Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anesth Pain Med (Seoul) ; 16(3): 284-289, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34233409

RESUMO

BACKGROUND: Tachycardia-polyuria syndrome is characterized by polyuria occurring because of tachycardia with a heart rate of ≥ 120 beats/min lasting ≥ 30 min. We report such a case occurring after swan-ganz catheterization. CASE: A 41-year-old male was scheduled for living-donor liver transplantation. After general anesthesia, atrial fibrillation occurred during swan-ganz catheterization, and polyuria developed 1 h later. During the anhepatic phase, the patient's heart rate increased further, and cardioversion was performed. After a normal sinus rhythm was achieved, the patient's urine output returned to normal. CONCLUSIONS: The patient's polyuria seemed related to the iatrogenic atrial fibrillation occurring during swan-ganz catheterization. Although we did not measure atrial natriuretic peptide, an increase in its concentration may have been the main mechanism of polyuria, as natriuresis was observed.

2.
Anesth Pain Med (Seoul) ; 16(4): 391-397, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35139622

RESUMO

BACKGROUND: The OptiscopeTM and the backward, upward, rightward pressure (BURP) maneuver are widely used in clinical practice because the BURP maneuver facilitates intubation by improving visualization of the larynx. However, the effect of the BURP maneuver is unclear when using the OptiscopeTM. Therefore, we retrospectively investigated the effect of the BURP maneuver on intubation using the OptiscopeTM. METHODS: Sixty-eight patients intubated with the OptiscopeTM were enrolled. We used the BURP maneuver in Group A (n = 33) and the conventional maneuver (which does not use the BURP maneuver) in Group B (n = 35). BURP application status was a binary variable representing whether the BURP maneuver was used during the intubation. A multiple linear regression analysis was performed to assess the effects of the BURP application status on intubation time controlling for body mass index, preoperative dental injury status, obstructive sleep apnea history, thyromental distance, sternomental distance, interincisor distance, history of neck rotation restriction, and Mallampati classification. RESULTS: There was no difference in the intubation time between the two groups. According to the regression model (R2 = 0.308, P = 0.007), the BURP maneuver (Group A) decreased the intubation time by 6.089 seconds (95% confidence interval 1.303-10.875, P = 0.014) compared to Group B.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...