Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 85
Filtrar
1.
J Arthroplasty ; 38(11): 2316-2323.e1, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37286054

RESUMO

BACKGROUND: Total knee arthroplasties (TKAs) for patients aged ≤35 years are rare but necessary for patients who have diseases such as juvenile idiopathic arthritis, osteonecrosis, osteoarthritis, and rheumatoid arthritis. Few studies have examined the 10-year and 20-year survivorship and clinical outcomes of TKAs for young patients. METHODS: A retrospective registry review identified 185 TKAs in 119 patients aged ≤ 35 years performed between 1985 and 2010 at a single institution. The primary outcome was implant survivorship free of revision. Patient-reported outcomes were assessed at 2 time points: 2011 to 2012 and 2018 to 2019. The average age was 26 years (range, 12 to 35). Mean follow-up was 17 years (range, 8 to 33). RESULTS: Survivorship decreased from 84% (95% confidence interval [CI]: 79 to 90) at 5 years to 70% (95% CI: 64 to 77) at 10 years and to 37% (95% CI: 29 to 45) at 20 years. The most common reasons for revision were aseptic loosening (6%) and infection (4%). Risk factors for revision included increasing age at time of surgery (Hazards Ratio [HR] 1.3, P = .01) and use of constrained (HR 1.7, P = .05) or hinged prostheses (HR 4.3, P = .02). There were 86% of patients reporting that their surgery resulted in "a great improvement" or better. CONCLUSION: Survivorship of TKAs in young patients is less favorable than expected. However, for the patients who responded to our surveys, TKA demonstrated substantial pain relief and improvement in function at 17-year follow-up. Revision risk increased with older age and higher levels of constraint.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Humanos , Adulto , Artroplastia do Joelho/efeitos adversos , Prótese do Joelho/efeitos adversos , Estudos Retrospectivos , Sobrevivência , Falha de Prótese , Resultado do Tratamento , Reoperação , Articulação do Joelho/cirurgia , Desenho de Prótese
2.
J Arthroplasty ; 37(6S): S306-S312, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35210149

RESUMO

BACKGROUND: Antimicrobial resistance is recognized as a major public health threat. It occurs naturally; however, an excessive antibiotic use and misuse of antibiotics accelerate the process. Periprosthetic joint infections (PJI) are becoming harder to treat as the efficacy of antibiotics is becoming lower. The aim of this study was to compare the resistance of coagulase-negative staphylococci (CNS) to antibiotics identified after revision TKAs for PJI between two major orthopedic centers. METHODS: A review of all revision TKAs, undertaken between 2006 and 2018 in two orthopedic centers, was performed, including all those meeting the consensus criteria for PJI, in which CNS were identified. There were no major differences in surgical approach and tissue sampling between both centers. Thirteen commonly used antibiotics were tested at both centers. RESULTS: The 132 strains were analyzed for their resistance to 13 different antibiotics. Staphylococcus epidermidis was identified in 70.5% cultures, followed by Staphylococcus capitis in 8.3% cultures. The comparison of antibiotic resistance between two centers was statistically significant to penicillin (P = .001), oxacillin (P = .011), cefuroxime (P = .044), levofloxacin (P = .006), moxifloxacin (P = .008), tetracycline (P < .001), rifampicin (P < .001) and vancomycin (P < .001). The difference of resistance of CNS was not statistically significant to fosfomycin, clindamycin, teicoplanin, erythromycin and ampicillin. CONCLUSIONS: The resistance of CNS to antibiotics differs significantly between two major orthopedic centers that are geographically fairly close. Monitoring of bacteriological analyses in each referral center should be continuously performed. Close monitoring is needed for more efficient antibiotic treatment of and prophylaxis against PJI.


Assuntos
Artrite Infecciosa , Artroplastia do Joelho , Infecções Relacionadas à Prótese , Antibacterianos/uso terapêutico , Artrite Infecciosa/cirurgia , Artroplastia do Joelho/efeitos adversos , Coagulase/uso terapêutico , Farmacorresistência Bacteriana , Humanos , Infecções Relacionadas à Prótese/tratamento farmacológico , Infecções Relacionadas à Prótese/prevenção & controle , Infecções Relacionadas à Prótese/cirurgia , Estudos Retrospectivos , Staphylococcus
3.
Eur J Trauma Emerg Surg ; 48(3): 2309-2317, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34324007

RESUMO

PURPOSE: Goal of this study was the assessment of long-term outcome of arthroscopically assisted repair of Palmer 1B/Atzei 1 triangular fibrocartilage complex tears and the comparison with short- and mid-term results. METHODS: The study included nineteen patients (mean 49.2 years of age) with a mean follow-up time of 13.6 years (13.1-14.3 years). Examination parameters included disabilities of arm, shoulder, and hand (DASH) questionnaire, modified Mayo Wrist Score (MMWS), Krimmer Score, determination of range of motion in comparison to the contralateral extremity. Grip and pinch grip strength measurement and pain level assessment was performed, as well. RESULTS: The mean MMWS after at least 13.1 years was 95.8 (85-100, SD 5.6). Mean DASH Score was 10.2 (0-55.8, SD 13.6). Mean Krimmer Score was 97.2 (85-100, SD 4.8). Grip strength reached 101% of the contralateral unaffected hand. Range of motion did not differ significantly in comparison to the healthy contralateral extremity. None of the patients suffered from major complications. Fourteen of nineteen patients regarded pain level reduction as excellent. Five patients reported a relevant pain level reduction. Sixteen of nineteen patients regarded functional outcome as excellent, the other three patients reported on a pleasing improvement of the functional outcome. CONCLUSION: Arthroscopically assisted repair of Palmer 1B/Atzei 1 triangular fibrocartilage complex tears may be an efficacious and safe surgical technique for ulnar-sided TFCC tears in the long term.


Assuntos
Fibrocartilagem Triangular , Traumatismos do Punho , Artroscopia/métodos , Humanos , Dor/etiologia , Amplitude de Movimento Articular , Estudos Retrospectivos , Resultado do Tratamento , Fibrocartilagem Triangular/lesões , Fibrocartilagem Triangular/cirurgia , Traumatismos do Punho/cirurgia
4.
Arch Orthop Trauma Surg ; 140(11): 1819-1824, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32748043

RESUMO

INTRODUCTION: Tibial component design and positioning contribute more to patient satisfaction than previously realized. A surgeon needs to decide on the size and rotation, bearing in mind that coverage should be as high as possible, whilst malrotation and overhang should be avoided. No study investigates the impact of each of these components on clinical outcomes in a single cohort. MATERIALS AND METHODS: This is a retrospective analysis of 1-year postoperative outcomes measured with the Knee Injury and Osteoarthritis Outcome (KOOS) Score, as well as a previously validated rotational CT protocol. Coverage, rotation from Insall's axis, and overhang of an asymmetric tibial baseplate were measured, and positive and negative correlations to clinical outcomes were calculated. RESULTS: A total of 499 knees were analyzed. Patient average age was 68.4 years. Rotation within 7° internal and 5° external from Insall's axis was a "safe zone". Mean coverage was 76%. A total of 429 knees (94%) had a coverage of at least 70% and 102 knees (22%) greater than 80%. Overhang was detected in 23% of the cohort. Increased coverage was correlated to increased KOOS score and overhang correlated with a decreased KOOS score (p = 0.008). CONCLUSIONS: This study demonstrates the individual role of three aspects of tibial component implantation properties in postoperative pain and short-term functional outcomes. Upsizing to the point of overhang with rotational tolerance of 7° internal and 3° external to Insall's axis demonstrates best patient reported outcomes. Overhang decreases the clinical outcome by the same margin as loss of 16% of coverage.


Assuntos
Artroplastia do Joelho , Articulação do Joelho , Tíbia , Idoso , Humanos , Articulação do Joelho/fisiologia , Articulação do Joelho/cirurgia , Estudos Retrospectivos , Rotação , Tíbia/fisiologia , Tíbia/cirurgia , Resultado do Tratamento
5.
Technol Health Care ; 28(4): 415-423, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31796715

RESUMO

BACKGROUND: There is a clear tendency towards cementless acetabular components in primary total hip arthroplasty. OBJECTIVE: The aim of this study was to assess the long-term clinical and radiological outcome of titanium cementless acetabular cups when combined with a highly crosslinked polyethylene liner. METHODS: This study is a retrospective follow-up of 67 cups in 64 patients. Clinical outcomes were assessed using the Harris Hip Score. Radiolucent lines, osteolysis and loosening were assessed radiologically. Implant survival was determined using the Kaplan-Meier analysis. RESULTS: The average Harris Hip Score at follow-up was 80.3 ± 14.5. Signs of osteolysis were observed in 7.1% of the radiographs. No aseptic loosening of the cup was reported. Survival of the cup with aseptic loosening as an endpoint was 100%. A comparison with 19 other studies using the same material combination demonstrated very similar results. All manufacturers with available studies have at least one report of 100% survivorship at 10-year follow-up for their titanium cup and highly crosslinked polyethylene acetabular component combination with aseptic loosening as an endpoint. CONCLUSIONS: The data suggests that the rate of aseptic loosening of a titanium cup combined with a highly-crosslinked polyethylene liner at 10-year follow-up could be as low as 0%.


