1.
Nanotheranostics ; 8(1): 48-63, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38164498

RESUMO

Sweat contains biomarkers for real-time non-invasive health monitoring, but only a few relevant analytes are currently used in clinical practice. In the present study, we investigated whether sweat-derived extracellular vesicles (EVs) can be used as a source of potential protein biomarkers of human and bacterial origin. Methods: By using ExoView platform, electron microscopy, nanoparticle tracking analysis and Western blotting we characterized EVs in the sweat of eight volunteers performing rigorous exercise. We compared the presence of EV markers as well as general protein composition of total sweat, EV-enriched sweat and sweat samples collected in alginate skin patches. Results: We identified 1209 unique human proteins in EV-enriched sweat, of which approximately 20% were present in every individual sample investigated. Sweat derived EVs shared 846 human proteins (70%) with total sweat, while 368 proteins (30%) were captured by medical grade alginate skin patch and such EVs contained the typical exosome marker CD63. The majority of identified proteins are known to be carried by EVs found in other biofluids, mostly urine. Besides human proteins, EV-enriched sweat samples contained 1594 proteins of bacterial origin. Bacterial protein profiles in EV-enriched sweat were characterized by high interindividual variability, that reflected differences in total sweat composition. Alginate-based sweat patch accumulated only 5% proteins of bacterial origin. Conclusion: We showed that sweat-derived EVs provide a rich source of potential biomarkers of human and bacterial origin. Use of commercially available alginate skin patches selectively enrich for human derived material with very little microbial material collected.


Assuntos
Exossomos , Vesículas Extracelulares , Humanos , Suor/metabolismo , Vesículas Extracelulares/metabolismo , Exossomos/metabolismo , Biomarcadores/metabolismo , Alginatos/metabolismo
2.
Opt Lett ; 48(6): 1454-1457, 2023 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-36946951

RESUMO

Biological particles, e.g., viruses, lipid particles, and extracellular vesicles, are attracting significant research interest due to their role in biological processes and potential in practical applications, such as vaccines, diagnostics, and therapies. Their surface and interior contain many different molecules including lipids, nucleic acids, proteins, and carbohydrates. In this Letter, we show how distance-controlled surface-enhanced Raman spectroscopy (SERS) is a promising method to extract essential information from the spatial origin of the signal. This is a highly important parameter in the analysis of these biological particles. The principle of the method is demonstrated by using polystyrene (PS) beads as a biological particle model conjugated with gold nanospheres (AuNSs) functioning as distance-controlled SERS probes via biotin-streptavidin binding. By tuning the size of AuNSs, the Raman signal from the PS beads can be weakened while the signal from the biotin-streptavidin complex is enhanced.


Assuntos
Nanopartículas Metálicas , Nanopartículas , Análise Espectral Raman/métodos , Nanopartículas/química , Estreptavidina/química , Ouro/química , Poliestirenos/química , Nanopartículas Metálicas/química
3.
ACS Sens ; 7(4): 1156-1164, 2022 04 22.
Artigo em Inglês | MEDLINE | ID: mdl-35411764

RESUMO

Wearable sweat sensors are emerging as promising platforms for personalized and real-time tracking of evolving health and fitness parameters. While most wearable sweat sensors focus on tracking biomarker concentration profiles, sweat secretion rate is a key metric with broad implications for assessing hydration, cardiac, and neural conditions. Here we present a wearable microfluidic sensor for continuous sweat rate measurement. A discrete impedimetric sensing scheme relying on interdigitated electrodes within a microfluidic sweat collector allows for precise and selective sweat rate measurement across a broad physiological range. Integration of a manually activated pressure pump to expel sweat from the device prevents sensor saturation and enables continuous sweat rate tracking over hours. By enabling broad range and prolonged sweat rate measurement, this platform tackles a key obstacle to realizing meaningful and actionable sweat sensing for applications in exercise physiology and medicine.


