1456-1462, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37290797

RESUMO

Bone marrow suppression is a common side effect after [177Lu]Lu-DOTATATE treatment of neuroendocrine neoplasms. Neuroendocrine neoplasms share expression of somatostatin receptor type 2 with CD34-positive hematopoietic progenitor cells, potentially leading to active uptake in the radiosensitive red marrow region where these cells are located. This study aimed to identify and quantify specific red marrow uptake using SPECT/CT images collected after the first treatment cycle. Methods: Seventeen patients diagnosed with neuroendocrine neoplasms were treated with [177Lu]Lu-DOTATATE. Seven of them had confirmed bone metastases. After the first treatment cycle, each patient went through 4 SPECT/CT imaging sessions 4, 24, 48, and 168 h after administration. Monte Carlo-based reconstructions were used to quantify activity concentrations in tumors and multiple skeletal sites presumed to house red marrow: the T9-L5 vertebrae and the ilium portion of the hip bones. The activity concentration from the descending aorta was used as input in a compartment model intended to establish a pure red marrow biodistribution by separating the nonspecific blood-based contribution from the specific activity concentration in red marrow. The biodistributions from the compartment model were used to perform red marrow dosimetry at each skeletal site. Results: Increased uptake of [177Lu]Lu-DOTATATE was observed in the T9-L5 vertebrae and hip bones in all 17 patients compared with activity concentrations in the aorta. The mean specific red marrow uptake was 49% (range, 0%-93%) higher than the nonspecific uptake. The median (±SD) total absorbed dose to the red marrow was 0.056 ± 0.023 Gy/GBq and 0.043 ± 0.022 Gy/GBq for the mean of all vertebrae and hip bones, respectively. The patients with bone metastases had an absorbed dose of 0.085 ± 0.046 Gy/GBq and 0.069 ± 0.033 Gy/GBq for the vertebrae and hip bones, respectively. The red marrow elimination phase was statistically slower in patients with fast tumor elimination, which is in line with transferrin transport of 177Lu back to the red marrow. Conclusion: Our results suggest that specific red marrow uptake of [177Lu]Lu-DOTATATE is in line with observations of somatostatin receptor type 2-expressing hematopoietic progenitor cells within the bone marrow. Blood-based dosimetry methods fail to account for the prolonged elimination of specific uptake and underestimate the absorbed dose to red marrow.


Assuntos
Neoplasias Ósseas , Tumores Neuroendócrinos , Compostos Organometálicos , Humanos , Medula Óssea/metabolismo , Octreotida/efeitos adversos , Octreotida/metabolismo , Compostos Organometálicos/efeitos adversos , Distribuição Tecidual , Compostos Radiofarmacêuticos/uso terapêutico , Tumores Neuroendócrinos/metabolismo
2.
EJNMMI Phys ; 9(1): 65, 2022 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-36153386

RESUMO

BACKGROUND: Based on theoretical and preclinical results, terbium-161 may be a valid alternative to lutetium-177 and yttrium-90 in radionuclide therapies. The large low-energy electron emission from terbium-161 is a favorable feature in the treatment of disseminated disease, but its impact on the radiosensitive bone marrow needs to be evaluated. Using voxel-based skeletal dosimetry models in which active bone marrow is defined as regions containing stem cells and progenitor cells of the hematopoietic lineage, we generated S-values (absorbed dose per decay) for terbium-161 and evaluated its distribution-dependence in bone marrow cavities. METHODS: S-values in the active bone marrow were calculated for terbium-161, lutetium-177, and yttrium-90 irradiation using two (male/female) image-based bone marrow dosimetry models. The radionuclides were distributed to one of the three structures that define the spongiosa bone region in the skeletal models: (i) active bone marrow, (ii) inactive bone marrow, or (iii) surface or whole volume of the trabecular bone. Decay data from ICRP 107 were combined with specific absorbed fractions to calculate S-values for 13 skeletal sites. To increase the utility, the skeletal site-specific S-values were averaged to produce whole-body average S-values and spongiosa average S-values. RESULTS: For yttrium-90, the high-energy ß particles irradiate the active marrow regardless of the source compartment, consistently generating the highest S-values (65-90% higher). Between terbium-161 and lutetium-177, the largest differences in S-values were with an active marrow source (50%), such as self-irradiation, due to the contribution of the short-ranged conversion and Auger electrons from terbium-161. Their influence decreased as the source moved to inactive marrow or the surface or volume of the trabecular bone, reducing the S-values and the differences between terbium-161 and lutetium-177 (15-35%). CONCLUSION: The S-values of terbium-161 for active bone marrow and, consequently, the bone marrow toxicity profile were more dependent on the radionuclide distribution within the bone marrow cavity than the S-values of lutetium-177 and yttrium-90. This effect was attributed to the considerable low-energy electron emission of terbium-161. Therefore, it will be critical to investigate the bone marrow distribution of a particular radiopharmaceutical for accurate estimation of the active bone marrow dose.

3.
Cancers (Basel) ; 13(9)2021 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-33921956

RESUMO

The aim of this study was to analyze the required absorbed doses to detectable metastases (Dreq) when using radionuclides with prostate specific membrane antigen (PSMA)-targeting radioligands to achieve a high probability for metastatic control. The Monte Carlo based analysis was performed for the clinically-used radionuclides yttrium-90, iodine-131, lutetium-177, and actinium-225, and the newly-proposed low-energy electron emitter terbium-161. It was demonstrated that metastatic formation rate highly influenced the metastatic distribution. Lower values generated few large detectable metastases, as in the case with oligo metastases, while high values generated a distribution of multiple small detectable metastases, as observed in patients with diffused visualized metastases. With equal number of detectable metastases, the total metastatic volume burden was 4-6 times higher in the oligo metastatic scenario compared to the diffusely visualized scenario. The Dreq was around 30% higher for the situations with 20 detectable metastases compared to one detectable metastasis. The Dreq for iodine-131 and yttrium-90 was high (920-3300 Gy). The Dreq for lutetium-177 was between 560 and 780 Gy and considerably lower Dreq were obtained for actinium-225 and terbium-161, with 240-330 Gy and 210-280 Gy, respectively. In conclusion, the simulations demonstrated that terbium-161 has the potential for being a more effective targeted radionuclide therapy for metastases using PSMA ligands.

4.
Adv Radiat Oncol ; 3(3): 439-446, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30202811

RESUMO

PURPOSE: Radioembolization is an alternative palliative treatment for hepatocellular carcinoma. Here, we examine the uptake differences between tumor tissue phenotypes and present a cross-section of the absorbed dose throughout a liver tissue specimen. METHODS AND MATERIALS: A patient with hepatocellular carcinoma was treated with 90Y radioembolization followed by liver tissue resection. Gamma camera images and autoradiographs were collected and biopsy tissue samples were analyzed using a gamma well counter and light microscopy. RESULTS: An analysis of 25 punched biopsy tissue samples identified 4 tissue regions: Normal tissue, viable tumor tissue with and without infarcted areas, and tumor areas with postnecrotic scar tissue. Autoradiography and biopsy tissue sample measurements showed large dose differences between viable and postnecrotic tumor tissue (159 Gy vs 23 Gy). CONCLUSIONS: Radioembolization of 90 yttrium with resin microspheres produces heterogeneous-absorbed dose distributions in the treatment of unifocal hepatic malignancies that could not be accurately determined with current gamma camera imaging techniques.

5.
EJNMMI Phys ; 3(1): 21, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27654452

RESUMO

BACKGROUND: (177)Lu-DOTATATE is a valuable treatment option for patients with advanced neuroendocrine tumours overexpressing somatostatin receptors. Though well tolerated in general, bone marrow toxicity can, besides renal exposure, become dose limiting and affect the ability to sustain future therapies. The aim of this study was to develop a novel planar image-based method for bone marrow dosimetry and evaluate its correlation with haematological toxicity during (177)Lu-DOTATATE treatment. In this study, 46 patients with advanced neuroendocrine tumours were treated with 7.2 GBq (3.5-8.3 GBq) of (177)Lu-DOTATATE on two to five occasions. Planar gamma camera images were acquired at 2, 24, 48 and 168 h post-injection. Whole-body regions of interest were created in the images, and a threshold-based segmentation algorithm was applied to separate the uptake of (177)Lu-DOTATATE into high and low uptake compartments. The conjugate view method was used to quantify the activity, the accumulated activity was calculated and the absorbed dose to the bone marrow was estimated according to the MIRD scheme. Patients were monitored for haematological toxicity based on haemoglobin (Hb), white blood cell (WBC) and platelet (PLT) counts every other week during the treatment period. RESULTS: The mean absorbed dose to the bone marrow was estimated to 0.20 Gy (0.11-0.37 Gy) per 7.4 GBq of (177)Lu-DOTATATE, and the mean dose per fraction correlated with a decrease in Hb (p = 0.01), WBC (p < 0.01) and PLT (p < 0.01) counts. The total mean absorbed dose to the bone marrow was 0.64 Gy (0.30-1.5 Gy) per 24 GBq (8.2-37 GBq) of (177)Lu-DOTATATE and also correlated with a decrease in Hb (p < 0.01), WBC (p = 0.01) and PLT (p < 0.01) counts. CONCLUSIONS: The planar image-based method developed in this study resulted in similar absorbed doses to the bone marrow as reported in earlier studies with blood-based bone marrow dosimetry. The results correlated with haematological toxicity, making it a promising method for estimating bone marrow doses in (177)Lu-DOTATATE treatment without the need for blood and urine sampling.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...