Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 89(10): 10D127, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399791

RESUMO

We add a collection path obscuration to a confocal telescope and confirm theoretical predictions of significant improvement in the longitudinal spatial localization. The improvements of spatial localization permitted an extension of the confocal telescope's focal length from 150 mm to 500 mm. At this longer focal length, millimeter-scale spatial localization is confirmed by comparing radial profiles of metastable state density obtained via confocal and conventional optical arrangements in a helicon source. The long focal length arrangement enables the measurement of argon neutral velocity distribution functions in the conventionally inaccessible region under a helicon source antenna.

2.
Rev Sci Instrum ; 88(10): 103506, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29092491

RESUMO

We present measurements of ion velocity distributions obtained by laser induced fluorescence (LIF) using a single viewport in an argon plasma. A patent pending design, which we refer to as the confocal fluorescence telescope, combines large objective lenses with a large central obscuration and a spatial filter to achieve high spatial localization along the laser injection direction. Models of the injection and collection optics of the two assemblies are used to provide a theoretical estimate of the spatial localization of the confocal arrangement, which is taken to be the full width at half maximum of the spatial optical response. The new design achieves approximately 1.4 mm localization at a focal length of 148.7 mm, improving on previously published designs by an order of magnitude and approaching the localization achieved by the conventional method. The confocal method, however, does so without requiring a pair of separated, perpendicular optical paths. The confocal technique therefore eases the two window access requirement of the conventional method, extending the application of LIF to experiments where conventional LIF measurements have been impossible or difficult, or where multiple viewports are scarce.

3.
Rev Sci Instrum ; 87(1): 013505, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26827319

RESUMO

Here we describe a novel infrared laser-induced fluorescence scheme for the 1s2 state of Ar-I using an 841.052 nm (vacuum) Sacher tunable diode laser oscillator and compare it to an established 667.913 nm (vacuum) 1s4-pumping Ar-I LIF scheme using a master oscillator power amplifier laser [A. M. Keesee et al. Rev. Sci. Instrum. 75, 4091 (2004)]. The novel scheme exhibits a significantly greater signal-to-noise ratio for a given injected laser power than the established scheme. We argue that this is caused by less intense spontaneous Ar-I radiation near the LIF emission wavelength for the 1s2 scheme as compared to the 1s4 scheme. In addition we present an updated iodine cell spectrum around the 1s4 LIF scheme pump wavelength.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...