Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Clin Med ; 11(11)2022 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-35683559

RESUMO

Gluteus maximus flap transfer (GMT) is a surgical technique used to improve gait kinematics and kinetics, as well as to reduce and ameliorate the functional outcome in patients with hip abductor deficiency following total hip arthroplasty (THA). The purpose of this observational study was to evaluate the gait pre- and postoperatively and examine whether GMT increases the abduction moment. Materials and Methods: A gait analysis based on reflective markers and force plates was performed in 15 patients who underwent GMT and were examined using an optical tracking system before and at a minimum of 13 months after the operation. The median follow-up time was 24 (13−60) months. The primary outcome was hip abduction moment (Nm/kg) during gait. The control group consisted of 15 female subjects without any gait pathology. Results: The mean adduction moment was significantly higher compared with controls before the operation (p = 0.02), but this did not apply to the abduction moment (p = 0.60). At the group level, the abduction moment did not improve postoperatively (p = 0.30). Only six of fifteen patients slightly improved their hip abduction moment postoperatively. However, speed (0.74 to 0.80 m/s) and cadence (94 to 105 steps/min) were improved (p < 0.03). Discussion: The results of this study showed no improvement in the hip abduction moment after GMT surgery. In our experience, abduction deficiency following primary THA is still a difficult and unsolved problem.

2.
Acta Orthop ; 91(6): 682-686, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32619155

RESUMO

Background and purpose - The use of trabecular metal cups in primary total hip arthroplasty (THA) is increasing, despite the survival of Continuum cups being slightly inferior compared with other uncemented cups in registries. This difference is mainly explained by a higher rate of dislocation revisions. Cup malpositioning is a risk factor for dislocation and, being made of a highly porous material, Continuum cups might be more difficult to position. We evaluated whether Continuum cups had worse cup positioning compared with other uncemented cups. Patients and methods - Based on power calculation, 150 Continuum cups from 1 center were propensity score matched with 150 other uncemented cups from 4 centers. All patients had an uncemented stem, femoral head size of 32 mm or 36 mm, and BMI between 19 and 35. All operations were done for primary osteoarthrosis through a posterior approach. Patients were matched using age, sex, and BMI. Cup positioning was measured from anteroposterior pelvic radiograph using the Martell Hip Analysis Suite software. Results - There was no clinically relevant difference in mean inclination angle between the study group and the control group (43° [95% CI 41-44] and 43° [CI 42-45], respectively). The study group had a larger mean anteversion angle compared with the control group, 19° (CI 18-20) and 17° (CI 15-18) respectively. Interpretation - Continuum cups had a greater anteversion compared with the other uncemented cups. However, the median anteversion was acceptable in both groups and this difference does not explain the larger dislocation rate in the Continuum cups observed in earlier studies.


Assuntos
Artroplastia de Quadril , Anteversão Óssea , Prótese de Quadril/efeitos adversos , Metais/uso terapêutico , Complicações Pós-Operatórias , Desenho de Prótese , Titânio/uso terapêutico , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/métodos , Anteversão Óssea/diagnóstico por imagem , Anteversão Óssea/etiologia , Anteversão Óssea/prevenção & controle , Análise de Falha de Equipamento , Feminino , Finlândia/epidemiologia , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Desenho de Prótese/efeitos adversos , Desenho de Prótese/métodos , Falha de Prótese/etiologia , Ajuste de Prótese/métodos , Radiografia/métodos , Suécia/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...