Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Adv Mater ; 35(46): e2303142, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37515520

RESUMO

Oxide glasses are an elementary group of materials in modern society, but brittleness limits their wider usability at room temperature. As an exception to the rule, amorphous aluminum oxide (a-Al2 O3 ) is a rare diatomic glassy material exhibiting significant nanoscale plasticity at room temperature. Here, it is shown experimentally that the room temperature plasticity of a-Al2 O3 extends to the microscale and high strain rates using in situ micropillar compression. All tested a-Al2 O3 micropillars deform without fracture at up to 50% strain via a combined mechanism of viscous creep and shear band slip propagation. Large-scale molecular dynamics simulations align with the main experimental observations and verify the plasticity mechanism at the atomic scale. The experimental strain rates reach magnitudes typical for impact loading scenarios, such as hammer forging, with strain rates up to the order of 1 000 s-1 , and the total a-Al2 O3 sample volume exhibiting significant low-temperature plasticity without fracture is expanded by 5 orders of magnitude from previous observations. The discovery is consistent with the theoretical prediction that the plasticity observed in a-Al2 O3 can extend to macroscopic bulk scale and suggests that amorphous oxides show significant potential to be used as light, high-strength, and damage-tolerant engineering materials.

2.
Philos Trans A Math Phys Eng Sci ; 379(2196): 20200128, 2021 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-33715415

RESUMO

This paper presents a numerical study on thermal jet drilling of granite rock that is based on a thermal spallation phenomenon. For this end, a numerical method based on finite elements and a damage-viscoplasticity model are developed for solving the underlying coupled thermo-mechanical problem. An explicit time-stepping scheme is applied in solving the global problem, which in the present case is amenable to extreme mass scaling. Rock heterogeneity is accounted for as random clusters of finite elements representing rock constituent minerals. The numerical approach is validated based on experiments on thermal shock weakening effect of granite in a dynamic Brazilian disc test. The validated model is applied in three-dimensional simulations of thermal jet drilling with a short duration (0.2 s) and high intensity (approx. 3 MW m-2) thermal flux. The present numerical approach predicts the spalling as highly (tensile) damaged rock. Finally, it was shown that thermal drilling exploiting heating-forced cooling cycles is a viable method when drilling in hot rock mass. This article is part of the theme issue 'Fracture dynamics of solid materials: from particles to the globe'.

3.
Sci Rep ; 10(1): 15194, 2020 09 16.
Artigo em Inglês | MEDLINE | ID: mdl-32939011

RESUMO

Wearable sensors and electronic systems are of great interest these days, but their viability depends on the availability of compatible energy storage solutions. Such sensors can either be integrated into clothing or attached directly to the skin, each case presenting a different set of requirements for the devices. In this work, we examine the performance of printed supercapacitors while attached to the skin. The devices are manufactured from benign materials, such as water, carbon and sodium chloride, and worn on the forearm or chest for 24 h for durability testing. The supercapacitors exhibit excellent mechanical durability and stay well attached under all test conditions. Electrically, the supercapacitors exhibit reliable capacitive function throughout the test period; other key parameters such as equivalent series resistance and leakage current are affected but to a minimal extent. The movement and deformation of the supercapacitor show good compatibility with the skin, as shown by the Digital Image Correlation full field strain measurements on and around the capacitor. The supercapacitors deform with the skin and do not hinder normal movement or function.

4.
Science ; 366(6467): 864-869, 2019 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-31727833

RESUMO

Oxide glasses are an integral part of the modern world, but their usefulness can be limited by their characteristic brittleness at room temperature. We show that amorphous aluminum oxide can permanently deform without fracture at room temperature and high strain rate by a viscous creep mechanism. These thin-films can reach flow stress at room temperature and can flow plastically up to a total elongation of 100%, provided that the material is dense and free of geometrical flaws. Our study demonstrates a much higher ductility for an amorphous oxide at low temperature than previous observations. This discovery may facilitate the realization of damage-tolerant glass materials that contribute in new ways, with the potential to improve the mechanical resistance and reliability of applications such as electronic devices and batteries.

5.
ACS Appl Mater Interfaces ; 10(14): 11950-11960, 2018 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-29542910

RESUMO

Biopolymers are attractive candidates to fabricate biocompatible hydrogels, but the low water solubility of most of them at physiological pH has hindered their applications. To prepare a water-soluble derivative of chitosan (WSC) biopolymer, it was grafted with a small anionic amino acid, l-glutamic acid, using a single-step 1-ethyl-3-[3-dimethylaminopropyl]carbodiimide coupling reaction. This resulted in a zwitterion-tethered structure onto the polymer backbone. The degree of substitution range was 13-16 ± 1.25%, which was controlled by varying the feeding reagent ratios. Differential scanning calorimetry- and X-ray diffraction-based analysis confirmed a transition from  amorphous into a moderately amorphous/crystalline morphology after amino acid grafting, which made the derivative water-soluble at physiological pH. Composite hydrogels gelated within 60 s when using this WSC together with benzaldehyde-terminated 4-arm poly(ethylene glycol) as cross-linker. The compressive modulus of these hydrogels could be easily tuned between 4.0 ± 1.0 and 31 ± 2.5 kPa, either by changing the cross-linker concentration or total solid content in the final gel. The gels were injectable at the lowest cross-linker as well as total solid content, due to the enhanced elastic behavior. These hydrogels showed biodegradability during a 1 month incubation period in phosphate-buffered saline with weight remaining of 60 ± 1.5 and 44 ± 1.45% at pHs 7.4 and 6.5, respectively. The cytocompatibility of the gels was tested using the fibroblast cell line (i.e., WI-38), which showed good cell viability on the gel surface. Therefore, these hydrogels could be an important injectable biomaterial for delivery purpose in the future.


Assuntos
Materiais Biocompatíveis/química , Quitosana , Hidrogéis , Polietilenoglicóis
6.
Philos Trans A Math Phys Eng Sci ; 375(2085)2017 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-27956511

RESUMO

This paper presents an experimental and numerical study of Kuru grey granite impacted with a seven-buttons drill bit mounted on an instrumented drop test machine. The force versus displacement curves during the impact, so-called bit-rock interaction (BRI) curves, were obtained using strain gauge measurements for two levels of impact energy. Moreover, the volume of removed rock after each drop test was evaluated by stereo-lithography (three-dimensional surface reconstruction). A modified version of the Holmquist-Johnson-Cook (MHJC) material model was calibrated using Kuru granite test results available from the literature. Numerical simulations of the single drop tests were carried out using the MHJC model available in the LS-DYNA explicit finite-element solver. The influence of the impact energy and additional confining pressure on the BRI curves and the volume of the removed rock is discussed. In addition, the influence of the rock surface shape before impact was evaluated using two different mesh geometries: a flat surface and a hyperbolic surface. The experimental and numerical results are compared and discussed in terms of drilling efficiency through the mechanical specific energy.This article is part of the themed issue 'Experimental testing and modelling of brittle materials at high strain rates'.

7.
Philos Trans A Math Phys Eng Sci ; 375(2085)2017 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-27956513

RESUMO

This work presents a systematic study on the effects of strain rate and surface cracks on the mechanical properties and behaviour of Balmoral Red granite. The tensile behaviour of the rock was studied at low and high strain rates using Brazilian disc samples. Heat shocks were used to produce samples with different amounts of surface cracks. The surface crack patterns were analysed using optical microscopy, and the complexity of the patterns was quantified by calculating the fractal dimensions of the patterns. The strength of the rock clearly drops as a function of increasing fractal dimensions in the studied strain rate range. However, the dynamic strength of the rock drops significantly faster than the quasi-static strength, and, because of this, also the strain rate sensitivity of the rock decreases with increasing fractal dimensions. This can be explained by the fracture behaviour and fragmentation during the dynamic loading, which is more strongly affected by the heat shock than the fragmentation at low strain rates.This article is part of the themed issue 'Experimental testing and modelling of brittle materials at high strain rates'.

8.
J Biomech ; 48(10): 2217-20, 2015 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-25843258

RESUMO

Fast and accurate measurements of the kinetics and deformation of the heart during cardiac surgery can be useful for assessing the best strategies for the protection of the myocardium. While measurements based on ultrasonic technology such as the transesophageal echocardiography are rapidly developing in this direction, also other analysis methods based on optical imaging have been developed within the recent decade. The improved quality of digital cameras and increased computational power of personal computers have led to the development of deformation analysis method known as Digital Image Correlation (DIC). This paper presents preliminary results on the application of the DIC technique on analysing of the movement and deformation of the myocardial movement during a cardiopulmonary bypass surgery. The results show that the natural pattern of the heart should be sufficient for DIC, but better and more accurate results could be obtained with improved contrast conditions. DIC has a potential to be used as a sensitive tool for the surgeon to monitor the cardiac function.


Assuntos
Imageamento Tridimensional/métodos , Miografia/métodos , Ponte Cardiopulmonar , Humanos , Interpretação de Imagem Assistida por Computador , Monitorização Intraoperatória , Contração Miocárdica , Reconhecimento Automatizado de Padrão
9.
Biomed Tech (Berl) ; 60(3): 257-61, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25781661

RESUMO

Perioperative cardiosurgical management of volume therapy remains one of the challenging tasks in cases of patients with severe heart disease. Early detection of congestive cardiac failure prevents subsequent low output and worse outcome. An effective method for controlling extracorporeal circulation is created by developing a non-invasive intraoperative method for right ventricular strain analysis through digital image contrast correlation.


Assuntos
Circulação Assistida/métodos , Baixo Débito Cardíaco/etiologia , Ponte de Artéria Coronária/instrumentação , Circulação Extracorpórea/métodos , Insuficiência Cardíaca/fisiopatologia , Ventrículos do Coração/fisiopatologia , Feminino , Humanos , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA