Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Nat Commun ; 14(1): 7046, 2023 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-37949859

RESUMO

Large laser facilities have recently enabled material characterization at the pressures of Earth and Super-Earth cores. However, the temperature of the compressed materials has been largely unknown, or solely relied on models and simulations, due to lack of diagnostics under these challenging conditions. Here, we report on temperature, density, pressure, and local structure of copper determined from extended x-ray absorption fine structure and velocimetry up to 1 Terapascal. These results nearly double the highest pressure at which extended x-ray absorption fine structure has been reported in any material. In this work, the copper temperature is unexpectedly found to be much higher than predicted when adjacent to diamond layer(s), demonstrating the important influence of the sample environment on the thermal state of materials; this effect may introduce additional temperature uncertainties in some previous experiments using diamond and provides new guidance for future experimental design.

2.
Phys Rev Lett ; 129(23): 235001, 2022 Dec 02.
Artigo em Inglês | MEDLINE | ID: mdl-36563203

RESUMO

Solids ablate under laser irradiation, but experiments have not previously characterized the initiation of this process at ultrarelativistic laser intensities. We present first measurements of bulk ion velocity distributions as ablation begins, captured as a function of depth via Doppler-shifted x-ray line emission from two viewing angles. Bayesian analysis indicates that bulk ions are either nearly stationary or flowing outward at the plasma sound speed. The measurements quantitatively constrain the laser-plasma ablation mechanism, suggesting that a steplike electrostatic potential structure drives solid disassembly.

3.
Rev Sci Instrum ; 93(10): 103548, 2022 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-36319320

RESUMO

A new class of crystal shapes has been developed for x-ray spectroscopy of point-like or small (a few mm) emission sources. These optics allow for dramatic improvement in both achievable energy resolution and total throughput of the spectrometer as compared with traditional designs. This class of crystal shapes, collectively referred to as the Variable-Radii Spiral (VR-Spiral), utilize crystal shapes in which both the major and minor radii are variable. A crystal using this novel VR-Spiral shape has now been fabricated for high-resolution Extended X-ray Absorption Fine Structure (EXAFS) experiments targeting the Pb-L3 (13.0 keV) absorption edge at the National Ignition Facility. The performance of this crystal has been characterized in the laboratory using a microfocus x-ray source, showing that high-resolution high-throughput EXAFS spectra can be acquired using this geometry. Importantly, these successful tests show that the complex three-dimensional crystal shape is manufacturable with the required precision needed to realize the expected performance of better than 5 eV energy resolution while using a 30 mm high crystal. An improved generalized mathematical form for VR-Spiral shapes is also presented allowing improved optimization as compared to the first sinusoidal-spiral based design. This new formulation allows VR-Spiral spectrometers to be designed at any magnification with optimized energy resolution at all energies within the spectrometer bandwidth.

4.
Rev Sci Instrum ; 93(10): 103527, 2022 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-36319349

RESUMO

A high-resolution x-ray spectrometer was coupled with an ultrafast x-ray streak camera to produce time-resolved line shape spectra measured from hot, solid-density plasmas. A Bragg crystal was placed near laser-produced plasma to maximize throughput; alignment tolerances were established by ray tracing. The streak camera produced single-shot, time-resolved spectra, heavily sloped due to photon time-of-flight differences, with sufficient reproducibility to accumulate photon statistics. The images are time-calibrated by the slope of streaked spectra and dewarped to generate spectra emitted at different times defined at the source. The streaked spectra demonstrate the evolution of spectral shoulders and other features on ps timescales, showing the feasibility of plasma parameter measurements on the rapid timescales necessary to study high-energy-density plasmas.

5.
Rev Sci Instrum ; 93(10): 103508, 2022 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-36319367

RESUMO

WEST (tungsten environment in steady-state tokamak) is starting operation for the first time with a water-cooled full tungsten divertor, enabling long pulse operation. Heating is provided by radiofrequency systems, including lower hybrid current drive (LHCD). In this context, a compact multi-energy hard x-ray camera has been installed for energy and space-resolved measurements of the electron temperature, the fast electron tail density produced by LHCD and runaway electrons, and the beam-target emission of tungsten at the target due to fast electron losses interacting with the divertor plates. The diagnostic is a pinhole camera based on a 2D pixel array detector (Pilatus 3 CdTe CMOS Hybrid-Pixel detector produced by DECTRIS). The novelty of this diagnostic technique is the detector's capability of adjusting the threshold energy at pixel level. This innovation provides great flexibility in the energy configuration, allowing simultaneous space and energy-resolved x-ray measurements. This contribution details two important steps in the preparation of the diagnostic operation. First, the in-vessel spatial calibration that was carried out with a radioactive source. Second, the synthetic diagnostic is obtained by the suite of codes ALOHA/C3PO/LUKE/R5-X2, which simulates LH wave propagation and absorption, as well as the fast electron bremsstrahlung production.

6.
Phys Rev Lett ; 128(18): 185002, 2022 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-35594117

RESUMO

Evolution of the hot spot plasma conditions was measured using high-resolution x-ray spectroscopy at the National Ignition Facility. The capsules were filled with DD gas with trace levels of Kr and had either a high-density-carbon (HDC) ablator or a tungsten (W)-doped HDC ablator. Time-resolved measurement of the Kr Heß spectra, absolutely calibrated by a simultaneous time-integrated measurement, allows inference of the electron density and temperature through observing Stark broadening and the relative intensities of dielectronic satellites. By matching the calculated hot spot emission using a collisional-radiative code to experimental observations, the hot spot size and areal density are determined. These advanced spectroscopy techniques further reveal the effect of W dopant in the ablator on the hot spot parameters for their improved implosion performance.

7.
Phys Rev Lett ; 127(20): 205001, 2021 Nov 12.
Artigo em Inglês | MEDLINE | ID: mdl-34860067

RESUMO

Heß spectral line shapes are important for diagnosing temperature and density in many dense plasmas. This work presents Heß line shapes measured with high spectral resolution from solid-density plasmas with minimized gradients. The line shapes show hallmark features of Stark broadening, including quantifiable redshifts and double-peaked structure with a significant dip between the peaks; these features are compared to models through a Markov chain Monte Carlo framework. Line shape theory using the dipole approximation can fit the width and peak separation of measured line shapes, but it cannot resolve an ambiguity between electron density n_{e} and ion temperature T_{i}, since both parameters influence the strength of quasistatic ion microfields. Here a line shape model employing a full Coulomb interaction for the electron broadening computes self-consistent line widths and redshifts through the monopole term; redshifts have different dependence on plasma parameters and thus resolve the n_{e}-T_{i} ambiguity. The measured line shapes indicate densities that are 80-100% of solid, identifying a regime of highly ionized but well-tamped plasma. This analysis also provides the first strong evidence that dense ions and electrons are not in thermal equilibrium, despite equilibration times much shorter than the duration of x-ray emission; cooler ions may arise from nonclassical thermalization rates or anomalous energy transport. The experimental platform and diagnostic technique constitute a promising new approach for studying ion-electron equilibration in dense plasmas.

8.
Rev Sci Instrum ; 92(9): 093904, 2021 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-34598494

RESUMO

A novel high-resolution x-ray spectrometer for point-like emission sources has been developed using a crystal shape having both a variable major and a variable minor radius of curvature. This variable-radii sinusoidal spiral spectrometer (VR-Spiral) allows three common spectrometer design goals to be achieved simultaneously: 1. reduction of aberrations and improved spectral (energy) resolution, 2. reduction of source size broadening, and 3. use of large crystals to improve total throughput. The VR-Spiral concept and its application to practical spectrometer design are described in detail. This concept is then used to design a spectrometer for an extreme extended x-ray absorption fine structure experiment at the National Ignition Facility looking at the Pb L3 absorption edge at 13.0352 keV. The expected performance of this VR-Spiral spectrometer, both in terms of energy resolution and spatial resolution, is evaluated through the use of a newly developed raytracing tool, xicsrt. Finally, the expected performance of the VR-Spiral concept is compared to that of spectrometers based on conventional toroidal and variable-radii toroidal crystal geometries showing a greatly improved energy resolution.

9.
Rev Sci Instrum ; 92(4): 043509, 2021 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-34243460

RESUMO

A compact multi-energy soft x-ray diagnostic is being installed on the W Environment in Steady-state Tokamak (WEST), which was designed and built to test ITER-like tungsten plasma facing components in a long pulse (∼1000 s) scenario. The diagnostic consists of a pinhole camera fielded with the PILATUS3 photon-counting Si-based detector (≲100 kpixel). The detector has sensitivity in the range 1.6-30 keV and enables energy discrimination, providing a higher energy resolution than conventional systems with metal foils and diodes with adequate space and time resolution (≲1 cm and 2 ms). The lower-absorption cut-off energy is set independently on each one of the ∼100 kpixels, providing a unique opportunity to measure simultaneously the plasma emissivity in multiple energy ranges and deduce a variety of plasma parameters (e.g., Te, nZ, and ΔZeff). The energy dependence of each pixel is calibrated here over the range 3-22 keV. The detector is exposed to a variety of monochromatic sources-fluorescence emission from metallic targets-and for each pixel, the lower energy threshold is scanned to calibrate the energy dependence. The data are fit to a responsivity curve ("S-curve") that determines the mapping between the possible detector settings and the energy response for each pixel. Here, the calibration is performed for three energy ranges: low (2.3-6 keV), medium (4.5-13.5 keV), and high (5.4-21 keV). We determine the achievable energy resolutions for the low, medium, and high energy ranges as 330 eV, 640 eV, and 950 eV, respectively. The main limitation for the energy resolution is found to be the finite width of the S-curve.

10.
Rev Sci Instrum ; 92(5): 053102, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-34243250

RESUMO

We report the development of a high-resolution spectrometer for extended x-ray absorption fine structure (EXAFS) studies of materials under extreme conditions. A curved crystal and detector in the spectrometer are replaceable such that a single body is employed to perform EXAFS measurements at different x-ray energy intervals of interest. Two configurations have been implemented using toroidal crystals with Ge 311 reflection set to provide EXAFS at the Cu K-edge (energy range 8.9-9.8 keV) and Ge 400 reflection set to provide EXAFS at the Ta L3-edge (9.8-10.7 keV). Key performance characteristics of the spectrometer were found to be consistent with design parameters. The data generated at the National Ignition Facility have shown an ≃3 eV spectral resolution for the Cu K-edge configuration and ≃6 eV for the Ta L3-edge configuration.

11.
Rev Sci Instrum ; 92(4): 043531, 2021 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-34243385

RESUMO

This paper describes a new class of focusing crystal forms for the x-ray Bragg crystal spectroscopy of small, point-like, x-ray sources. These new crystal forms are designed with the aid of sinusoidal spirals, a family of curves, whose shapes are defined by only one parameter, which can assume any real value. The potential of the sinusoidal spirals for the design x-ray crystal spectrometers is demonstrated with the design of a toroidally bent crystal of varying major and minor radii for measurements of the extended x-ray absorption fine structure near the Ta-L3 absorption edge at the National Ignition Facility.

12.
Rev Sci Instrum ; 92(4): 043530, 2021 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-34243399

RESUMO

X-ray ray tracing is used to develop ion-temperature corrections for the analysis of the X-ray Imaging Crystal Spectrometer (XICS) used at Wendelstein 7-X (W7-X) and perform verification on the analysis methods. The XICS is a powerful diagnostic able to measure ion-temperature, electron-temperature, plasma flow, and impurity charge state densities. While these systems are relatively simple in design, accurate characterization of the instrumental response and validation of analysis techniques are difficult to perform experimentally due to the requirement of extended x-ray sources. For this reason, a ray tracing model has been developed that allows characterization of the spectrometer and verification of the analysis methods while fully considering the real geometry of the XICS system and W7-X plasma. Through the use of ray tracing, several important corrections have been found that must be accounted for in order to accurately reconstruct the ion-temperature profiles. The sources of these corrections are described along with their effect on the analyzed profiles. The implemented corrections stem from three effects: (1) effect of sub-pixel intensity distribution during de-curving and spatial binning, (2) effect of sub-pixel intensity distribution during forward model evaluation and generation of residuals, and (3) effect of defocus and spherical aberrations on the instrumental response. Possible improvements to the forward model and analysis procedures are explored, along with a discussion of trade-offs in terms of computational complexity. Finally, the accuracy of the tomographic inversion technique in stellarator geometry is investigated, providing for the first time a verification exercise for inversion accuracy in stellarator geometry and a complete XICS analysis tool-chain.

13.
Rev Sci Instrum ; 92(3): 033525, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33820090

RESUMO

Fine-structure x-ray spectra have been measured from foils with embedded tracer layers at two laser facilities. A suite of layered foils with thin Ti tracers under varied tamper layers was studied at both the Titan and the ALEPH 400 nm laser facilities, where Ti Heα emission was recorded using a high-resolution Bragg crystal spectrometer. Several indicators of plasma parameters are examined in the spectra, including temperature- and density-dependent line ratios and line broadening from Stark and opacity effects. Spectra indicate that (1) the plasma density at ALEPH is significantly higher than at Titan and (2) the electron temperature is high for near-surface layers at both facilities but drops more quickly with depth at ALEPH. These inferences of plasma conditions are consistent with differing levels of temporal contrast at each laser facility.

14.
Rev Sci Instrum ; 89(10): 10F118, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399766

RESUMO

The here-described spectrometer was developed for the extended x-ray absorption fine structure spectroscopy of high-density plasmas at the National Ignition Facility. It employs as the Bragg reflecting element a new type of toroidally bent crystal with a constant and very large major radius R and a much smaller, locally varying, minor radius r. The focusing properties of this crystal and the experimental arrangement of the source and detector make it possible to (a) fulfill the conditions for a perfect imaging of an ideal point source for each wavelength, (b) obtain a high photon throughput, (c) obtain a high spectral resolution by eliminating the effects of source-size broadening, and (d) obtain a one-dimensional spatial resolution with a high magnification perpendicular to the main dispersion plane.

15.
Rev Sci Instrum ; 89(10): 10F125, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399848

RESUMO

A high resolution, Diagnostic Instrument Manipulator (DIM)-based x-ray Bragg crystal spectrometer has been calibrated for and deployed at the National Ignition Facility (NIF) to diagnose plasma conditions in ignition capsules near stagnation times. The spectrometer has two conical crystals in the Hall geometry focusing rays from the Kr Heα, Lyα, and Heß complexes onto a streak camera, with the physics objectives of measuring time-resolved electron density and temperature through observing Stark broadening and the relative intensities of dielectronic satellites. A third von Hámos crystal that time-integrates the Kr Heα, Heß and intervening energy range provides in situ calibration for the streak camera signals. The spectrometer has been absolutely calibrated using a microfocus x-ray source, an array of CCD and single-photon-counting detectors, and multiple K- and L-absorption edge filters at the Princeton Plasma Physics Laboratory (PPPL) x-ray laboratory. Measurements of the integrated reflectivity, energy range, and energy resolution for each crystal are discussed. These calibration data provide absolute x-ray signal levels for NIF measurements, enabling precise filter selection and comparisons to simulations.

16.
Rev Sci Instrum ; 89(10): 10F112, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399885

RESUMO

Newly developed large-area pixelated two-dimensional detector and two-crystal assemblies were deployed for the first time on tokamaks to enable time-resolved Bragg-diffracted x-ray imaging with good framing rate and water-cooling capabilities for in-vacuum long-pulse operations. High-quality helium-like (He-like) and hydrogen-like (H-like) argon spectra have been observed simultaneously for the first time on a single detector for a wide range of plasma parameters to infer both ion temperature and rotation profiles and support studies on spontaneous rotation, impurity transport, and RF physics. Since tokamak plasmas rotate in both the poloidal (θ) and toroidal (ϕ) directions, a reliable wavelength calibration is needed to account for the correct Doppler shift as well as to compute the spectrometer's instrumental function. Lyα lines emitted from Cd x-ray tubes are proposed to be used as "markers" to provide an in situ calibration of the EAST's X-ray imaging crystal spectrometer systems measuring He- and H-like argon spectra. The first lab test indicated that the X-ray tube can excite strong Lyα lines at 15 kV voltage and 1 mA current when the crystal is shined for 10 min. Other indirect calibration methods using locked-mode discharge scenarios were also studied as complementary methods.

17.
Rev Sci Instrum ; 89(10): 10F110, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399886

RESUMO

A two-crystal X-ray spectrometer system has been implemented in the EAST tokamak to simultaneously diagnose high- and low-temperature plasmas using He- and H-like argon spectra. But for future fusion devices like ITER and Chinese Fusion Engineering Test Reactor (CFETR), argon ions become fully stripped in the core and the intensity of the H-like lines will be significantly at high temperatures (Te > 5 keV). With increasing auxiliary heating power on EAST, the core plasma temperature could also reach 5 keV and higher. In such conditions, the use of a xenon puff becomes an appropriate choice for both ion-temperature and flow-velocity measurements. A new two-crystal system using a quartz 110 crystal (2d = 4.913 Å) to view He-like argon lines and a quartz 011 crystal (2d = 6.686 Å) to view Ne-like xenon spectra has been deployed on a poloidal X-ray crystal spectrometer. While the He-like argon spectra will be used to measure the plasma temperature in the edge plasma region, the Ne-like xenon spectra will be used for measurement in the hot core. The new crystal arrangement allows a wide temperature measurement ranging from 0.5 to 10 keV or even higher, being the first tests for burning plasmas like ITER and CFETR. The preliminary result of lab-tests, Ne-like xenon lines measurement will be presented.

18.
Rev Sci Instrum ; 88(12): 123116, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29289176

RESUMO

A new x-ray imaging crystal spectrometer is developed for time-resolved measurements of x-ray line spectra. One of the main advantages is that it produces perfect images of a point source for each wavelength in a selectable spectral range. The other advantage is that the detector plane can have an arbitrary orientation with respect to the crystal surface. These unique imaging properties are obtained by bending the crystal into a certain shape, which is generated by arranging multiple cones from different aperture angles on a common nodal line. The test results were presented from optical tests of the multi-cone and single-cone structures. The numerical results on the deteriorations of the spectral and spatial resolutions are obtained due to the potential misalignments of the source. The concept of the configuration is considered to be particularly useful for high-power laser experiments where the size of the source is small and a wide spectral range would be diagnosed.

19.
Rev Sci Instrum ; 87(11): 11E344, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910374

RESUMO

A high resolution (E/ΔE = 1200-1800) Bragg crystal x-ray spectrometer is being developed to measure plasma parameters in National Ignition Facility experiments. The instrument will be a diagnostic instrument manipulator positioned cassette designed mainly to infer electron density in compressed capsules from Stark broadening of the helium-ß (1s2-1s3p) lines of krypton and electron temperature from the relative intensities of dielectronic satellites. Two conically shaped crystals will diffract and focus (1) the Kr Heß complex and (2) the Heα (1s2-1s2p) and Lyα (1s-2p) complexes onto a streak camera photocathode for time resolved measurement, and a third cylindrical or conical crystal will focus the full Heα to Heß spectral range onto an image plate to provide a time integrated calibration spectrum. Calculations of source x-ray intensity, spectrometer throughput, and spectral resolution are presented. Details of the conical-crystal focusing properties as well as the status of the instrumental design are also presented.

20.
Rev Sci Instrum ; 87(11): 11E333, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910415

RESUMO

This article describes a new x-ray imaging Bragg crystal spectrometer, which-in combination with a streak camera or a gated strip detector-can be used for time-resolved measurements of x-ray line spectra at the National Ignition Facility and other high power laser facilities. The main advantage of this instrument is that it produces perfect images of a point source for each wavelength in a selectable spectral range and that the detector plane can be perpendicular to the crystal surface or inclined by an arbitrary angle with respect to the crystal surface. These unique imaging properties are obtained by bending the x-ray diffracting crystal into a certain shape, which is generated by arranging multiple cones with different aperture angles on a common nodal line.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...