Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Phys Rev Lett ; 111(15): 153902, 2013 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-24160602

RESUMO

We report a measurement of the large optical transmission matrix (TM) of a complex turbid medium. The TM is acquired using polarization-sensitive, full-field interferometric microscopy equipped with a rotating galvanometer mirror. It is represented with respect to input and output bases of optical modes, which correspond to plane wave components of the respective illumination and transmitted waves. The modes are sampled so finely in angular spectrum space that their number exceeds the total number of resolvable modes for the illuminated area of the sample. As such, we investigate the singular value spectrum of the TM in order to detect evidence of open transmission channels, predicted by random-matrix theory. Our results comport with theoretical expectations, given the experimental limitations of the system. We consider the impact of these limitations on the usefulness of transmission matrices in optical measurements.


Assuntos
Óptica e Fotônica/instrumentação , Óptica e Fotônica/métodos , Microscopia de Interferência/instrumentação , Microscopia de Interferência/métodos , Modelos Teóricos , Nanopartículas/química , Nefelometria e Turbidimetria , Teoria Quântica , Espalhamento de Radiação , Óxido de Zinco/química
2.
Opt Express ; 21(19): 22453-63, 2013 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-24104134

RESUMO

We present synthetic Fourier transform light scattering, a method for measuring extended angle-resolved light scattering (ARLS) from individual microscopic samples. By measuring the light fields scattered from the sample plane and numerically synthesizing them in Fourier space, the angle range of the ARLS patterns is extended up to twice the numerical aperture of the imaging system with unprecedented sensitivity and precision. Extended ARLS patterns of individual microscopic polystyrene beads, healthy human red blood cells (RBCs), and Plasmodium falciparum-parasitized RBCs are presented.


Assuntos
Algoritmos , Eritrócitos/citologia , Eritrócitos/parasitologia , Nefelometria e Turbidimetria/métodos , Plasmodium falciparum/citologia , Análise de Fourier , Humanos , Luz , Espalhamento de Radiação
3.
Sci Rep ; 3: 1909, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23714766

RESUMO

Optical transmission through complex media such as biological tissue is fundamentally limited by multiple light scattering. Precise control of the optical wavefield potentially holds the key to advancing a broad range of light-based techniques and applications for imaging or optical delivery. We present a simple and robust digital optical phase conjugation (DOPC) implementation for suppressing multiple light scattering. Utilizing wavefront shaping via a spatial light modulator (SLM), we demonstrate its turbidity-suppression capability by reconstructing the image of a complex two-dimensional wide-field target through a highly scattering medium. Employing an interferometer with a Sagnac-like ring design, we successfully overcome the challenging alignment and wavefront-matching constraints in DOPC, reflecting the requirement that the forward- and reverse-propagation paths through the turbid medium be identical. By measuring the output response to digital distortion of the SLM write pattern, we validate the sub-wavelength sensitivity of the system.


Assuntos
Iluminação/métodos , Nefelometria e Turbidimetria/instrumentação , Dispositivos Ópticos , Imagem Óptica , Simulação por Computador , Desenho de Equipamento , Cristais Líquidos , Espalhamento de Radiação , Processamento de Sinais Assistido por Computador , Óxido de Zinco/química
4.
Phys Rev Lett ; 111(24): 243901, 2013 Dec 13.
Artigo em Inglês | MEDLINE | ID: mdl-24483661

RESUMO

Multiple scatterings occurring in a turbid medium attenuate the intensity of propagating waves. Here, we propose a method to efficiently deliver light energy to the desired target depth in a scattering medium. We measure the time-resolved reflection matrix of a scattering medium using coherent time-gated detection. From this matrix, we derive and experimentally implement an incident wave pattern that optimizes the detected signal corresponding to a specific arrival time. This leads to enhanced light delivery at the target depth. The proposed method will lay a foundation for efficient phototherapy and deep-tissue in vivo imaging in the near future.


Assuntos
Radiação Eletromagnética , Luz , Nefelometria e Turbidimetria/métodos , Espalhamento de Radiação , Nefelometria e Turbidimetria/instrumentação
5.
Appl Phys Lett ; 101(8): 84101, 2012 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-22991482

RESUMO

We present an imaging modality capable of providing high-speed optical dispersion measurements of live cells. The technique permits wide-field measurement of the optical phase shifts introduced by a sample for multiple discrete wavelengths in a single image capture. Utilizing spatial modulation and the wavelength dependence of the interference-fringe spacing, average refractive index as a function of wavelength is obtained, yielding optical dispersion measurements of the sample under observation. Because of its simple and low-cost design, the technique can be readily integrated into a standard microscope to collect additional diagnostic information about biological cells.

6.
Acta Biomater ; 8(11): 4130-8, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22820310

RESUMO

Sickle cell disease (SCD) is characterized by the abnormal deformation of red blood cells (RBCs) in the deoxygenated condition, as their elongated shape leads to compromised circulation. The pathophysiology of SCD is influenced by both the biomechanical properties of RBCs and their hemodynamic properties in the microvasculature. A major challenge in the study of SCD involves accurate characterization of the biomechanical properties of individual RBCs with minimum sample perturbation. Here we report the biomechanical properties of individual RBCs from a SCD patient using a non-invasive laser interferometric technique. We optically measure the dynamic membrane fluctuations of RBCs. The measurements are analyzed with a previously validated membrane model to retrieve key mechanical properties of the cells: bending modulus; shear modulus; area expansion modulus; and cytoplasmic viscosity. We find that high cytoplasmic viscosity at ambient oxygen concentration is principally responsible for the significantly decreased dynamic membrane fluctuations in RBCs with SCD, and that the mechanical properties of the membrane cortex of irreversibly sickled cells (ISCs) are different from those of the other types of RBCs in SCD.


Assuntos
Anemia Falciforme/sangue , Anemia Falciforme/patologia , Eritrócitos Anormais/patologia , Óptica e Fotônica/métodos , Anemia Falciforme/fisiopatologia , Fenômenos Biomecânicos , Forma Celular , Módulo de Elasticidade , Membrana Eritrocítica/metabolismo , Hemoglobinas/metabolismo , Humanos , Microscopia , Modelos Biológicos , Viscosidade
7.
IEEE Photonics Technol Lett ; 24(20): 1812-1814, 2012 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-29386859

RESUMO

We report a near-common-path self-reference quantitative phase microscope, wherein a quantitative phase image is formed through the off-axis interference of the sample wave with a 180-degree rotated version of itself. A pair of dove prisms, oriented in different directions, is used to effect the relative transformation between the beams. Our technique features a simple optical design that requires no maintenance, rendering it accessible to nonspecialists in the field of optics. Additionally, its variable magnification and low-noise phase measurement capabilities make it suitable for high-accuracy imaging of biological samples of different sizes.

8.
J Biomed Opt ; 16(2): 020506, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21361662

RESUMO

We present a technique to reduce speckle in optical coherence tomography images of soft tissues. An average is formed over a set of B-scans that have been decorrelated by viscoelastic creep strain. The necessary correction for the deformation-induced spatial distortions between B-scans is achieved through geometrical co-registration using an affine transformation. Speckle reduction by up to a factor of 1.65 is shown in images of tissue-mimicking soft fibrin phantoms and excised human lymph node tissue with no observable loss of spatial resolution.


Assuntos
Artefatos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Tomografia de Coerência Óptica/instrumentação , Tomografia de Coerência Óptica/métodos , Módulo de Elasticidade/fisiologia , Humanos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Viscosidade
9.
Opt Express ; 18(24): 25116-26, 2010 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-21164858

RESUMO

Fourier-holographic light scattering spectroscopy is applied to record complex angular scattering spectra of two- and three-dimensional samples over a wide field of view. We introduce a computational depth sectioning technique and, for the first time, demonstrate that a single-exposure hologram can generate a quantitative, three-dimensional map of particle sizes and locations over several cubic millimeters with micrometer resolution. Such spatially resolved maps of particle sizes are generated by Mie-inversion and could not be ascertained from the directly reconstructed intensity-distribution images. We also demonstrate synthesis of multiple angular scattering intensity spectra to increase the angular range and improve size detection sensitivity.


Assuntos
Holografia/métodos , Aumento da Imagem/métodos , Imageamento Tridimensional/métodos , Microesferas , Tamanho da Partícula , Espalhamento de Radiação , Análise Espectral/métodos , Luz
10.
Opt Lett ; 35(14): 2445-7, 2010 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-20634858

RESUMO

We present a speckle reduction technique for optical coherence tomography based on strain compounding. Decorrelation is introduced between B-scans by altering the sample's strain. A theoretical description of the technique, based on a transfer-function formalism, and experimental results on silicone phantoms are presented. Nearly complete decorrelation between successive B-scan speckle patterns was observed for a variation in strain of 0.045. Strain compounding by averaging nine B-scans, with 0.003 strain increments between them, resulted in a 1.5-fold reduction in speckle contrast ratio.


