Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Phys Chem Chem Phys ; 26(19): 14317-14328, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38695736

RESUMO

The parahydrogen-induced polarisation (PHIP) NMR signal enhancement technique is used to study H2 addition to Vaska's complex (trans-[IrCl(CO)(PPh3)2]) with both standard high-field (9.4 T) NMR and benchtop (1 T) NMR detection. Accurate and repeatable rate constants of (0.84 ± 0.03) dm3 mol-1 s-1 and (0.89 ± 0.03) dm3 mol-1 s-1 were obtained for this model system using standard high-field and benchtop NMR, respectively. The high-field NMR approach is shown to be susceptible to systematic errors associated with interference from non-hyperpolarised signals, which can be overcome through a multiple-quantum filtered acquisition scheme. This challenge is avoided when using benchtop NMR detection because the non-hyperpolarised signals are much weaker due to the lower magnetic field, enabling the use of a simpler and more efficient single RF pulse detection scheme. Method validation against several experimental parameters (NMR relaxation, %pH2 enrichment and temperature) demonstrates the robustness of the benchtop NMR approach but also highlights the need for sample temperature control throughout reaction monitoring. A simple temperature equilibration protocol, coupled with use of an insulated sample holder while manipulating the sample outside the spectrometer, is found to provide sufficient temperature stabilisation to ensure that accurate and repeatable rate constants are obtained. Finally, the benchtop NMR reaction monitoring protocol is applied to the analysis of a complex mixture, where multiple reaction products form simultaneously. H2 addition to a mixture of three Vaska's complex derivatives was monitored, revealing the presence of competitive reaction pathways within the mixture.

2.
Molecules ; 24(22)2019 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-31739621

RESUMO

Hyperpolarization methods, which increase the sensitivity of nuclear magnetic resonance (NMR) and magnetic resonance imaging (MRI), have the potential to expand the range of applications of these powerful analytical techniques and to enable the use of smaller and cheaper devices. The signal amplification by reversible exchange (SABRE) method is of particular interest because it is relatively low-cost, straight-forward to implement, produces high-levels of renewable signal enhancement, and can be interfaced with low-cost and portable NMR detectors. In this work, we demonstrate an in situ approach to SABRE hyperpolarization that can be achieved using a simple, commercially-available Earth's field NMR detector to provide 1H polarization levels of up to 3.3%. This corresponds to a signal enhancement over the Earth's magnetic field by a factor of ε > 2 × 108. The key benefit of our approach is that it can be used to directly probe the polarization transfer process at the heart of the SABRE technique. In particular, we demonstrate the use of in situ hyperpolarization to observe the activation of the SABRE catalyst, the build-up of signal in the polarization transfer field (PTF), the dependence of the hyperpolarization level on the strength of the PTF, and the rate of decay of the hyperpolarization in the ultra-low-field regime.


Assuntos
Campos Magnéticos , Espectroscopia de Ressonância Magnética/métodos , Catálise
3.
Proc Natl Acad Sci U S A ; 113(12): 3164-8, 2016 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-26961001

RESUMO

Hyperpolarized (hp) (83)Kr is a promising MRI contrast agent for the diagnosis of pulmonary diseases affecting the surface of the respiratory zone. However, the distinct physical properties of (83)Kr that enable unique MRI contrast also complicate the production of hp (83)Kr. This work presents a previously unexplored approach in the generation of hp (83)Kr that can likewise be used for the production of hp (129)Xe. Molecular nitrogen, typically used as buffer gas in spin-exchange optical pumping (SEOP), was replaced by molecular hydrogen without penalty for the achievable hyperpolarization. In this particular study, the highest obtained nuclear spin polarizations were P =29% for(83)Kr and P= 63% for (129)Xe. The results were reproduced over many SEOP cycles despite the laser-induced on-resonance formation of rubidium hydride (RbH). Following SEOP, the H2 was reactively removed via catalytic combustion without measurable losses in hyperpolarized spin state of either (83)Kr or (129)Xe. Highly spin-polarized (83)Kr can now be purified for the first time, to our knowledge, to provide high signal intensity for the advancement of in vivo hp (83)Kr MRI. More generally, a chemical reaction appears as a viable alternative to the cryogenic separation process, the primary purification method of hp(129)Xe for the past 2 1/2 decades. The inherent simplicity of the combustion process will facilitate hp (129)Xe production and should allow for on-demand continuous flow of purified and highly spin-polarized (129)Xe.


Assuntos
Meios de Contraste , Hidrogênio/química , Criptônio/química , Xenônio/química , Catálise , Imageamento por Ressonância Magnética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA