Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 55
Filtrar
1.
Otolaryngol Head Neck Surg ; 170(6): 1648-1658, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38329219

RESUMO

OBJECTIVE: To elucidate the differences in auditory performance between auditory brainstem implant (ABI) patients with tumor or nontumor etiologies. DATA SOURCES: PubMed, Embase, and Web of Science Core Collection from 1990 to 2021. REVIEW METHODS: We included published studies with 5 or more pediatric or adult ABI users. Auditory outcomes and side effects were analyzed with weighted means for closed-set, open-set speech, and categories of auditory performance (CAP) scores. Overall performance was compared using an Adult Pediatric Ranked Order Speech Perception (APROSPER) scale created for this study. RESULTS: Thirty-six studies were included and underwent full-text review. Data were extracted for 662 tumor and 267 nontumor patients. 83% were postlingually deafened and 17% were prelingually deafened. Studies that included tumor ABI patients had a weighted mean speech recognition of 39.2% (range: 19.6%-83.3%) for closed-set words, 23.4% (range: 17.2%-37.5%) for open-set words, 21.5% (range: 2.7%-48.4%) for open-set sentences, and 3.1 (range: 1.0-3.2) for CAP scores. Studies including nontumor ABI patients had a weighted mean speech recognition of 79.8% (range: 31.7%-84.4%) for closed-set words, 53.0% (range: 14.6%-72.5%) for open-set sentences, and 2.30 (range: 2.0-4.7) for CAP scores. Mean APROSPER results indicate better auditory performance among nontumor versus tumor patients (3.5 vs 3.0, P = .04). Differences in most common side effects were also observed between tumor and nontumor ABI patients. CONCLUSION: Auditory performance is similar for tumor and nontumor patients for standardized auditory test scores. However, the APROSPER scale demonstrates better ABI performance for nontumor compared to tumor patients.


Assuntos
Implantes Auditivos de Tronco Encefálico , Percepção da Fala , Adulto , Humanos , Surdez/cirurgia , Percepção da Fala/fisiologia , Resultado do Tratamento , Criança
2.
Chem Asian J ; 19(5): e202301106, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38390759

RESUMO

Halogen bonds are typically observed to have a linear arrangement with a 180° angle between the nucleophile and the halogen bond acceptor X-R. This linearity is commonly explained using the σ-hole model, although there have been alternative explanations involving exchange repulsion forces. We employ two-dimensional Distortion/Interaction and Energy Decomposition Analysis to examine the archetypal H3 N⋯X2 halogen bond systems. Our results indicate that although halogen bonds are predominantly electrostatic, their directionality is largely due to decreased Pauli repulsion in linear configurations as opposed to angled ones in the I2 and Br2 systems. As we move to the smaller halogens, Cl2 and F2 , the influence of Pauli repulsion diminishes, and the energy surface is shaped by orbital interactions and electrostatic forces. These results support the role of exchange repulsion forces in influencing the directionality of strong halogen bonds. Additionally, we demonstrate that the 2D Energy Decomposition Analysis is a useful tool for enhancing our understanding of the nature of potential energy surfaces in noncovalent interactions.

3.
RSC Med Chem ; 14(3): 444-453, 2023 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-36970152

RESUMO

Pretargeting is a powerful nuclear imaging strategy to achieve enhanced imaging contrast for nanomedicines and reduce the radiation burden to healthy tissue. Pretargeting is based on bioorthogonal chemistry. The most attractive reaction for this purpose is currently the tetrazine ligation, which occurs between trans-cyclooctene (TCO) tags and tetrazines (Tzs). Pretargeted imaging beyond the blood-brain barrier (BBB) is challenging and has not been reported thus far. In this study, we developed Tz imaging agents that are capable of ligating in vivo to targets beyond the BBB. We chose to develop 18F-labeled Tzs as they can be applied to positron emission tomography (PET) - the most powerful molecular imaging technology. Fluorine-18 is an ideal radionuclide for PET due to its almost ideal decay properties. As a non-metal radionuclide, fluorine-18 also allows for development of Tzs with physicochemical properties enabling passive brain diffusion. To develop these imaging agents, we applied a rational drug design approach. This approach was based on estimated and experimentally determined parameters such as the BBB score, pretargeted autoradiography contrast, in vivo brain influx and washout as well as on peripheral metabolism profiles. From 18 initially developed structures, five Tzs were selected to be tested for their in vivo click performance. Whereas all selected structures clicked in vivo to TCO-polymer deposited into the brain, [18F]18 displayed the most favorable characteristics with respect to brain pretargeting. [18F]18 is our lead compound for future pretargeted neuroimaging studies based on BBB-penetrant monoclonal antibodies. Pretargeting beyond the BBB will allow us to image targets in the brain that are currently not imageable, such as soluble oligomers of neurodegeneration biomarker proteins. Imaging of such currently non-imageable targets will allow early diagnosis and personalized treatment monitoring. This in turn will accelerate drug development and greatly benefit patient care.

4.
Hear Res ; 429: 108688, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36628803

RESUMO

Measurement of bone conduction (BC) hearing thresholds at extended high frequencies (EHF; above 8 kHz) is of clinical interest but is technically complicated by limitations in standard BC transducer output, a lack of calibration standards and sparse clinical data from human subjects. A recently described calibration scheme using an artificial mastoid and interposed accelerometer is applied in this study to characterize and compare acceleration and computed force outputs over the 4-20 kHz range of two standard BC transducers: the RadioEar® B71 and B81, as well as two non-standard, commercially available BC transducers: the Tascam® HP-F200 and the Aftershokz® AS400. Measures of linear output growth, harmonic distortion and acoustic radiation are assessed and compared across devices. A maximum linear input voltage is established for each BC transducer using measurements of linear output growth and total harmonic distortion. At maximum linear input level, the Tascam shows superior force output by 25 to 40 dB above 8 kHz and the widest dynamic EHF range. Acoustic radiation per output force was lowest for the Tascam, whereas the AS400 behaved more like an air conduction earphone than a force generator. In a cohort of 15 normal hearing volunteers, BC thresholds, measured with the Tascam and reported in dB re 1 rms µN, were consistent with historical measures of EHF BC thresholds in similar subjects using an alternative BC transducer.


Assuntos
Audiometria , Condução Óssea , Humanos , Limiar Auditivo , Audição , Transdutores
5.
Am J Audiol ; 31(3): 613-632, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35767328

RESUMO

PURPOSE: Characterizing and comparing speech recognition development in children with cochlear implants (CIs) is challenging because of variations in test type. This retrospective cohort study modified the Pediatric Ranked Order Speech Perception (PROSPER) scoring system to (a) longitudinally analyze the speech perception of children with CIs and (b) examine the role of age at CI activation, listening mode (i.e., unilateral or bilateral implantation), and interimplant interval. METHOD: Postimplantation speech recognition scores from 31 children with prelingual, severe-to-profound hearing loss who received CIs were analyzed (12 with unilateral CI [UniCI], 13 with sequential bilateral CIs [SEQ BiCIs], and six with simultaneous BiCIs). Data were extracted from the Massachusetts Eye and Ear Audiology database. A version of the PROSPER score was modified to integrate the varying test types by mapping raw scores from different tests into a single score. The PROSPER scores were used to construct speech recognition growth curves of the implanted ears, which were characterized by the slope of the growth phase, the time from activation to the plateau onset, and the score at the plateau. RESULTS: While speech recognition improved considerably for children following implantation, the growth rates and scores at the plateau were highly variable. In first implanted ears, later implantation was associated with poorer scores at the plateau (ß = -0.15, p = .01), but not growth rate. The first implanted ears of children with BiCIs had better scores at the plateau than those with UniCI (ß = 0.59, p = .02). Shorter interimplant intervals in children with SEQ BiCIs promoted faster speech recognition growth of the first implanted ears. CONCLUSION: The modified PROSPER score could be used clinically to track speech recognition development in children with CIs, to assess influencing factors, and to assist in developing and evaluating patient-specific intervention strategies. SUPPLEMENTAL MATERIAL: https://doi.org/10.23641/asha.20113538.


Assuntos
Implante Coclear , Implantes Cocleares , Percepção da Fala , Criança , Cognição , Humanos , Estudos Retrospectivos , Percepção da Fala/fisiologia , Resultado do Tratamento
6.
Bioconjug Chem ; 33(4): 608-624, 2022 04 20.
Artigo em Inglês | MEDLINE | ID: mdl-35290735

RESUMO

Tetrazines (Tz) have been applied as bioorthogonal agents for various biomedical applications, including pretargeted imaging approaches. In radioimmunoimaging, pretargeting increases the target-to-background ratio while simultaneously reducing the radiation burden. We have recently reported a strategy to directly 18F-label highly reactive tetrazines based on a 3-(3-fluorophenyl)-Tz core structure. Herein, we report a kinetic study on this versatile scaffold. A library of 40 different tetrazines was prepared, fully characterized, and investigated with an emphasis on second-order rate constants for the reaction with trans-cyclooctene (TCO). Our results reveal the effects of various substitution patterns and moreover demonstrate the importance of measuring reactivities in the solvent of interest, as click rates in different solvents do not necessarily correlate well. In particular, we report that tetrazines modified in the 2-position of the phenyl substituent show high intrinsic reactivity toward TCO, which is diminished in aqueous systems by unfavorable solvent effects. The obtained results enable the prediction of the bioorthogonal reactivity and thereby facilitate the development of the next generation of substituted aryltetrazines for in vivo applications.


Assuntos
Diagnóstico por Imagem , Linhagem Celular Tumoral , Solventes
7.
Trends Hear ; 26: 23312165211060983, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35018875

RESUMO

Cochlear implant programming typically involves measuring electrode impedance, selecting a speech processing strategy and fitting the dynamic range of electrical stimulation. This study retrospectively analyzed a clinical dataset of adult cochlear implant recipients to understand how these variables relate to speech recognition. Data from 425 implanted post-lingually deafened ears with Advanced Bionics devices were analyzed. A linear mixed-effects model was used to infer how impedance, programming and patient factors were associated with monosyllabic word recognition scores measured in quiet. Additional analyses were conducted on subsets of data to examine the role of speech processing strategy on scores, and the time taken for the scores of unilaterally implanted patients to plateau. Variation in basal impedance was negatively associated with word score, suggesting importance in evaluating the profile of impedance. While there were small, negative bivariate correlations between programming level metrics and word scores, these relationships were not clearly supported by the model that accounted for other factors. Age at implantation was negatively associated with word score, and duration of implant experience was positively associated with word score, which could help to inform candidature and guide expectations. Electrode array type was also associated with word score. Word scores measured with traditional continuous interleaved sampling and current steering speech processing strategies were similar. The word scores of unilaterally implanted patients largely plateaued within 6-months of activation. However, there was individual variation which was not related to initially measured impedance and programming levels.


Assuntos
Implante Coclear , Implantes Cocleares , Percepção da Fala , Adulto , Impedância Elétrica , Humanos , Estudos Retrospectivos , Percepção da Fala/fisiologia
8.
Ann Otol Rhinol Laryngol ; 131(3): 233-238, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34036833

RESUMO

OBJECTIVE: To characterize the prevalence, imaging characteristics, and cochlear implant candidacy of pediatric patients with single-sided deafness (SSD). METHODS: An audiometric database of patients evaluated at a large tertiary academic medical center was retrospectively queried to identify pediatric patients (<18 years old) with SSD, defined as severe to profound sensorineural hearing loss in one ear and normal hearing in the other. Medical records of identified patients were reviewed to characterize the prevalence, etiology, and cochlear implant candidacy of pediatric patients with SSD. RESULTS: We reviewed audiometric data obtained from 1993 to 2018 for 52,878 children at our institution. 191 (0.36%) had the diagnosis of SSD. Cochlear nerve deficiency (either hypoplasia or aplasia) diagnosed on MRI and/or CT was the most common etiology of SSD and was present in 22 of 88 (25%) pediatric SSD patients with available imaging data. 70 of 106 (66%) pediatric SSD patients with available imaging had anatomy amenable to cochlear implantation. CONCLUSIONS: Pediatric SSD is a rare condition and the most common etiology based on radiology is cochlear nerve deficiency. High resolution imaging of the temporal bone is essential to determine cochlear nerve morphology prior to consideration of cochlear implantation.


Assuntos
Perda Auditiva Neurossensorial/diagnóstico , Perda Auditiva Neurossensorial/epidemiologia , Perda Auditiva Unilateral/diagnóstico , Perda Auditiva Unilateral/epidemiologia , Criança , Pré-Escolar , Implante Coclear , Implantes Cocleares , Feminino , Perda Auditiva Neurossensorial/terapia , Perda Auditiva Unilateral/terapia , Testes Auditivos , Humanos , Imageamento por Ressonância Magnética , Masculino , Prevalência , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
9.
Otolaryngol Head Neck Surg ; 166(3): 523-529, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34003698

RESUMO

OBJECTIVE: The aim of this study was to evaluate the hearing outcome of cochlear implantation in patients deafened by Ménière's disease. STUDY DESIGN: Retrospective single-institution study. SETTING: Tertiary medical center. METHODS: Our institutional database of 1400 patients with cochlear implants was reviewed to identify cases with deafness due to Ménière's disease. Twenty-nine patients were identified: 24 with unilateral and 5 with sequential bilateral cochlear implants. Pre- and postoperative speech recognition scores and medical data were extracted from the medical record and analyzed. RESULTS: Overall the mean difference between pre- and postoperative speech recognition after >1 year was 56% (95% CI, 47.08%-64.92%). The mean preoperative monosyllabic word score was 9.5%, and the mean postoperative scores at 1 month, 3 months, 6 months, 1 year, and >1 year were 37.1%, 46.1%, 54.1%, 59.1%, and 66.8%, respectively. Cochlear implantation resulted in improved word scores in all patients regardless of prior medical or surgical treatment (endolymphatic sac, labyrinthectomy). The mean postoperative hearing improvement in patients aged <70 and ≥70 years was 65.26% (95% CI, 54.79%-75.73%) and 40.00% (95% CI, 27.22%-52.77%). Postoperative word scores in patients with bilateral cochlear implants were not significantly different between the first and second implanted ears or between the monoaural and binaural testing conditions. CONCLUSION: Cochlear implant in patients deafened by Ménière's disease significantly improves word recognition scores regardless of whether medical or surgical treatment is used prior to implantation. The potential improvement in word recognition scores decreases after age 70 years.


Assuntos
Implante Coclear , Implantes Cocleares , Saco Endolinfático , Perda Auditiva Neurossensorial , Doença de Meniere , Percepção da Fala , Implante Coclear/métodos , Audição , Perda Auditiva Neurossensorial/cirurgia , Humanos , Doença de Meniere/complicações , Doença de Meniere/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
10.
Otolaryngol Head Neck Surg ; 167(1): 178-182, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-34520270

RESUMO

OBJECTIVE: To assess the effectiveness and outcomes of a targeted cytomegalovirus (CMV) testing protocol. STUDY DESIGN: Retrospective chart review. SETTING: Tertiary care institution. METHODS: Targeted screening for CMV in children who did not pass the newborn hearing screening (NHS) was introduced in July 2015 for the level 2 and 3 nurseries at our hospital. In January 2016, this policy was extended to include all nurseries. Retrospective chart review was performed for all newborns who did not pass their NHS between 2013 and 2020. CMV testing rates and related outcomes were compared before and after rollout. RESULTS: A total of 891 charts were reviewed for infants who did not pass their NHS: 530 (60%) had CMV testing, of which 8 (1.5%) tested positive. Three cases were detected prior to and 5 occurred after initiation of targeted screening. Six CMV+ infants demonstrated hearing loss on confirmatory auditory brainstem response, all of whom began treatment with oral valganciclovir. Hearing remained stable in 3 patients, progressed in 2, and improved in 1. The rate of CMV testing in children who did not pass their NHS increased from 14% to 88% after full implementation of targeted screening (P < .001). The average age at initial infectious disease consultation was significantly younger for infants born after targeted screening (P < .001). CONCLUSION: Targeted screening is a feasible and effective method to identify CMV+ infants early in life. Implementation of a targeted screening program for CMV in children who do not pass the NHS resulted in significantly higher rates of CMV testing and earlier referral to infectious disease.


Assuntos
Infecções por Citomegalovirus , Perda Auditiva Neurossensorial , Criança , Citomegalovirus , Infecções por Citomegalovirus/congênito , Infecções por Citomegalovirus/diagnóstico , Infecções por Citomegalovirus/tratamento farmacológico , Perda Auditiva Neurossensorial/diagnóstico , Testes Auditivos , Humanos , Lactente , Recém-Nascido , Triagem Neonatal/métodos , Estudos Retrospectivos
11.
Ear Hear ; 42(6): 1741-1754, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34282087

RESUMO

OBJECTIVES: Factors contributing to auditory brainstem implant (ABI) outcomes are poorly understood. The aims of this study are to (1) characterize ABI electrode array position on postoperative imaging and (2) determine if variability in position is related to perceptual outcomes. DESIGN: Retrospective cohort study. Subjects were selected from the adult ABI recipient population at Massachusetts Eye and Ear. Postoperative three-dimensional (3D) computed tomography (CT) reconstruction of the head was used to measure ABI array position in 20 adult ABI recipients (17 with Neurofibromatosis Type 2 (NF2) and three non-NF2 recipients). Three-dimensional electrode array position was determined based on angles from the horizontal using posterior and lateral views and on distances between the proximal array tip superiorly from the basion (D1), laterally (D2P) and posteriorly (D2L) from the midline. Array position was correlated with perceptual data (in 15 of the 20 recipients who used their ABI). Perceptual data included the number of electrodes that provided auditory sensation, location and type of side effects, level of speech perception (from no sound to open-set word recognition of monosyllables) and the amount of charge required for auditory perception. RESULTS: Although the 3D orientation of the ABI array exhibited a variety of angles, all arrays were posteriorly tilted from the lateral view and most were medially tilted from the posterior view. ABI position relative to the basion from posterior showed mean distances of 1.71 ± 0.42 and 1.1 ± 0.29 cm for D1 and D2, respectively, and a mean D2 of 1.30 ± 0.45 cm from the lateral view. A strong linear negative correlation was found between the number of active electrodes and the distance of the proximal array tip laterally from the basion (D2P; rs = -0.73, p = 0.006) when measured in the posterior view. Although side effects were experienced in all recipients and varied in type and location across the array, electrodes in the middle part of the array tended to elicit auditory sensations while the proximal and distal tips of the array tended to elicit nonauditory side effects. Arrays with and without low charge thresholds appeared to generally overlap in position. However, the two recipients with the best (open-set) speech perception had low charge thresholds and had arrays that were tilted superiorly in the posterior view. CONCLUSION: ABI recipients with better speech perception appear to share a profile of arrays that are tilted superiorly as compared to recipients with lower speech perception levels. These ABI recipients have a high number of active electrodes (10 or more) and require less electrical charge on individual electrodes to achieve optimal stimulation.


Assuntos
Implante Auditivo de Tronco Encefálico , Implantes Auditivos de Tronco Encefálico , Neurofibromatose 2 , Percepção da Fala , Adulto , Implante Auditivo de Tronco Encefálico/métodos , Eletrodos , Humanos , Neurofibromatose 2/complicações , Neurofibromatose 2/diagnóstico por imagem , Neurofibromatose 2/cirurgia , Estudos Retrospectivos , Percepção da Fala/fisiologia , Tomografia Computadorizada por Raios X
12.
Ear Hear ; 42(5): 1295-1305, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33625057

RESUMO

OBJECTIVES: Current methods of diagnosing superior semicircular canal dehiscence syndrome (SCDS) include a clinical exam, audiometric testing, temporal bone computer tomography (CT) imaging, and vestibular evoked myogenic potential (VEMP) testing. The main objective of this study was to develop an improved diagnostic approach to SCDS optimized for accuracy, efficiency, and safety that utilizes clinical presentation, audiometric testing, CT imaging, high-frequency cervical VEMP (cVEMP) testing, and patient treatment preference. A secondary aim was to investigate the cost associated with the current versus proposed diagnostic paradigms. DESIGN: All patients who underwent cVEMP testing since introduction of the 2 kHz cVEMP in our clinical protocol in July 2018 were screened. Patients suspected of SCDS based upon symptoms who also had available audiogram, CT scan, and 2 kHz cVEMP were included (58 ears). Patients were categorized as dehiscent, thin, or not dehiscent based on their CT scan. Symptom prevalence and cVEMP outcomes were analyzed and compared for all groups. The accuracy of the 2 kHz cVEMP was calculated using CT imaging as the standard. Using a combination of patient symptomatology, audiometric, CT and 2 kHz cVEMP data, as well as patient preference, a best clinical practice approach was developed. The cost associated with this approach was calculated and compared with cost of the current SCDS diagnostic workup using Medicare reimbursement rates. RESULTS: In the overall patient population suspected of SCDS based on clinical presentation, the sensitivity and specificity of 2 kHz cVEMP were 76% and 100%, respectively, while the positive and negative predictive values were 100% and 84.6%, assuming that the CT scan finding was correct. Autophony was the most common symptom in patients who had both superior semicircular canal dehiscence on CT imaging plus abnormal 2 kHz cVEMP (p < 0.001). Combining patient symptomatology, 2 kHz normalized peak to peak cVEMP amplitude, and patient treatment preference to determine, which patients should undergo CT scanning resulted in a potential cost reduction between 45% and 61%. CONCLUSION: In patients suspected of SCDS based on their clinical presentation, the combination of symptomatology, 2 kHz cVEMP data, and patient preference can be used to determine which patients should undergo CT scanning, resulting in a diagnostic cost reduction and reduced patient radiation exposure.


Assuntos
Deiscência do Canal Semicircular , Potenciais Evocados Miogênicos Vestibulares , Idoso , Humanos , Medicare , Estudos Retrospectivos , Canais Semicirculares/diagnóstico por imagem , Osso Temporal/diagnóstico por imagem , Estados Unidos
13.
J Am Chem Soc ; 142(45): 19132-19141, 2020 11 11.
Artigo em Inglês | MEDLINE | ID: mdl-33119297

RESUMO

Bioorthogonal chemistry is bridging the divide between static chemical connectivity and the dynamic physiologic regulation of molecular state, enabling in situ transformations that drive multiple technologies. In spite of maturing mechanistic understanding and new bioorthogonal bond-cleavage reactions, the broader goal of molecular ON/OFF control has been limited by the inability of existing systems to achieve both fast (i.e., seconds to minutes, not hours) and complete (i.e., >99%) cleavage. To attain the stringent performance characteristics needed for high fidelity molecular inactivation, we have designed and synthesized a new C2-symmetric trans-cyclooctene linker (C2TCO) that exhibits excellent biological stability and can be rapidly and completely cleaved with functionalized alkyl-, aryl-, and H-tetrazines, irrespective of click orientation. By incorporation of C2TCO into fluorescent molecular probes, we demonstrate highly efficient extracellular and intracellular bioorthogonal disassembly via omnidirectional tetrazine-triggered cleavage.


Assuntos
Ciclo-Octanos/química , Sondas Moleculares/química , Anticorpos/química , Anticorpos/metabolismo , Carbono/química , Química Click , Corantes Fluorescentes/química , Isomerismo
14.
Laryngoscope ; 130(2): 507-513, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31095742

RESUMO

OBJECTIVE: Electrically evoked auditory brainstem responses (EABR) guide placement of the multichannel auditory brainstem implant (ABI) array during surgery. EABRs are also recorded under anesthesia in nontumor pediatric ABI recipients prior to device activation to confirm placement and guide device programming. We examine the influence of anesthesia on evoked response morphology in pediatric ABI users by comparing intraoperative with postoperative EABR recordings. STUDY DESIGN: Retrospective review. METHODS: Seven children underwent ABI surgery by way of retrosigmoid craniotomy. General anesthesia included inhaled sevoflurane induction and propofol maintenance during which EABRs were recorded to confirm accurate positioning of the ABI. A mean of 7.7 ± 2.8 weeks following surgery, the ABI was activated under general anesthesia or sedation (dexmedetomidine) and EABR recordings were made. A qualitative analysis of intraoperative and postoperative waveform morphology was performed. RESULTS: Seven subjects (mean age 20.6 months) underwent nine ABI surgeries (seven primary, two revisions) and nine activations. EABRs were observed in eight of nine postoperative recordings. In three cases, intraoperative EABRs during general anesthesia were similar to postoperative EABRs with sedation. In one case, sevoflurane and propofol were used for intra- and postoperative recordings, and waveforms were also similar. In four cases, amplitude and latency changes were observed for intraoperative versus postoperative EABRs. CONCLUSION: Similarity of EABR morphology in the anesthetized versus sedated condition suggests that anesthesia does not have a large effect on far-field evoked potentials. Changes in EABR waveform morphology observed postoperatively may be influenced by other factors such as movements of the surface array. LEVEL OF EVIDENCE: 4 Laryngoscope, 130:507-513, 2020.


Assuntos
Anestésicos/farmacologia , Implantes Auditivos de Tronco Encefálico , Potenciais Evocados Auditivos do Tronco Encefálico/efeitos dos fármacos , Implantação de Prótese/métodos , Anestesia Geral , Anestésicos Inalatórios/administração & dosagem , Anestésicos Intravenosos/administração & dosagem , Sedação Consciente , Feminino , Humanos , Lactente , Masculino , Propofol/administração & dosagem , Estudos Retrospectivos , Sevoflurano/administração & dosagem
15.
Otol Neurotol ; 40(10): 1346-1352, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31568134

RESUMO

OBJECTIVE: To investigate if the cervical vestibular evoked myogenic potential (cVEMP) is predictive for developing bilateral Menière's disease (MD). STUDY DESIGN: Retrospective cohort study. SETTING: Tertiary care center. PATIENTS: Records of 71 patients previously diagnosed with unilateral MD at our institution who underwent cVEMP testing between 2002 and 2011 were screened. INTERVENTION: Patients were contacted to answer a questionnaire to identify which patients had developed bilateral disease. Based on questionnaires and medical charts, 49 patients with a follow-up time of at least 5 years were included. The 49 originally asymptomatic ears are referred to as "study ears." Previously reported cVEMP criteria (original criteria) applied to study-ear cVEMPs separated them into Menière-like and normal-like groups. MAIN OUTCOME MEASURE: The main purpose was to determine if previously obtained cVEMP thresholds and tuning ratios of unilateral MD patients could predict who develops bilateral disease. RESULTS: From the 49 included patients, 12 developed bilateral disease (24.5%). The study ears characterized by original cVEMP criteria as Menière-like were significantly more likely to develop bilateral disease compared with the normal-like study ears. The original criteria predicted development of bilateral disease with a positive predictive value (PPV) and negative predictive value (NPV) of 58.3% and 86.5% respectively. ROC curves were used to revise cVEMP criteria for predicting the progression to bilateral disease. A revised criterion combining three cVEMP metrics, reached a PPV and NPV of 85.7% and 93.7%. CONCLUSION: cVEMP threshold and tuning in unilateral MD patients are predictive of which patients will develop bilateral disease.


Assuntos
Doença de Meniere/diagnóstico , Potenciais Evocados Miogênicos Vestibulares , Vestíbulo do Labirinto/fisiopatologia , Adulto , Idoso , Audiometria , Limiar Auditivo , Progressão da Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Curva ROC , Estudos Retrospectivos , Inquéritos e Questionários
16.
Otol Neurotol ; 40(3): e215-e224, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30741899

RESUMO

OBJECTIVE: The cervical vestibular evoked myogenic potential (cVEMP) has been used to evaluate patients with Menière's disease (MD). Studied cVEMP metrics include: amplitude, threshold, frequency tuning, and interaural asymmetry ratio (IAR). However, few studies compared these metrics in the same set of MD patients, and methodological differences prevent such a comparison across studies. This study investigates the value of different cVEMP metrics in distinguishing one set of MD patients from age-matched controls. STUDY DESIGN: Prospective study. SETTING: Tertiary care center. PATIENTS: Thirty patients with definite unilateral MD and 23 age-matched controls were prospectively included. All underwent cVEMP testing at 500, 750, 1000, and 2000 Hz on each side. Ears were separated into three groups: affected MD, unaffected MD, and control. MAIN OUTCOME MEASURES: Sound level functions were obtained at each frequency, and normalized peak-to-peak amplitude (VEMPn), VEMP inhibition depth (VEMPid), threshold, frequency-tuning ratio, and IAR were calculated. For all metrics, the differentiation between MD and control ears was compared using receiver operating characteristic (ROC) curves. RESULTS: 500 Hz cVEMP threshold, VEMPn, and VEMPid were similarly good at distinguishing affected MD ears from healthy ears, with ROC area under the curves (AUCs) of more than 0.828 and optimal sensitivities and specificities of at least 80 and 70%. Combinations of these three metrics yielded slightly larger AUCs (>0.880). Tuning ratios and IAR were less effective in separating healthy from affected ears with AUCs ranging from 0.529 to 0.720. CONCLUSION: The cVEMP metrics most useful in distinguishing MD patients from healthy controls are threshold, VEMPn, and VEMPid, using 500 Hz stimuli.


Assuntos
Doença de Meniere/diagnóstico , Potenciais Evocados Miogênicos Vestibulares/fisiologia , Testes de Função Vestibular/métodos , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Curva ROC , Sensibilidade e Especificidade
17.
Ear Hear ; 40(4): 878-886, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30431457

RESUMO

OBJECTIVES: To determine the most effective method for normalizing cervical vestibular evoked myogenic potentials (cVEMPs). DESIGN: cVEMP data from 20 subjects with normal hearing and vestibular function were normalized using 16 combinations of methods, each using one of the 4 modes of electromyogram (EMG) quantification described below. All methods used the peak to peak value of an averaged cVEMP waveform (VEMPpp) and obtained a normalized cVEMP by dividing VEMPpp by a measure of the EMG amplitude. EMG metrics were obtained from the EMG within short- and long-duration time windows. EMG amplitude was quantified by its root-mean-square (RMS) or average full-wave-rectified (RECT) value. The EMG amplitude was used by (a) dividing each individual trace by the EMG of this specific trace, (b) dividing VEMPpp by the average RMS or RECT of the individual trace EMG, (c) dividing the VEMPpp by an EMG metric obtained from the average cVEMP waveform, or (d) dividing the VEMPpp by an EMG metric obtained from an average cVEMP "noise" waveform. Normalization methods were compared by the normalized cVEMP coefficient of variation across subjects and by the area under the curve from a receiver-operating-characteristic analysis. A separate analysis of the effect of EMG-window duration was done. RESULTS: There were large disparities in the results from different normalization methods. The best methods used EMG metrics from individual-trace EMG measurements, not from part of the average cVEMP waveform. EMG quantification by RMS or RECT produced similar results. For most EMG quantifications, longer window durations were better in producing receiver-operating-characteristic with high areas under the curve. However, even short window durations worked well when the EMG metric was calculated from the average RMS or RECT of the individual-trace EMGs. Calculating the EMG from a long-duration window of a cVEMP "noise" average waveform was almost as good as the individual-trace-EMG methods. CONCLUSIONS: The best cVEMP normalizations use EMG quantification from individual-trace EMGs. To have the normalized cVEMPs accurately reflect the vestibular activation, a good normalization method needs to be used.


Assuntos
Eletromiografia/métodos , Músculos do Pescoço/fisiologia , Potenciais Evocados Miogênicos Vestibulares/fisiologia , Adulto , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Adulto Jovem
18.
Otol Neurotol ; 39(9): 1153-1162, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30124614

RESUMO

OBJECTIVE: Evaluate the relationship between objective audiometric and vestibular tests and patient symptoms in superior canal dehiscence (SCD) syndrome. STUDY DESIGN: Retrospective chart review. SETTING: Tertiary care center. PATIENTS: Ninety-eight patients with SCD, preoperative threshold audiograms, cervical vestibular evoked myogenic potential (cVEMP) thresholds, and computed tomography (CT) imaging were included. Clinical reports were reviewed for self-reported SCD symptoms. Twenty-five patients completed the Hearing Handicap Inventory (HHI), Dizziness Handicap Inventory (DHI), Autophony Index (AI), and the 36-item Short Form Survey (SF-36). MAIN OUTCOME MEASURES: Correlations between preoperative low-frequency air-bone gap (ABG), cVEMP thresholds, and symptoms (including HHI, DHI, AI, and SF-36). Symptoms included hearing loss, aural fullness, autophony, hyperacusis, tinnitus, vertigo, imbalance and sound-, pressure and exercise provoked dizziness. Secondary outcome measure: Correlations between changes of objective and subjective measures before and after surgery. RESULTS: Patients who reported hearing loss had larger ABGs at 250 Hz than patients without subjective hearing loss (p = 0.001). ABGs and cVEMP thresholds did not correlate with any other symptom. No significant correlation was found between ABG or cVEMP threshold and the HHI, DHI, AI or Health Utility Value (derived from the SF-36 quality of life score). Following SCD surgery, ABG decreased (p < 0.001), cVEMP thresholds increased (p < 0.001) and overall symptoms, handicap scores and quality-of-life improved; however, there was no significant relationship between these measures. CONCLUSION: While threshold audiometry and cVEMP are important tools to diagnose SCD and monitor surgical outcomes, these measures showed no significant correlation with vestibular and most auditory symptoms or their severity.


Assuntos
Audiometria , Doenças do Labirinto/complicações , Doenças do Labirinto/diagnóstico , Potenciais Evocados Miogênicos Vestibulares , Adulto , Idoso , Audiometria/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Canais Semicirculares/patologia , Potenciais Evocados Miogênicos Vestibulares/fisiologia
19.
Ear Hear ; 39(6): 1199-1206, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29624541

RESUMO

OBJECTIVES: Cervical vestibular evoked myogenic potentials (cVEMP) indirectly reveal the response of the saccule to acoustic stimuli through the inhibition of sternocleidomastoid muscle electromyographic response. VEMP inhibition depth (VEMPid) is a recently developed metric that estimates the percentage of saccular inhibition. VEMPid provides both normalization and better accuracy at low response levels than amplitude-normalized cVEMPs. Hopefully, VEMPid will aid in the clinical assessment of patients with vestibulopatholgy. To calculate VEMPid a template is needed. In the original method, a subject's own cVEMP was used as the template, but this method can be problematic in patients who do not have robust cVEMP responses. We hypothesize that a "generic" template, created by assembling cVEMPs from healthy subjects, can be used to compute VEMPid, which would facilitate the use of VEMPid in subjects with pathological conditions. DESIGN: A generic template was created by averaging cVEMP responses from 6 normal subjects. To compare VEMPid calculations using a generic versus a subject-specific template, cVEMPs were obtained in 40 healthy subjects using 500, 750, and 1000 Hz tonebursts at sound levels ranging from 98 to 123 dB peSPL. VEMPids were calculated both with the generic template and with the subject's own template. The ability of both templates to determine whether a cVEMP was present or not was compared with receiver operating characteristic curves. RESULTS: No significant differences were found between VEMPid calculations using a generic template versus using a subject-specific template for all frequencies and sound levels. Based on the receiver operating characteristic curves, the subject-specific and generic template did an equally good job at determining threshold. Within limits, the shape of the generic template did not affect these results. CONCLUSIONS: A generic template can be used instead of a subject-specific template to calculate VEMPid. Compared with cVEMP normalized by electromyographic amplitudes, VEMPid is advantageous because it averages zero when there is no sound stimulus and it allows the accumulating VEMPid value to be shown during data acquisition as a guide to deciding when enough data has been collected.


Assuntos
Sáculo e Utrículo/fisiologia , Potenciais Evocados Miogênicos Vestibulares , Adulto , Análise de Variância , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Doenças Vestibulares/diagnóstico , Adulto Jovem
20.
Audiol Neurootol ; 23(6): 335-344, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30677753

RESUMO

BACKGROUND: The cervical vestibular evoked myogenic potential (cVEMP) test measures saccular and inferior vestibular nerve function. The cVEMP can be elicited with different frequency stimuli and interpreted using a variety of metrics. Patients with superior semicircular canal dehiscence (SCD) syndrome generally have lower cVEMP thresholds and larger amplitudes, although there is overlap with healthy subjects. The aim of this study was to evaluate which metric and frequency best differentiate healthy ears from SCD ears using cVEMP. METHODS: Twenty-one patients with SCD and 23 age-matched controls were prospectively included and underwent cVEMP testing at 500, 750, 1,000 and 2,000 Hz. Sound level functions were obtained at all frequencies to acquire threshold and to calculate normalized peak-to-peak amplitude (VEMPn) and VEMP inhibition depth (VEMPid). Third window indicator (TWI) metrics were calculated by subtracting the 250-Hz air-bone gap from the ipsilateral cVEMP threshold at each frequency. Ears of SCD patients were divided into three groups based on CT imaging: dehiscent, thin or unaffected. The ears of healthy age-matched control subjects constituted a fourth group. RESULTS: Comparing metrics at all frequencies revealed that 2,000-Hz stimuli were most effective in differentiating SCD from normal ears. ROC analysis indicated that for both 2,000-Hz cVEMP threshold and for 2,000-Hz TWI, 100% specificity could be achieved with a sensitivity of 92.0%. With 2,000-Hz VEMPn and VEMPid at the highest sound level, 100% specificity could be achieved with a sensitivity of 96.0%. CONCLUSION: The best diagnostic accuracy of cVEMP in SCD patients can be achieved with 2,000-Hz tone burst stimuli, regardless of which metric is used.


Assuntos
Estimulação Acústica/métodos , Doenças do Labirinto/diagnóstico , Canais Semicirculares/fisiopatologia , Potenciais Evocados Miogênicos Vestibulares/fisiologia , Vestíbulo do Labirinto/fisiopatologia , Adulto , Idoso , Audiometria de Tons Puros , Feminino , Humanos , Doenças do Labirinto/fisiopatologia , Masculino , Pessoa de Meia-Idade , Inibição Neural/fisiologia , Estudos Prospectivos , Valores de Referência , Sáculo e Utrículo/fisiopatologia , Espectrografia do Som , Nervo Vestibular/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA