Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Emerg Med ; 66(3): e277-e283, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38336570

RESUMO

BACKGROUND: There is concern that the values provided by devices using infrared thermometry in emergency departments (EDs) do not reflect body core temperature accurately. OBJECTIVES: Evaluation of three thermometers commonly used in the ED. METHODS: Two infrared ear thermometers and an infrared forehead thermometer were evaluated using 1) the Voltcraft IRS-350 calibration device, 2) comparing temperature values to a rectal end-exercise temperature (T-RECT) of 38.1°C in 12 participants, and 3) comparing temperature values to rectal temperature in 133 ED patients. RESULTS: Calibration across the human core temperature range revealed that the ear thermometers underestimated radiant temperature by 0.77 ± 0.39°C and 1.84 ± 0.26°C, respectively, whereas the forehead thermometer overestimated radiant temperature by 0.90 ± 0.51°C. After cycling exercise, all thermometers underestimated T-RECT (0.54 ± 0.27°C and 1.03 ± 0.48°C for the ear thermometers and 1.14 ± 0.38°C for the forehead thermometer). In the ED, the ear thermometers underestimated T-RECT by 0.31 ± 0.37°C and 0.46 ± 0.50°C, whereas the forehead thermometer exhibited a nonsignificant overestimation of 0.04 ± 0.46°C. If the threshold for fever in all systems had been set to 37.5°C instead of 38.0°C, the sensitivity and specificity of the systems for real fever (T-RECT ≥ 38°C) are, respectively, 71% and 96% (ear thermometer 1), 57% and 97% (ear thermometer 2), and 86% and 90% (forehead thermometer). CONCLUSION: We conclude that the investigated thermometers are not reliable as devices to measure radiant temperature, cannot be used to assess body core temperature during exercise, but may be used as a screening device, with 37.5°C as a threshold for fever in emergency care settings.


Assuntos
Temperatura Corporal , Febre , Humanos , Temperatura , Febre/diagnóstico , Termômetros , Sensibilidade e Especificidade , Serviço Hospitalar de Emergência
2.
Artigo em Inglês | MEDLINE | ID: mdl-36078472

RESUMO

(1) Background: In the emergency department (ED), ordering urine tests in patients without symptoms of a urinary tract infection can lead to inappropriate antimicrobial treatment. We aimed to identify factors contributing to the unnecessary ordering of urinalyses in the ED. (2) Methods: An online survey study among nurses and physicians working in the EDs of five hospitals in the Netherlands was conducted. (3) Results: The overall response rate was 26% (221/850; 85 nurses and 136 physicians). The vast majority of the respondents reported knowing when to order urine tests (197/221; 90%). Almost two-thirds of the respondents (145/221; 66%) agreed that they ordered urinalyses because it is rapid and non-invasive to patients. Most nurses (66/86; 78%) said they informed the doctor if they thought the urine test would not contribute to the patient's diagnosis, but only one-third of the physicians agreed with this statement (44/136; 32%). Most respondents (160/221; 72%) thought guidelines or protocols about urinalyses in the ED would be functional. (4) Conclusions: These results suggest urinalyses were frequently ordered in the ED to achieve a fast work process. Nurses and physicians could improve their communication about the indications for urine tests. Developing diagnostic guidelines for urine testing may be convenient.


Assuntos
Urinálise , Infecções Urinárias , Antibacterianos/uso terapêutico , Serviço Hospitalar de Emergência , Humanos , Registros , Urinálise/métodos , Infecções Urinárias/diagnóstico , Infecções Urinárias/tratamento farmacológico , Infecções Urinárias/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...