Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Appl Opt ; 57(25): 7377, 2018 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-30182958

RESUMO

This erratum is submitted to correct information regarding Fig. 8 of Appl. Opt.57, E142 (2018)APOPAI0003-693510.1364/AO.57.00E142.

2.
Appl Opt ; 57(22): E142-E146, 2018 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-30117912

RESUMO

The characterization of an amplified piezoelectric actuator (APA) as a new axial scanning method for multiple-reference optical coherence tomography (MR-OCT) is described. MR-OCT is a compact optical imaging device based on a recirculating reference-arm-scanning optical delay using a partial mirror that can enhance the imaging depth range by more than 10 times the reference mirror's scanning amplitude. The scanning amplitude of the used APA was varied between 30 µm and 250 µm, depending on the scanning frequency of between 0.8 kHz and 1.2 kHz. A silver-coated miniature mirror was attached to the APA via ultraviolet-cured optical adhesive, and the light source was a super-luminescent diode with 1310 nm center wavelength and 56 nm bandwidth. The sensitivity was measured with and without the partial mirror in the reference delay line as a function of scan speed, frequency, and range, therefore providing results for MR-OCT and TD-OCT modes. It was found that the APA provides more than twice the mechanical scanning range compared to other opto-mechanic actuators, but results indicate degradation of signal-to-noise ratio and sensitivity at larger imaging depths. In conjunction with MR-OCT, the scan range of maximum 200 µm can be enhanced up to 1-1.5 mm by using a reduced amount of orders of reflections, which could be of interest to increase sensitivity in the future.

3.
J Biophotonics ; 11(7): e201700385, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29570942

RESUMO

For both fundamental study of biological processes and early diagnosis of diseases, information about nanoscale changes in tissue and cell structure is crucial. Nowadays, almost all currently known nanoscopy methods rely upon the contrast created by fluorescent stains attached to the object or molecule of interest. This causes limitations due to the impact of the label on the object and its environment, as well as its applicability in vivo, particularly in humans. In this paper, a new label-free approach to visualize small structure with nano-sensitivity to structural alterations is introduced. Numerically synthesized profiles of the axial spatial frequencies are used to probe the structure within areas whose size can be beyond the diffraction resolution limit. Thereafter, nanoscale structural alterations within such areas can be visualized and objects, including biological ones, can be investigated with sub-wavelength resolution, in vivo, in their natural environment. Some preliminary results, including numerical simulations and experiments, which demonstrate the nano-sensitivity and super-resolution ability of our approach, are presented.


Assuntos
Imagem Óptica , Razão Sinal-Ruído , Imageamento Tridimensional
4.
J Biomed Opt ; 22(8): 1-7, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28831794

RESUMO

A technique based on multiple reference optical coherence tomography (MR-OCT) is proposed for simultaneous imaging at multiple depths. The technique has been validated by imaging a reference sample and a fingerprint in-vivo. The principle of scanning multiple selected layers is shown by imaging a partial fingerprint with 200×200×200 voxels of 3×3×0.5 mm size and obtaining an arbitrary amount of layers merely by digital processing. The spacing among the layers can be adjusted arbitrarily, and the SNR roll-off is shown for three different spacings. At a mirror scan frequency of 1 kHz and an A-line rate of 2 kHz, the acquisition time was 20 s for one volume. The results show the feasibility of the application of layer scanning MR-OCT that uses a partial mirror in the reference arm of the Michelson interferometer. The reduced scan range required for layer scanning allows even higher scan rates that are limited only by the voice coil design and the mass-spring system, e.g., mirror mass, spring constant, and damping.


Assuntos
Dermatoglifia , Aumento da Imagem/métodos , Imagens de Fantasmas , Tomografia de Coerência Óptica/métodos , Humanos
5.
J Biomed Opt ; 21(12): 126020, 2016 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-28030742

RESUMO

Multiple reference optical coherence tomography (MR-OCT) is a technology ideally suited to low-cost, compact OCT imaging. This modality is an extension of time-domain OCT with the addition of a partial mirror in front of the reference mirror. This enables extended, simultaneous depth scanning with the relatively short scan range of a miniature voice coil motor on which the scanning mirror is mounted. This work details early stage development of the first iteration of a miniature MR-OCT device. This iteration utilizes a fiber-coupled input from an off-board superluminescent diode. The dimensions of the module are 40 × 57 ?? mm . Off-the-shelf miniature optical components, voice coil motors, and photodetectors are used, with the complexity of design depending on the specific application. The photonic module can be configured as either polarized or nonpolarized and can include balanced detection. The results shown in this work are from the nonpolarized device. The system was characterized through measurement of the input spectrum, axial resolution, and signal-to-noise ratio. Typical B-scans of static and in vivo samples are shown, which illustrate the potential applications for such a technology.


Assuntos
Dedos/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Tomografia de Coerência Óptica/instrumentação , Tomografia de Coerência Óptica/métodos , Derme/diagnóstico por imagem , Epiderme/diagnóstico por imagem , Desenho de Equipamento , Humanos
6.
Lasers Surg Med ; 48(1): 77-82, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26612183

RESUMO

BACKGROUND AND OBJECTIVES: Monitoring the curing kinetics of light-activated resin is a key area of research. These resins are used in restorative applications and particularly in dental applications. They can undergo volumetric shrinkage due to poor control of the depth dependent curing process, modulated by the intensity and duration of the curing light source. This often results in the formation of marginal gaps, causing pain and damage to the restoration site. In this study, we demonstrate the capabilities of a correlation method applied using a multiple references optical coherence tomography (MR-OCT) architecture to monitor the curing of the resin. STUDY DESIGN/MATERIALS AND METHODS: A MR-OCT system is used in this study to monitor the curing of the resin. The system operates at the center wavelength of 1310 nm with an A-scan rate of 1200 A-scans per second. The axial and lateral resolution of the system is ∼13 µm and ∼27 µm. The method to determine the intensity correlation between adjacent B-frames is based on the Pearson correlation coefficient for a region of interest. Calculating the correlation coefficient for multiple B-frames related to the first B-frame at regular spaced time points, shows for a noncured resin a reduction of the correlation coefficient over time due to Brownian motion. The time constant of the reduction of the correlation value is a measure for the progress of the polymerization during LED light irradiation of the resin. The proposed approach is potentially a low-cost, powerful and unique optical imaging modality for measuring the curing behavior of dental resin and other resins, coatings, and adhesives in medical and industrial applications. RESULTS: To demonstrate the proposed method to monitor the curing process, a light-activated resin composite from GRADIA DIRECT ANTERIOR (GC Corporation, Japan) is studied. The curing time of resin was measured and monitored as a function of depth. The correlation coefficient method is highly sensitive to Brownian motion. The process of curing results in a change in intensity as measured by the MR-OCT signal and hence can be monitored using this method. CONCLUSIONS: These results show that MR-OCT has the potential to measure the curing time and monitor the curing process as a function of depth. Moreover, MR-OCT as a product has potential to be compact, low-cost and to fit into a smartphone. Using such a device for monitoring the curing of the resin will be suitable for dentists in stationary and mobile clinical settings.


Assuntos
Resinas Compostas/farmacocinética , Lâmpadas de Polimerização Dentária , Tomografia de Coerência Óptica
7.
Appl Opt ; 54(18): 5634-8, 2015 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-26193006

RESUMO

Optical coherence tomography (OCT) is emerging as a powerful noncontact imaging technique, allowing high-quality cross-sectional imaging of scattering specimens nondestructively. However, the complexity and cost of current embodiments of an OCT system limit its use in various nondestructive testing (NDT) applications at resource-limited settings. In this paper, we demonstrate the feasibility of a novel low-cost OCT system for a range of nondestructive testing (NDT) applications. The proposed imaging system is based on an enhanced time-domain OCT system with a low cost and small form factor reference arm optical delay, called multiple reference OCT (MR-OCT), which uses a miniature voice coil actuator and a partial mirror for extending the axial scan range. The proposed approach is potentially a low-cost, compact, and unique optical imaging modality for a range of NDT applications in a low-resource setting. Using this method, we demonstrated the capability of MR-OCT to perform cross-sectional and volumetric imaging at 1200 A-scans per second.

8.
Biomed Opt Express ; 5(9): 2870-82, 2014 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-25401004

RESUMO

In this paper, we report the feasibility of integrating a novel low cost optical coherence tomography (OCT) system with a dermascope for point-of-care applications. The proposed OCT system is based on an enhanced time-domain optical coherence tomographic system, called multiple reference OCT (MR-OCT), which uses a single miniature voice coil actuator and a partial mirror for extending the axial scan range. The system can simultaneously register both the superficial dermascope image and the depth-resolved OCT sub-surface information by an interactive beam steering method. A practitioner is able to obtain the depth resolved information of the point of interest by simply using the mouse cursor. The proposed approach of combining a dermascope with a low cost OCT provides a unique powerful optical imaging modality for a range of dermatological applications. Hand-held dermascopic OCT devices would also enable point of care and remote health monitoring.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA