Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
1.
EuroIntervention ; 13(17): 2036-2046, 2018 04 20.
Artigo em Inglês | MEDLINE | ID: mdl-28741575

RESUMO

AIMS: This acute in vivo study sought to provide insights regarding the feasibility of performing complex bifurcation stenting with Magmaris magnesium alloy bioresorbable scaffolds (Biotronik, Bulach, Switzerland). METHODS AND RESULTS: Twenty-five New Zealand White rabbits underwent stenting of non-diseased aorto-iliac bifurcations with the Magmaris using provisional (PS; n=5), culotte (n=6), modified T (n=6), or T and protrusion (TAP, n=8) stenting techniques. Angiography, optical coherence tomography and micro-computed tomography were performed. Angiographic results were good without evidence of side branch (SB) compromise. In 9/25 procedures, strut fractures were identified with minimal luminal compromise in two cases. PS opened the SB optimally without evidence of scaffold compromise. Culotte resulted in complete bifurcation coverage and good scaffold expansion; single strut fractures were present in three out of six and double fractures in one out of six procedures. Modified T and TAP resulted in complete bifurcation coverage, minimal neocarina double-strut layers and good expansion. In two out of six modified T procedures, strut fractures were present with SB scaffold deformity present in an additional two out of six procedures. In three out of eight TAP procedures, strut fractures were present without compromising overall scaffold integrity. CONCLUSIONS: Bifurcation stenting using Magmaris appears feasible. PS with additional TAP whenever needed seems a reasonable approach. Whenever a two-stent technique is planned, TAP appears most favourable whilst modified T and culotte stenting should probably be avoided.


Assuntos
Doença da Artéria Coronariana , Vasos Coronários , Stents Farmacológicos , Magnésio/farmacologia , Intervenção Coronária Percutânea/instrumentação , Alicerces Teciduais , Animais , Materiais Biocompatíveis/farmacologia , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/fisiologia , Vasos Coronários/cirurgia , Modelos Animais de Doenças , Estudos de Viabilidade , Teste de Materiais , Modelos Anatômicos , Imagem Multimodal , Intervenção Coronária Percutânea/métodos , Coelhos , Tomografia de Coerência Óptica/métodos , Microtomografia por Raio-X/métodos
3.
Catheter Cardiovasc Interv ; 89(1): 78-92, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26892943

RESUMO

As the LCx is closely related to the mitral valve annulus, it is susceptible to perioperative injury. Various underlying mechanisms, predisposing factors, and therapeutic strategies have been suggested but disagreement exists. Using a MeSH terms-based PubMed search, 44 cases of mitral valve surgery-related LCx injury were detected, including our 4 cases. We provide a comprehensive review of current knowledge regarding mitral valve surgery-related left circumflex coronary artery (LCx) injury. Preoperative coronary angiography was performed in 55% (n = 24). Coronary abnormalities were present in 11% (n = 5). Coronary dominance was reported in 73% (n = 32), predominantly showing left (69%, n = 22) or balanced (19%, n = 6) circulations. Right coronary dominance was present in 12% (n = 4). Ischemia was detected in the perioperative or early postoperative phase in 86% (n = 30). Delayed symptoms were present in 14% (n = 5). Echocardiography demonstrated new regional wall motion abnormalities in 80% (n = 24), but was negative in 20% (n = 6) despite coronary compromise. Electrocardiography showed myocardial ischemia in 97% (n = 34), including regional ST-segment elevations in 68% (n = 23). Primary treatment was surgical in 42% (n = 15) and percutaneous in 58% (n = 21), reporting success ratios of 87% (n = 13) and 81% (n = 17), respectively. We confirm an augmented risk of mitral valve surgery-related LCx injury in balanced or left-dominant coronary circulations. Preoperative knowledge of coronary anatomy does not preclude LCx injury. An anomalous LCx arising from the right coronary cusp was identified as a possible specific high-risk entity. Electrocardiographic monitoring and intraoperative echocardiography remain paramount to ensure a timely diagnosis and treatment. © 2016 Wiley Periodicals, Inc.


Assuntos
Vasos Coronários/lesões , Traumatismos Cardíacos/etiologia , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Anuloplastia da Valva Mitral/efeitos adversos , Valva Mitral/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Angioplastia Coronária com Balão/instrumentação , Angiografia por Tomografia Computadorizada , Angiografia Coronária/métodos , Anomalias dos Vasos Coronários/complicações , Anomalias dos Vasos Coronários/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Ecocardiografia Transesofagiana , Eletrocardiografia , Feminino , Traumatismos Cardíacos/diagnóstico por imagem , Traumatismos Cardíacos/terapia , Doenças das Valvas Cardíacas/complicações , Doenças das Valvas Cardíacas/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valor Preditivo dos Testes , Reoperação , Fatores de Risco , Stents , Resultado do Tratamento
5.
J Heart Valve Dis ; 25(2): 182-184, 2016 03.
Artigo em Inglês | MEDLINE | ID: mdl-27989062

RESUMO

Transcatheter aortic valve replacement (TAVR) is a valuable alternative in surgical high-risk patients with symptomatic aortic valve stenosis. Here, the case is presented of very early transcatheter heart valve degeneration, probably caused by a 'Venturi effect' of a severe paravalvular regurgitant jet. This ultimately led to a leaflet being in the open position, creating severe valvular regurgitation that necessitated classical surgical revision. The occurrence of paravalvular regurgitation, and its known relationship with an adverse prognosis after TAVR, demonstrates the clear need for innovative alterations in valve design to prevent this complication. Video 1: Angiography immediately after implantation of an Edwards SAPIEN 23 mm transcatheter heart valve, showing severe paravalvular aortic valve regurgitation. The implantation position is rather low. Video 2: Transesophageal echocardiography with 2-D color imaging showing aortic valve long-axis view at 131°, three days after implantation of an Edwards SAPIEN 23 mm transcatheter heart valve. Severe eccentric paravalvular aortic valve regurgitation is shown without a significant valvular component. The implantation position is rather low. Video 3: Transesophageal echocardiography with 2-D color imaging showing aortic valve long-axis view at 120°, one month after implantation of an Edwards SAPIEN 23 mm transcatheter heart valve. Severe combined valvular and paravalvular aortic valve regurgitation (grade 4/4) is shown.


Assuntos
Insuficiência da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Remoção de Dispositivo , Ecocardiografia Doppler em Cores , Ecocardiografia Transesofagiana , Feminino , Próteses Valvulares Cardíacas , Hemodinâmica , Humanos , Desenho de Prótese , Falha de Prótese , Reoperação , Substituição da Valva Aórtica Transcateter/instrumentação , Resultado do Tratamento
7.
Artigo em Inglês | MEDLINE | ID: mdl-27512090

RESUMO

BACKGROUND: Although bioresorbable scaffolds offer potential advantages compared with metallic drug-eluting stents in the treatment of complex coronary bifurcation lesions, there are concerns that the polymeric scaffold integrity may be compromised. This in vivo study sought to provide insights about the feasibility of performing complex bifurcation stenting with Absorb bioresorbable vascular scaffolds (Abbott Vascular, Santa Clara, CA). METHODS AND RESULTS: Twenty New Zealand white rabbits underwent stenting of the nondiseased aortoiliac bifurcation with bioresorbable vascular scaffolds using provisional (PS, n=5), culotte (n=5), modified-T (n=5), or T-and protrusion (n=5) stenting techniques. Angiography, optical coherence tomography, and microcomputed tomography were performed. Angiographic results were excellent without evidence of dissection or side branch (SB) compromise. PS optimally opened the SB ostium without deforming the main vessel (MV) bioresorbable vascular scaffolds, avoiding malapposition, and revealing a single connector fracture in 1 of 5 cases on microcomputed tomography. Culotte stenting resulted in complete bifurcation coverage with extensive segments of double-layered struts and inappropriately apposed struts at the bifurcation level in 3 of 5 cases. On microcomputed tomography, there was MV and SB scaffold distortion at the bifurcation with single strut fractures in 4 of 5 and double fractures in 1 of 5. Modified-T and T-and protrusion resulted in complete bifurcation coverage and in minimal double-strut layers at the neocarina. On microcomputed tomography, no strut fractures were present after modified-T, whereas in 3 of 5 T-and protrusion procedures single strut fractures were noted. CONCLUSIONS: Bifurcation stenting using bioresorbable vascular scaffolds is feasible with excellent angiographic results. PS with additional T-and protrusion whenever needed seems a reasonable approach. Whenever a 2-stent technique is planned, modified T-stenting appears the most promising.


Assuntos
Implantes Absorvíveis , Angioplastia Coronária com Balão/métodos , Imagem Multimodal , Alicerces Teciduais , Angioplastia Coronária com Balão/instrumentação , Animais , Angiografia Coronária , Imageamento Tridimensional , Coelhos , Stents , Tomografia de Coerência Óptica , Microtomografia por Raio-X
12.
Eur Heart J Qual Care Clin Outcomes ; 2(3): 184-192, 2016 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-29474610

RESUMO

AIMS: We assessed the impact of transcatheter aortic valve implantation (TAVI) on functional performance and quality of life (QoL) in a high-risk patient population with multiple comorbidities. METHODS AND RESULTS: Between January 2009 and December 2014, 145 high-risk patients (EuroSCORE II 7.3% [4.9; 14.9]) with severe symptomatic aortic valve stenosis (AS) underwent TAVI in a single centre. We prospectively evaluated New York Heart Association (NYHA) functional class, 6-minute walking distance (6MWD), and QoL using the validated Dutch version of the EuroQol-5D (EQ-5D) descriptive assessment and a visual analogue scale (EQ-VAS) at baseline, 30 days, as well as 6, 12, and 24 months after TAVI. All patients were eligible for analysis. New York Heart Association functional class improved significantly at 30-day, 6-, 12-, and 24-month follow-up (P < 0.001 for all). The absolute 6MWD improved significantly at 30 days (+19.3 ± 8.2 m; P= 0.0499) and at 6 months (+23.3 ± 8.1 m; P = 0.0194). A favourable trend was maintained at 12 months (+17.1 ± 8.8 m; P = 0.1879), whereas at 24 months 6MWD was similar to baseline values. No significant change in the descriptive assessment of QoL (EQ5D) was observed, whereas the EQ-VAS showed a significant improvement in QoL up to 24 months (P < 0.0180 for all time-points). CONCLUSION: In high-risk comorbid patients with symptomatic AS, TAVI results in a significant but temporary improvement of functional performance when assessed with objective measures of 6MWD but not of EQ-5D. Moreover, TAVI has a significant and sustained impact on subjective well-being and exercise capacity assessed with the EQ-VAS and NYHA score.

13.
Acta Gastroenterol Belg ; 78(4): 427-30, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26712055

RESUMO

We present a case of a 52-year old female patient with intermittent gastrointestinal bleeding and iron deficiency anaemia. Repeated endoscopic investigation revealed no diagnosis, but contrast-enhanced computed tomography showed a splenic artery pseudo-aneurysm secondary to chronic alcoholic pancreatitis. A distal pancreatectomy and splenectomy was performed. Hemosuccus pancreaticus is an uncommon cause of gastrointestinal bleeding, most frequently associated with chronic pancreatitis. Erosion of a peripancreatic artery by a pseudocyst can cause a pseudoaneurysm and rupture occurs in up to 10% of the cases. Bleeding from a pseudocyst wall or rupture of an atherosclerotic or traumatic aneurysm is rare. Angiography, contrast-enhanced computed tomography and endoscopic findings can be diagnostic in the majority of cases. Angiographic embolization or surgery are both therapeutic options depending on underlying nonvascular pancreas related indications requiring surgery. We discuss diagnostic pitfalls and current therapeutic strategies in the management of this disease.


Assuntos
Falso Aneurisma/complicações , Aneurisma Roto/complicações , Hemorragia Gastrointestinal/etiologia , Pancreatite Alcoólica/complicações , Artéria Esplênica , Doença Crônica , Feminino , Humanos , Pessoa de Meia-Idade
14.
J Heart Valve Dis ; 24(4): 436-8, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26897812
15.
Anaesthesiol Intensive Ther ; 47(2): 156-61, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25421924

RESUMO

More than a decade after the first randomised controlled trials with targeted temperature management (TTM), it remains the only treatment with proven favourable effect on postanoxemic brain damage after out-of-hospital cardiac arrest. Other well-known indications include neurotrauma, subarachnoidal haemorrhage, and intracranial hypertension. When possible pitfalls are taken into consideration when implementing TTM, the side effects are manageable. After the recent TTM trials, it seems that classic TTM (32-34°C) is as effective and safe as TTM at 36°C. This supports the belief that fever prevention is one of the pivotal mechanisms that account for the success of TTM. Uncertainty remains concerning cooling method, timing, speed of cooling and rewarming. New data indicates that TTM is safe and feasible in cardiogenic shock, one of its classic contra-indications. Moreover, there are limited indications that TTM might be considered as a therapy for cardiogenic shock per se.


Assuntos
Hipotermia Induzida , Choque Cardiogênico/terapia , Hemodinâmica , Humanos , Reaquecimento
16.
Ned Tijdschr Geneeskd ; 158: A7565, 2014.
Artigo em Holandês | MEDLINE | ID: mdl-25204444

RESUMO

In the past 10 years there have been major advances in the treatment of cardiac arrest by the application of therapeutic hypothermia (TH). TH is a safe treatment option, providing the physiological effects are taken into consideration and providing the potential pitfalls of application of hypothermia are avoided. TH (32-34°C) is just as safe and effective as cooling to 36°C ('near-normal temperature'). The benefit of TH is thus probably derived from the effective suppression of fever. The broad spectrum of pathophysiological mechanisms by which therapeutic hypothermia exerts its effect on organism in a hypoxic situation suggests a potential wider role for this therapy than in current daily clinical practice. Cardiogenic shock is no longer regarded as a contraindication for TH; in the past few years the safety and effectiveness of this treatment have been proven in patients with cardiogenic shock. In fact, the anti-ischaemic and positive inotropic effects of TH suggest that this treatment could be a potential treatment specifically for patients with cardiogenic shock.


Assuntos
Parada Cardíaca/terapia , Hipotermia Induzida , Temperatura Corporal/fisiologia , Humanos , Contração Miocárdica/fisiologia , Choque Cardiogênico/terapia , Resultado do Tratamento
18.
Clin Colorectal Cancer ; 12(1): 8-14, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23102544

RESUMO

Most chemotherapy regimens in colorectal cancer treatment are 5-fluorouracil (5-FU)/leucovorin or capecitabine-based. Cardiotoxicity is a less common but potentially lethal complication of 5-FU or capecitabine treatment, and some physicians might be unfamiliar with treatment alternatives. Rechallenging should be avoided because it carries a high risk of recurrence of the cardiac symptoms and prophylactic treatment is not always protective. Possible alternative treatment options to be considered are to replace the oral capecitabine or intravenous 5-FU by a 5-FU bolus regimen, by uracil-tegafur or tegafur/gimeracil/oteracil, both oral fluoropyrimidines combining a 5-FU prodrug with a dihydropyrimidine dehydrogenase (DPD) inhibitor, or by raltitrexed, a thymidilate synthase inhibitor whose metabolism is independent of DPD. Patients with advanced colorectal cancer and fluoropyrimidine-induced cardiotoxicity can be treated with other non-fluoropyrimidine related chemotherapy, either as a single agent, combined, or in combination with biological agents. In this report we discuss the different alternative treatment options.


Assuntos
Antimetabólitos Antineoplásicos/efeitos adversos , Fármacos Cardiovasculares/uso terapêutico , Neoplasias Colorretais/tratamento farmacológico , Desoxicitidina/análogos & derivados , Fluoruracila/análogos & derivados , Fluoruracila/efeitos adversos , Cardiopatias/prevenção & controle , Animais , Capecitabina , Desoxicitidina/efeitos adversos , Cardiopatias/induzido quimicamente , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA