Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Rev Lett ; 124(10): 104801, 2020 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-32216389

RESUMO

Wakefield based accelerators capable of accelerating gradients 2 orders of magnitude higher than present accelerators offer a path to compact high energy physics instruments and light sources. However, for high gradient accelerators, beam instabilities driven by commensurately high transverse wakefields limit beam quality. Previously, it has been theoretically shown that transverse wakefields can be reduced by elliptically shaping the transverse sizes of beams in dielectric structures with planar symmetry. Here, we report experimental measurements that demonstrate reduced transverse wakefields for elliptical beams in planar symmetric structures which are consistent with theoretical models. These results may enable the design of gigavolt-per-meter gradient wakefield based accelerators that produce and stably accelerate high quality beams.

2.
Phys Rev Lett ; 123(13): 134801, 2019 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-31697514

RESUMO

An intense, subpicosecond, relativistic electron beam traversing a dielectric-lined waveguide generates very large amplitude electric fields at terahertz (THz) frequencies through the wakefield mechanism. In recent work employing this technique to accelerate charged particles, the generation of high-power, narrow-band THz radiation was demonstrated. The radiated waves contain fields with measured amplitude exceeding 2 GV/m, orders of magnitude greater than those available by other THz generation techniques at a narrow bandwidth. For fields approaching the GV/m level, a strong damping has been observed in SiO_{2}. This wave attenuation with an onset near 850 MV/m is consistent with changes to the conductivity of the dielectric lining and is characterized by a distinctive latching mechanism that is reversible on longer timescales. We describe the detailed measurements that serve to clarify the underlying physical mechanisms leading to strong field-induced damping of THz radiation (hω=1.59 meV, f=0.38 THz) in SiO_{2}, a bulk, wide band-gap (8.9 eV) dielectric.

3.
Phys Rev Lett ; 120(16): 164801, 2018 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-29756951

RESUMO

Photonic structures operating in the terahertz (THz) spectral region enable the essential characteristics of confinement, modal control, and electric field shielding for very high gradient accelerators based on wakefields in dielectrics. We report here an experimental investigation of THz wakefield modes in a three-dimensional photonic woodpile structure. Selective control in exciting or suppressing of wakefield modes with a nonzero transverse wave vector is demonstrated by using drive beams of varying transverse ellipticity. Additionally, we show that the wakefield spectrum is insensitive to the offset position of strongly elliptical beams. These results are consistent with analytic theory and three-dimensional simulations and illustrate a key advantage of wakefield systems with Cartesian symmetry: the suppression of transverse wakes by elliptical beams.

4.
Nat Commun ; 7: 12763, 2016 09 14.
Artigo em Inglês | MEDLINE | ID: mdl-27624348

RESUMO

There is urgent need to develop new acceleration techniques capable of exceeding gigaelectron-volt-per-metre (GeV m(-1)) gradients in order to enable future generations of both light sources and high-energy physics experiments. To address this need, short wavelength accelerators based on wakefields, where an intense relativistic electron beam radiates the demanded fields directly into the accelerator structure or medium, are currently under intense investigation. One such wakefield based accelerator, the dielectric wakefield accelerator, uses a dielectric lined-waveguide to support a wakefield used for acceleration. Here we show gradients of 1.347±0.020 GeV m(-1) using a dielectric wakefield accelerator of 15 cm length, with sub-millimetre transverse aperture, by measuring changes of the kinetic state of relativistic electron beams. We follow this measurement by demonstrating accelerating gradients of 320±17 MeV m(-1). Both measurements improve on previous measurements by and order of magnitude and show promise for dielectric wakefield accelerators as sources of high-energy electrons.

5.
J Exp Biol ; 210(Pt 23): 4159-68, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18025015

RESUMO

This study provides the first in vivo measures of the passive length-tension properties of relaxed human muscle fascicles and their tendons. A new method was used to derive passive length-tension properties of human gastrocnemius muscle-tendon units from measures of ankle stiffness obtained at a range of knee angles. Passive length-tension curves of the muscle-tendon unit were then combined with ultrasonographic measures of muscle fascicle length and pennation to determine passive length-tension curves of the muscle fascicles and tendons. Mean slack lengths of the fascicles, tendons and whole muscle-tendon units were 3.3+/-0.5 cm, 39.5+/-1.6 cm and 42.3+/-1.5 cm, respectively (means +/- s.d., N=6). On average, the muscle-tendon units were slack (i.e. their passive tension was zero) over the shortest 2.3+/-1.2 cm of their range. With combined changes of knee and ankle angles, the maximal increase in length of the gastrocnemius muscle-tendon unit above slack length was 6.7+/-1.9 cm, of which 52.4+/-11.7% was due to elongation of the tendon. Muscle fascicles and tendons underwent strains of 86.4+/-26.8% and 9.2+/-4.1%, respectively, across the physiological range of lengths. We conclude that the relaxed human gastrocnemius muscle-tendon unit falls slack over about one-quarter of its in vivo length and that muscle fascicle strains are much greater than tendon strains. Nonetheless, because the tendons are much longer than the muscle fascicles, tendons contribute more than half of the total compliance of the muscle-tendon unit.


Assuntos
Músculo Esquelético/fisiologia , Tendões/fisiologia , Adulto , Antropometria , Fenômenos Biomecânicos , Peso Corporal , Feminino , Humanos , Perna (Membro)/fisiologia , Masculino , Pessoa de Meia-Idade , Modelos Biológicos , Tono Muscular/fisiologia , Músculo Esquelético/diagnóstico por imagem , Ultrassonografia
6.
J Biomech ; 38(6): 1333-41, 2005 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15863118

RESUMO

The study of muscle growth and muscle length adaptations requires measurement of passive length-tension properties of individual muscles, but until now such measurements have only been made in animal muscles. We describe a new method for measuring passive length-tension properties of human gastrocnemius muscles in vivo. Passive ankle torque and ankle angle data were obtained as the ankle was rotated through its full range with the knee in a range of positions. To extract gastrocnemius passive length-tension curves from passive torque-angle data it was assumed that passive ankle torque was the sum of torque due to structures which crossed only the ankle joint (this torque was a 6-parameter function of ankle joint angle) and a torque due to the gastrocnemius muscle (a 3-parameter function of knee and ankle angle). Parameter values were estimated with non-linear regression and used to reconstruct passive length-tension curves of the gastrocnemius. The reliability of the method was examined in 11 subjects by comparing three sets of measurements: two on the same day and the other at least a week later. Length-tension curves were reproducible: the average root mean square error was 5.1+/-1.1 N for pairs of measurements taken within a day and 7.3+/-1.2 N for pairs of measurements taken at least a week apart (about 3% and 6% of maximal passive tension, respectively). Length-tension curves were sensitive to mis-specification of moment arms, but changes in length-tension curves were not. The new method enables reliable measurement of passive length-tension properties of human gastrocnemius in vivo, and is likely to be useful for investigation of changes in length-tension curves over time.


Assuntos
Fenômenos Biomecânicos/métodos , Modelos Biológicos , Músculo Esquelético/fisiologia , Exame Físico/métodos , Adulto , Articulação do Tornozelo/fisiologia , Fenômenos Biomecânicos/instrumentação , Simulação por Computador , Elasticidade , Feminino , Humanos , Articulação do Joelho/fisiologia , Masculino , Exame Físico/instrumentação , Amplitude de Movimento Articular/fisiologia , Estresse Mecânico , Torque
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...