Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Mol Diagn ; 25(6): 331-341, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36870603

RESUMO

High-throughput sequencing of the T-cell receptor beta (TRB) and gamma (TRG) loci is increasingly utilized due to its high sensitivity, specificity, and versatility in the diagnosis of various T-cell malignancies. Application of these technologies for tracking disease burden can be valuable in detecting recurrence, determining response to therapy, guiding future management of patients, and establishing endpoints for clinical trials. In this study, the performance of the commercially available LymphoTrack high-throughput sequencing assay was assessed for determining residual disease burden in patients with various T-cell malignancies. A custom bioinformatics pipeline and database was also developed to facilitate minimal/measurable residual disease analysis and clinical reporting. This assay demonstrated excellent test performance characteristics, achieving a sensitivity of 1 of 100,000 T-cell equivalents for the DNA inputs evaluated and high concordance with orthogonal testing methods. This assay was further utilized to correlate disease burden in several patients, demonstrating its potential utility for monitoring patients with T-cell malignancies.


Assuntos
Linfoma , Leucemia-Linfoma Linfoblástico de Células Precursoras , Humanos , Leucemia-Linfoma Linfoblástico de Células Precursoras/genética , Linfócitos T , Receptores de Antígenos de Linfócitos T/genética , Sequenciamento de Nucleotídeos em Larga Escala/métodos , Neoplasia Residual/diagnóstico , Neoplasia Residual/genética
2.
J Mol Diagn ; 23(7): 805-815, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33892183

RESUMO

Assessment of T-cell receptor γ gene (TRG) rearrangements is an importants consideration in the diagnostic workup of lymphoproliferative diseases. Although fragment analysis by PCR and capillary electrophoresis (CE) is the current standard of such assessment in clinical molecular diagnostic laboratories, it does not provide sequence information and is only semi-quantitative. Next-generation sequencing (NGS)-based assays are an attractive alternative to the conventional fragment size-based methods, given that they generate results with specific clonotype sequence information and allow for more accurate quantitation. The present study evaluated various test parameters and performance characteristics of a commercially available NGS-based TRG gene-rearrangement assay by testing 101 clinical samples previously characterized by fragment analysis. The NGS TRG assay showed an overall accuracy of 83% and an analytical specificity of 100%. The concordance rates were 88% to 95% in the Vγ1-8, Vγ10, and Vγ11 gene families, but lower in the Vγ9 gene family. This difference was mostly attributed to the incomplete polyclonal symmetry resulting from the two-tube CE assay versus the one-tube design of the NGS assay. The NGS assay also demonstrated strengths in distinguishing clonotypes of the same fragment size. This clinical validation demonstrated robust performance of the NGS-based TRG assay and identified potential pitfalls associated with CE assay design that are important for understanding the observed discrepancies with the CE-based assay.


Assuntos
Eletroforese Capilar/métodos , Rearranjo Gênico da Cadeia gama dos Receptores de Antígenos dos Linfócitos T , Genes Codificadores da Cadeia gama de Receptores de Linfócitos T , Sequenciamento de Nucleotídeos em Larga Escala/métodos , Transtornos Linfoproliferativos/diagnóstico , Transtornos Linfoproliferativos/genética , Técnicas de Diagnóstico Molecular/métodos , DNA/sangue , DNA/genética , Confiabilidade dos Dados , Humanos , Limite de Detecção , Transtornos Linfoproliferativos/sangue , Reação em Cadeia da Polimerase/métodos
3.
J Pathol Inform ; 9: 24, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30034922

RESUMO

BACKGROUND: Implementing a laboratory-developed test sometimes requires incorporating an unconventional device into the laboratory information system (LIS) and customizing an interface to reduce transcription error and improve turnaround time. Such a custom interface is a necessity for complicated high-volume tests such as 25-OH Vitamin D by liquid chromatography-tandem mass spectrometry (LC-MS/MS) when there is no vendor-or LIS-supplied interface available. Here, we describe our work and experience interfacing a API 5000 LC-MS/MS instrument with our newly implemented LIS, Epic Beaker, using a combination of in-house scripting software and a middleware vendor, Data Innovations. MATERIALS AND METHODS: For input interfacing, custom scripting software was developed to transcribe batched order lists generated by Epic into files usable by the instrument software, Analyst®. For output interfacing, results from the LC-MS/MS system were fed to a unidirectional instrument driver made by Data Innovations and selected data were transferred to the LIS. RESULTS: Creation and validation of a new driver by Data Innovations took approximately 6 months. The interface was adopted for 25-OH Vitamin D and testosterone testing during periods of increasing test volume (4.5-fold over 8 years and 1.25-fold over 5 years). The amount of time spent reporting 25-OH Vitamin D results decreased 82% per order resulting in a savings of 1370 technician work hours and the amount of time spent reporting testosterone results decreased 75% per order resulting in a savings of 400 technician work hours. CONCLUSIONS: A mixed model using custom scripting and curated commercial middleware serve as a durable interface solution for laboratory instrumentation such as an LC-MS/MS and are flexible to future changes in instrument software, networking protocols, and the scope of LISs and work area managers.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...