Assuntos
Acetábulo , Artroplastia de Quadril , Acetábulo/cirurgia , Seguimentos , Prótese de Quadril , Humanos , Polietileno , Desenho de Prótese , Falha de Prótese , Estudos Retrospectivos , Titânio
6.
Bone Joint Res ; 8(10): 472-480, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31728187

RESUMO

OBJECTIVES: Periprosthetic femoral fractures (PFFs) have a higher incidence with cementless stems. The highest incidence among various cementless stem types was observed with double-wedged stems. Short stems have been introduced as a bone-preserving alternative with a higher incidence of PFF in some studies. The purpose of this study was a direct load-to-failure comparison of a double-wedged cementless stem and a short cementless stem in a cadaveric fracture model. METHODS: Eight hips from four human cadaveric specimens (age mean 76 years (60 to 89)) and eight fourth-generation composite femurs were used. None of the cadaveric specimens had compromised quality (mean T value 0.4 (-1.0 to 5.7)). Each specimen from a pair randomly received either a double-wedged stem or a short stem. A materials testing machine was used for lateral load-to-failure test of up to a maximal load of 5000 N. RESULTS: Mean load at failure of the double-wedged stem was 2540 N (1845 to 2995) and 1867 N (1135 to 2345) for the short stem (p < 0.001). All specimens showed the same fracture pattern, consistent with a Vancouver B2 fracture. The double-wedged stem was able to sustain a higher load than its short-stemmed counterpart in all cases. Failure force was not correlated to the bone mineral density (p = 0.718). CONCLUSION: Short stems have a significantly lower primary load at failure compared with double-wedged stems in both cadaveric and composite specimens. Surgeons should consider this biomechanical property when deciding on the use of short femoral stem.Cite this article: A. Klasan, M. Bäumlein, P. Dworschak, C. Bliemel, T. Neri, M. D. Schofer, T. J. Heyse. Short stems have lower load at failure than double-wedged stems in a cadaveric cementless fracture model. Bone Joint Res 2019;8:489-494. DOI: 10.1302/2046-3758.810.BJR-2019-0051.R1.

7.
J Orthop Translat ; 18: 7-12, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31508302

RESUMO

INTRODUCTION: Studies using conventional radiographical signs and computerized tomography (CT) for retroversion of the acetabulum have reported a prevalence of up to 25%. The purpose of this study was to provide a detailed report on acetabular version, gender, age and side differences in a large cohort. MATERIALS AND METHODS: A total of 404 patients receiving a whole-body CT scan, aged between 16 and 40 years, have been included in the study. The measurement was performed in the transversal plane on three levels: cranial, central and caudal. RESULTS: The retroverted acetabulum on all three levels had a prevalence of 0.25% (95% confidence interval 0-0.7%). The average central anteversion in men was 16.46° (±4.42) and that in women was 19.31° (±5.04) (p < 0.001). Version increases with age, but a cluster analysis showed this to be a trend (p = 0.068). CONCLUSION: Women have a higher average acetabular version than men. Retroversion in a young adult population has a low prevalence when measured with conventional CT. About a tenth of the population has a significantly different contralateral acetabular version. THE TRANSLATIONAL POTENTIAL OF THIS ARTICLE: Global acetabular retroversion has a much lower prevalence than previously reported.

8.
Arch Orthop Trauma Surg ; 139(8): 1045-1049, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30770995

RESUMO

INTRODUCTION: Impingement of the prominent anterior inferior iliac spine (AIIS) against the femoral neck has recently been described as another type of impingement. The purpose of this study is to provide a distribution of AIIS types using the classification proposed by Hetsroni and thus report on the prevalence of prominent types. MATERIALS AND METHODS: A total of 400 patients were included in the study with an average age 27.3 ± 6.9 years (range 18-40). All patients received a whole-body polytrauma computer tomography (CT) scan in the emergency room (ER) upon arrival. The classification of AIIS proposed by Hetsroni et al., which describes three morphological types, was used. Type II and III were grouped as prominent types. The measurements were performed in all three planes by two examiners. RESULTS: Male to female ratio was 71:29. Type I was observed in 367 (91.7%) patients. Type II was observed in 31 (7.8%) patients and type III was observed in 2 (0.5%) patients, unilaterally. Prominent types were much more prevalent in men (10.5%) than in women (2.6%). The CT assessment demonstrated excellent intra- and interreliability (overall: 0.926, I/II: 0.906, III: 1.000). CONCLUSION: A young population demonstrates a prevalence of a prominent AIIS of 11.5%. Prominent AIIS is more common in men than in women.


Assuntos
Artralgia/fisiopatologia , Colo do Fêmur/fisiopatologia , Ílio/fisiopatologia , Artropatias/fisiopatologia , Adolescente , Adulto , Feminino , Colo do Fêmur/diagnóstico por imagem , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/fisiopatologia , Humanos , Ílio/diagnóstico por imagem , Imageamento Tridimensional , Artropatias/classificação , Artropatias/diagnóstico por imagem , Masculino , Prevalência , Fatores Sexuais , Tomografia Computadorizada por Raios X , Imagem Corporal Total , Adulto Jovem
9.
Arch Orthop Trauma Surg ; 139(1): 73-78, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30039308

RESUMO

INTRODUCTION: Although there is increasing evidence for the successful use of local vancomycin applied by soaked compresses during ACL reconstruction, there are still little data on its microbiological and biomechanical effects. Furthermore, exact dosage of vancomycin with respect to tendon stability and microbiological effectivity is still unknown. MATERIALS AND METHODS: 63 porcine flexor digitorum profundus tendons were harvested under sterile conditions from fresh cadaver legs. After contamination with Staphylococcus epidermidis (S. epidermidis), tendons were wrapped into sterile compresses moistened with different concentrations of vancomycin for 10 or 20 min. Sterile sodium chloride was used for control. After treatment, tendons were rolled onto blood-agar plates to test for residual bacterial contamination and tested for maximum load and stiffness using a uniaxial testing device with cryo-clamps for tendon fixation. Agar plates were checked after 1 week of culture at 36 °C for signs of bacterial growth. RESULTS: When applying vancomycin for only 10 min, bacterial contamination was found in all dosage groups ranging from 28.6% contamination (n = 2 of 7 tendons) when using 10 mg/ml up to 85.7% (n = 6 of 7 tendons) when using 1 mg/ml. Applying vancomycin-soaked compresses for 20 min, bacterial contamination was still found in the groups using 1 mg/ml and 2.5 mg/ml (contamination rate 85.7 and 42.9% respectively). When using 5 mg/ml and 10 mg/ml, no bacterial contamination could be perceived after 7 days of culture. With regard to biomechanical properties, no differences were found regarding maximum load or Young's modulus between groups. CONCLUSIONS: This study showed no signs of biomechanical impairment of porcine flexor tendons after the use of vancomycin wraps with concentration ranging from 1 to 10 mg/ml for 10 or 20 min at a time zero testing. Contamination with S. epidermidis was cleansed in 100% of tendons when using at least 5 mg/ml of vancomycin for 20 min.


Assuntos
Reconstrução do Ligamento Cruzado Anterior/métodos , Antibacterianos/farmacologia , Tendões , Vancomicina/farmacologia , Animais , Ligamento Cruzado Anterior/cirurgia , Fenômenos Biomecânicos/fisiologia , Staphylococcus epidermidis/efeitos dos fármacos , Suínos , Tendões/microbiologia , Tendões/fisiologia , Tendões/cirurgia , Tendões/transplante
10.
Int Orthop ; 43(3): 653-658, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30076444

RESUMO

PURPOSE: In this study, the total blood loss, transfusion rate and number of transfused blood units in patients with different indications for shoulder arthroplasty: primary, fracture and secondary were compared. Risk factors for bleeding and transfusion were analysed. METHODS: Medical records and the database of the institution's blood bank from 527 patients that received shoulder arthroplasty were analysed retrospectively. This study included 419 patients that were divided in three different groups: primary (n = 278), fracture (n = 110) and secondary (following prior osteosynthesis; n = 31) shoulder arthroplasty. The demographic and clinical data were collected. The total blood loss (TBL) was calculated and transfusions recorded. RESULTS: The transfusion rate and mean amount of transfused blood units (BU) were higher in fracture (32.7% and 0.69BU, p < 0.01) and secondary arthroplasty (35.5% and 0.97BU, p < 0.01) than in primary arthroplasty (12.6% and 0.28BU). The overall transfusion rate was 19.6% at a mean TBL of 370 ml. However, patients with primary arthroplasty experienced significantly higher total blood loss than those after fracture arthroplasty (p < 0.01). Longer surgery time and male sex are significant risk factors for elevated blood loss. The pre-operative use of vitamin K antagonist, cemented arthroplasty, high BMI, coronary heart disease and ASA score > 2 are relevant risk factors for blood transfusion. CONCLUSION: The most important susceptible factor that affects the TBL is the surgery time. Transfusion rates are higher in patients with fracture arthroplasty than after primary arthroplasty.


Assuntos
Artroplastia do Ombro , Perda Sanguínea Cirúrgica , Transfusão de Sangue , Artropatias/cirurgia , Hemorragia Pós-Operatória , Articulação do Ombro/cirurgia , Idoso , Artroplastia do Ombro/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco
11.
Arch Orthop Trauma Surg ; 138(9): 1317-1322, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30043147

RESUMO

INTRODUCTION: This stem was cleared by the FDA in 2002 and has been implanted in cementless and cemented versions. Despite its long history, there are no long-term clinical  results available for the cemented version of this implant. The aim of this study was to provide such data. It was hypothesized that this implant delivers clinical success comparable to other tapered cemented stems. MATERIALS AND METHODS: A total of 113 hip replacements were performed in 106 patients between October 2007 and December 2009 using the cemented version of this stem. The mean age of the patients at operation was 74.8 years (range 50-91 years). The mean follow-up was 8.9 years with only two patients lost to follow-up. Implant survival was determined using the Kaplan-Meier analysis. RESULTS: Stem survival with revision for any reason as the endpoint was 96.4% after 10 years. Survival for stem aseptic loosening was 100%. There were no cases of osteolysis. Clinical outcomes, as shown by Harris Hip Scores, were in line with previous investigations and the rate of adverse events was very low. CONCLUSIONS: This is a modern cemented stem with an excellent survival rate and satisfactory functional outcomes. In this cohort, there were no failures related to the stem through the first decade.


Assuntos
Artroplastia de Quadril/instrumentação , Cimentos Ósseos/uso terapêutico , Prótese de Quadril/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/métodos , Cimentos Ósseos/efeitos adversos , Feminino , Seguimentos , Articulação do Quadril/cirurgia , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese/efeitos adversos , Falha de Prótese/etiologia , Reoperação/estatística & dados numéricos , Resultado do Tratamento
13.
Technol Health Care ; 26(5): 825-832, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29914043

RESUMO

BACKGROUND: Knee and hip replacement surgery are still the mainstay therapy for osteoarthritis. In spite of the improvement of techniques and implants, anemia is a relatively common complication, with transfusion rates of up to 23% in some centers. OBJECTIVE: The purpose of the study was to determine a correlation of transfusions to complications including infection since this topic is still being debated or even disputed in the literature. METHODS: This is a level III, single center retrospective observational cohort study of 2760 unilateral primary knee and hip replacements. Preoperative assessment, the number of transfusions and the occurrence of complications were collected and the correlations were analyzed using analysis of variance and logistic regression. RESULTS: Fifteen percent of all patients developed at least one complication. Transfusion rate was 9%. Risk factors for receiving a transfusion were female gender, hip replacement, American Society of Anesthesiologists' Score (ASA) > III, history of myocardial infarction, chronic cardiac disease, diabetes mellitus, chronic kidney disease, and length of surgery. The risk factors for developing a complication were: ASA score, presence of chronic renal insufficiency, and transfusion during hospital stay. Transfusion increases the risk of complications and infection rate. Complication rate with transfusion was 34.7% and without transfusion 13.2%. Infection rate without transfusion was 0.4% and with transfusion 2.82%. CONCLUSIONS: The complication rate is higher in transfused patients. The number of complications rises linearly with the number of transfusions. Infection rate is also higher after a transfusion. Efforts should be made to reduce the transfusion rate.


Assuntos
Artroplastia de Quadril/métodos , Artroplastia do Joelho/métodos , Transfusão de Sangue/estatística & dados numéricos , Infecção da Ferida Cirúrgica/epidemiologia , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/efeitos adversos , Artroplastia do Joelho/efeitos adversos , Comorbidade , Feminino , Humanos , Tempo de Internação/estatística & dados numéricos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Complicações Pós-Operatórias/epidemiologia , Estudos Retrospectivos , Fatores de Risco , Fatores Sexuais
14.
Arch Orthop Trauma Surg ; 138(10): 1415-1421, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29802454

RESUMO

INTRODUCTION: The aim of the present study was to determine the incidence and type of complications during and after hip arthroscopy as well as the effect of the surgeon's learning curve on the occurrence of complications. We expect that the currently reported prevalence especially of minor complications is likely to be underreported in most retrospective series based on chart analysis. MATERIALS AND METHODS: The study included all consecutive patients who underwent hip arthroscopy between 2006 and 2014 at a minimum follow-up of 6 weeks starting with the first patient undergoing hip arthroscopy at the institution. Patient outcome was evaluated using the WOMAC score, VAS for pain, SF-36 questionnaire and the hip-outcome score. Additionally, intra- and postoperative complications were recorded via a questionnaire and additional review of patient files. RESULTS: We identified 529 patients who underwent hip arthroscopy between 2006 and 2014. Complete data could be gathered from 485 patients (91.7%). Major complications occurred in three patients (0.6%; fractures of the femoral neck requiring surgical treatment in one case). Minor complications that did not require further intervention were self-limiting postoperative temporary neurapraxia, hematoma, self-limiting dyspareunia, deep vein thrombosis and impaired wound healing, with hematoma and temporary paresthesia due to traction neurapraxia being the most common ones (22.5 and 16.4% respectively). The overall re-operation rate was 15.7% with conversion to total hip arthroplasty being the most common (11.9%). CONCLUSIONS: The overall major complication rate was low and thus hip arthroscopy can be rated as a safe procedure. But minor complications such as hematoma and temporary paresthesia due to traction neurapraxia are common and currently underreported. Surgeons' learning curves show a reduction of major complications once 60 procedures per surgeon per year is surpassed.


Assuntos
Artroscopia/efeitos adversos , Articulação do Quadril/cirurgia , Curva de Aprendizado , Cirurgiões/estatística & dados numéricos , Adulto , Artroscopia/estatística & dados numéricos , Feminino , Humanos , Masculino , Complicações Pós-Operatórias/epidemiologia , Reoperação , Estudos Retrospectivos
15.
Technol Health Care ; 26(3): 523-528, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29578494

RESUMO

BACKGROUND: An increasing demand for total knee arthroplasty (TKA) has pushed innovations in the industry and created a promising new technique called patient specific instruments (PSI). Early reports had promising results such as reducing operative time, cost, and improved alignment. More recent reports are conflicting. OBJECTIVE: We aimed to evaluate bleeding, operative time, complication rates, and in-hospital stay. METHODS: A monocentric retrospective analysis was performed on a total of 961 patients that met inclusion criteria. Four different TKA Systems, two of which were performed using conventional instrumentation (CI) (n= 768) and two with PSI (n= 193) were trialed under the same conditions by three senior surgeons. Operative time, complications, bleeding, range of motion, and length of stay were analyzed. RESULTS: There was no difference in operative time (p= 0.991) and length of hospital stay (p= 0.371) between PSI and CI approaches. Complication rates were lower in the PSI group. CI patients showed less non-compensated blood loss (p< 0.001) but required more transfusions (5.8% vs. 1.5%, p= 0.014). CONCLUSIONS: There was no difference in duration of surgery, length of stay, and total blood loss when performing TKA with PSI or CI. There were fewer complications in the PSI group. It remains debatable whether these findings justify routine use of PSI in TKA.


Assuntos
Artroplastia do Joelho/instrumentação , Artroplastia do Joelho/métodos , Idoso , Idoso de 80 Anos ou mais , Perda Sanguínea Cirúrgica , Feminino , Humanos , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Osteoartrite do Joelho/cirurgia , Complicações Pós-Operatórias/epidemiologia , Amplitude de Movimento Articular , Estudos Retrospectivos
16.
BMC Musculoskelet Disord ; 19(1): 8, 2018 01 09.
Artigo em Inglês | MEDLINE | ID: mdl-29316902

RESUMO

BACKGROUND: Ankle tape is widely used by athletes to prevent ankle sprain. Although there is growing evidence that ankle tape improve joint position sense, but yet it is not clear even if tape improve joint position sense after muscle fatigue, because fatigue impair joint position sense and raise the risk of ankle sprain. The aim of this study is to examine the effect of ankle tape on joint position sense after local muscle fatigue. METHOD: This trial is a randomized controlled trial. 34 healthy subjects participated in this trial. Subjects were randomized distributed into two groups: with tape and without tape. Active and passive absolute error and variable error mean values for two target positions of the ankle joint (15° inversions and inversion minus 5°) before and after fatigue protocol consisted of 30 consecutive maximal concentric/concentric contractions of the ankle evertors and invertors. In this trail joint position sense for all subjects was assessed using The Biodex System isokinetic dynamometer 3, this system is used also for fatigue protocol. RESULTS: For the variable error (VE), significant mean effect was found for active joint position sense in 15° of inversion after muscle fatigue (P < 0, 05). It was a significant decrease in the work in the last third of inversion detected (P < 0, 05). There was no significant main effect found for fatigue index of eversion. CONCLUSION: Ankle tape can improve joint position sense at the fatigue session when joint position sense becomes worse. As a result, ankle tape may be useful to prevent ankle sprain during playing sports. We suggest athletes and individuals at risk of ankle sprain to apply taping before high-load activity. TRIAL REGISTRATION: The study was retrospectively registered on the ISRCTN registry with study ID ISRCTN30042335 on 12th December 2017.


Assuntos
Articulação do Tornozelo/fisiologia , Fita Atlética/estatística & dados numéricos , Fadiga Muscular/fisiologia , Propriocepção/fisiologia , Adulto , Traumatismos do Tornozelo/fisiopatologia , Traumatismos do Tornozelo/prevenção & controle , Feminino , Humanos , Masculino , Resultado do Tratamento
17.
BMC Musculoskelet Disord ; 19(1): 9, 2018 01 09.
Artigo em Inglês | MEDLINE | ID: mdl-29316907

RESUMO

BACKGROUND: Chondrosarcoma is the second most common primary malignant bone tumor. Because of their heterogeneity, with differences in invasive and metastatic behavior, it is important to identify biological markers that will allow for a more accurate estimation of prognosis in patients with these tumors. Matrix metalloproteinases (MMP) play a crucial role in tumor progression, invasion and metastasis. The mechanism of tumor progression dependent of MMPs is complex and influences malignant transformation, angiogenesis and tumor growth at the primary and metastatic sites. The purpose of this study was to investigate immunohistochemicaly the influence of MMP-1, MMP-3, MMP-9 and MMP-13 expression on prognostic parameter in chondrosarcoma. METHODS: We investigated tissue samples of 28 patients with chondrosarcoma. Immunohistochemical staining to evaluate the expression of MMP-1, MMP-3, MMP-9 and MMP-13 was performed. Subsequently, the expression level was correlated with metastatic potential, histological grading and overall survival in patients with this neoplasm. RESULTS: In consideration of semi quantitative scoring 64% of chondrosarcoma were scored as positive for MMP-1, 46% for MMP-3, 61% for MMP-9. The specimens had shown no expression of MMP-13. High expression of MMP-9 was associated with better histological differentiation, decreased metastatic potential and favourable overall survival. No correlation was found for expression of MMP-1, MMP-3 or MMP-13. CONCLUSIONS: MMP-1, MMP-3 and MMP-9 are expressed in chondrosarcoma. Our findings suggest that the expression of MMP-9 is associated with clinical outcome parameters in chondrosarcoma.


Assuntos
Biomarcadores Tumorais/biossíntese , Neoplasias Ósseas/enzimologia , Condrossarcoma/enzimologia , Regulação Enzimológica da Expressão Gênica , Metaloproteinase 9 da Matriz/biossíntese , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores Tumorais/análise , Biomarcadores Tumorais/genética , Neoplasias Ósseas/diagnóstico , Neoplasias Ósseas/mortalidade , Condrossarcoma/diagnóstico , Condrossarcoma/mortalidade , Feminino , Seguimentos , Humanos , Imuno-Histoquímica , Masculino , Metaloproteinase 9 da Matriz/análise , Metaloproteinase 9 da Matriz/genética , Pessoa de Meia-Idade , Adulto Jovem
18.
Arch Orthop Trauma Surg ; 138(3): 317-323, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29214382

RESUMO

INTRODUCTION: The aim of this investigation was to analyse "total blood loss" (TBL), "blood transfusion rate" (BT) and the "amount of transfused blood units" (BU) between the different primary shoulder arthroplasty (SA) types: reverse, anatomical and stemless. Only primary SA was included. Further goal was to identify risk factors for TBL, amount of BU and BT rate. METHODS: A retrospective charts analysis of patients who received primary SA for degenerative shoulder pathology in our institution between 2004 and 2016 was performed. The demographic data, co-morbidities, haemoglobin and hematocrit level, BT rate, amount of transfused BU etc. were collected. TBL was estimated. Linear regression, log-linear poisson regression and logistic regression were used to compare the outcomes TBL, amount of transfused BU and BT rate, respectively, between different prosthesis types. RESULTS: Of 278 patients included in this study 209 received reverse, 57 anatomical and 12 stemless SA. Mean TBL was 392.7 ml in reverse, 394.6 ml in anatomical and 298.3 ml in stemless SA. The BT rate and mean amount of BU were, respectively, 14.4% and 0.32 in reverse and 8.77% and 0.23 in anatomical SA. None of the patients with stemless arthroplasty received BT. Significant risk factors for elevated TBL are operation time, higher BMI, male sex. Significant risk parameters for BT and higher amount of transfused BU are low BMI, cemented arthroplasty, coronary heart disease, ASA score > 2 and previous therapy with vitamin K antagonists. CONCLUSION: Although there were little differences between the blood transfusion rates in reverse vs. anatomical arthroplasty, there was no difference in total blood loss between these different prosthesis types. None of the patients with stemless arthroplasty received blood transfusion. There are various risk factors affecting total blood loss and blood transfusion rate. However, risk parameters influencing blood transfusion may be different to them affecting total blood loss.


Assuntos
Artroplastia do Ombro/métodos , Perda Sanguínea Cirúrgica , Transfusão de Sangue/estatística & dados numéricos , Idoso , Índice de Massa Corporal , Doença das Coronárias/epidemiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Estudos Retrospectivos , Fatores de Risco , Fatores Sexuais , Vitamina K/antagonistas & inibidores
19.
Knee Surg Sports Traumatol Arthrosc ; 26(6): 1767-1775, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29128876

RESUMO

PURPOSE: Femoral component malrotation in total knee arthroplasty (TKA) is clinically proven to cause dissatisfaction and impaired function. This study is an attempt to characterize the tibiofemoral kinematics following femoral malrotation in posterior stabilized (PS) TKA. It was hypothesized that internal malrotation would introduce the most pronounced changes. METHODS: Six fresh-frozen cadaver specimens were mounted in a kinematic rig. Three motion patterns were applied with the native knee and following PS TKA (passive motion, open chain extension, and squatting) while infrared cameras recorded the trajectories of markers attached to femur and tibia. Three different femoral implants were tested: a conventional posterior stabilized component, and adapted components of the same implant with 5° of intrinsic external and internal rotation, respectively. RESULTS: The implantation of the PS TKA resulted in less tibial internal rotation (squat 33-70°, p < 0.05) and the medial femoral condyle shifted posteriorly especially in deep flexion (squat 84-111°, p < 0.05). Internal component malrotation caused internal rotation and abduction of the tibia in flexion (squat 33-111°, p < 0.05), an elevated (squat 43-111°, p < 0.05) and more anterior (passive 61-126°, p < 0.05) located medial femoral condyle and a lateral femoral condyle located more posterior and inferior (squat 73-111°, p < 0.05) than in the neutrally aligned TKA. External component malrotation caused only little changes under passive motion. Under a squat there was less internal rotation and more adduction to the tibia (33-111°, p < 0.05). The medial femoral condyle was moved more posterior (squat 59-97°, p < 0.05), the lateral femoral condyle more superior (squat 54-105°, p < 0.05) than in the neutrally aligned TKA. CONCLUSION: The greatest differences to the native tibiofemoral kinematics were introduced by internal rotation of the femoral component. Also neutrally and externally rotated femoral components introduce kinematic changes, but to a lesser extent. With respect to the alterations introduced to kinematics internal malrotation should be avoided when performing PS TKA.


Assuntos
Artroplastia do Joelho/efeitos adversos , Mau Alinhamento Ósseo/fisiopatologia , Fêmur/cirurgia , Articulação do Joelho/fisiopatologia , Prótese do Joelho/efeitos adversos , Tíbia/fisiopatologia , Idoso de 80 Anos ou mais , Artroplastia do Joelho/métodos , Fenômenos Biomecânicos , Mau Alinhamento Ósseo/cirurgia , Cadáver , Fêmur/fisiopatologia , Humanos , Articulação do Joelho/cirurgia , Masculino , Amplitude de Movimento Articular , Rotação , Tíbia/cirurgia
20.
Knee ; 24(4): 751-760, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28433348

RESUMO

BACKGROUND: The recently reintroduced bicruciate retaining Total Knee Arthroplasty (BCR TKA) is an effort to reproduce kinematics closer to the native knee. However, there is no data on appropriate balancing with this implant. Balancing is crucial and challenging as medial and lateral polyethylene (PE) inlays are modular, which allows for placement of different thicknesses in the medial and lateral compartments. This study aimed at providing a detailed kinematic view on balancing BCR TKA. METHODS: Seven fresh frozen cadaver legs were mounted in a kinematic rig that applied squatting under application of physiologic quadriceps and hamstring forces. Additionally, specimen laxity was assessed using Lachman tests and varus/valgus stress tests. Following testing on the native knee, a BCR TKA was implanted in each specimen and all trials were repeated. Using one millimeter increments, five inlay thicknesses were tested to simulate optimal balancing, symmetric under-, and overstuffing, valgus constellation, and varus constellation. RESULTS: Overall, knee kinematics following BCR TKA seem to be very close to the native knee. The changes as introduced to tibiofemoral kinematics through over- or understuffing the polyethylene inserts are affecting the system only to a minor degree and generally lack statistical significance. Reproduction of the tibial varus via PE-Inlays did not lead to kinematics much closer to the native knee. CONCLUSIONS: The changes introduced to tibiofemoral kinematics by removal of the conforming meniscus and cartilage and replacement with a flat PE insert and femoral component are of more impact than different inlay sizes and their combinations for a BCR TKA.


Assuntos
Artroplastia do Joelho/métodos , Articulação do Joelho/cirurgia , Prótese do Joelho/efeitos adversos , Desenho de Prótese/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos/fisiologia , Cadáver , Feminino , Humanos , Articulação do Joelho/fisiopatologia , Masculino , Polietileno/efeitos adversos , Amplitude de Movimento Articular/fisiologia , Tíbia/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...