Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
JMIR Res Protoc ; 13: e57329, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38669065

RESUMO

BACKGROUND: Relative motion between the residual limb and socket in individuals with transtibial limb loss can lead to substantial consequences that limit mobility. Although assessments of the relative motion between the residual limb and socket have been performed, there remains a substantial gap in understanding the complex mechanics of the residual limb-socket interface during dynamic activities that limits the ability to improve socket design. However, dynamic stereo x-ray (DSX) is an advanced imaging technology that can quantify 3D bone movement and skin deformation inside a socket during dynamic activities. OBJECTIVE: This study aims to develop analytical tools using DSX to quantify the dynamic, in vivo kinematics between the residual limb and socket and the mechanism of residual tissue deformation. METHODS: A lower limb cadaver study will first be performed to optimize the placement of an array of radiopaque beads and markers on the socket, liner, and skin to simultaneously assess dynamic tibial movement and residual tissue and liner deformation. Five cadaver limbs will be used in an iterative process to develop an optimal marker setup. Stance phase gait will be simulated during each session to induce bone movement and skin and liner deformation. The number, shape, size, and placement of each marker will be evaluated after each session to refine the marker set. Once an optimal marker setup is identified, 21 participants with transtibial limb loss will be fitted with a socket capable of being suspended via both elevated vacuum and traditional suction. Participants will undergo a 4-week acclimation period and then be tested in the DSX system to track tibial, skin, and liner motion under both suspension techniques during 3 activities: treadmill walking at a self-selected speed, at a walking speed 10% faster, and during a step-down movement. The performance of the 2 suspension techniques will be evaluated by quantifying the 3D bone movement of the residual tibia with respect to the socket and quantifying liner and skin deformation at the socket-residuum interface. RESULTS: This study was funded in October 2021. Cadaver testing began in January 2023. Enrollment began in February 2024. Data collection is expected to conclude in December 2025. The initial dissemination of results is expected in November 2026. CONCLUSIONS: The successful completion of this study will help develop analytical methods for the accurate assessment of residual limb-socket motion. The results will significantly advance the understanding of the complex biomechanical interactions between the residual limb and the socket, which can aid in evidence-based clinical practice and socket prescription guidelines. This critical foundational information can aid in the development of future socket technology that has the potential to reduce secondary comorbidities that result from complications of poor prosthesis load transmission. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): DERR1-10.2196/57329.


Assuntos
Extremidade Inferior , Pele , Tíbia , Humanos , Cotos de Amputação/diagnóstico por imagem , Cotos de Amputação/fisiopatologia , Membros Artificiais , Fenômenos Biomecânicos/fisiologia , Cadáver , Extremidade Inferior/diagnóstico por imagem , Extremidade Inferior/cirurgia , Extremidade Inferior/fisiologia , Movimento/fisiologia , Pele/diagnóstico por imagem , Tíbia/diagnóstico por imagem , Tíbia/cirurgia
2.
JMIR Res Protoc ; 13: e53412, 2024 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-38277197

RESUMO

BACKGROUND: Powered ankle-foot prosthetic devices can generate net positive mechanical work during gait, which mimics the physiological ankle. However, gait deviations can persist in individuals with transfemoral limb loss because of habit or lack of rehabilitation. Prosthetic research efforts favor the design or evaluation of prosthetic componentry and rarely incorporate any type of rehabilitation, despite evidence suggesting that it is critical for minimizing gait imbalances. Given the accelerated rate of innovation in prosthetics, there is a fundamental knowledge gap concerning how individuals with transfemoral limb loss should learn to correctly use powered ankle-foot devices for maximum functional benefit. Because of the recent advances in prosthetic technology, there is also a critical unmet need to develop guidelines for the prescription of advanced prosthetic devices that incorporate both physical and psychological components to identify appropriate candidates for advanced technology. OBJECTIVE: The primary goal of this investigation is to examine the roles of advanced prosthetic technology and a device-specific rehabilitative intervention on gait biomechanics, functional efficacy, and pain in individuals with transfemoral limb loss. The secondary goal is to develop preliminary rehabilitation guidelines for advanced lower limb prosthetic devices to minimize gait imbalances and maximize function and to establish preliminary guidelines for powered ankle-foot prosthetic prescription. METHODS: This prospective, multisite study will enroll 30 individuals with unilateral transfemoral limb loss. At baseline, participants will undergo a full gait analysis and assessment of function, neurocognition, cognitive load, subjective preferences, and pain using their current passive prosthesis. The participants will then be fitted with a powered ankle-foot device and randomized into 2 equal groups: a powered device with a device-specific rehabilitation intervention (group A) or a powered device with the current standard of practice (group B). Group A will undergo 4 weeks of device-specific rehabilitation. Group B will receive the current standard of practice, which includes basic device education but no further device-specific rehabilitation. Data collection procedures will then be repeated after 4 weeks and 8 weeks of powered ankle use. RESULTS: This study was funded in September 2017. Enrollment began in September 2018. Data collection will conclude by March 2024. The initial dissemination of results is expected in August 2024. CONCLUSIONS: The projected trends indicate that the number of individuals with limb loss will dramatically increase in the United States. The absence of effective, evidence-based interventions may make individuals with transfemoral limb loss more susceptible to increased secondary physical conditions and degenerative changes. With this expected growth, considerable resources will be required for prosthetic and rehabilitation services. Identifying potential mechanisms for correcting gait asymmetries, either through advanced prosthetic technology or rehabilitative interventions, can provide a benchmark for understanding the optimal treatment strategies for individuals with transfemoral limb loss. TRIAL REGISTRATION: ClinicalTrials.gov NCT03625921; https://clinicaltrials.gov/study/NCT03625921. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): DERR1-10.2196/53412.

3.
BMJ Open ; 13(11): e072265, 2023 11 19.
Artigo em Inglês | MEDLINE | ID: mdl-37984948

RESUMO

INTRODUCTION: The number of people with lower limb loss continues to grow, though most research to date has been non-committal and lacks the appropriate clinical guidance required for proper prosthetic prescription. Previous literature using traditional spatiotemporal and biomechanical measures has not accurately identified differences in gait patterns when using different prosthetic devices. Therefore, a knowledge gap remains. To aid in determining the impact of different devices on gait in individuals with lower limb loss, a more sensitive quantitative measure should be used to supplement traditional biomechanical analyses. Continuous measures of coordination and stability, evaluated using relative phase analysis, has been shown to detect changes in gait patterns when traditional variables cannot. However, these measures have yet to be fully assessed in this population. This investigation will fill the knowledge gap by using relative phase analysis to provide a comprehensive description of kinematic behaviour by evaluating continuous interlimb coordination and stability for individuals with lower limb loss. METHODS AND ANALYSIS: Biomechanical analysis of individuals with lower limb loss during walking activities will be evaluated using relative phase analysis to identify the continuous interlimb coordination and stability relationships between the upper and lower extremities of these individuals. Three-dimensional motion capture will enable kinematic properties of movement to be captured and analysed. Non-traditional measures of analysis will be used. ETHICS AND DISSEMINATION: This study was approved by the Veterans Affairs New York Harbor Healthcare System Institutional Review Board (IRBNet #1573135, MIRB #1775). Findings will be disseminated through peer-reviewed publications, academic conference presentations, invited workshops, webinars and seminars.


Assuntos
Marcha , Caminhada , Humanos , Estudos Retrospectivos , Extremidade Inferior , Modalidades de Fisioterapia , Fenômenos Biomecânicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...