Assuntos
Tomografia de Coerência Óptica/métodos , Imagens de Fantasmas
11.
Opt Lett ; 35(12): 1998-2000, 2010 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-20548365

RESUMO

Angular diversity is a successful speckle-reduction technique in optical coherence tomography (OCT). We employ angle-dependent detection for a different purpose: to distinguish the singly backscattered and multiply scattered signal components. Single backscattering is highly correlated over a large range of detection angles; multiple scattering rapidly decorrelates as the angle is varied. Theoretical justification is provided using a linear-systems description of the OCT imaging process; detection of multiple scattering is corroborated experimentally.


Assuntos
Diagnóstico por Imagem/métodos , Tomografia de Coerência Óptica/métodos
12.
Opt Lett ; 35(8): 1136-8, 2010 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-20410944

RESUMO

We show for the first time, to our knowledge, high-resolution wide-field images of biological samples recorded using coherent aperture-synthesis Fourier holography. To achieve this, we combined off-axis plane-wave polarized illumination with an axial sample rotation and polarization-sensitive collection of backscattered light. We synthesized 180 Fourier holograms using an efficient postdetection phase-matching correlation scheme. The result was an annular spatial frequency-space synthetic aperture (NA=0.93) with an effective area 25 times larger than that due to a single hologram. A high-resolution high-contrast microscopic reconstruction of biological tissue was computed over a sample area of 9 mm(2) from holograms acquired at 34 mm working distance.


Assuntos
Holografia/métodos , Microscopia/métodos , Humanos , Processamento de Imagem Assistida por Computador , Linfonodos/citologia , Linfonodos/patologia
13.
Opt Express ; 17(24): 21762-72, 2009 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-19997419

RESUMO

We present a novel sample arm arrangement for dynamic optical coherence elastography based on excitation by a ring actuator. The actuator enables coincident excitation and imaging to be performed on a sample, facilitating in vivo operation. Sub-micrometer vibrations in the audio frequency range were coupled to samples that were imaged using optical coherence tomography. The resulting vibration amplitude and microstrain maps are presented for bilayer silicone phantoms and multiple skin sites on a human subject. Contrast based on the differing elastic properties is shown, notably between the epidermis and dermis. The results constitute the first demonstration of a practical means of performing in vivo dynamic optical coherence elastography on a human subject.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Tomografia de Coerência Óptica/métodos , Adulto , Algoritmos , Técnicas de Imagem por Elasticidade/instrumentação , Desenho de Equipamento , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Interferometria/métodos , Masculino , Imagens de Fantasmas , Espalhamento de Radiação , Pele/patologia
14.
Opt Express ; 17(10): 7873-92, 2009 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-19434119

RESUMO

We utilize synthetic-aperture Fourier holographic microscopy to resolve micrometer-scale microstructure over millimeter-scale fields of view. Multiple holograms are recorded, each registering a different, limited region of the sample object's Fourier spectrum. They are "stitched together" to generate the synthetic aperture. A low-numerical-aperture (NA) objective lens provides the wide field of view, and the additional advantages of a long working distance, no immersion fluids, and an inexpensive, simple optical system. Following the first theoretical treatment of the technique, we present images of a microchip target derived from an annular synthetic aperture (NA = 0.61) whose area is 15 times that due to a single hologram (NA = 0.13); they exhibit a corresponding qualitative improvement. We demonstrate that a high-quality reconstruction may be obtained from a limited sub-region of Fourier space, if the object's structural information is concentrated there.

15.
Opt Express ; 15(26): 18033-49, 2007 Dec 24.
Artigo em Inglês | MEDLINE | ID: mdl-19551101

RESUMO

Multiple scattering is one of the main degrading influences in optical coherence tomography, but to date its presence in an image can only be indirectly inferred. We present a polarization-sensitive method that shows the potential to detect it more directly, based on the degree to which the detected polarization state at any given image point is correlated with the mean state over the surrounding region. We report the validation of the method in microsphere suspensions, showing a strong dependence of the degree of correlation upon the extent to which multiply scattered light is coherently detected. We demonstrate the method's utility in various tissues, including chicken breast ex vivo and human skin and nailfold in vivo.


Assuntos
Algoritmos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Nefelometria e Turbidimetria/métodos , Tomografia de Coerência Óptica/métodos , Luz , Espalhamento de Radiação
16.
Opt Express ; 15(23): 15002-10, 2007 Nov 12.
Artigo em Inglês | MEDLINE | ID: mdl-19550781

RESUMO

We rigorously account for the effects of multiparticle light scattering from a fractal sphere aggregate in order to simulate the optical properties of a soft biological tissue, human skin. Using a computational method that extends Mie theory to the multisphere case, we show that multiparticle scattering significantly affects the computed optical properties, resulting in a reduction in both scattering coefficient and anisotropy for the wavelengths simulated, as well as a significantly enhanced forward peak in the simulated phase function. The model is extended to incorporate the contribution of Rayleigh scatterers, which we show is required to obtain reasonable agreement with experimentally measured optical properties of skin tissue.

17.
Phys Rev Lett ; 97(16): 168102, 2006 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-17155439

RESUMO

We report a new synthetic aperture optical microscopy in which high-resolution, wide-field amplitude and phase images are synthesized from a set of Fourier holograms. Each hologram records a region of the complex two-dimensional spatial frequency spectrum of an object, determined by the illumination field's spatial and spectral properties and the collection angle and solid angle. We demonstrate synthetic microscopic imaging in which spatial frequencies that are well outside the modulation transfer function of the collection optical system are recorded while maintaining the long working distance and wide field of view.


Assuntos
Análise de Fourier , Holografia/métodos , Microscopia/métodos , Óptica e Fotônica , Holografia/instrumentação , Microscopia/instrumentação
18.
Opt Lett ; 31(2): 190-2, 2006 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-16441026

RESUMO

We present theoretical calculations, based on a random phasor sum model, which show that the optical coherence tomography speckle contrast ratio is dependent on the local density of scattering particles in a sample, provided that the effective number of scatterers in the probed volume is less than about five. We confirm these theoretical predictions experimentally, using suspensions of microspheres in water. The observed contrast ratios vary in value from the Rayleigh limit of 0.52 to in excess of 2, suggesting that the contrast ratio could be useful in optical coherence tomography, particularly when imaging in ultrahigh-resolution regimes.


Assuntos
Algoritmos , Artefatos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Armazenamento e Recuperação da Informação/métodos , Modelos Estatísticos , Tomografia de Coerência Óptica/métodos , Luz , Reprodutibilidade dos Testes , Espalhamento de Radiação , Sensibilidade e Especificidade , Estatística como Assunto
19.
Opt Express ; 14(23): 11088-102, 2006 Nov 13.
Artigo em Inglês | MEDLINE | ID: mdl-19529524

RESUMO

We utilize Fourier-holographic light scattering angular spectroscopy to record the spatially resolved complex angular scattering spectra of samples over wide fields of view in a single or few image captures. Without resolving individual scatterers, we are able to generate spatially-resolved particle size maps for samples composed of spherical scatterers, by comparing generated spectra with Mie-theory predictions. We present a theoretical discussion of the fundamental principles of our technique and, in addition to the sphere samples, apply it experimentally to a biological sample which comprises red blood cells. Our method could possibly represent an efficient alternative to the time-consuming and laborious conventional procedure in light microscopy of image tiling and inspection, for the characterization of microscopic morphology over wide fields of view.

20.
Opt Lett ; 30(24): 3305-7, 2005 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-16389813

RESUMO

We show for what is the first time to our knowledge that digital Fourier holography can be used to record spatially resolved angular light scattering spectra from microscopically structured samples. This is achieved in one or a few digital image captures over large millimeter-scale fields of view. Such spectra are a sensitive measure of microscopic morphology, with wide applications in biological and medical imaging. We demonstrate good agreement between results of experiment and Mie theory for the angular scattering spectra of microspheres in water extracted from local regions within reconstructed 2 x 1 millimeter image sets.


Assuntos
Holografia/instrumentação , Aumento da Imagem/instrumentação , Refratometria/instrumentação , Análise Espectral/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Análise de Fourier , Imagens de Fantasmas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA