1.
Kyobu Geka ; 73(9): 667-670, 2020 Sep.
Artigo em Japonês | MEDLINE | ID: mdl-32879269

RESUMO

This is a 3-case report of successful descending thoracic and thoracoabdominal aortic surgery by preserving the spinal perfusion artery (SPA) identified preoperatively. In Case 1, an 85-year-old woman, computed tomography (CT) showed Crawford type Ⅴ thoracoabdominal aortic aneurysm (TAAA:60 mm) and a SPA originated from L2. In Case 2, a 76-year-old man, CT revealed type Ⅳ TAAA( 58 mm) and a SPA originated from Th11. In Case 3, a 74-year-old man, CT detected an infectious pseudoaneurysm(44 mm) in the descending thoracic aorta with 2 SPAs originating from Th10 and L2. The ranges of graft replacement were Th7-Th12, Th12-L4, and Th8-Th10, respectively, while preserving all SPAs. All patients recovered well without postoperative neurological deficits. Although the protective effect of the SPA preservation against the spinal cord ischemia is still controversial, preoperative identification of the SPA was useful for planning a surgical strategy for descending thoracic and thoracoabdominal aortic repair surgery.


Assuntos
Aneurisma da Aorta Abdominal , Aneurisma da Aorta Torácica , Isquemia do Cordão Espinal , Idoso , Idoso de 80 Anos ou mais , Artérias , Feminino , Humanos , Masculino , Perfusão , Medula Espinal , Tomografia Computadorizada por Raios X
2.
Kyobu Geka ; 72(13): 1085-1088, 2019 Dec.
Artigo em Japonês | MEDLINE | ID: mdl-31879385

RESUMO

This is a 2-case report of successful aortic repair surgery for the retrosternal giant aortic aneurysm. Our surgical strategy is "deep hypothermia and left ventricular( LV) unloading under cardiopulmonary bypass before approaching to the aortic aneurysm" in case of possible catastrophic bleeding. Case 1, a 64-year-old woman, had a retrosternal pseudoaneurysm (80 mm) at the distal anastomosis of a Dacron graft used to replace the ascending aorta 7 years before. An LV vent tube was cannulated via the right upper pulmonary vein through an inferior T-shaped ministernotomy. Case 2, an 86-year-old woman, had a retrosternal chronic aortic dissecting aneurysm (66 mm). An LV vent cannula was inserted via the LV apex through a left minithoracotomy. Arch replacement and ascending aorta replacement were performed in Case 1 and 2, respectively, without cardiac, neurological, or any other complications. This strategy is safe and useful in a case with complex aortic disease.


Assuntos
Falso Aneurisma , Aneurisma Aórtico , Dissecção Aórtica , Idoso de 80 Anos ou mais , Aorta , Aorta Torácica , Feminino , Humanos , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS