Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Environ Health Perspect ; 128(12): 127007, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33300819

RESUMO

BACKGROUND: Despite the substantial role indoor exposure has played in heat wave-related mortality, few epidemiological studies have examined the health effects of exposure to indoor heat. As a result, knowledge gaps regarding indoor heat-health thresholds, vulnerability, and adaptive capacity persist. OBJECTIVE: We evaluated the role of indoor heat exposure on mortality and morbidity among the elderly (≥65 years of age) in Houston, Texas. METHODS: Mortality and emergency hospital admission data were obtained through the Texas Department of State Health Services. Summer indoor heat exposure was modeled at the U.S. Census block group (CBG) level using building energy models, outdoor weather data, and building characteristic data. Indoor heat-health associations were examined using time-stratified case-crossover models, controlling for temporal trends and meteorology, and matching on CBG of residence, year, month, and weekday of the adverse health event. Separate models were fitted for three indoor exposure metrics, for individual lag days 0-6, and for 3-d moving averages (lag 0-2). Effect measure modification was explored via stratification on individual- and area-level vulnerability factors. RESULTS: We estimated positive associations between short-term changes in indoor heat exposure and cause-specific mortality and morbidity [e.g., circulatory deaths, odds ratio per 5°C increase=1.16 (95% CI: 1.03, 1.30)]. Associations were generally positive for earlier lag periods and weaker across later lag periods. Stratified analyses suggest stronger associations between indoor heat and emergency hospital admissions among African Americans compared with Whites. DISCUSSION: Findings suggest excess mortality among certain elderly populations in Houston who are likely exposed to high indoor heat. We developed a novel methodology to estimate indoor heat exposure that can be adapted to other U.S. LOCATIONS: In locations with high air conditioning prevalence, simplified modeling approaches may adequately account for indoor heat exposure in vulnerable neighborhoods. Accounting for indoor heat exposure may improve the estimation of the total impact of heat on health. https://doi.org/10.1289/EHP6340.


Assuntos
Exposição Ambiental/estatística & dados numéricos , Resposta ao Choque Térmico , Temperatura Alta , Idoso , Idoso de 80 Anos ou mais , Feminino , Hospitalização/estatística & dados numéricos , Humanos , Masculino , Mortalidade/tendências , Texas
3.
Sci Total Environ ; 607-608: 623-632, 2017 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-28709096

RESUMO

The CO2 surface-atmosphere exchange of an unirrigated, extensive green roof in Berlin, Germany was measured by means of the eddy covariance method over a full annual cycle. The present analysis focusses on the cumulative green roof net ecosystem exchange of CO2 (NEE), on its seasonal variation and on green roof physiological characteristics by applying a canopy (A-gs) model. The green roof was a carbon sink with an annual cumulative NEE of -313gCO2m-2year-1, equivalent to -85gCm-2year-1. Three established CO2 flux gap-filling methods were applied to estimate NEE and to study the performance during different meteorological situations. A best estimate NEE time series was established, which chooses the gap filling method with the highest performance. During dry periods daytime carbon uptake was shown to decline linearly with substrate moisture below a threshold of 0.05m3m-3, whereas night-time respiration was unaffected by substrate moisture variation. The roof turned into a temporary C source during dry conditions in summer 2015. We conclude that the carbon uptake of the present green roof can be optimized when substrate moisture is kept above 0.05m3m-3.

4.
Sci Total Environ ; 577: 220-230, 2017 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-27810303

RESUMO

Green roofs are discussed as a promising type of green infrastructure to lower heat stress in cities. In order to enhance evaporative cooling, green roofs should ideally have similar Bowen ratio (ß=sensible heat flux/latent heat flux) characteristics such as rural sites, especially during summer periods with high air temperatures. We use the eddy-covariance (EC) method to quantify the energy balance of an 8600m2 extensive, non-irrigated green roof at the Berlin Brandenburg Airport, Germany over a full annual cycle. To understand the influence of water availability on green roof-atmosphere energy exchange, we studied dry and wet periods and looked into functional relationships between leaf area, volumetric water content (VWC) of the substrate, shortwave radiation and ß. The surface energy balance was dominated by turbulent heat fluxes in comparison to conductive substrate heat fluxes. The Bowen ratio was slightly below unity on average but highly variable due to ambient meteorology and substrate water availability, i.e. ß increased to 2 in the summer season. During dry periods mean daytime ß was 3, which is comparable to typical values of urban instead of rural sites. In contrast, mean daytime ß was 0.3 during wet periods. Following a summer wet period the green roof maximum daily evapotranspiration (ET) was 3.3mm, which is a threefold increase with respect to the mean summer ET. A multiple regression model indicated that the substrate VWC at the present site has to be >0.11m3m-3 during summer high insolation periods (>500Wm-2) in order to maintain favourable green roof energy partitioning, i.e. mid-day ß<1. The microclimate benefit of urban green roofs can be significantly optimised by using sustainable irrigation approaches.


Assuntos
Cidades , Conservação dos Recursos Naturais , Arquitetura de Instituições de Saúde , Estações do Ano , Temperatura , Berlim , Água
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...