Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
2.
Eur Arch Otorhinolaryngol ; 279(10): 4735-4743, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35041067

RESUMO

PURPOSE: The aim of this study was to evaluate the intracochlear position of the Slim Modiolar Electrode (SME) after insertion via the extended Round Window (eRW) approach, and to correlate this with residual hearing preservation and speech perception outcomes. METHODS: Twenty-three adult participants, consecutively implanted with the SME via the eRW approach, were included in this prospective, single-center, observational study. Electrode position was evaluated intra-operatively using X-ray fluoroscopy and TIM measurement, and post-operatively using ultra-high resolution CT. Residual hearing [threshold shift in PTA between pre- and post-operative measurement, relative hearing preservation (RHP%)] and speech perception were evaluated at 2 and 12 months after surgery. RESULTS: In each of the 23 participants, complete scala tympani positioning of the electrode array could be achieved. In one participant, an initial tip fold-over was corrected during surgery. Average age at implantation was 63.3 years (SD 13.3, range 28-76) and mean preoperative residual hearing was 81.5 dB. The average post-operative PTA threshold shift was 16.2 dB (SD 10.8) at 2 months post-operatively, corresponding with a RHP% score of 44% (SD 34.9). At 12 months, the average RHP% score decreased to 37%. Postoperative phoneme scores improved from 27.1% preoperatively, to 72.1% and 82.1% at 2 and 12 months after surgery, respectively. CONCLUSION: Use of the eRW approach results in an increased likelihood of complete scala tympani insertion when inserting the SME, with subsequent excellent levels of speech perception. However, residual hearing preservation was found to be moderate, possibly as a result of the extended round window approach, emphasizing that it is not an all-purpose approach for inserting this particular electrode array.


Assuntos
Implante Coclear , Implantes Cocleares , Adulto , Cóclea/cirurgia , Implante Coclear/métodos , Eletrodos Implantados , Seguimentos , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos
3.
Radiology ; 302(3): 605-612, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34874202

RESUMO

Background Histopathologic studies reported that cochlear implantation, a well-established means to treat severe-to-profound sensorineural hearing loss, may induce inflammation, fibrosis, and new bone formation (NBF) with possible impact on loss of residual hearing and hearing outcome. Purpose To assess NBF in vivo after cochlear implantation with ultra-high-spatial-resolution (UHSR) CT and its implication on long-term residual hearing outcome. Materials and Methods In a secondary analysis of a prospective single-center cross-sectional study, conducted between December 2016 and January 2018, patients with at least 1 year of cochlear implantation experience underwent temporal bone UHSR CT and residual hearing assessment. Two observers evaluated the presence and location of NBF independently, and tetrachoric correlations were used to assess interobserver reliability. In addition, the scalar location of each electrode was assessed. After consensus agreement, participants were classified into two groups: those with NBF (n = 83) and those without NBF (n = 40). The association between NBF and clinical parameters, including electrode design, surgical approach, and long-term residual hearing loss, was tested using the χ2 and Student t tests. Results A total of 123 participants (mean age ± standard deviation, 63 years ± 13; 63 women) were enrolled. NBF was found in 83 of the 123 participants (68%) at 466 of 2706 electrode contacts (17%). Most NBFs (428 of 466, 92%) were found around the 10 most basal contacts, with an interobserver agreement of 86% (2297 of 2683 contacts). Associations between electrode types and surgical approaches were significant (58 of 79 participants with NBF and a precurved electrode vs 24 of 43 with NBF and a straight electrode, P = .04; 64 of 88 participants with NBF and a cochleostomy approach vs 18 of 34 with NBF and a round window approach, P = .03). NBF was least often seen in full scala tympani insertions, but there was no significant association between scalar position and NBF (P = .15). Long-term residual hearing loss was significantly larger in the group with NBF compared with the group without NBF (mean, 22.9 dB ± 14 vs 8.6 dB ± 18, respectively; P = .04). Conclusion In vivo detection of new bone formation (NBF) after cochlear implantation is possible by using ultra-high-spatial-resolution CT. Most cochlear implant recipients develop NBF, predominately located at the base of the cochlea. NBF adversely affects long-term residual hearing preservation. © RSNA, 2021 An earlier incorrect version appeared online. This article was corrected on December 8, 2021.


Assuntos
Implante Coclear , Osteogênese , Osso Temporal/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Estudos Transversais , Feminino , Testes Auditivos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
4.
Ear Hear ; 42(4): 949-960, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33480623

RESUMO

OBJECTIVES: The primary objective of this study is to identify the biographic, audiologic, and electrode position factors that influence speech perception performance in adult cochlear implant (CI) recipients implanted with a device from a single manufacturer. The secondary objective is to investigate the independent association of the type of electrode (precurved or straight) with speech perception. DESIGN: In a cross-sectional study design, speech perception measures and ultrahigh-resolution computed tomography scans were performed in 129 experienced CI recipients with a postlingual onset of hearing loss. Data were collected between December 2016 and January 2018 in the Radboud University Medical Center, Nijmegen, the Netherlands. The participants received either a precurved electrode (N = 85) or a straight electrode (N = 44), all from the same manufacturer. The biographic variables evaluated were age at implantation, level of education, and years of hearing loss. The audiometric factors explored were preoperative and postoperative pure-tone average residual hearing and preoperative speech perception score. The electrode position factors analyzed, as measured from images obtained with the ultrahigh-resolution computed tomography scan, were the scalar location, angular insertion depth of the basal and apical electrode contacts, and the wrapping factor (i.e., electrode-to-modiolus distance), as well as the type of electrode used. These 11 variables were tested for their effect on three speech perception outcomes: consonant-vowel-consonant words in quiet tests at 50 dB SPL (CVC50) and 65 dB SPL (CVC65), and the digits-in-noise test. RESULTS: A lower age at implantation was correlated with a higher CVC50 phoneme score in the straight electrode group. Other biographic variables did not correlate with speech perception. Furthermore, participants implanted with a precurved electrode and who had poor preoperative hearing thresholds performed better in all speech perception outcomes than the participants implanted with a straight electrode and relatively better preoperative hearing thresholds. After correcting for biographic factors, audiometric variables, and scalar location, we showed that the precurved electrode led to an 11.8 percentage points (95% confidence interval: 1.4-20.4%; p = 0.03) higher perception score for the CVC50 phonemes compared with the straight electrode. Furthermore, contrary to our initial expectations, the preservation of residual hearing with the straight electrode was poor, as the median preoperative and the postoperative residual hearing thresholds for the straight electrode were 88 and 122 dB, respectively. CONCLUSIONS: Cochlear implantation with a precurved electrode results in a significantly higher speech perception outcome, independent of biographic factors, audiometric factors, and scalar location.


Assuntos
Implante Coclear , Implantes Cocleares , Percepção da Fala , Adulto , Estudos Transversais , Humanos , Resultado do Tratamento
5.
Otol Neurotol ; 42(2): e124-e129, 2021 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-32941298

RESUMO

OBJECTIVES: The aim of this study is to report on our preliminary experience with Transimpedance Matrix (TIM)-measurement for the detection of cochlear implant electrode tip foldovers compared with intraoperative imaging in patients implanted with the slim modiolar electrode (SME). STUDY DESIGN: Proof of concept study. SETTING: Tertiary university referral center. PATIENTS: Twenty five ears (in 22 patients) implanted consecutively with the SME. INTERVENTIONS: Following cochlear implantation, intraoperative TIM-measurement and fluoroscopy were performed. One week postoperatively, the electrode position was evaluated using Computed Tomography (CT)-imaging. MAIN OUTCOME MEASURES: Electrode array tip foldover. RESULTS: Electrode array tip foldover occurred in three of the 25 cochlear implantations performed (12%). In each case, the foldover was detected by both TIM and fluoroscopy, leading to reposition and correct intracochlear placement of the array. CONCLUSIONS: TIM-measurement is a promising method for the intraoperative detection of an electrode array tip foldover. The TIM-tool with intuitive heatmap display is easy to use, fast, and readily available to clinics using TIM-software in the operating theatre.


Assuntos
Implante Coclear , Implantes Cocleares , Cóclea/cirurgia , Eletrodos Implantados , Humanos , Estudo de Prova de Conceito
6.
Comput Methods Programs Biomed ; 191: 105387, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32109685

RESUMO

BACKGROUND AND OBJECTIVE: Performing patient-specific, pre-operative cochlea CT-based measurements could be helpful to positively affect the outcome of cochlear surgery in terms of intracochlear trauma and loss of residual hearing. Therefore, we propose a method to automatically segment and measure the human cochlea in clinical ultra-high-resolution (UHR) CT images, and investigate differences in cochlea size for personalized implant planning. METHODS: 123 temporal bone CT scans were acquired with two UHR-CT scanners, and used to develop and validate a deep learning-based system for automated cochlea segmentation and measurement. The segmentation algorithm is composed of two major steps (detection and pixel-wise classification) in cascade, and aims at combining the results of a multi-scale computer-aided detection scheme with a U-Net-like architecture for pixelwise classification. The segmentation results were used as an input to the measurement algorithm, which provides automatic cochlear measurements (volume, basal diameter, and cochlear duct length (CDL)) through the combined use of convolutional neural networks and thinning algorithms. Automatic segmentation was validated against manual annotation, by the means of Dice similarity, Boundary-F1 (BF) score, and maximum and average Hausdorff distances, while measurement errors were calculated between the automatic results and the corresponding manually obtained ground truth on a per-patient basis. Finally, the developed system was used to investigate the differences in cochlea size within our patient cohort, to relate the measurement errors to the actual variation in cochlear size across different patients. RESULTS: Automatic segmentation resulted in a Dice of 0.90 ± 0.03, BF score of 0.95 ± 0.03, and maximum and average Hausdorff distance of 3.05 ± 0.39 and 0.32 ± 0.07 against manual annotation. Automatic cochlear measurements resulted in errors of 8.4% (volume), 5.5% (CDL), 7.8% (basal diameter). The cochlea size varied broadly, ranging between 0.10 and 0.28 ml (volume), 1.3 and 2.5 mm (basal diameter), and 27.7 and 40.1 mm (CDL). CONCLUSIONS: The proposed algorithm could successfully segment and analyze the cochlea on UHR-CT images, resulting in accurate measurements of cochlear anatomy. Given the wide variation in cochlear size found in our patient cohort, it may find application as a pre-operative tool in cochlear implant surgery, potentially helping elaborate personalized treatment strategies based on patient-specific, image-based anatomical measurements.


Assuntos
Cóclea/cirurgia , Implante Coclear , Aprendizado Profundo , Processamento de Imagem Assistida por Computador/métodos , Algoritmos , Humanos , Redes Neurais de Computação , Tomografia Computadorizada por Raios X
7.
Otolaryngol Head Neck Surg ; 162(4): 446-457, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32093572

RESUMO

OBJECTIVE: An increased interval between symptomatic disease and treatment may negatively influence oncologic and/or functional outcomes in head and neck cancer (HNC). This systematic review aims to provide insight into the effects of time to treatment intervals on oncologic and functional outcomes in oral cavity, pharyngeal, and laryngeal cancer. DATA SOURCES: PubMed, EMBASE, and Cochrane library were searched. REVIEW METHODS: All studies on delay or time to diagnosis or treatment in oral, pharyngeal, and laryngeal cancer were included. Quality assessment was performed with an adjusted version of the Newcastle-Ottawa scale. Outcomes of interest were tumor volume, stage, recurrence, survival, patient-reported outcome measures (PROMs), toxicity, and functionality after treatment. RESULTS: A total of 51 studies were included. Current literature on the influence of delay in HNC is inconsistent but indicates higher stage and worse survival with longer delay. The effects on PROMs, toxicity, and functional outcome after treatment have not been investigated. The inconsistencies in outcomes were most likely caused by factors such as heterogeneity in study design, differences in the definitions of delay, bias of results, and incomplete adjustment for confounding factors in the included studies. CONCLUSION: Irrespective of the level of evidence, the unfavorable effects of delay on oncologic, functional, and psychosocial outcomes are undisputed. Timely treatment while maintaining high-quality diagnostic procedures and decision making reflects good clinical practice in our opinion. This review will pose practical and logistic challenges that will have to be overcome.


Assuntos
Neoplasias Laríngeas/diagnóstico , Neoplasias Laríngeas/terapia , Neoplasias Bucais/diagnóstico , Neoplasias Bucais/terapia , Neoplasias Faríngeas/diagnóstico , Neoplasias Faríngeas/terapia , Tempo para o Tratamento , Humanos , Resultado do Tratamento
8.
Laryngoscope ; 130(11): E680-E685, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32022931

RESUMO

OBJECTIVES/HYPOTHESIS: To provide insight in the thermal effects of individual laser settings in target tissues to optimize flexible endoscopic CO2 laser surgery treatment. STUDY DESIGN: Experimental laboratory study. METHODS: Thermal effects of the CO2 laser using a fiber delivery system were visualized using the color Schlieren technique in combination with a polyacrylamide gel tissue model. Variable settings were used for emission mode, power, laser fiber distance, and laser duration, which were evaluated in every possible combination. Collateral thermal expansion and incision depth were measured. To validate the model, the results were compared to histology after CO2 laser irradiation of ex vivo human vocal cords, and the intraclass correlation coefficient was calculated. Thermal damage and incision depth were measured by a blinded pathologist. RESULTS: Of all parameters studied, duration of laser irradiation had the greatest effect on thermal expansion. Increased distance between laser tip and target tissue resulted in significantly reduced incision depth and increased thermal expansion. Pulsed emission modes led to increased incision depths. The intraclass correlation coefficient for consistency between the model setup and the ex vivo human vocal cords was classified as "fair." CONCLUSIONS: By using high-intensity pulsed lasers at minimal distance to the target tissue, exposure times and subsequent damage to surrounding tissue can be reduced. If an evaporation technique is used, lower power in continuous wave at a larger distance to the target tissue will lead to superficial but broader thermal effects. The model setup used in this study is a valid model to investigate laser-induced thermal effects in vocal cord tissue. LEVEL OF EVIDENCE: NA Laryngoscope, 130:E680-E685, 2020.


Assuntos
Procedimentos Cirúrgicos Ambulatórios/métodos , Laringoscopia/métodos , Lasers de Gás/uso terapêutico , Modelos Anatômicos , Prega Vocal/cirurgia , Dióxido de Carbono , Humanos , Condutividade Térmica
9.
Eur Arch Otorhinolaryngol ; 277(2): 343-350, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31650350

RESUMO

PURPOSE: In cochlear implantation (CI), the two factors that are determined by the surgeon with a potential significant impact on the position of the electrode within the cochlea and the potential outcome, are the surgical technique and electrode type. The objective of this prospective study was to evaluate the position of the slim, perimodiolar electrode (SPE), and to study the influence of the SPE position on CI outcome. METHODS: Twenty-three consecutively implanted, adult SPE candidates were included in this prospective cohort study conducted between December 2016 and April 2019. Mean age at surgery was 59.5 years. Mean preoperative residual hearing was 92.2 dB. Intra-operative fluoroscopy and high-resolution computed tomography scans were performed to evaluate electrode position after insertion using a cochleostomy (CS) approach. Follow-up was 12 months after implantation; residual hearing (6-8 weeks) and speech perception (6-8 weeks and 12 months) were evaluated in relation to the intracochlear SPE position. RESULTS: In most patients in whom the SPE was positioned in the scala tympani residual hearing was preserved [mean absolute increase in PTA of 4.4 dB and 77.2% relative hearing preservation (RHP%)]. Translocation into the scala vestibuli occurred in 36% of the insertions, resulting in a mean absolute increase in PTA of 17.9 dB, and a RHP% of 19.2%. Participants with a translocation had poorer speech perception scores at 12-month follow-up. CONCLUSION: Given the incidence of CS-associated translocations with the SPE and the negative effect on outcome, it is advised to insert the SPE using the (extended) round window approach.


Assuntos
Cóclea/cirurgia , Implante Coclear/métodos , Implantes Cocleares , Perda Auditiva/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Cóclea/diagnóstico por imagem , Implante Coclear/efeitos adversos , Implantes Cocleares/efeitos adversos , Tomografia Computadorizada de Feixe Cônico , Feminino , Fluoroscopia , Perda Auditiva/diagnóstico , Perda Auditiva/diagnóstico por imagem , Testes Auditivos , Humanos , Cuidados Intraoperatórios , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Falha de Prótese/etiologia , Janela da Cóclea/cirurgia , Rampa do Tímpano/cirurgia
10.
Otol Neurotol ; 40(7): 900-910, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31135680

RESUMO

OBJECTIVE: By discussing the design, findings, strengths, and weaknesses of available studies investigating the influence of angular insertion depth on speech perception, we intend to summarize the current status of evidence; and using evidence based conclusions, possibly contribute to the determination of the optimal cochlear implant (CI) electrode position. DATA SOURCES: Our search strategy yielded 10,877 papers. PubMed, Ovid EMBASE, Web of Science, and the Cochrane Library were searched up to June 1, 2018. Both keywords and free-text terms, related to patient population, predictive factor, and outcome measurements were used. There were no restrictions in languages or year of publication. STUDY SELECTION: Seven articles were included in this systematic review. Articles eligible for inclusion: (a) investigated cochlear implantation of any CI system in adults with post-lingual onset of deafness and normal cochlear anatomy; (b) investigated the relationship between angular insertion depth and speech perception; (c) measured angular insertion depth on imaging; and (d) measured speech perception at, or beyond 1-year post-activation. DATA EXTRACTION AND SYNTHESIS: In included studies; quality was judged low-to-moderate and risk of bias, evaluated using a Quality-in-Prognostic-Studies-tool (QUIPS), was high. Included studies were too heterogeneous to perform meta-analyses, therefore, effect estimates of the individual studies are presented. Six out of seven included studies found no effect of angular insertion depth on speech perception. CONCLUSION: All included studies are characterized by methodological flaws, and therefore, evidence-based conclusions regarding the influence of angular insertion depth cannot be drawn to date.


Assuntos
Implante Coclear/métodos , Implantes Cocleares , Surdez/cirurgia , Percepção da Fala/fisiologia , Adulto , Cóclea/cirurgia , Humanos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...