Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 79
Filtrar
1.
Appl Environ Microbiol ; 88(6): e0208721, 2022 03 22.
Artigo em Inglês | MEDLINE | ID: mdl-35108098

RESUMO

Hydrophobins are small secreted amphipathic proteins ubiquitous among filamentous fungi. Hydrophobin RolA produced by Aspergillus oryzae attaches to solid surfaces, recruits polyesterase CutL1, and thus promotes hydrolysis of polyesters. Because the N-terminal region of RolA is involved in the interaction with CutL1, the orientation of RolA on the solid surface is important. However, the kinetic properties of RolA adsorption to solid surfaces with various chemical properties remain unclear, and RolA structures assembled after the attachment to surfaces are unknown. Using a quartz crystal microbalance (QCM), we analyzed the kinetic properties of RolA adsorption to the surfaces of QCM electrodes that had been chemically modified to become hydrophobic or charged. We also observed the assembled RolA structures on the surfaces by atomic force microscopy and performed molecular dynamics (MD) simulations of RolA adsorption to self-assembled monolayer (SAM)-modified surfaces. The RolA-surface interaction was considerably affected by the zeta potential of RolA, which was affected by pH. The interactions of RolA with the surface seemed to be involved in the self-assembly of RolA. Three types of self-assembled structures of RolA were observed: spherical, rod-like, and mesh-like. The kinetics of RolA adsorption and the structures formed depended on the amount of RolA adsorbed, chemical properties of the electrode surface, and the pH of the buffer. Adsorption of RolA to solid surfaces seemed to depend mainly on its hydrophobic interaction with the surfaces; this was supported by MD simulations, which suggested that hydrophobic Cys-Cys loops of RolA attached to all SAM-modified surfaces at all pH values. IMPORTANCE The adsorption kinetics of hydrophobins to solid surfaces and self-assembled structures formed by hydrophobin molecules have been studied mostly independently. In this report, we combined the kinetic analysis of hydrophobin RolA adsorption onto solid surfaces and observation of RolA self-assembly on these surfaces. Since RolA, whose isoelectric point is close to pH 4.0, showed higher affinity to the solid surfaces at pH 4.0 than at pH 7.0 or 10.0, the affinity of RolA to these surfaces depends mainly on hydrophobic interactions. Our combined analyses suggest that not only the adsorbed amount of RolA but also the chemical properties of the solid surfaces and the zeta potential of RolA affect the self-assembled RolA structures formed on these surfaces.


Assuntos
Aspergillus oryzae , Adsorção , Aspergillus oryzae/metabolismo , Proteínas Fúngicas/metabolismo , Interações Hidrofóbicas e Hidrofílicas , Cinética , Propriedades de Superfície
2.
Clin Imaging ; 71: 77-82, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33181480

RESUMO

PURPOSE: To report the computed tomography (CT) findings of acute peptic ulcer disease (PUD) and to evaluate the usefulness of contrast media for diagnosis. METHODS: This retrospective study included 51 patients diagnosed with acute gastric peptic ulcer by endoscopy. Using a κ analysis, two radiologists independently reviewed contrast-enhanced emergency CTs performed within 24 h of endoscopy. Evaluation findings included low-attenuation wall thickening, focal wall thickening, focal luminal outpouching, perigastric fat stranding, ascites, adjacent lymphadenopathy, and high-density gastric contents. Of the 51 patients, 48 underwent both non-contrast-enhanced and contrast-enhanced CT, and two radiologists also evaluated the presence or absence of these findings on a non-contrast-enhanced CT. McNemar's test was used to evaluate the contrast media's usefulness. RESULTS: Interobserver variability of perigastric fat stranding revealed substantial agreement between evaluators, and other findings had almost perfect agreement. High-density gastric contents were the most recognized findings (60%). Low-attenuation focal wall thickening and focal luminal outpouching were observed in relatively large numbers (~50%) of the cases on contrast-enhanced CT. The CT examinations using contrast media provided significantly higher detectability of low-attenuation wall thickening and focal luminal outpouching than CT examinations without using contrast media. CONCLUSION: Acute PUD can be suspected in patients with nonspecific abdominal symptoms in whom emergency CT shows high-density gastric contents, focal low-attenuation wall thickening, and/or focal luminal outpouching. Our study showed that contrast media are useful for diagnosis.


Assuntos
Úlcera Péptica , Neoplasias Gástricas , Meios de Contraste , Humanos , Úlcera Péptica/diagnóstico por imagem , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
3.
Langmuir ; 36(13): 3590-3599, 2020 04 07.
Artigo em Inglês | MEDLINE | ID: mdl-32049537

RESUMO

The development of a strategy for the assembly of nanoscale building blocks, in particular, anisotropic nanoparticles, into desired structures is important for the construction of functional materials and devices. However, control over the orientation of rod-shaped nanoparticles on a substrate for integration into solid-state devices remains challenging. Here, we report a strategy for the fabrication of finely aligned gold nanorod (GNR) arrays using polymer (DNA) brushes as a nanoscale template. The gold nanorods modified with cationic surface ligands were electrostatically adsorbed onto the DNA brush substrates under various conditions. The orientational behavior of the GNRs was examined by spectral analyses and transmission electron microtomography (TEMT). As a result, we found several important factors, such as moderate interaction between GNRs and polymers and polymer densities on the substrate, related to the vertical alignment of GNRs on the substrates. We also developed a purification method to remove the undesired adsorption of GNRs onto the arrays. Finally, we have succeeded in the fabrication of extensive vertical GNR arrays of high quality via the easy bottom-up process.

4.
Gan To Kagaku Ryoho ; 47(13): 2391-2393, 2020 Dec.
Artigo em Japonês | MEDLINE | ID: mdl-33468971

RESUMO

We report the case of an elderly male patient with ductal carcinoma in situ(DCIS) of the nipple. A 93-year-old man visited the hospital because of pain and bleeding in and swelling of the right nipple. A benign tumor was suspected, but a definite diagnosis could not be made before surgery based on echo and cytology findings; thus, a malignant tumor could not be ruled out. He underwent partial mastectomy combined with the areola and nipple for diagnosis and treatment. Histologic examination confirmed the diagnosis of DCIS of the nipple. The surgical margin was negative. At 6 months after the surgery, he was doing well with no evidence of disease in the absence of postoperative adjuvant therapy. Thus, clinicians should consider breast carcinoma of the nipple as a differential diagnosis when an elderly man presents with swelling of the nipple.


Assuntos
Neoplasias da Mama , Carcinoma Intraductal não Infiltrante , Idoso , Idoso de 80 Anos ou mais , Neoplasias da Mama/cirurgia , Carcinoma Intraductal não Infiltrante/diagnóstico por imagem , Carcinoma Intraductal não Infiltrante/cirurgia , Humanos , Mastectomia , Mastectomia Segmentar , Mamilos/cirurgia
5.
J Infect Chemother ; 25(12): 995-1000, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31239192

RESUMO

BACKGROUND: Although fluoroquinolones are considered as alternative therapies of pulmonary Mycobacterium avium complex (MAC) disease, the association between fluoroquinolone resistance and MAC genotypes in clinical isolates from individuals not previously treated for MAC infection is not fully clear. METHODS: Totals of 154 M. avium isolates and 35 Mycobacterium intracellulare isolates were obtained from treatment-naïve patients with pulmonary MAC disease at the diagnosis of MAC infection at 8 hospitals in Japan. Their susceptibilities of moxifloxacin were determined by broth microdilution methods. Moxifloxacin-resistant isolates were examined for mutations of gyrA and gyrB. Variable numbers of tandem repeats (VNTR) assay was performed using 15 M. avium VNTR loci and 16 M. intracellulare VNTR loci. RESULTS: Moxifloxacin susceptibility was categorized as resistant and intermediate for 6.5% and 16.9%, respectively, of M. avium isolates and 8.6% and 17.1% of M. intracellulare isolates. Although the isolates of both species had amino acid substitutions of Thr 96 and Thr 522 at the sites corresponding to Ser 95 in the M. tuberculosis GyrA and Gly 520 in the M. tuberculosis GyrB, respectively, these substitutions were observed irrespective of susceptibility and did not confer resistance. The VNTR assays showed revealed three clusters among M. avium isolates and two clusters among M. intracellulare isolates. No significant differences in moxifloxacin resistance were observed among these clusters. CONCLUSIONS: Although resistance or intermediate resistance to moxifloxacin was observed in approximately one-fourth of M. avium and M. intracellulare isolates, this resistance was not associated with mutations in gyrA and gyrB or with VNTR genotypes.


Assuntos
Antibacterianos/farmacologia , Moxifloxacina/farmacologia , Complexo Mycobacterium avium/efeitos dos fármacos , Infecção por Mycobacterium avium-intracellulare/tratamento farmacológico , Mycobacterium avium/efeitos dos fármacos , Antibacterianos/uso terapêutico , DNA Girase/genética , Farmacorresistência Bacteriana/genética , Genótipo , Humanos , Japão , Testes de Sensibilidade Microbiana , Repetições Minissatélites/genética , Moxifloxacina/uso terapêutico , Mutação , Mycobacterium avium/genética , Mycobacterium avium/isolamento & purificação , Complexo Mycobacterium avium/genética , Complexo Mycobacterium avium/isolamento & purificação , Infecção por Mycobacterium avium-intracellulare/microbiologia
6.
Jpn J Radiol ; 37(7): 534-542, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31069621

RESUMO

PURPOSE: To clarify an early postmortem change, we investigated the volume changes of the spleen and kidney on postmortem CT compared with antemortem CT in the same patients. MATERIALS AND METHODS: We retrospectively evaluated the volumes of 56 spleens (56 cases) and 50 kidneys (25 cases) using antemortem and postmortem CT, which were performed within 168 min after death. We divided the cases of spleen analysis into a hemorrhagic group (n = 12) and a non-hemorrhagic group (n = 44). RESULTS: The volumes of the organs before and after death were 101.0 ± 70.9 (cm3, mean ± standard deviation) and 81.1 ± 57.8 in spleens, 120.3 ± 49.2 and 109.2 ± 39.2 in kidneys, respectively. Both spleens and kidneys shrank after death (p < 0.05). The volumes of spleens before and after death were 111 ± 66.5 and 67.5 ± 27.7 in the hemorrhagic group, and 98.2 ± 72.5 and 84.9 ± 63.3 in the non-hemorrhagic group, respectively. The median value of the ratio of postmortem splenic volume to antemortem volume in the hemorrhagic group (65.0%) was smaller than the one in the non-hemorrhagic group (90.5%) (p < 0.05). CONCLUSION: We demonstrated that spleens and kidneys significantly reduced in size after death. The rate of shrinkage of spleens in the hemorrhagic group significantly became larger than the one in the non-hemorrhagic group.


Assuntos
Rim/diagnóstico por imagem , Mudanças Depois da Morte , Baço/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Autopsia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
7.
Forensic Sci Int ; 296: 22-27, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30641441

RESUMO

BACKGROUND: Measurement of heart weight is important when investigating cause of death, but there is presently no satisfactory method of heart weight estimation by postmortem computed tomography (PMCT). METHOD: We investigated 33 consecutive cases that underwent both PMCT and autopsy between February 2008 and June 2014. Heart and left ventricular (LV) weights were calculated by PMCT morphometry. We used a simple method to estimate LV weight: We assumed that LV was an ellipsoid and multiplied its volume on PMCT with myocardial specific gravity. We then compared the various heart and LV weights using linear regression. The calculated and estimated LV weights on PMCT were also compared. RESULTS: It was not possible to predict heart weight at autopsy from PMCT (R2 = 0.53). However, heart weight at autopsy could be accurately predicted from LV weight calculated by PMCT (R2 = 0.77). In addition, there was a strong correlation between the estimated and calculated LV weights by PMCT (R2 = 0.92). Heart weight at autopsy could also be accurately predicted using the PMCT-estimated LV weight (R2 = 0.72). CONCLUSION: Heart weight at autopsy could be accurately predicted using a simple method in which LV volume was assumed to be an ellipsoid on PMCT.


Assuntos
Coração/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Miocárdio/patologia , Tamanho do Órgão , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Autopsia , Criança , Feminino , Patologia Legal , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/patologia , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
9.
Microscopy (Oxf) ; 67(5): 296-300, 2018 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-29893959

RESUMO

An in situ straining holder capable of tensile deformation and high-angle tilt for electron tomography was developed for polymeric materials. The holder has a dedicated sample cartridge, on which a variety of polymeric materials, such as microtomed thin sections of bulk specimens and solvent-cast thin films, can be mounted. Fine, stable control of the deformation process with nanoscale magnification was achieved. The holder allows large tensile deformation (≃800 µm) with a large field of view (800 × 200 µm before the deformation), and a high tilt angle (±75°) during in situ observations. With the large tensile deformation, the strain on the specimen can be as large as 26, at least one order of magnitude larger than the holder's predecessor. We expect that meso- and microscopic insights into the dynamic mechanical deformation and fracture processes of polymeric materials can be obtained by combining the holder with a transmission electron microscope equipped with an energy filter. The filter allows zero-loss imaging to improve the resolution and image contrast for thick specimens. We used this technique to study the deformation process in a silica nanoparticle-filled isoprene rubber.

10.
J Clin Pharmacol ; 58(10): 1361-1370, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29746707

RESUMO

This study aimed to characterize the population pharmacokinetics and exposure-response relationship of propranolol (Hemangiol® Syrup for Pediatric) in infants with infantile hemangioma. Using nonlinear mixed-effects modeling with 63 pooled sets of plasma concentration-time data from 32 Japanese patients aged 35-150 days, we described the disposition of propranolol adequately by a 1-compartment model with first-order absorption. The estimated population mean apparent clearance and apparent central volume of distribution were 9.34 L/h and 146 L, respectively. Body weight and postnatal age influenced the population pharmacokinetic model. The clinical end points-success (complete or nearly complete resolution of the target hemangioma) and failure-at weeks 12 and 24 were characterized by logistic regression using the area under the concentration-time curve (AUC), estimated from the final population pharmacokinetic model, as an exposure predictor. The logistic regression showed that a higher AUC was associated with a higher probability of successful treatment. At each exposure level, probability of successful treatment was correlated with gestational age and treatment duration. Model-predicted probabilities of successful treatment were consistent with actual results in the clinical trial. Simulations using several dosing regimens indicated that oral propranolol at 3 mg/kg per day was effective and would be appropriate for treating Japanese infants. These simulation results can support optimization of dosing regimens, such as selecting amounts, treatment durations, and dosing intervals, for clinical use.


Assuntos
Antagonistas Adrenérgicos beta/farmacocinética , Hemangioma/tratamento farmacológico , Propranolol/farmacocinética , Administração Oral , Antagonistas Adrenérgicos beta/administração & dosagem , Antagonistas Adrenérgicos beta/farmacologia , Área Sob a Curva , Simulação por Computador , Relação Dose-Resposta a Droga , Feminino , Humanos , Lactente , Masculino , Modelos Biológicos , Propranolol/administração & dosagem , Propranolol/farmacologia
11.
Sci Rep ; 8(1): 5877, 2018 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-29651011

RESUMO

Scanning electron microscopy equipped with a focused ion beam (FIB-SEM) is a promising three-dimensional (3D) imaging technique for nano- and meso-scale morphologies. In FIB-SEM, the specimen surface is stripped by an ion beam and imaged by an SEM installed orthogonally to the FIB. The lateral resolution is governed by the SEM, while the depth resolution, i.e., the FIB milling direction, is determined by the thickness of the stripped thin layer. In most cases, the lateral resolution is superior to the depth resolution; hence, asymmetric resolution is generated in the 3D image. Here, we propose a new approach based on an image-processing or deep-learning-based method for super-resolution of 3D images with such asymmetric resolution, so as to restore the depth resolution to achieve symmetric resolution. The deep-learning-based method learns from high-resolution sub-images obtained via SEM and recovers low-resolution sub-images parallel to the FIB milling direction. The 3D morphologies of polymeric nano-composites are used as test images, which are subjected to the deep-learning-based method as well as conventional methods. We find that the former yields superior restoration, particularly as the asymmetric resolution is increased. Our super-resolution approach for images having asymmetric resolution enables observation time reduction.

12.
Jpn J Radiol ; 36(4): 312, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29383620

RESUMO

In the original publication of the article, the seventh author name was incorrectly published as Hidehumi Aoyama. The correct author name should read as Hidefumi Aoyama.

13.
Gan To Kagaku Ryoho ; 45(1): 184-186, 2018 Jan.
Artigo em Japonês | MEDLINE | ID: mdl-29362349

RESUMO

We report the case of a patient with triple negative breast cancer(TNBC)who showed isolated brain metastasis relatively soon after pathological complete response(pCR)to neoadjuvant chemotherapy. A 45-year-old woman with a diagnosis of TNBC(T2N1M0, Stage II B)received neoadjuvant chemotherapy with 5-FU/epirubicin/cyclophosphamide(FEC), followed by docetaxel. After the neoadjuvant chemotherapy, she underwent mastectomy and axillary lymph node dissection. Histological examination of the resected specimens revealed pCR. Brain metastasis, however, developed 7 months after the resection. She underwent total removal of the brain tumor and 50 Gy irradiation to the right frontal lobe. Histological examination confirmed a diagnosis of metastasis from TNBC. She is doing well with no evidence of disease 81 months after resection of the brain metastasis. This case and a review of the literature suggest that the clinician should be aware that brain metastasis from breast cancer may develop even after achieving pCR to neoadjuvant chemotherapy. Surgical resection followed by radiotherapy may provide a survival benefit for selected patients with isolated brain metastasis from breast cancer.


Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Neoplasias Encefálicas/secundário , Terapia Neoadjuvante , Neoplasias de Mama Triplo Negativas/tratamento farmacológico , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/cirurgia , Feminino , Humanos , Pessoa de Meia-Idade , Resultado do Tratamento , Neoplasias de Mama Triplo Negativas/patologia , Neoplasias de Mama Triplo Negativas/cirurgia
14.
Gan To Kagaku Ryoho ; 45(13): 2354-2356, 2018 Dec.
Artigo em Japonês | MEDLINE | ID: mdl-30692462

RESUMO

We report the case ofan elderly patient with squamous cell carcinoma(SCC)ofthe breast, which showed negative conversion after endocrine therapy. An 82-year-old woman with a diagnosis ofER -positive SCC(cT1N0M0, StageⅠ)received primary endocrine therapy with 5 hormonal medicines. Following the endocrine therapy, she underwent mastectomy and axillary node resection. Histological examination confirmed a diagnosis of ER-negative SCC. At 10 months after the operation, she was doing well with no evidence ofdisease without postoperative adjuvant therapy. Thus, clinicians should be aware that the ER status may change after primary endocrine therapy. For elderly patients with breast cancer, it is important to be aware that primary endocrine therapy can become ineffective due to ER-negative conversion and aging due to prolonged treatment.


Assuntos
Neoplasias da Mama , Carcinoma de Células Escamosas , Idoso de 80 Anos ou mais , Neoplasias da Mama/tratamento farmacológico , Neoplasias da Mama/cirurgia , Carcinoma de Células Escamosas/tratamento farmacológico , Carcinoma de Células Escamosas/cirurgia , Terapia Combinada , Feminino , Humanos , Excisão de Linfonodo , Mastectomia , Receptores de Estrogênio/análise
15.
Soft Matter ; 13(32): 5428-5436, 2017 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-28702567

RESUMO

Block copolymer micelles have been extensively discussed for many decades because of their applications, such as lithography and drug delivery. However, controlling the morphologies of nanostructure assembly using block copolymer micelles as building elements remains a great challenge. In this work, we developed a novel route to induce micelle assembly in confined geometries. Polystyrene-block-polydimethylsiloxane (PS-b-PDMS) micelle solutions were used to prepare micelle nanostructures, and the critical parameters affecting the morphologies were determined. Micelle nanorods, micelle nanospheres, and multi-component nanopeapods were prepared by wetting anodic aluminum oxide (AAO) templates with micelle solutions. Rayleigh-instability-driven transformation was discovered to play an important role in controlling the morphologies of the micelle nanostructures. This study not only proposes a versatile approach to preparing block copolymer micelle nanostructures, but it also provides deeper insight into the controlling factors of block copolymer micelle morphologies in cylindrical confinement.

16.
Nat Commun ; 8(1): 109, 2017 07 24.
Artigo em Inglês | MEDLINE | ID: mdl-28740078

RESUMO

Despite recent advances in the carbonization of organic crystalline solids like metal-organic frameworks or supramolecular frameworks, it has been challenging to convert crystalline organic solids into ordered carbonaceous frameworks. Herein, we report a route to attaining such ordered frameworks via the carbonization of an organic crystal of a Ni-containing cyclic porphyrin dimer (Ni2-CPDPy). This dimer comprises two Ni-porphyrins linked by two butadiyne (diacetylene) moieties through phenyl groups. The Ni2-CPDPy crystal is thermally converted into a crystalline covalent-organic framework at 581 K and is further converted into ordered carbonaceous frameworks equipped with electrical conductivity by subsequent carbonization at 873-1073 K. In addition, the porphyrin's Ni-N4 unit is also well retained and embedded in the final framework. The resulting ordered carbonaceous frameworks exhibit an intermediate structure, between organic-based frameworks and carbon materials, with advantageous electrocatalysis. This principle enables the chemical molecular-level structural design of three-dimensional carbonaceous frameworks.Carbon-based materials are promising alternatives to noble metal catalysts, but their structures are typically disordered and difficult to control. Here, the authors obtain ordered carbonaceous frameworks with advantageous electrocatalytic properties via the carbonization of nickel-containing porphyrin dimer networks.

17.
Acc Chem Res ; 50(6): 1293-1302, 2017 06 20.
Artigo em Inglês | MEDLINE | ID: mdl-28525260

RESUMO

Self-assembling structures and their dynamical processes in polymeric systems have been investigated using three-dimensional transmission electron microscopy (3D-TEM). Block copolymers (BCPs) self-assemble into nanoscale periodic structures called microphase-separated structures, a deep understanding of which is important for creating nanomaterials with superior physical properties, such as high-performance membranes with well-defined pore size and high-density data storage media. Because microphase-separated structures have become increasingly complicated with advances in precision polymerization, characterizing these complex morphologies is becoming increasingly difficult. Thus, microscopes capable of obtaining 3D images are required. In this article, we demonstrate that 3D-TEM is an essential tool for studying BCP nanostructures, especially those self-assembled during dynamical processes and under confined conditions. The first example is a dynamical process called order-order transitions (OOTs). Upon changing temperature or pressure or applying an external field, such as a shear flow or electric field, BCP nanostructures transform from one type of structure to another. The OOTs are examined by freezing the specimens in the middle of the OOT and then observing the boundary structures between the preexisting and newly formed nanostructures in three-dimensions. In an OOT between the bicontinuous double gyroid and hexagonally packed cylindrical structures, two different types of epitaxial phase transition paths are found. Interestingly, the paths depend on the direction of the OOT. The second example is BCP self-assemblies under confinement that have been examined by 3D-TEM. A variety of intriguing and very complicated 3D morphologies can be formed even from the BCPs that self-assemble into simple nanostructures, such as lamellar and cylindrical structures in the bulk (in free space). Although 3D-TEM is becoming more frequently used for detailed morphological investigations, it is generally used to study static nanostructures. Although OOTs are dynamical processes, the actual experiment is done in the static state, through a detailed morphological study of a snapshot taken during the OOT. Developing time-dependent nanoscale 3D imaging has become a hot topic. Here, the two main problems preventing the development of in situ electron tomography for polymer materials are addressed. First, the staining protocol often used to enhance contrast for electrons is replaced by a new contrast enhancement based on chemical differences between polymers. In this case, no staining is necessary. Second, a new 3D reconstruction algorithm allows us to obtain a high-contrast, quantitative 3D image from fewer projections than is required for the conventional algorithm to achieve similar contrast, reducing the number of projections and thus the electron beam dose. Combining these two new developments is expected to open new doors to 3D in situ real-time structural observation of polymer materials.

18.
Pediatr Int ; 59(8): 869-877, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28453894

RESUMO

BACKGROUND: There have been few reports on the efficacy and safety of oral propranolol at 3 mg/kg/day for infantile hemangioma (IH) in Japanese patients. METHODS: A multicenter, open-label phase III study was conducted to evaluate the efficacy and safety of oral propranolol solution in Japanese infants aged 35-150 days with proliferating IH. Thirty-two patients were enrolled in the study, received propranolol solution for 24 weeks at 3 mg/kg/day, and completed the study. RESULTS: The success rate (complete or nearly complete resolution) at week 24 (primary endpoint) was 78% (95%CI: 60-91%). The improvement rate since the previous visit was 100% (32/32) after week 5. Overall, the IH surface area, maximum diameter, and color intensity all decreased over time. Consistency in assessment between the centralized and the investigator on-site assessments was observed in 26 patients. Of the 32 patients, 11 needed further treatment other than the study drug. The incidence of adverse events (AE) and drug-related AE was 97% and 31%, respectively. AE that occurred in ≥two patients were either typical of propranolol use (such as blood pressure decrease) or common events in infants. AE that resulted in dose reduction were observed in two patients, but no serious AE or AE that led to study drug discontinuation were observed. CONCLUSION: Oral propranolol solution at 3 mg/kg/day is effective and safe in Japanese IH patients.


Assuntos
Antagonistas Adrenérgicos beta/uso terapêutico , Hemangioma Capilar/tratamento farmacológico , Propranolol/uso terapêutico , Administração Oral , Esquema de Medicação , Feminino , Seguimentos , Humanos , Lactente , Japão , Masculino , Resultado do Tratamento
19.
Soft Matter ; 12(40): 8448, 2016 10 12.
Artigo em Inglês | MEDLINE | ID: mdl-27714344

RESUMO

Correction for 'Frustrated phases under three-dimensional confinement simulated by a set of coupled Cahn-Hilliard equations' by Edgar Avalos et al., Soft Matter, 2016, 12, 5905-5914.

20.
Jpn J Antibiot ; 69(2): 101-10, 2016 Apr.
Artigo em Japonês | MEDLINE | ID: mdl-27544978

RESUMO

A study was conducted of the 1,225 Pseudomonas aeruginosa strains that were isolated at 20 medical institutions in the Kinki district between 2011 and 2013 to determine their antimicrobial susceptibility and to characterize the strains of multidrug-resistant Pseudomonas aeruginosa (MDRP) and the metallo-ß-lactamase (MBL) -producing strains. The MIC50/MIC90 values (µg/mL) of the various antimicrobial agents were as follows: imipenem, 2/>8; meropenem, 1/>8; doripenem, 0.5/8; biapenem, 1/>8; tazobactam/piperacillin, 8/>64; piperacillin, 8/>64; sulbactam/cefoperazone, 8/64; cefepime, 4/16; cefozopran, 2/>16; aztreonam, 8/>16; amikacin, 4/16; levofloxacin, 1/>4; and ciprofloxacin, 0.25/>2. From the viewpoint of the annual changes in the susceptibility rates (according to the CLSI guidelines [M100-S22]), the susceptibility to tazobactam/piperacillin, piperacillin, cefepime, cefozopran and aztreonam decreased in 2013. On the other hand, two antimicrobial agents showed high susceptibility rates each year; amikacin (94.0-95.6%) showed the highest rate, followed by doripenem (80.3-82.6%). With the exception of amikacin, there were substantial inter-institutional differences in antimicrobial susceptibility. In comparison to the previous CLSI guidelines (M100-S21), the new CLSI guidelines (M100-S22) on the use of carbapenems and penicillins show that the MIC80 has been affected. The MDRP detection rates in 2011, 2012 and 2013 were 1.8% (8 strains), 1.8% (8 strains), and 2.8% (10 strains), respectively. The MBL detection rates were as follows: bla(VIM-2), 0.2% (1 strain) in 2011; bla(IMP-1), 0.9% (4 strains) in 2012, and 1.7% (6 strains, including bla(IMP-1) [3 strains], bla(IMP-2) [2 strains] and bla(VIM-2) [1 strain]) in 2013.


Assuntos
Antibacterianos/farmacologia , Pseudomonas aeruginosa/isolamento & purificação , Farmacorresistência Bacteriana Múltipla , Humanos , Japão , Testes de Sensibilidade Microbiana , Pseudomonas aeruginosa/efeitos dos fármacos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA