Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Clin Pathol ; 76(3): 194-201, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34620610

RESUMO

AIMS: Recently, a new automated digital cell imaging analyser (Sysmex CellaVision DC-1), intended for use in low-volume and small satellite laboratories, has become available. The purpose of this study was to compare the performance of the DC-1 with the Sysmex DI-60 system and the gold standard, manual microscopy. METHODS: White blood cell (WBC) differential counts in 100 normal and 100 abnormal peripheral blood smears were compared between the DC-1, the DI-60 and manual microscopy to establish accuracy, within-run imprecision, clinical sensitivity and specificity. Moreover, the agreement between precharacterisation and postcharacterisation of red blood cell (RBC) morphological abnormalities was determined for the DC-1. RESULTS: WBC preclassification and postclassification results of the DC-1 showed good correlation compared with DI-60 results and manual microscopy. In addition, the within-run SD of the DC-1 was below 1 for all five major WBC classes, indicating good reproducibility. Clinical sensitivity and specificity were, respectively, 96.7%/95.9% compared with the DI-60% and 96.6%/95.3% compared with manual microscopy. The overall agreement on RBC morphology between the precharacterisation and postcharacterisation results ranged from 49% (poikilocytosis) to 100% (hypochromasia, microcytosis and macrocytosis). CONCLUSIONS: The DC-1 has proven to be an accurate digital cell imaging system for differential counting and morphological classification of WBCs and RBCs in peripheral blood smears. It is a compact and easily operated instrument that can offer low-volume and small satellite laboratories the possibilities of readily available blood cell analysis that can be stored and retrieved for consultation with remote locations.


Assuntos
Células Sanguíneas , Leucócitos , Humanos , Reprodutibilidade dos Testes , Contagem de Leucócitos , Testes Hematológicos , Contagem de Células Sanguíneas
2.
Thromb Res ; 201: 18-22, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33626463

RESUMO

INTRODUCTION: For exclusion of pulmonary embolism (PE) clinical decision rules in combination with a D-dimer assay are applied. Currently available D-dimer assays are not standardized and it is unknown whether these differences have an impact on diagnostic management of suspected PE. Therefore, the aim is to explore differences between D-dimer assays and their impact on diagnostic outcome. METHODS: Data from all patients included in the YEARS study were collected. The YEARS study is a prospective, multicentre, cohort outcome study evaluating 3462 patients with suspected PE in which four different D-dimer assays were applied (Liatest, Innovance, Tinaquant, Vidas). Median D-dimer concentrations were calculated for each D-dimer assay. Sensitivity, specificity, PPV and NPV for detection of PE of all four assays were determined in patients without YEARS items and in those with ≥1 YEARS items (i.e. symptomatic deep vein thrombosis, haemoptysis, and whether PE is the most likely diagnosis). RESULTS: A total of 1323, 1100, 768 and 271 D-dimer concentrations were collected using the Liatest Innovance, Tinaquant and Vidas assay, respectively. Median D-dimer concentrations differed significantly between assays, with lowest values in the Tinaquant assay. In patients without YEARS items using a cutoff level of 1000 ng/mL, the NPV varied from 99,5 to 100%. In patients with ≥1 YEARS items using a 500 ng/mL cutoff, the NPV varied from 97,0 to 100% depending on the assay. CONCLUSIONS: The overall high NPV for all assays demonstrates the clinical value of the D-dimer assay. However, these results confirm differences between D-dimer assays, which have an impact on follow-up imaging. This emphasizes the need for standardization of D-dimer assays.


Assuntos
Embolia Pulmonar , Trombose Venosa , Produtos de Degradação da Fibrina e do Fibrinogênio , Humanos , Valor Preditivo dos Testes , Estudos Prospectivos , Embolia Pulmonar/diagnóstico , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA