Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Diabetes Care ; 47(1): 101-108, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37874987

RESUMO

OBJECTIVE: Cystic fibrosis-related diabetes (CFRD) affects up to 50% of adults with cystic fibrosis and adds significant morbidity and treatment burden. We evaluated the safety and efficacy of automated insulin delivery with the iLet bionic pancreas (BP) in adults with CFRD in a single-center, open-label, random-order, crossover trial. RESEARCH DESIGN AND METHODS: Twenty participants with CFRD were assigned in random order to 14 days each on the BP or their usual care (UC). No restrictions were placed on diet or activity. The primary outcome was the percent time sensor-measured glucose was in target range 70-180 mg/dL (time in range [TIR]) on days 3-14 of each arm, and key secondary outcomes included mean continuous glucose monitoring (CGM) glucose and the percent time sensor-measured glucose was in hypoglycemic range <54 mg/dL. RESULTS: TIR was significantly higher in the BP arm than the UC arm (75 ± 11% vs. 62 ± 22%, P = 0.001). Mean CGM glucose was lower in the BP arm than in the UC arm (150 ± 19 vs. 171 ± 45 mg/dL, P = 0.007). There was no significant difference in percent time with sensor-measured glucose <54 mg/dL (0.27% vs. 0.36%, P = 1.0), although self-reported symptomatic hypoglycemia episodes were higher during the BP arm than the UC arm (0.7 vs. 0.4 median episodes per day, P = 0.01). No episodes of diabetic ketoacidosis or severe hypoglycemia occurred in either arm. CONCLUSIONS: Adults with CFRD had improved glucose control without an increase in CGM-measured hypoglycemia with the BP compared with their UC, suggesting that this may be an important therapeutic option for this patient population.


Assuntos
Fibrose Cística , Diabetes Mellitus Tipo 1 , Hipoglicemia , Adulto , Humanos , Insulina/uso terapêutico , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/tratamento farmacológico , Fibrose Cística/tratamento farmacológico , Biônica , Glicemia , Sistemas de Infusão de Insulina , Hipoglicemiantes/uso terapêutico , Hipoglicemia/tratamento farmacológico , Insulina Regular Humana/uso terapêutico , Pâncreas
2.
N Engl J Med ; 387(13): 1161-1172, 2022 09 29.
Artigo em Inglês | MEDLINE | ID: mdl-36170500

RESUMO

BACKGROUND: Currently available semiautomated insulin-delivery systems require individualized insulin regimens for the initialization of therapy and meal doses based on carbohydrate counting for routine operation. In contrast, the bionic pancreas is initialized only on the basis of body weight, makes all dose decisions and delivers insulin autonomously, and uses meal announcements without carbohydrate counting. METHODS: In this 13-week, multicenter, randomized trial, we randomly assigned in a 2:1 ratio persons at least 6 years of age with type 1 diabetes either to receive bionic pancreas treatment with insulin aspart or insulin lispro or to receive standard care (defined as any insulin-delivery method with unblinded, real-time continuous glucose monitoring). The primary outcome was the glycated hemoglobin level at 13 weeks. The key secondary outcome was the percentage of time that the glucose level as assessed by continuous glucose monitoring was below 54 mg per deciliter; the prespecified noninferiority limit for this outcome was 1 percentage point. Safety was also assessed. RESULTS: A total of 219 participants 6 to 79 years of age were assigned to the bionic-pancreas group, and 107 to the standard-care group. The glycated hemoglobin level decreased from 7.9% to 7.3% in the bionic-pancreas group and did not change (was at 7.7% at both time points) in the standard-care group (mean adjusted difference at 13 weeks, -0.5 percentage points; 95% confidence interval [CI], -0.6 to -0.3; P<0.001). The percentage of time that the glucose level as assessed by continuous glucose monitoring was below 54 mg per deciliter did not differ significantly between the two groups (13-week adjusted difference, 0.0 percentage points; 95% CI, -0.1 to 0.04; P<0.001 for noninferiority). The rate of severe hypoglycemia was 17.7 events per 100 participant-years in the bionic-pancreas group and 10.8 events per 100 participant-years in the standard-care group (P = 0.39). No episodes of diabetic ketoacidosis occurred in either group. CONCLUSIONS: In this 13-week, randomized trial involving adults and children with type 1 diabetes, use of a bionic pancreas was associated with a greater reduction than standard care in the glycated hemoglobin level. (Funded by the National Institute of Diabetes and Digestive and Kidney Diseases and others; ClinicalTrials.gov number, NCT04200313.).


Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemiantes , Insulina Aspart , Sistemas de Infusão de Insulina , Insulina Lispro , Adolescente , Adulto , Idoso , Biônica/instrumentação , Glicemia/análise , Automonitorização da Glicemia/instrumentação , Automonitorização da Glicemia/métodos , Criança , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hemoglobinas Glicadas/análise , Humanos , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/efeitos adversos , Hipoglicemiantes/uso terapêutico , Insulina/administração & dosagem , Insulina/efeitos adversos , Insulina/uso terapêutico , Insulina Aspart/administração & dosagem , Insulina Aspart/efeitos adversos , Insulina Aspart/uso terapêutico , Sistemas de Infusão de Insulina/efeitos adversos , Insulina Lispro/administração & dosagem , Insulina Lispro/efeitos adversos , Insulina Lispro/uso terapêutico , Pessoa de Meia-Idade , Adulto Jovem
3.
J Res Nurs ; 27(1-2): 157-165, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35392208

RESUMO

Background: Approximately 25 million people around the world identify as transgender, and the numbers are growing. While visibility of transgender communities has increased, significant healthcare disparities remain. Transgender individuals report being less inclined to share their sex assigned at birth due to fear of stigmatization and mistrust of the medical community. The mistrust and inequity experienced by transgender individuals are not limited to clinical care and may extend to clinical research as well. Aim and method: The aim of this paper is to start a conversation about barriers to participating in research and the role of research staff, specifically the Clinical Research Nurse, in promoting engagement of transgender individuals in clinical research trials. Discussion and conclusions: A discussion of safety considerations, data integrity, and implications for data management is included. Because disparities may result in large part from lack of education and knowledge on best practices for providing care for this population, recommendations for fostering a culture of competence and gender-affirming care among research professionals featuring the role of the research nurse will be discussed.

5.
Diabetes Technol Ther ; 22(11): 846-852, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32453604

RESUMO

Background: There is a dearth of comparative accuracy studies of continuous glucose monitoring (CGM) devices in the home-use setting, and none with the Eversense implantable CGM. Methods: We evaluated the accuracy of the Dexcom G5, Abbott Freestyle Libre Pro, and Senseonics Eversense during a 6-week free-living home-use bionic pancreas study involving 23 subjects with type 1 diabetes who wore all three devices concurrently. The primary outcome was the mean absolute relative difference (MARD) between CGM readings and point-of-care (POC) plasma-glucose (PG) values obtained approximately twice daily by the subjects. We compared PG values with CGM readings when available from all three CGMs in the 5 min preceding the PG values (n = 829 sets). Since the Libre Pro records readings every 15 min, we also did a two-way comparison between the G5 and the Eversense with a higher number of comparisons (n = 2277 sets). Results: All three CGM systems produced higher average MARDs than during in-clinic studies. However, since all three CGM systems were worn by the same individuals and used the same meter for comparator PG measurements, we could directly compare their performances. In the three-way comparison, Eversense achieved the lowest nominal MARD (14.8%) followed by Dexcom G5 (16.3%) and Libre Pro (18.0%) (Eversense vs. Libre Pro P = 0.004, other comparisons P = NS). There was a statistically significant difference (P = 0.008) in the two-way comparison of the MARDs for Eversense (15.1%) and G5 (16.9%). Conclusions: The point accuracy of the Eversense was better than two other CGMs when compared with POC PG values.


Assuntos
Automonitorização da Glicemia/instrumentação , Diabetes Mellitus Tipo 1 , Glicemia/análise , Diabetes Mellitus Tipo 1/diagnóstico , Humanos , Pâncreas Artificial , Reprodutibilidade dos Testes
6.
Lancet ; 389(10067): 369-380, 2017 01 28.
Artigo em Inglês | MEDLINE | ID: mdl-28007348

RESUMO

BACKGROUND: The safety and effectiveness of a continuous, day-and-night automated glycaemic control system using insulin and glucagon has not been shown in a free-living, home-use setting. We aimed to assess whether bihormonal bionic pancreas initialised only with body mass can safely reduce mean glycaemia and hypoglycaemia in adults with type 1 diabetes who were living at home and participating in their normal daily routines without restrictions on diet or physical activity. METHODS: We did a random-order crossover study in volunteers at least 18 years old who had type 1 diabetes and lived within a 30 min drive of four sites in the USA. Participants were randomly assigned (1:1) in blocks of two using sequentially numbered sealed envelopes to glycaemic regulation with a bihormonal bionic pancreas or usual care (conventional or sensor-augmented insulin pump therapy) first, followed by the opposite intervention. Both study periods were 11 days in length, during which time participants continued all normal activities, including athletics and driving. The bionic pancreas was initialised with only the participant's body mass. Autonomously adaptive dosing algorithms used data from a continuous glucose monitor to control subcutaneous delivery of insulin and glucagon. The coprimary outcomes were the mean glucose concentration and time with continuous glucose monitoring (CGM) glucose concentration less than 3·3 mmol/L, analysed over days 2-11 in participants who completed both periods of the study. This trial is registered with ClinicalTrials.gov, number NCT02092220. FINDINGS: We randomly assigned 43 participants between May 6, 2014, and July 3, 2015, 39 of whom completed the study: 20 who were assigned to bionic pancreas first and 19 who were assigned to the comparator first. The mean CGM glucose concentration was 7·8 mmol/L (SD 0·6) in the bionic pancreas period versus 9·0 mmol/L (1·6) in the comparator period (difference 1·1 mmol/L, 95% CI 0·7-1·6; p<0·0001), and the mean time with CGM glucose concentration less than 3·3 mmol/L was 0·6% (0·6) in the bionic pancreas period versus 1·9% (1·7) in the comparator period (difference 1·3%, 95% CI 0·8-1·8; p<0·0001). The mean nausea score on the Visual Analogue Scale (score 0-10) was greater during the bionic pancreas period (0·52 [SD 0·83]) than in the comparator period (0·05 [0·17]; difference 0·47, 95% CI 0·21-0·73; p=0·0024). Body mass and laboratory parameters did not differ between periods. There were no serious or unexpected adverse events in the bionic pancreas period of the study. INTERPRETATION: Relative to conventional and sensor-augmented insulin pump therapy, the bihormonal bionic pancreas, initialised only with participant weight, was able to achieve superior glycaemic regulation without the need for carbohydrate counting. Larger and longer studies are needed to establish the long-term benefits and risks of automated glycaemic management with a bihormonal bionic pancreas. FUNDING: National Institute of Diabetes and Digestive and Kidney Diseases of the National Institutes of Health, and National Center for Advancing Translational Sciences.


Assuntos
Diabetes Mellitus Tipo 1/tratamento farmacológico , Glucagon/administração & dosagem , Hormônios/administração & dosagem , Hipoglicemiantes/administração & dosagem , Sistemas de Infusão de Insulina , Insulina/administração & dosagem , Pâncreas Artificial , Adulto , Biônica , Glicemia/metabolismo , Estudos Cross-Over , Diabetes Mellitus Tipo 1/metabolismo , Feminino , Glucagon/uso terapêutico , Hormônios/uso terapêutico , Humanos , Hipoglicemia/induzido quimicamente , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica , Náusea/induzido quimicamente , Adulto Jovem
7.
Lancet Diabetes Endocrinol ; 4(3): 233-243, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26850709

RESUMO

BACKGROUND: The safety and efficacy of continuous, multiday, automated glycaemic management has not been tested in outpatient studies of preadolescent children with type 1 diabetes. We aimed to compare the safety and efficacy of a bihormonal bionic pancreas versus conventional insulin pump therapy in this population of patients in an outpatient setting. METHODS: In this randomised, open-label, crossover study, we enrolled preadolescent children (aged 6-11 years) with type 1 diabetes (diagnosed for ≥1 year) who were on insulin pump therapy, from two diabetes camps in the USA. With the use of sealed envelopes, participants were randomly assigned in blocks of two to either 5 days with the bionic pancreas or conventional insulin pump therapy (control) as the first intervention, followed by a 3 day washout period and then 5 days with the other intervention. Study allocation was not masked. The autonomously adaptive algorithm of the bionic pancreas received data from a continuous glucose monitoring (CGM) device to control subcutaneous delivery of insulin and glucagon. Conventional insulin pump therapy was administered by the camp physicians and other clinical staff in accordance with their established protocols; participants also wore a CGM device during the control period. The coprimary outcomes, analysed by intention to treat, were mean CGM-measured glucose concentration and the proportion of time with a CGM-measured glucose concentration below 3·3 mmol/L, on days 2-5. This study is registered with ClinicalTrials.gov, number NCT02105324. FINDINGS: Between July 20, and Aug 19, 2014, 19 children with a mean age of 9·8 years (SD 1·6) participated in and completed the study. The bionic pancreas period was associated with a lower mean CGM-measured glucose concentration on days 2-5 than was the control period (7·6 mmol/L [SD 0·6] vs 9·3 mmol/L [1·7]; p=0·00037) and a lower proportion of time with a CGM-measured glucose concentration below 3·3 mmol/L on days 2-5 (1·2% [SD 1·1] vs 2·8% [1·2]; p<0·0001). The median number of carbohydrate interventions given per participant for hypoglycaemia on days 1-5 (ie, glucose <3·9 mmol/L) was lower during the bionic pancreas period than during the control period (three [range 0-8] vs five [0-14]; p=0·037). No episodes of severe hypoglycaemia were recorded. Medium-to-large concentrations of ketones (range 0·6-3·6 mmol/dL) were reported on seven occasions in five participants during the control period and on no occasion during the bionic pancreas period (p=0·063). INTERPRETATION: The improved mean glycaemia and reduced hypoglycaemia with the bionic pancreas relative to insulin pump therapy in preadolescent children with type 1 diabetes in a diabetes camp setting is a promising finding. Studies of a longer duration during which children use the bionic pancreas during their normal routines at home and school should be done to investigate the potential for use of the bionic pancreas in real-world settings. FUNDING: The Leona M and Harry B Helmsley Charitable Trust and the US National Institute of Diabetes and Digestive and Kidney Diseases.


Assuntos
Diabetes Mellitus Tipo 1/terapia , Glucagon/uso terapêutico , Hipoglicemiantes/uso terapêutico , Sistemas de Infusão de Insulina/efeitos adversos , Insulina/uso terapêutico , Pâncreas Artificial/efeitos adversos , Glicemia/efeitos dos fármacos , Criança , Estudos Cross-Over , Diabetes Mellitus Tipo 1/tratamento farmacológico , Feminino , Glucagon/administração & dosagem , Humanos , Hipoglicemiantes/administração & dosagem , Insulina/administração & dosagem , Masculino , Monitorização Fisiológica , Fatores de Tempo , Resultado do Tratamento
8.
N Engl J Med ; 371(4): 313-325, 2014 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-24931572

RESUMO

BACKGROUND: The safety and effectiveness of automated glycemic management have not been tested in multiday studies under unrestricted outpatient conditions. METHODS: In two random-order, crossover studies with similar but distinct designs, we compared glycemic control with a wearable, bihormonal, automated, "bionic" pancreas (bionic-pancreas period) with glycemic control with an insulin pump (control period) for 5 days in 20 adults and 32 adolescents with type 1 diabetes mellitus. The automatically adaptive algorithm of the bionic pancreas received data from a continuous glucose monitor to control subcutaneous delivery of insulin and glucagon. RESULTS: Among the adults, the mean plasma glucose level over the 5-day bionic-pancreas period was 138 mg per deciliter (7.7 mmol per liter), and the mean percentage of time with a low glucose level (<70 mg per deciliter [3.9 mmol per liter]) was 4.8%. After 1 day of automatic adaptation by the bionic pancreas, the mean (±SD) glucose level on continuous monitoring was lower than the mean level during the control period (133±13 vs. 159±30 mg per deciliter [7.4±0.7 vs. 8.8±1.7 mmol per liter], P<0.001) and the percentage of time with a low glucose reading was lower (4.1% vs. 7.3%, P=0.01). Among the adolescents, the mean plasma glucose level was also lower during the bionic-pancreas period than during the control period (138±18 vs. 157±27 mg per deciliter [7.7±1.0 vs. 8.7±1.5 mmol per liter], P=0.004), but the percentage of time with a low plasma glucose reading was similar during the two periods (6.1% and 7.6%, respectively; P=0.23). The mean frequency of interventions for hypoglycemia among the adolescents was lower during the bionic-pancreas period than during the control period (one per 1.6 days vs. one per 0.8 days, P<0.001). CONCLUSIONS: As compared with an insulin pump, a wearable, automated, bihormonal, bionic pancreas improved mean glycemic levels, with less frequent hypoglycemic episodes, among both adults and adolescents with type 1 diabetes mellitus. (Funded by the National Institute of Diabetes and Digestive and Kidney Diseases and others; ClinicalTrials.gov numbers, NCT01762059 and NCT01833988.).


Assuntos
Diabetes Mellitus Tipo 1/terapia , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Pâncreas Artificial , Adolescente , Adulto , Idoso , Biônica , Glicemia/metabolismo , Criança , Estudos Cross-Over , Diabetes Mellitus Tipo 1/tratamento farmacológico , Feminino , Humanos , Hipoglicemia/etiologia , Sistemas de Infusão de Insulina , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica , Pâncreas Artificial/efeitos adversos , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...