Assuntos
Suor , Dispositivos Eletrônicos Vestíveis , Eletrodos , Microfluídica
4.
Sci Rep ; 11(1): 19594, 2021 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-34599227

RESUMO

Extracellular vesicles (EVs) represent a diverse group of small membrane-encapsulated particles involved in cell-cell communication, but the technologies to characterize EVs are still limited. Hypoxia is a typical condition in solid tumors, and cancer-derived EVs support tumor growth and invasion of tissues by tumor cells. We found that exposure of renal adenocarcinoma cells to hypoxia induced EV secretion and led to notable changes in the EV protein cargo in comparison to normoxia. Proteomics analysis showed overrepresentation of proteins involved in adhesion, such as integrins, in hypoxic EV samples. We further assessed the efficacy of time-gated Raman spectroscopy (TG-RS) and surface-enhanced time-gated Raman spectroscopy (TG-SERS) to characterize EVs. While the conventional continuous wave excitation Raman spectroscopy did not provide a notable signal, prominent signals were obtained with the TG-RS that were further enhanced in the TG-SERS. The Raman signal showed characteristic changes in the amide regions due to alteration in the chemical bonds of the EV proteins. The results illustrate that the TG-RS and the TG-SERS are promising label free technologies to study cellular impact of external stimuli, such as oxygen deficiency, on EV production, as well as differences arising from distinct EV purification protocols.


Assuntos
Carcinoma de Células Renais/fisiopatologia , Vesículas Extracelulares/química , Hipóxia/fisiopatologia , Neoplasias Renais/fisiopatologia , Proteoma , Animais , Linhagem Celular Tumoral , Humanos , Camundongos , Análise Espectral Raman/métodos
5.
ACS Appl Mater Interfaces ; 13(23): 27284-27294, 2021 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-34075741

RESUMO

Printed piezoresistive strain sensors based on stretchable roll-to-roll screen-printed silver electrodes on polydimethylsiloxane substrates and inkjet-deposited single-wall carbon nanotube micropatterns are demonstrated in this work. With the optimization of surface wetting and inkjet printing parameters, well-defined microscopic line patterns of the nanotubes with a sheet resistance of <100 Ω/□ could be deposited between stretchable Ag electrodes on the plasma-treated substrate. The developed stretchable devices are highly sensitive to tensile strain with a gauge factor of up to 400 and a pressure sensitivity of ∼0.09 Pa-1, respond to bending down to a radius of 1.5 mm, and are suitable for mounting on the skin to monitor and resolve various movements of the human body such as cardiac cycle, breathing, and finger flexing. This study indicates that inkjet deposition of nanomaterials can complement well other printing technologies to produce flexible and stretchable devices in a versatile manner.

6.
BMC Genomics ; 22(1): 425, 2021 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-34103018

RESUMO

BACKGROUND: The human sweat is a mixture of secretions from three types of glands: eccrine, apocrine, and sebaceous. Eccrine glands open directly on the skin surface and produce high amounts of water-based fluid in response to heat, emotion, and physical activity, whereas the other glands produce oily fluids and waxy sebum. While most body fluids have been shown to contain nucleic acids, both as ribonucleoprotein complexes and associated with extracellular vesicles (EVs), these have not been investigated in sweat. In this study we aimed to explore and characterize the nucleic acids associated with sweat particles. RESULTS: We used next generation sequencing (NGS) to characterize DNA and RNA in pooled and individual samples of EV-enriched sweat collected from volunteers performing rigorous exercise. In all sequenced samples, we identified DNA originating from all human chromosomes, but only the mitochondrial chromosome was highly represented with 100% coverage. Most of the DNA mapped to unannotated regions of the human genome with some regions highly represented in all samples. Approximately 5 % of the reads were found to map to other genomes: including bacteria (83%), archaea (3%), and virus (13%), identified bacteria species were consistent with those commonly colonizing the human upper body and arm skin. Small RNA-seq from EV-enriched pooled sweat RNA resulted in 74% of the trimmed reads mapped to the human genome, with 29% corresponding to unannotated regions. Over 70% of the RNA reads mapping to an annotated region were tRNA, while misc. RNA (18,5%), protein coding RNA (5%) and miRNA (1,85%) were much less represented. RNA-seq from individually processed EV-enriched sweat collection generally resulted in fewer percentage of reads mapping to the human genome (7-45%), with 50-60% of those reads mapping to unannotated region of the genome and 30-55% being tRNAs, and lower percentage of reads being rRNA, LincRNA, misc. RNA, and protein coding RNA. CONCLUSIONS: Our data demonstrates that sweat, as all other body fluids, contains a wealth of nucleic acids, including DNA and RNA of human and microbial origin, opening a possibility to investigate sweat as a source for biomarkers for specific health parameters.


Assuntos
Vesículas Extracelulares , MicroRNAs , Ácidos Nucleicos , Genoma Humano , Humanos , Suor
7.
ACS Sens ; 5(7): 2010-2017, 2020 07 24.
Artigo em Inglês | MEDLINE | ID: mdl-32469200

RESUMO

Lack of functional integration and high manufacturing costs have been identified as major challenges in commercialization of point-of-care devices. In this study, roll-to-roll (R2R) fabrication process was developed for large-scale manufacturing of disposable microfluidic devices. The integrated, user-friendly device included a plasma separation membrane for simple blood filtration, immobilized antibodies for specific immunodetection, microfluidics for plasma transport and reagent mixing, and a blister for actuation and waste storage. These functionalities were designed to be compatible with R2R processing, which was demonstrated using pilot-scale printing lines producing 60 devices in an hour. The produced sensors enabled rapid (10 min) and sensitive (2 µg/mL) fluorescence-based immunodetection of C-reactive protein from 20 µL of whole blood.


Assuntos
Dispositivos Lab-On-A-Chip , Microfluídica , Anticorpos Imobilizados , Impressão Tridimensional
8.
Sci Adv ; 5(8): eaaw9906, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31453333

RESUMO

Recent technological advancements in wearable sensors have made it easier to detect sweat components, but our limited understanding of sweat restricts its application. A critical bottleneck for temporal and regional sweat analysis is achieving uniform, high-throughput fabrication of sweat sensor components, including microfluidic chip and sensing electrodes. To overcome this challenge, we introduce microfluidic sensing patches mass fabricated via roll-to-roll (R2R) processes. The patch allows sweat capture within a spiral microfluidic for real-time measurement of sweat parameters including [Na+], [K+], [glucose], and sweat rate in exercise and chemically induced sweat. The patch is demonstrated for investigating regional sweat composition, predicting whole-body fluid/electrolyte loss during exercise, uncovering relationships between sweat metrics, and tracking glucose dynamics to explore sweat-to-blood correlations in healthy and diabetic individuals. By enabling a comprehensive sweat analysis, the presented device is a crucial tool for advancing sweat testing beyond the research stage for point-of-care medical and athletic applications.


Assuntos
Glucose/análise , Microfluídica/métodos , Potássio/análise , Sódio/análise , Suor/química , Técnicas Biossensoriais , Diabetes Mellitus/metabolismo , Ensaios de Triagem em Larga Escala , Humanos , Íons/análise , Potássio/química , Sódio/química
9.
ACS Appl Polym Mater ; 1(11): 3165-3173, 2019 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-32954353

RESUMO

The immobilization of biomolecules onto polymeric surfaces employed in the fabrication of biomedical and biosensing devices is generally a challenging issue, as the absence of functional groups in such materials does not allow the use of common surface chemistries. Here we report the use of modified poly-l-lysine (PLL) as an effective method for the selective modification of polymeric materials with biomolecules. Cyclic olefin polymer (COP), Ormostamp, and polydimethylsiloxane (PDMS) surfaces were patterned with modified PLLs displaying either biotin or maleimide functional groups. Different patterning techniques were found to provide faithful microscale pattern formation, including micromolding in capillaries (MIMIC) and a hydrogel-based stamping device with micropores. The surface modification and pattern stability were tested with fluorescence microscopy, contact angle and X-ray photoelectron spectroscopy (XPS), showing an effective functionalization of substrates stable for over 20 days. By exploiting the strong biotin-streptavidin interaction or the thiol-maleimide coupling, DNA and PNA probes were displayed successfully on the surface of the materials, and these probes maintained the capability to specifically recognize complementary DNA sequences from solution. The printing of three different PNA-thiol probe molecules in a microarray fashion allowed selective DNA detection from a mixture of DNA analytes, demonstrating that the modified PLL methodology can potentially be used for multiplexed detection of DNA sequences.

10.
Lab Chip ; 18(11): 1552-1559, 2018 05 29.
Artigo em Inglês | MEDLINE | ID: mdl-29708259

RESUMO

Microfluidic-based integrated molecular diagnostic systems, which are automated, sensitive, specific, user-friendly, robust, rapid, easy-to-use, and portable, can revolutionize future medicine. Current research and development largely relies on polydimethylsiloxane (PDMS) to fabricate microfluidic devices. Since the transition from the proof-of-principle phase to clinical studies requires a vast number of integrated microfluidic devices, there is a need for a high-volume manufacturing method of silicone-based microfluidics. Here we present the first roll-to-roll (R2R) thermal imprinting method to fabricate integrated PDMS-paper microfluidics for molecular diagnostics, which allows production of tens of thousands of replicates in an hour. In order to validate the replicated molecular diagnostic platforms, on-chip amplification of viral ribonucleic acid (RNA) with loop-mediated isothermal amplification (LAMP) was demonstrated. These low-cost, rapid and accurate molecular diagnostic platforms will generate a wide range of applications in preventive personalized medicine, global healthcare, agriculture, food, environment, water monitoring, and global biosecurity.


Assuntos
Dimetilpolisiloxanos/química , Dispositivos Lab-On-A-Chip , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas de Amplificação de Ácido Nucleico/instrumentação , DNA Viral/análise , Desenho de Equipamento , Papel
11.
J Biophotonics ; 11(7): e201700225, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29388744

RESUMO

The ability of noble metal-based nanoparticles (NPs) (Au, Ag) to drastically enhance Raman scattering from molecules placed near metal surface, termed as surface-enhanced Raman scattering (SERS), is widely used for identification of trace amounts of biological materials in biomedical, food safety and security applications. However, conventional NPs synthesized by colloidal chemistry are typically contaminated by nonbiocompatible by-products (surfactants, anions), which can have negative impacts on many live objects under examination (cells, bacteria) and thus decrease the precision of bioidentification. In this article, we explore novel ultrapure laser-synthesized Au-based nanomaterials, including Au NPs and AuSi hybrid nanostructures, as mobile SERS probes in tasks of bacteria detection. We show that these Au-based nanomaterials can efficiently enhance Raman signals from model R6G molecules, while the enhancement factor depends on the content of Au in NP composition. Profiting from the observed enhancement and purity of laser-synthesized nanomaterials, we demonstrate successful identification of 2 types of bacteria (Listeria innocua and Escherichia coli). The obtained results promise less disturbing studies of biological systems based on good biocompatibility of contamination-free laser-synthesized nanomaterials.


Assuntos
Escherichia coli/isolamento & purificação , Ouro/química , Listeria/isolamento & purificação , Nanopartículas Metálicas/química , Nanotecnologia/instrumentação , Análise Espectral Raman , Lasers , Propriedades de Superfície
12.
Opt Express ; 25(21): 25102-25112, 2017 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-29041182

RESUMO

The responses of a polymer ridge waveguide Young interferometer with and without a bilayer of Al2O3/TiO2, fabricated by atomic layer deposition, are studied and compared when applied as an aqueous chemical sensor. The phase shift of the guided mode, as a result of the change in refractive index of the cover medium, is monitored. The results indicate that the over-coating affects the linearity of the sensor response. The effect of concentration on the linearity of the sensor response is investigated by applying different concentrations of water-ethanol solution. Although the performance of the sensor is improved by the additional layers, the study reveals a non-monotonic behavior of the device. We show that it comes mainly from the adsorption of ethanol molecules on the surface of the films. Such an understanding of the platform is crucial for sensing of analytes involving polar molecules.

