Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 60
Filtrar
1.
Acta Radiol ; : 2841851241245104, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38623647

RESUMO

BACKGROUND: Post-contrast T1-Sampling Perfection with Application-optimized Contrasts using different flip angle Evolutions (SPACE) is the preferred 3D T1 spin-echo sequence for evaluating brain metastases, regardless of the prolonged scan time. PURPOSE: To evaluate the application of accelerated post-contrast T1-SPACE with iterative denoising (ID) for intracranial enhancing lesions in oncologic patients. MATERIAL AND METHODS: For evaluation of intracranial lesions, 108 patients underwent standard and accelerated T1-SPACE during the same imaging session. Two neuroradiologists evaluated the overall image quality, artifacts, degree of enhancement, mean contrast-to-noise ratiolesion/parenchyma, and number of enhancing lesions for standard and accelerated T1-SPACE without ID. RESULTS: Although there was a significant difference in the overall image quality and mean contrast-to-noise ratiolesion/parenchyma between standard and accelerated T1-SPACE without ID and accelerated SPACE with and without ID, there was no significant difference between standard and accelerated T1-SPACE with ID. Accelerated T1-SPACE showed more artifacts than standard T1-SPACE; however, accelerated T1-SPACE with ID showed significantly fewer artifacts than accelerated T1-SPACE without ID. Accelerated T1-SPACE without ID showed a significantly lower number of enhancing lesions than standard- and accelerated T1-SPACE with ID; however, there was no significant difference between standard and accelerated T1-SPACE with ID, regardless of lesion size. CONCLUSION: Although accelerated T1-SPACE markedly decreased the scan time, it showed lower overall image quality and lesion detectability than the standard T1-SPACE. Application of ID to accelerated T1-SPACE resulted in comparable overall image quality and detection of enhancing lesions in brain parenchyma as standard T1-SPACE. Accelerated T1-SPACE with ID may be a promising replacement for standard T1-SPACE.

2.
Neurointervention ; 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38615689

RESUMO

PURPOSE: In this study, we determined whether there were significant differences in procedure time, radiation dose, fluoroscopy time, and total contrast media dose when unruptured wideneck bifurcation aneurysms (WNBAs) were treated with the Woven EndoBridge (WEB) device and stent-assisted coil (SAC) embolization. MATERIALS AND METHODS: The WEB device and SAC embolization (14:17) were used to treat 31 cases of internal carotid artery bifurcation, anterior communicating artery, middle cerebral artery bifurcation, and basilar bifurcation aneurysms between August 2021 and December 2022. The procedure time, radiation dose, fluoroscopy time, and total contrast medium dose between the 2 treatment groups were compared and analyzed. In the WEB device group, the results between operators were compared, and the follow-up radiologic outcomes were investigated. RESULTS: The procedure and fluoroscopy times were significantly shorter in the WEB device group. Radiation and total contrast media dose were also significantly smaller in the WEB device, but there was no significant difference in results between operators. The follow-up radiological outcome showed adequate occlusion in 83.3% (10/12) of cases. CONCLUSION: The WEB device can be used as an alternative treatment method among the available endovascular treatment methods for WNBAs to reduce radiation exposure and the dose of contrast media when used adequately with appropriate indications.

3.
J Korean Soc Radiol ; 84(6): 1361-1366, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38107687

RESUMO

The persistent primitive olfactory artery (PPOA) is a rare variant of the anterior cerebral artery, first reported in 1979. It reportedly has a high correlation with the development of aneurysms, owing to the hemodynamic stress induced by the structural characteristics of the hairpin turn. Herein, we present a rare case of PPOA type 4 with a fusiform aneurysm at the hairpin turn segment in a 46-year-old female with occasional headaches. Time-of-flight MR angiography and transfemoral cerebral angiography revealed an unusual branch arising from the left A1 segment, running anteromedially along the ipsilateral olfactory tract, and turning the hairpin posterior to the olfactory bulb. This branch continued into the left accessory middle cerebral artery, and a fusiform aneurysm was observed at the hairpin segment. No further treatment was performed, and follow-up imaging was recommended. Nevertheless, it is essential to recognize and diagnose these rare variations.

4.
Curr Med Imaging ; 2023 06 12.
Artigo em Inglês | MEDLINE | ID: mdl-37309764

RESUMO

BACKGROUND: Synthetic MRI can provide multiple contrast-weighted brain images with high resolution from a single scan via a 3D sequence using an interleaved Look-Locker acquisition sequence with a T2 preparation pulse (3D-QALAS). OBJECTIVE: This study aimed to assess the diagnostic image quality of 3D synthetic MRI using compressed sensing (CS) in clinical practice. METHODS: We retrospectively reviewed the imaging data of 47 patients who underwent brain MRI, including 3D synthetic MRI using CS in a single session, between December 2020 and February 2021. Two neuroradiologists independently evaluated the overall image quality, anatomic demarcation, and artifacts for synthetic 3D T1-weighted, T2-weighted, FLAIR, phase-sensitive inversion recovery (PSIR), and double inversion recovery images, using a 5-point Likert scale. The interobserver agreement between the two readers was assessed using percent agreement and weighted κ statistics. RESULTS: The overall image quality of 3D synthetic T1WI and PSIR was good to excellent, with easy or excellent anatomic demarcation and mild or no visible artifact. However, other 3D synthetic MRI-derived images showed insufficient image quality and anatomic demarcation with marked CSF pulsation artifacts. In particular, 3D synthetic FLAIR showed high-signal artifacts on the brain surface. CONCLUSION: 3D synthetic MRI, at its current status, cannot completely replace conventional brain MRI in daily clinical practice. However, 3D synthetic MRI can achieve scan-time reduction using CS and parallel imaging and may be useful for motion-prone or pediatric patients requiring 3D images where time-efficiency is important.

5.
J Korean Soc Radiol ; 84(3): 745-749, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37325010

RESUMO

Gerstmann-Sträussler-Scheinker (GSS) disease is a rare hereditary prion disease which is clinically characterized by a progressive cerebellar ataxia followed by cognitive impairment. We report a rare case of GSS disease in a 39-year-old male patient who complained of a progressive gait disturbance followed by dysarthria with cognitive impairment, after five months from the onset of initial symptom. His brain MRI scan revealed multifocal symmetric diffusion restricted lesions with T2/FLAIR hyperintensities in bilateral cerebral cortices, basal ganglia, and thalami. His family members also manifested similar symptoms in their 40-50s, suggesting the possibility of a genetic disease. Finally, he was genetically diagnosed with GSS disease by real-time quaking-induced conversion and prion protein (PRNP) gene sequencing test.

6.
Curr Med Imaging ; 19(7): 784-787, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36437728

RESUMO

BACKGROUND: Diffuse large B-cell lymphomas are the most common type of non-Hodgkin lymphoma. Because cutaneous lymphomas predominantly originate from the T cells, primary cutaneous diffuse large B-cell lymphomas are considered a rare subtype of extranodal diffuse large B-cell lymphomas that commonly involve the subcutaneous tissues of the trunk and extremities. To date, only a single case of facial primary cutaneous diffuse large B-cell lymphoma has been reported in the literature. CASE REPORT: We present a case of primary cutaneous diffuse large B-cell lymphoma presented with a small painless nodule in the right nasolabial fold that had persisted for 10 days in a 67-year-old man. Ultrasonographic findings of this lesion mimicked the features of a complicated epidermal inclusion cyst. Primary cutaneous diffuse large B-cell lymphoma was confirmed by an excisional biopsy of the mass. CONCLUSION: The diagnosis of primary cutaneous diffuse large B-cell lymphomas presenting as "oops lesions" in daily clinical practice can be challenging due to their rarity and nonspecific clinical and radiological findings. Therefore, clinical suspicion and awareness are critical for the accurate diagnosis and management of patients with palpable soft tissue masses in the head and neck region.


Assuntos
Linfoma Difuso de Grandes Células B , Neoplasias Cutâneas , Masculino , Humanos , Lactente , Sulco Nasogeniano/diagnóstico por imagem , Sulco Nasogeniano/patologia , Linfoma Difuso de Grandes Células B/diagnóstico por imagem , Neoplasias Cutâneas/diagnóstico por imagem
7.
Acta Radiol ; 64(7): 2245-2252, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36575592

RESUMO

BACKGROUND: Computed tomography (CT)-guided percutaneous transthoracic needle biopsy (PTNB) is highly affected by respiratory motion; however, respiratory motion of target nodule during the PTNB and its effect on CT-guided lung biopsy have not been studied. PURPOSE: To investigate the effect of the respiratory motion of pulmonary nodules on CT-guided PTNB. MATERIAL AND METHODS: We retrospectively reviewed the procedural CT scans of 426 pulmonary nodules that underwent PTNB during quiet breathing. Maximal and average respiratory motions were measured using the difference of table position of the targeted nodule between multiple procedural scans. Diagnostic performance, complications, and technical factors of PTNB in nodules with large motion (maximal motion >1 cm) were compared with those in nodules with small motion (≤1 cm). RESULTS: The mean maximal and average respiratory motions between tidal volume breathing were 5.4 ± 4.4 and 2.7 ± 2.6 mm, respectively. Sensitivity and accuracy were 93.1% and 96.1% in nodules with large motion, compared with 94.7% and 95.9% in nodules with small motion, respectively. Respiratory targeting (P < 0.001), needle modulation (P < 0.001), motion artifact of target (P < 0.001), target disappearance from scans (P < 0.001), and number of performed CT scans (P < 0.001) were significantly higher in the large motion group, with no significant difference in radiation dose and complications between the groups. CONCLUSION: The respiratory motion of pulmonary nodules during CT-guided PTNB may cause technical difficulties but does not affect diagnostic performance nor complications associated with PTNB.


Assuntos
Neoplasias Pulmonares , Nódulos Pulmonares Múltiplos , Humanos , Neoplasias Pulmonares/patologia , Estudos Retrospectivos , Pulmão/diagnóstico por imagem , Pulmão/patologia , Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Biópsia por Agulha/métodos , Biópsia Guiada por Imagem/métodos , Radiografia Intervencionista/métodos
8.
Interv Neuroradiol ; 29(1): 20-29, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34913378

RESUMO

PURPOSE: Imaging follow-up after endovascular treatment is important; however, time-of-flight magnetic resonance angiography (TOF-MRA) has limitations associated with magnetic susceptibility and radiofrequency shielding caused by the stent and coils. We evaluated the diagnostic performance of pointwise encoding time reduction with radial acquisition (PETRA)-MRA after endovascular treatment for intracranial aneurysms. MATERIAL AND METHODS: A total of 186 patients with 211 aneurysms who underwent both pointwise encoding time reduction with radial acquisition- and time-of-flight magnetic resonance angiography in the same imaging session for follow-up after endovascular treatment. We subjectively graded the overall image quality, visualization of treated sites, and occlusion status. RESULTS: Although the overall image quality scores of pointwise encoding time reduction with radial acquisition-magnetic resonance angiography were significantly lower than those of time-of-flight magnetic resonance angiography for both observers (4.04 ± 0.81 vs. 4.85 ± 0.35 [observer 1], 4.60 ± 0.69 vs. 4.94 ± 0.24 [observer 2]) (both P < .001), the visibility of treated sites using pointwise encoding time reduction with radial acquisition-magnetic resonance angiography was significantly better than that of time-of-flight magnetic resonance angiography overall (4.27 ± 0.97 vs. 3.42 ± 1.01; P < .001), in the distal internal carotid artery (4.46 ± 0.79 vs. 3.40 ± 1.00; P < .001), and in the middle cerebral artery (4.19 ± 0.93 vs. 3.08 ± 0.53, P = 0.007). Pointwise encoding time reduction with radial acquisition-magnetic resonance angiography showed a higher area under the curve than time-of-flight magnetic resonance angiography for the evaluation of treated aneurysm occlusion, except for posterior circulation aneurysms. CONCLUSIONS: Pointwise encoding time reduction with radial acquisition-magnetic resonance angiography showed better visualization of treated sites and better diagnostic performance than time-of-flight magnetic resonance angiography for anterior circulation aneurysms. However, Pointwise encoding time reduction with radial acquisition-magnetic resonance angiography showed limitations in the follow-up evaluation of posterior circulation aneurysms.


Assuntos
Embolização Terapêutica , Aneurisma Intracraniano , Doenças Vasculares , Humanos , Aneurisma Intracraniano/terapia , Seguimentos , Angiografia por Ressonância Magnética/métodos , Embolização Terapêutica/métodos , Angiografia Digital/métodos , Angiografia Cerebral/métodos
9.
Taehan Yongsang Uihakhoe Chi ; 83(3): 719-723, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-36238521

RESUMO

Rosai-Dorfman Disease (RDD) is a rare lymphoproliferative disease, and the occurrence of isolated intracranial RDD is extremely rare. Most cases of intracranial RDDs present as dural masses showing homogenous enhancement on MRI, which makes it difficult to differentiate these masses from meningiomas before surgery unless massive cervical lymphadenopathy is observed. We herein report a rare case of isolated intracranial RDD in a 65-year-old male. Brain MRI revealed a well-defined enhancing mass-like lesion involving the right frontal convexity and subtle diffusion restriction. However, only a subtle blush was observed on the preoperative cerebral angiogram. Although instances of isolated intracranial RDD are rare, it should be considered as a potential differential diagnosis when a dural mass with hypovascularity is visualized on the cerebral angiogram.

10.
J Comput Assist Tomogr ; 46(2): 294-299, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35297585

RESUMO

OBJECTIVE: The aim of the study was to retrospectively evaluate the safety and accuracy of computed tomography (CT)-guided percutaneous transthoracic needle biopsy (PTNB) of lung lesions during quiet breathing. METHODS: We investigated the diagnostic performance and complication rate of 585 procedures in 563 patients (357 men; mean age, 67.7 years), who underwent CT-guided PTNBs during quiet breathing, aided by a respiratory targeting technique from May 2017 to July 2019. Differences between the cases with and without respiratory targeting were analyzed. Logistic regression analyses were performed to examine the development of pneumothorax and hemoptysis. RESULTS: Percutaneous transthoracic needle biopsy samples were successfully obtained in 574 of 585 procedures (98.1%). Final diagnoses included: 410 malignant cases, 119 benign cases, and 45 indeterminate cases. The sensitivity, specificity, and accuracy of diagnosis were 94.4%, 100%, and 95.7%, respectively. Use of respiratory targeting was associated with younger age (P = 0.004), smaller lesion size (P < 0.001), peripheral location (P = 0.003), shorter distance from the diaphragm (P < 0.001), lower lobe location (P < 0.001), prone position (P = 0.004), and visible motion artifact (P < 0.001). Pneumothorax and hemoptysis rates were 22.9% and 7.9%, respectively. Upon multivariate analysis, emphysema (P = 0.002) was the only independent risk factor for pneumothorax, whereas distance from the pleura greater than 2 cm (P < 0.001), tissue sampling 3 times or more (P = 0.003), and a less experienced operator (P < 0.001) were risk factors for hemoptysis. CONCLUSIONS: Computed tomography-guided PTNB during quiet breathing with respiratory targeting yielded high diagnostic performance with a slightly higher rate of complications. Free-breathing PTNB can be applied in clinical practice, based on lesion location and risk factors for complications.


Assuntos
Biópsia Guiada por Imagem , Neoplasias Pulmonares , Radiografia Intervencionista , Idoso , Humanos , Biópsia Guiada por Imagem/métodos , Pulmão/diagnóstico por imagem , Pulmão/patologia , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Masculino , Radiografia Intervencionista/métodos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
11.
AJR Am J Roentgenol ; 218(6): 1062-1073, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-34985311

RESUMO

BACKGROUND. Isotropic 3D T1-weighted imaging has long acquisition times, potentially leading to motion artifact and altered brain volume measurements. Acquisition times may be greatly shortened using an isotropic ultrafast 3D echo-planar imaging (EPI) T1-weighted sequence. OBJECTIVE. The purpose of this article was to compare automated brain volume measurements between conventional 3D T1-weighted imaging and ultrafast 3D EPI T1-weighted imaging. METHODS. This retrospective study included 36 patients (25 women, 11 men; mean age, 68.4 years) with memory impairment who underwent 3-T brain MRI. Examinations included both conventional 3D T1-weighted imaging using inversion recovery gradient-recalled echo sequence (section thickness, 1.0 mm; acquisition time, 3 minutes 4 seconds) and, in patients exhibiting motion, an isotropic ultrafast 3D EPI T1-weighted sequence (section thickness, 1.2 mm; acquisition time, 30 seconds). The 36-patient sample excluded five patients in whom severe motion artifact rendered the conventional sequence of insufficient quality for volume measurements. Automated brain volumetry was performed using NeuroQuant (version 3.0, CorTechs Laboratories) and FreeSurfer (version 7.1.1, Harvard University) software. Volume measurements were compared between sequences for nine regions in each hemisphere. RESULTS. Volumes showed substantial to almost perfect agreement between the two sequences for most regions bilaterally. However, most regions showed significant mean differences between sequences, and Bland-Altman analyses showed consistent systematic biases and wide limits of agreement (LOA). For example, for the left hemisphere using NeuroQuant, volume was significantly greater for the ultrafast sequence in four regions and significantly greater for the conventional sequence in three regions, whereas standardized effect size between sequences was moderate for four regions and large for one region. Using NeuroQuant, mean bias (ultrafast minus conventional) and 95% LOA were greatest in cortical gray matter bilaterally (-50.61 cm3 [-56.27 cm3, -44.94 cm3] for the left hemisphere; -50.02 cm3 [-54.88 cm3, -45.16 cm3] for the right hemisphere). The variation between the two sequences was observed in subset analyses of 16 patients with and 20 patients without Alzheimer disease. CONCLUSION. Brain volume measurements show significant differences and systematic biases between the conventional and ultrafast sequences. CLINICAL IMPACT. In patients in whom severe motion artifact precludes use of the conventional sequence, the ultrafast sequence may be useful to enable brain volume-try. However, the current conventional 3D T1-weighted sequence remains preferred in patients who can tolerate the standard examination.


Assuntos
Imagem Ecoplanar , Imageamento por Ressonância Magnética , Idoso , Encéfalo/diagnóstico por imagem , Imagem Ecoplanar/métodos , Feminino , Humanos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Masculino , Reprodutibilidade dos Testes , Estudos Retrospectivos , Software
12.
J Mov Disord ; 15(1): 71-74, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34937161

RESUMO

Despite recent advances in next-generation sequencing, the underlying etiology of adult-onset leukoencephalopathy has been difficult to elucidate. Cerebral autosomal dominant arteriopathy with subcortical infarcts and leukoencephalopathy (CADASIL) is a representative hereditary adult-onset leukoencephalopathy associated with vasculopathy. Leukoencephalopathy in spastic paraplegia type 4 (SPG4) is known to be rare, but it might be underestimated because most spastic paraplegia with leukoencephalopathy is rarely considered. We report a case of co-occurring SPG4 and CADASIL. A 61-year-old male presented with sudden visual impairment after a headache. He showed a spastic gait and had a family history with similar symptoms. An SPG4 gene mutation and a pathogenic variant in the NOTCH3 gene were found. This case shows that the diverse and complex clinical manifestations of patients with extensive leukoencephalopathy are related to more than one gene mutation. We also suggest the necessity for relevant genetic tests in the diagnosis of adult-onset leukoencephalopathy.

13.
Korean J Radiol ; 22(8): 1341-1351, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34132074

RESUMO

OBJECTIVE: To compare the quality of various polychromatic and monochromatic images with or without using an iterative metal artifact reduction algorithm (iMAR) obtained from a dual-energy computed tomography (CT) to evaluate total knee arthroplasty. MATERIALS AND METHODS: We included 58 patients (28 male and 30 female; mean age [range], 71.4 [61-83] years) who underwent 74 knee examinations after total knee arthroplasty using dual-energy CT. CT image sets consisted of polychromatic image sets that linearly blended 80 kVp and tin-filtered 140 kVp using weighting factors of 0.4, 0, and -0.3, and monochromatic images at 130, 150, 170, and 190 keV. These image sets were obtained with and without applying iMAR, creating a total of 14 image sets. Two readers qualitatively ranked the image quality (1 [lowest quality] through 14 [highest quality]). Volumes of high- and low-density artifacts and contrast-to-noise ratios (CNRs) between the bone and fat tissue were quantitatively measured in a subset of 25 knees unaffected by metal artifacts. RESULTS: iMAR-applied, polychromatic images using weighting factors of -0.3 and 0.0 (P-0.3i and P0.0i, respectively) showed the highest image-quality rank scores (median of 14 for both by one reader and 13 and 14, respectively, by the other reader; p < 0.001). All iMAR-applied image series showed higher rank scores than the iMAR-unapplied ones. The smallest volumes of low-density artifacts were found in P-0.3i, P0.0i, and iMAR-applied monochromatic images at 130 keV. The smallest volumes of high-density artifacts were noted in P-0.3i. The CNRs were best in polychromatic images using a weighting factor of 0.4 with or without iMAR application, followed by polychromatic images using a weighting factor of 0.0 with or without iMAR application. CONCLUSION: Polychromatic images combined with iMAR application, P-0.3i and P0.0i, provided better image qualities and substantial metal artifact reduction compared with other image sets.


Assuntos
Artroplastia do Joelho , Artefatos , Idoso , Algoritmos , Feminino , Humanos , Masculino , Metais , Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia Computadorizada por Raios X
14.
J Clin Neurosci ; 87: 1-7, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33863515

RESUMO

PURPOSE: Whether M1 occlusions proximal (pM1) and distal (dM1) to the lenticulostriate perforators result in different clinical outcomes after mechanical thrombectomy (MT) is unknown. We retrospectively compared the clinical outcomes and baseline characteristics of patients with these two types of occlusions. METHODS: From March 2010 to May 2019, we performed MT for 141 M1 occlusions, including pM1 occlusions (n = 58) and dM1 occlusions (n = 83). RESULTS: Good clinical outcomes (modified Rankin Scale score 0 to 2) were achieved in 28 out of 58 (48.3%) patients with pM1 occlusions and 46 out of 83 (55.4%) patients with dM1 occlusions without significance (p = 0.493). Cardioembolic occlusions represented 19 out of 58 (32.6%) pM1 occlusions and 53 out of 83 (63.9%) dM1 occlusions, and atherosclerotic occlusions represented 37 out of 58 (63.8%) pM1 occlusions and 27 out of 83 (32.5%) dM1 occlusions, with significance (p = 0.001). Rescue treatments, such as balloon angioplasty or stenting, were needed more for pM1 occlusions than dM1 occlusions (21 out of 58 (36.2%) vs. 8 out of 83 (9.8%), p < 0.001). The multivariable logistic regression analysis demonstrated that the need for rescue treatment was associated with pM1 occlusions (adjusted odds ratio; 3.804, 95% confidence interval; 1.306-11.082, p = 0.014). CONCLUSIONS: In our series, pM1 and dM1 occlusions did not significantly differ in good clinical outcomes. Our study also showed that pM1 occlusions were more strongly associated with atherosclerotic occlusions, while dM1 occlusions were more strongly associated with cardioembolic occlusions, and rescue treatments were needed more often for pM1 occlusions than dM1 occlusions.


Assuntos
Acidente Vascular Cerebral/terapia , Trombectomia , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Stents , Resultado do Tratamento
15.
Neurol India ; 69(2): 378-382, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33904457

RESUMO

AIMS: Limited studies have compared the effectiveness of Solitaire and Trevo stentrievers for endovascular thrombectomy to achieve recanalization and improve functional outcomes of patients with acute ischemic stroke. Therefore, we compared the safety and efficacy of the two stents during endovascular thrombectomy for patients with acute ischemic stroke. MATERIALS AND METHODS: This study included 130 patients who underwent endovascular thrombectomy using either the Trevo (n = 51) or the Solitaire (n = 79) stent for anterior circulation acute ischemic stroke. Recanalization was classified using thrombolysis in cerebral infarction (TICI) grading. Efficacy and safety of the devices during endovascular thrombectomy were analyzed by evaluating the rate of good recanalization after the first pass, clot retrieval rate, final recanalization grade, use of rescue treatment, recanalization time, and hemorrhagic and thromboembolic complications. RESULTS: Overall, good recanalization (TICI grades 2b and 3) was achieved (Solitaire: n = 57, 72.2%; Trevo: n = 46, 90.2%) (P = 0.01). The rate of good recanalization after the first pass and clot retrieval rate were similar between groups; however, the use of rescue treatment was more frequent in the Solitaire group. Recanalization time was shorter in the Trevo group. The good clinical outcome rate was higher in the Trevo group but not statistically significantly. The rates of symptomatic hemorrhage and thromboembolism were not significantly different between groups. CONCLUSION: The Trevo stent achieved more successful recanalization with less need for rescue treatment and less time for recanalization than the Solitaire stent. There was no statistically significant difference in the clinical outcomes.


Assuntos
Isquemia Encefálica , AVC Isquêmico , Acidente Vascular Cerebral , Isquemia Encefálica/cirurgia , Humanos , Estudos Retrospectivos , Stents , Acidente Vascular Cerebral/cirurgia , Trombectomia , Resultado do Tratamento
16.
Neuroradiol J ; 34(3): 213-221, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33455533

RESUMO

BACKGROUND AND PURPOSE: Compressed sensing is used for accelerated acquisitions with incoherently under-sampled k-space data, and intracranial time-of-flight magnetic resonance angiography is suitable for compressed sensing. Compressed sensing time-of-flight is beneficial in decreasing acquisition time and increasing spatial resolution while maintaining acquisition time. In this retrospective study, we aimed to evaluate the image quality and diagnostic performance of compressed sensing time-of-flight with high spatial resolution and compare with parallel imaging time-of-flight using digital subtraction angiography as a reference. MATERIAL AND METHODS: In total, 39 patients with 46 intracranial aneurysms underwent parallel imaging and compressed sensing time-of-flight in the same imaging session and digital subtraction angiography before or after magnetic resonance angiography. The overall image quality, artefacts and diagnostic confidence were assessed by two observers. The contrast ratio, maximal aneurysm diameters and diagnostic performance were evaluated. RESULTS: Compressed sensing time-of-flight showed significantly better overall image quality, degree of artefacts and diagnostic confidence in both observers, with better inter-observer agreement. The contrast ratio was significantly higher for compressed sensing time-of-flight than for parallel imaging time-of-flight in both observers (source images, P < 0.001; maximum intensity projection images, P < 0.05 for both observers); however, the measured maximal diameters of aneurysms were not significantly different. Compressed sensing time-of-flight showed higher sensitivity, specificity, accuracy and positive and negative predictive values for detecting aneurysms than parallel imaging time-of-flight in both observers, with better inter-observer agreement. Compressed sensing time-of-flight was preferred over parallel imaging time-of-flight by both observers; however, parallel imaging time-of-flight was preferred in cases of giant and large aneurysms. CONCLUSIONS: Compressed sensing-time-of-flight provides better image quality and diagnostic performance than parallel imaging time-of-flight. However, neuroradiologists should be aware of under-sampling artefacts caused by compressed sensing.


Assuntos
Angiografia Digital , Angiografia Cerebral/métodos , Aneurisma Intracraniano/diagnóstico por imagem , Angiografia por Ressonância Magnética/métodos , Artefatos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Fatores de Tempo
17.
Taehan Yongsang Uihakhoe Chi ; 82(1): 128-138, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36237453

RESUMO

Purpose: We evaluated the risk factors for progression to chronic complicated bronchopleural fistula (BPF) after pulmonary resection using follow-up CT. Materials and Methods: We retrospectively reviewed 45 cases with BPF that had undergone pulmonary resection during 2010-2018. We compared the clinical and radiological characteristics of those with complicated BPF (n = 24) and those without complicated (sterilized) BPF (n = 21). The clinical and radiological risk factors for progression to chronic complicated BPF were examined by logistic regression analysis. Results: The thickness of the pleural cavity wall (p = 0.022), the size of the pleural cavity (p = 0.029), and the size increase of BPF on follow-up (p = 0.012) were significantly different between the two groups. The risk factors for progression to chronic complicated BPF were age > 70 years (odds ratio, 6.43; 95% confidence interval, 1.2-33.7), the thickness of the cavity wall > 5 mm (odds ratio, 52.5; 95% confidence interval, 5.1-545.4), and an increase in the size of the pleural cavity on follow-up CT (odds ratio, 12.5; 95% confidence interval, 2.1-73.5), only in the univariate analysis. Conclusion: The risk factors for progression to chronic complicated BPF can be evaluated using follow-up CT.

18.
Acta Radiol ; 62(9): 1193-1199, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32867507

RESUMO

BACKGROUND: Although time-of-flight magnetic resonance angiography (TOF-MRA) is widely used, it has limited usefulness for follow-up after stent-assisted coil embolization. Contrast-enhanced MRA (CE-MRA) and ultrashort echo time MRA have been suggested as alternative methods for visualization after this procedure. PURPOSE: To compare efficacy and usefulness of pointwise encoding time reduction with radial acquisition (PETRA) sequence in subtraction-based MRA (qMRA), TOF-MRA, and CE-MRA during the follow-up after Neuroform Atlas stent-assisted coil embolization for intracranial aneurysms. MATERIAL AND METHODS: This retrospective study included 23 patients with 24 aneurysms who underwent Neuroform Atlas stent-assisted coil embolization for intracranial aneurysms. All patients were evaluated with PETRA qMRA, TOF-MRA, and CE-MRA at the same follow-up session. The flow within stents, occlusion status, and presence of pseudo-stenosis were evaluated; inter-observer and intermodality agreements for the three methods were also graded. RESULTS: The mean score for flow visualization within the stents was significantly higher for PETRA qMRA and CE-MRA than for TOF-MRA (although no significant difference was found between PETRA qMRA and CE-MRA). Good inter-observer agreement was observed for each modality. PETRA qMRA and CE-MRA were more consistent with digital subtraction angiography (DSA) than TOF-MRA for aneurysm occlusion status. The intermodality agreement was better between PETRA qMRA and DSA, and between CE-MRA and DSA, than between DSA and TOF-MRA. Pseudo-stenosis was most frequently observed in TOF-MRA, followed by CE-MRA and PETRA qMRA. CONCLUSION: PETRA qMRA is useful for evaluating the parent artery patency and occlusion status of aneurysms after Neuroform Atlas stent-assisted coil embolization.


Assuntos
Angiografia Digital/métodos , Angiografia Cerebral/métodos , Embolização Terapêutica/métodos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Angiografia por Ressonância Magnética/métodos , Stents , Adulto , Idoso , Meios de Contraste , Feminino , Seguimentos , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tempo , Resultado do Tratamento
19.
J Clin Neurosci ; 82(Pt A): 128-133, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33317720

RESUMO

PURPOSE: To reduce procedural thromboembolisms, tailored antiplatelet drug preparation has been used according to antiplatelet resistance for endovascular coiling of unruptured aneurysms. We compared an aspirin plus clopidogrel group with a ticagrelor group using diffusion-weighted imaging (DWI) after stent-assisted coiling for unruptured aneurysms. METHODS: From October 2018 to April 2019, 72 patients with 78 aneurysms underwent stent-assisted coiling, with aspirin plus clopidogrel (n = 20 patients with 22 aneurysms) or ticagrelor (n = 52 patients with 56 aneurysms) as an antiplatelet preparation, and were enrolled in our study. All patients were evaluated using DWI 2 h after coiling to detect procedural thromboembolisms. RESULTS: Postprocedure infarction was observed on DWI in 37 procedures (47.4%), and symptomatic infarction occurred in 1 procedure (1.28%). Postprocedure infarction was significantly lower in the aspirin plus clopidogrel than in ticagrelor group (27.3% vs. 55.4%, p = 0.043). Postprocedure infarction was associated with aneurysm type (sidewall aneurysm (30.8%) vs. aneurysm with incorporated branches (64.1%), p = 0.006) and guiding catheter type (single (23.8%) vs. double (56.1%), p = 0.020). Multivariable logistic regression analysis demonstrated that postprocedure infarction was related to aneurysm type (adjusted odds ratio (OR); 3.317, confidence interval (CI); 1.223-8.991, p = 0.018), guiding catheter type (adjusted OR; 2.783, CI; 0.828-9.353, p = 0.098), and antiplatelet medication (adjusted OR; 1.295, CI; 0.969-1.730, p = 0.080). CONCLUSIONS: Postprocedure infarction was observed on DWI after stent-assisted coiling for unruptured aneurysms more frequently in the ticagrelor group than in the aspirin plus clopidogrel group. However, our study suggests that postprocedure infarction is more associated with aneurysm type than antiplatelet medication.


Assuntos
Aspirina/uso terapêutico , Clopidogrel/uso terapêutico , Inibidores da Agregação Plaquetária/uso terapêutico , Tromboembolia/tratamento farmacológico , Ticagrelor/uso terapêutico , Adulto , Idoso , Imagem de Difusão por Ressonância Magnética , Embolização Terapêutica , Feminino , Humanos , Aneurisma Intracraniano/terapia , Masculino , Pessoa de Meia-Idade , Stents
20.
J Cerebrovasc Endovasc Neurosurg ; 22(3): 165-175, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32971575

RESUMO

OBJECTIVE: Microsurgical treatment could be a good alternative for the treatment of recurrent cerebral aneurysm after coil embolization. The purpose of this study was to present our experience of microsurgical treatment for recurrent cerebral aneurysm previously treated using coil embolization. METHODS: From June 2012 to May 2019, 34 patients consecutively received microsurgical treatment for a recurrent cerebral aneurysm previously treated using coil embolization after it ruptured. RESULTS: Of the 34 patients with aneurysm, 33 had the aneurysm located in the anterior circulation. The most common location was the anterior communicating artery (13 cases). Immediate radiologic outcome at coil embolization was completed (n=6), residual neck (n=26), and residual sac (n=2). The reason for microsurgical treatment included rebleeding (n=12), persistent residual sac (n=1), and recurrence on follow-up study (n=21). Rebleeding occurred within 10 days after coil embolization in 10 cases, and the other 2 were due to regrowth. In the 20 recurred and saccular aneurysms, coil compaction was present in 11 aneurysms and regrowth in 9 aneurysms. Simple neck clipping (n=29) and clipping with coil mass extraction (n=3) was possible in the saccular aneurysms. The blood blister like aneurysm (n=2) were treated using bypass and endovascular internal carotid artery trapping. In the follow-up study group after microsurgical treatment there were no severe complications due to the treatment. Age, cause of retreatment, and modified Rankin Scale before microsurgery were associated with good outcome (p<0.001). CONCLUSIONS: Microsurgical treatment may be a viable and effective option for treating recurrent aneurysms previously treated by endovascular techniques.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...