Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Am J Perinatol ; 36(7): 742-750, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30372770

RESUMO

PURPOSE: We hypothesized that surgical energy could be used to create hysterotomies in open fetal surgery. STUDY DESIGN: Initial studies compared the LigaSure Impact and Harmonic ACE + 7 Shears in the efficiency of hysterotomy and thermal damage. Pregnant ewes at an estimated gestational age (EGA) of 116 to 120 days (term = 145; n = 7) underwent hysterotomy using either device. Hysterotomy edges were resected, and thermal injury extent was determined by histopathological assessment. Upon determining a superior device, subsequent studies compared this to the AutoSuture Premium Poly CS*-57 Stapler in uterine healing. Pregnant ewes (n = 6) at an EGA of 87 to 93 days underwent 6-cm hysterotomy in each gravid horn with either the stapler (n = 5) or Harmonic (n = 5) followed by closure and animal recovery. After 37 to 42 days, uterine healing was assessed by evaluating tensile strength and histopathology. RESULTS: Thermal damage was more extensive with the LigaSure (n = 11 hysterotomies) than with the Harmonic (n = 11; 5.6 ± 1 vs. 3.1 ± 0.6 mm; p < 0.0001);therefore, the Harmonic was selected for healing studies. Gross scar appearance and tensile strength were the same between the Harmonic and stapler. The stapler caused more fibrosis (4/7 samples with "moderate" fibrosis vs. 0/8 with the Harmonic; p = 0.02). CONCLUSION: The Harmonic ACE + 7 caused less thermal injury than the LigaSure Impact and performed similar to the CS*-57 Stapler in uterine healing with continued gestation.


Assuntos
Eletrocirurgia/instrumentação , Terapias Fetais/métodos , Feto/cirurgia , Histerotomia/métodos , Grampeamento Cirúrgico , Animais , Cicatriz/etiologia , Desenho de Equipamento , Feminino , Histerotomia/efeitos adversos , Histerotomia/instrumentação , Modelos Animais , Ovinos , Útero/patologia
2.
J Pediatr Surg ; 53(10): 1896-1903, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29960740

RESUMO

PURPOSE: An artificial placenta (AP) utilizing extracorporeal life support (ECLS) could avoid the harm of mechanical ventilation (MV) while allowing the lungs to develop. METHODS: AP lambs (n = 5) were delivered at 118 days gestational age (GA; term = 145 days) and placed on venovenous ECLS (VV-ECLS) with jugular drainage and umbilical vein reinfusion. Lungs remained fluid-filled. After 10 days, lambs were ventilated. MV control lambs were delivered at 118 ("early MV"; n = 5) or 128 days ("late MV"; n = 5), and ventilated. Compliance and oxygenation index (OI) were calculated. After sacrifice, lungs were procured and H&E-stained slides scored for lung injury. Slides were also immunostained for PDGFR-α and α-actin; alveolar development was quantified by the area fraction of alveolar septal tips staining double-positive for both markers. RESULTS: Compliance of AP lambs was 2.79 ±â€¯0.81 Cdyn compared to 0.83 ±â€¯0.19 and 3.04 ±â€¯0.99 for early and late MV, respectively. OI in AP lambs was lower than early MV lambs (6.20 ±â€¯2.10 vs. 36.8 ±â€¯16.8) and lung injury lower as well (1.8 ±â€¯1.6 vs. 6.0 ±â€¯1.2). Double-positive area fractions were higher in AP lambs (0.012 ±â€¯0.003) than early (0.003 ±â€¯0.0005) and late (0.004 ±â€¯0.002) MV controls. CONCLUSIONS: Lung development continues and lungs are protected from injury during AP support relative to mechanical ventilation. LEVEL OF EVIDENCE: n/a (basic/translational science).


Assuntos
Órgãos Artificiais , Oxigenação por Membrana Extracorpórea , Pulmão/crescimento & desenvolvimento , Nascimento Prematuro/terapia , Animais , Animais Recém-Nascidos , Modelos Animais de Doenças , Feminino , Idade Gestacional , Pulmão/fisiologia , Placenta/fisiologia , Gravidez , Ovinos
3.
ASAIO J ; 63(2): 223-228, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-27861431

RESUMO

Lung disease in children often results in pulmonary hypertension and right heart failure. The availability of a pediatric artificial lung (PAL) would open new approaches to the management of these conditions by bridging to recovery in acute disease or transplantation in chronic disease. This study investigates the efficacy of a novel PAL in alleviating an animal model of pulmonary hypertension and increased right ventricle afterload. Five juvenile lambs (20-30 kg) underwent PAL implantation in a pulmonary artery to left atrium configuration. Induction of disease involved temporary, reversible occlusion of the right main pulmonary artery. Hemodynamics, pulmonary vascular input impedance, and right ventricle efficiency were measured under 1) baseline, 2) disease, and 3) disease + PAL conditions. The disease model altered hemodynamics variables in a manner consistent with pulmonary hypertension. Subsequent PAL attachment improved pulmonary artery pressure (p = 0.018), cardiac output (p = 0.050), pulmonary vascular input impedance (Z.0 p = 0.028; Z.1 p = 0.058), and right ventricle efficiency (p = 0.001). The PAL averaged resistance of 2.3 ± 0.8 mm Hg/L/min and blood flow of 1.3 ± 0.6 L/min. This novel low-resistance PAL can alleviate pulmonary hypertension in an acute animal model and demonstrates potential for use as a bridge to lung recovery or transplantation in pediatric patients with significant pulmonary hypertension refractory to medical therapies.


Assuntos
Órgãos Artificiais , Modelos Animais de Doenças , Ventrículos do Coração/fisiopatologia , Hipertensão Pulmonar/terapia , Pulmão , Animais , Criança , Hemodinâmica , Humanos , Hipertensão Pulmonar/fisiopatologia , Pulmão/fisiopatologia , Masculino , Artéria Pulmonar , Ovinos
4.
ASAIO J ; 63(2): 216-222, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-27832003

RESUMO

A pediatric artificial lung (PAL) is under development as a bridge to transplantation or lung remodeling for children with end-stage lung failure (ESLF). To evaluate the efficiency of a PAL, a disease model mimicking the physiologic derangements of pediatric ESLF is needed. Our previous right pulmonary artery (rPA) ligation model (rPA-LM) achieved that goal, but caused immediate mortality in nearly half of the animals. In this study, we evaluated a new technique of gradual postoperative right pulmonary artery occlusion using a Rummel tourniquet (rPA-RT) in seven (25-40 kg) sheep. This technique created a stable model of ESLF pathophysiology, characterized by high alveolar dead space (58.0% ± 3.8%), pulmonary hypertension (38.4 ± 2.2 mm Hg), tachypnea (79 ± 20 breaths per minute), and intermittent supplemental oxygen requirement. This improvement to our technique provides the necessary physiologic derangements for testing a PAL, whereas avoiding the problem of high immediate perioperative mortality.


Assuntos
Órgãos Artificiais , Modelos Animais de Doenças , Pulmão , Insuficiência Respiratória/terapia , Animais , Criança , Humanos , Ligadura , Ovinos
5.
ASAIO J ; 62(1): 110-3, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26461241

RESUMO

End-stage lung disease (ESLD) causes progressive hypercapnia and dyspnea and impacts quality of life. Many extracorporeal support (ECS) configurations for CO2 removal resolve symptoms but limit ambulation. An ovine model of pumpless ECS using subclavian vessels was developed to allow for ambulatory support. Vascular grafts were anastomosed to the left subclavian vessels in four healthy sheep. A low-resistance membrane oxygenator was attached in an arteriovenous (AV) configuration. Device function was evaluated in each animal while awake and spontaneously breathing and while mechanically ventilated with hypercapnia induced. Sweep gas (FiO2 = 0.21) to the device was increased from 0 to 15 L/min, and arterial and postdevice blood gases, as well as postdevice air, were sampled. Hemodynamics remained stable with average AV shunt flows of 1.34 ± 0.14 L/min. In awake animals, CO2 removal was 3.4 ± 1.0 ml/kg/min at maximum sweep gas flow. Respiratory rate decreased from 60 ± 25 at baseline to 30 ± 11 breaths per minute. In animals with induced hypercapnia, PaCO2 increased to 73.9 ± 15.1. At maximum sweep gas flow, CO2 removal was 3.4 ± 0.4 ml/kg/min and PaCO2 decreased to 49.1 ± 6.7 mm Hg. Subclavian AV access is effective in lowering PaCO2 and respiratory rate and is potentially an effective ambulatory destination therapy for ESLD patients.


Assuntos
Dióxido de Carbono/sangue , Circulação Extracorpórea/instrumentação , Pneumopatias/terapia , Insuficiência Respiratória/terapia , Veia Subclávia , Ar , Animais , Derivação Arteriovenosa Cirúrgica , Dióxido de Carbono/metabolismo , Oxigenação por Membrana Extracorpórea , Pneumopatias/sangue , Pneumopatias/metabolismo , Oxigenadores de Membrana , Troca Gasosa Pulmonar , Respiração Artificial/instrumentação , Respiração Artificial/métodos , Insuficiência Respiratória/sangue , Insuficiência Respiratória/metabolismo
6.
ASAIO J ; 61(4): 453-8, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25905495

RESUMO

An implantable pediatric artificial lung (PAL) may serve as a bridge to lung transplantation for children with end-stage lung failure (ESLF); however, an animal model of pediatric lung failure is needed to evaluate the efficacy of PAL before it can enter clinical trials. The objective of this study was to assess ligation of the right pulmonary artery (rPA) as a model for pediatric ESLF. Seven lambs weighing 20-30 kg underwent rPA ligation and were recovered and monitored for up to 4 days. Intraoperatively, rPA ligation significantly increased physiologic dead space fraction (Vd/Vt; baseline = 48.6 ± 5.7%, rPA ligation = 60.1 ± 5.2%, p = 0.012), mean pulmonary arterial pressure (mPPA; baseline = 17.4 ± 2.2 mm Hg, rPA ligation = 28.5 ± 5.2 mm Hg, p < 0.001), and arterial partial pressure of carbon dioxide (baseline = 40.4 ± 9.3 mm Hg, rPA ligation = 57.3 ± 12.7 mm Hg, p = 0.026). Of the seven lambs, three were unable to be weaned from mechanical ventilation postoperatively, three were successfully weaned but suffered cardiorespiratory failure within 4 days, and one survived all 4 days. All four animals that were successfully weaned from mechanical ventilation had persistent pulmonary hypertension (mPPA = 28.6 ± 2.2 mm Hg) and remained tachypneic (respiratory rate = 63 ± 21 min). Three of the four recovered lambs required supplemental oxygen. We conclude that rPA ligation creates the physiologic derangements commonly seen in pediatric ESLF and may be suitable for testing and implanting a PAL.


Assuntos
Órgãos Artificiais , Modelos Animais de Doenças , Pulmão , Artéria Pulmonar/lesões , Animais , Hipertensão Pulmonar/etiologia , Hipertensão Pulmonar/cirurgia , Ligadura , Respiração Artificial/instrumentação , Insuficiência Respiratória/etiologia , Insuficiência Respiratória/cirurgia , Carneiro Doméstico , Ventiladores Mecânicos
7.
ASAIO J ; 61(4): 474-9, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25851315

RESUMO

Donation from uncontrolled circulatory determination of death donors (uDCD) is impractical in United States because of the time needed to organize procurement before irreversible organ damage. Salvaging organs after prolonged warm ischemic time (WIT) may address this limitation. We evaluated the combination of extracorporeal support (ECS) and thrombolytics in a porcine uDCD renal transplant model. Nonanticoagulated uDCD sustained 60 min of WIT, and two groups were studied. Rapid recovery (RR)-uDCD renal grafts procured using the standard quick topical cooling and renal flush, and ECS-assisted donation (E-uDCD), 4 hr ECS plus thrombolytics for in situ perfusion before procurement. All kidneys were flushed and cold stored, followed by transplantation into healthy nephrectomized recipients without immunosuppression. Delayed graft function (DGF) was defined as creatinine more than 5.0 mg/dl on any postoperative day. Twelve kidneys in E-uDCD and 6 in RR-uDCD group were transplanted. All 12 E-uDCD recipients had urine production and adequate function in the first 48 hr, but two grafts (16.7%) had DGF at 96 hr. All six recipients from RR-uDCD group had DGF at 48 hr and were killed. Creatinine and blood urea nitrogen (BUN) levels were significantly lower in E-uDCD compared with RR-uDCD group at 24 hr (2.9 ± 0.7 mg/dl vs. 5.2 ± 0.9 mg/dl) and 48 hr (3.2 ± 0.9 mg/dl vs. 7.2 ± 1.0 mg/dl); BUN levels at 24 and 48 hr were 28.3 ± 6.7 mg/dl vs. 39.5 ± 7.5 mg/dl and 23.9 ± 5.0 mg/dl vs. 46 ± 12.9 mg/dl, respectively. Thrombolytics plus ECS precondition organs in situ yielding functional kidneys in a porcine model of uDCD with 60 min of WIT. This procurement method addresses logistical limitations for uDCD use in the United States and could have a major impact on the organ donor pool.


Assuntos
Transplante de Rim/métodos , Rim/irrigação sanguínea , Isquemia Quente/métodos , Animais , Modelos Animais de Doenças , Testes de Função Renal , Sus scrofa , Fatores de Tempo , Doadores de Tecidos/provisão & distribuição
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...