13.
Sci Rep ; 6: 37192, 2016 11 16.
Artigo em Inglês | MEDLINE | ID: mdl-27849010

RESUMO

Surface-enhanced Raman spectroscopy (SERS) is considered a highly promising technology for different analytical purposes. The applications of SERS are still quite limited due its relatively poor quantitative repeatability and the fact that SERS is very sensitive to oxidation, which is a challenge especially with silver based SERS substrates. Here, the link between these phenomena is investigated by exposing silver SERS substrates to ambient laboratory air. We show that SERS intensity decreases exponentially after the exposure, which consequently leads to an increasing standard deviation (σ) in intensity. Within a five-hour measurement window, the SERS intensity already drops by 60%, while σ triples from 7% to 21%. The SERS results are supplemented by elemental analysis, which shows that oxidation and atmospheric carbon contamination coincide with the rapid SERS intensity decrease. The results emphasize how sensitive SERS is towards atmospheric contamination and how it can also reduce the measurement repeatability - even if the substrates are exposed to air just for a very short period of time.

14.
Opt Express ; 24(10): 10275-85, 2016 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-27409852

RESUMO

We demonstrate a polymer slot waveguide Young interferometer coated with a bilayer of Al2O3/TiO2. The approach enables relaxed dimensions of the polymer waveguide which simplifies the fabrication of the structure with a resolution of 50 nm. The layers were coated by an atomic layer deposition technique. The feasibility of the device was investigated by exploiting the interferometric structure as a bulk refractive index sensor operating at 975 nm wavelength for detection of an ethanol-water solution. A refractive index change of 1 × 10-6 RIU with a sensing length of only 800 µm was detected. The approach confirms the possibility of realizing a low cost device with a small footprint and enhanced sensitivity by employing the TiO2 rails in the sides of the slot waveguide.

15.
Opt Express ; 24(3): 2527-41, 2016 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-26906827

RESUMO

Flexible photonic integrated circuit technology is an emerging field expanding the usage possibilities of photonics, particularly in sensor applications, by enabling the realization of conformable devices and introduction of new alternative production methods. Here, we demonstrate that disposable polymeric photonic integrated circuit devices can be produced in lengths of hundreds of meters by ultra-high volume roll-to-roll methods on a flexible carrier. Attenuation properties of hundreds of individual devices were measured confirming that waveguides with good and repeatable performance were fabricated. We also demonstrate the applicability of the devices for the evanescent wave sensing of ambient refractive index. The production of integrated photonic devices using ultra-high volume fabrication, in a similar manner as paper is produced, may inherently expand methods of manufacturing low-cost disposable photonic integrated circuits for a wide range of sensor applications.

16.
Appl Opt ; 54(15): 4771-80, 2015 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-26192514

RESUMO

Polymer-based integrated Young interferometer (YI) sensor chips have proven to be sensitive and have potential to be mass-manufactured. The sensing method is however, disturbed by the mechanical drifts, thus requiring well stabilized and isolated measurement setups that limit its applicability to low-cost readers for rapid diagnostics. In this paper we derive a method for the compensation of mechanical drift by using a multichannel integrated YI chip having two reference channels. The compensation method was demonstrated by quantitative measurements with a three-channel integrated polymeric YI sensor chip using an undisturbed and a mechanically disturbed setup. By applying the compensation method, the intrinsic drift of the undisturbed setup was reduced up to 84%. With the mechanically disturbed setup, the sample-induced phase-change responses were separated up to a 161 times larger disturbed signal.


Assuntos
Interferometria/métodos , Polímeros/química , Processamento de Sinais Assistido por Computador , Desenho de Equipamento , Glucose/química , Processamento de Imagem Assistida por Computador/métodos , Sistemas Automatizados de Assistência Junto ao Leito , Refratometria , Estresse Mecânico , Água/química
17.
Opt Express ; 22(6): 7229-37, 2014 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-24664071

RESUMO

A refractive index sensor based on slot waveguide Young interferometer was developed in this work. The interferometer was fabricated on a polymer platform and operates at a visible wavelength of 633 nm. The phase shift of the interference pattern was measured with various concentrations of glucose-water solutions, utilizing both TE and TM polarization states. The sensor was experimentally observed to detect a refractive index difference of 6.4 × 10(-6) RIU. Furthermore, the slot Young interferometer was found to compensate for temperature variations. The results of this work demonstrate that high performance sensing capability can be obtained with a polymeric slot Young interferometer, which can be fabricated by a simple molding process.

18.
Opt Lett ; 37(21): 4449-51, 2012 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-23114325

RESUMO

Polymeric slot waveguide structure, which pushes the mode field toward the surrounding media, was designed and characterized. The slot waveguide was fabricated by using nanoimprint lithography, and the operation of the slot was demonstrated at 633 nm wavelength with an integrated Young interferometer. The experimental result shows that the nanolithography method provides possibilities to fabricate disposable slot waveguide sensors.

19.
Opt Express ; 20(18): 20309-17, 2012 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-23037082

RESUMO

An evanescent field sensor utilizing layered polymeric-inorganic composite waveguide configuration was developed in this work. The composite waveguide structure consists of a UV-imprint patterned polymer inverted rib waveguide with a Ta2O5 thin film sputter-deposited on top of the low refractive index polymer layers. The results suggest that the polymer based sensor can achieve a detection limit of 3 × 10(-7) RIU for refractive index sensing and corresponding limit of about 100 fg/mm2 for molecular adsorption detection. Besides enhancing the sensitivity significantly, the inorganic coating on the polymer layer was found to block water absorption effectively into the waveguide resulting in a stabilized sensor operation. The ability to use the developed sensor in specific molecular detection was confirmed by investigating antibody - antigen binding reactions. The results of this work demonstrate that high performance sensing capability can be obtained with the developed composite waveguide sensor.


Assuntos
Técnicas Biossensoriais/instrumentação , Imunoensaio/instrumentação , Compostos Inorgânicos/química , Impressão Molecular/instrumentação , Impressão Molecular/métodos , Polímeros/química , Refratometria/instrumentação , Ressonância de Plasmônio de Superfície/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento
20.
Appl Opt ; 51(12): 1886-93, 2012 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-22534893

RESUMO

A polymer based dual-slab waveguide Young's interferometer was demonstrated for biochemical sensing. Evanescent field is utilized for probing the binding events of biomolecules on the waveguide surface. Refractive index sensing in analyte and protein adsorption on the sensing surface were investigated with glucose de-ionized water solution and bovine serum albumin, immunoglobulin G solutions in phosphate buffered saline buffer. A detection limit of 10(-5) RIU and 4 pg/mm(2) was achieved for homogeneous and surface sensing, respectively. Also, the influence of water absorption inside the polymeric device on the measurement stability was evaluated. The results indicate that the waveguide polymer sensor fabricated with the spin coating technique can achieve a satisfactory sensitivity for homogeneous refractive index sensing and, as well, for monitoring molecular binding events on the surface.


Assuntos
Bioquímica/métodos , Interferometria/métodos , Polímeros/química , Absorção , Adsorção , Animais , Técnicas Biossensoriais , Bovinos , Glucose/química , Modelos Estatísticos , Modelos Teóricos , Refratometria , Soroalbumina Bovina/química , Água/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...