Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Science ; 381(6664): eabg5998, 2023 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-37733866

RESUMO

Solid-state batteries with lithium metal anodes have the potential for higher energy density, longer lifetime, wider operating temperature, and increased safety. Although the bulk of the research has focused on improving transport kinetics and electrochemical stability of the materials and interfaces, there are also critical challenges that require investigation of the mechanics of materials. In batteries with solid-solid interfaces, mechanical contacts, and the development of stresses during operation of the solid-state batteries, become as critical as the electrochemical stability to keep steady charge transfer at these interfaces. This review will focus on stress and strain that result from normal and extended battery cycling and the associated mechanisms for stress relief, some of which lead to failure of these batteries.

2.
J Magn Reson ; 329: 107020, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34252841

RESUMO

Pulsed nuclear magnetic resonance (NMR) is widely used in high-precision magnetic field measurements. The absolute value of the magnetic field is determined from the precession frequency of nuclear magnetic moments. The Hilbert transform is one of the methods that have been used to extract the phase function from the observed free induction decay (FID) signal and then its frequency. In this paper, a detailed implementation of a Hilbert-transform based FID frequency extraction method is described, and it is briefly compared with other commonly used frequency extraction methods. How artifacts and noise level in the FID signal affect the extracted phase function are derived analytically. A method of mitigating the artifacts in the extracted phase function of an FID is discussed. Correlations between noises of the phase function samples are studied for different noise spectra. We discovered that the error covariance matrix for the extracted phase function is nearly singular and improper for constructing the χ2 used in the fitting routine. A down-sampling method for fixing the singular covariance matrix has been developed, so that the minimum χ2-fit yields properly the statistical uncertainty of the extracted frequency. Other practical methods of obtaining the statistical uncertainty are also discussed.

3.
J Mater Res ; 36(12): 2444-2455, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33875904

RESUMO

Nanoindentation and electron microscopy have been used to examine the length-scale-dependent stress relaxation mechanisms in well-annealed, high-purity indium at a homologous temperature of 0.69. The experimental methods, analysis, and observations serve as a stepping stone in identifying the stress relaxation mechanisms enabling the formation and growth of metallic dendrites originating at the buried interface between a metallic anode and a solid electrolyte separator. Indium's load-displacement data are found to be very similar to that of high-purity lithium. Residual hardness impressions show two distinct surface morphologies. Based on these morphologies, the measured hardness, and the estimated pile-up volume, it is proposed that residual impressions exhibiting significant pile-up are the result of deformation dominated by interface diffusion. Alternatively, impressions with no significant pile-up are taken to be the result of shear-driven dislocation glide. An analytical model is presented to rationalize the pile-up profile using interface diffusion.

4.
Sports Biomech ; : 1-12, 2021 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-33660587

RESUMO

Our purpose was to compare the mechanical properties of the protective outer shells of various athletic helmets in their final, fully manufactured form. Sections were taken from 3 different helmet shells (Bauer RE-AKT hockey helmet, Cascade R lacrosse helmet, and Riddell Speedflex football helmet) at 4 different locations (front, side, top, and rear) for a total of 12 test specimens. The 4 specimens from each helmet shell were potted together in epoxy resin moulds and mechanically polished. The hardness, elastic modulus and phase angle were measured using dynamic nanoindentation performed at 100 Hz with an oscillation amplitude of 1 nm (rms). Repeated ANOVA analysis was used to compare each of the dependent variables for each of the 3 helmets across the 4 different locations. The interaction between helmet type and location was significant for hardness (F6,63 = 2.84, P = 0.032, Pη2 = 0.21), elastic modulus (F6,63 = 6.412, P < 0.001, Pη2 = 0.38), and phase angle (F6,63 = 7.65, P < 0.001, Pη2 = 0.42). Polycarbonate has a higher ability to dissipate mechanical energy making it the recommended superior choice for helmet shells. In addition, the results lead us to speculate that manufacturing causes changes in the molecular weight or the distribution of fillers across locations for polyethylene but not for polycarbonate since mechanical properties are fairly uniform over the surface of football helmets, at least within a given helmet.

5.
Bone ; 48(4): 733-40, 2011 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-21185416

RESUMO

Type 1 diabetes (T1DM) increases the likelihood of a fracture. Despite serious complications in the healing of fractures among those with diabetes, the underlying causes are not delineated for the effect of diabetes on the fracture resistance of bone. Therefore, in a mouse model of T1DM, we have investigated the possibility that a prolonged state of diabetes perturbs the relationship between bone strength and structure (i.e., affects tissue properties). At 10, 15, and 18 weeks following injection of streptozotocin to induce diabetes, diabetic male mice and age-matched controls were examined for measures of skeletal integrity. We assessed 1) the moment of inertia (I(MIN)) of the cortical bone within diaphysis, trabecular bone architecture of the metaphysis, and mineralization density of the tissue (TMD) for each compartment of the femur by micro-computed tomography and 2) biomechanical properties by three-point bending test (femur) and nanoindentation (tibia). In the metaphysis, a significant decrease in trabecular bone volume fraction and trabecular TMD was apparent after 10 weeks of diabetes. For cortical bone, type 1 diabetes was associated with decreased cortical TMD, I(MIN), rigidity, and peak moment as well as a lack of normal age-related increases in the biomechanical properties. However, there were only modest differences in material properties between diabetic and normal mice at both whole bone and tissue-levels. As the duration of diabetes increased, bone toughness decreased relative to control. If the sole effect of diabetes on bone strength was due to a reduction in bone size, then I(MIN) would be the only significant variable explaining the variance in the maximum moment. However, general linear modeling found that the relationship between peak moment and I(MIN) depended on whether the bone was from a diabetic mouse and the duration of diabetes. Thus, these findings suggest that the elevated fracture risk among diabetics is impacted by complex changes in tissue properties that ultimately reduce the fracture resistance of bone.


Assuntos
Osso e Ossos/fisiopatologia , Diabetes Mellitus Experimental/fisiopatologia , Diabetes Mellitus Tipo 1/fisiopatologia , Animais , Densidade Óssea , Diabetes Mellitus Experimental/induzido quimicamente , Masculino , Camundongos , Camundongos Endogâmicos DBA , Estreptozocina , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...