1.
Phys Eng Sci Med ; 44(4): 1321-1329, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34724161

RESUMO

Quantitative retrospective analysis of the normal lung irradiation due to the variations of the ITV volume based on the techniques used for upper lobe (UL), mid lobe (ML), and lower lobe (LL) lung tumours when used with 2-view, 1-view, 0-view based LOT technique on Cyberknife, AveIP on Helical Tomotherapy, and DIBH on VMAT systems. In the treatment of lung tumours, patients medically inoperable or those who are unwilling to undergo surgery have the option to be treated using radiation therapy. There are many motion control techniques available for the treatment of the moving target, such as movement encompassment, respiratory gating, breath-hold, motion reduction, and tumour monitoring. ITV generation is dependent on technique and hence the volume of the PTVs will differ based on the technique used. This study aimed to determine the influence of these ITVs on the irradiated normal lung volume for UL, ML, and LL lung tumours for 23 patients. The mean difference in the PTV volumes generated with the 0-view technique was significant with that of 2-view and DIBH techniques (p-value < 0.04). The mean difference in the PTV volumes generated by 2-view and DIBH was small for UL, ML, and LL tumours. V5 of the combined lung with the 0-view method was 5% compared to the 2-view method for UL tumours (p-value = 0.04) and the same was 9.5%, and 16.8% for ML and LL tumours (p-value < 0.04). In contrast to all other techniques, lung volume parameters V5, V10, V20, and V30 for the 0-view technology were consistently higher irrespective of the tumour location in the lung. The observed maximum mean lung dose (MLD) was 6.2 Gy ± 2.7 Gy with the 0-view technique and the minimum was 3.85 Gy ± 1.75 Gy with the DIBH technique. The difference in MLD between DIBH and 2-view was negligible (p-value = 0.67). The MLD increased for LL tumours from 4 Gy to 6.5 Gy from the 2-view to 0-view technique (p-value = 0.009). There was a significant increase in MLD for LL tumours with the 0-view technique compared to AveIP (1.9 Gy, p-value = 0.04) and DIBH (2.0 Gy, p-value = 0.003) technique. For ML and UL tumours, except for 0-view and 1-view, the difference in the MLD between the rest of the methods was not significant (p-value > 0.11). In the treatment of lung tumour patients with SBRT, this study has demonstrated 2-view with Cyberknife and DIBH with VMAT treatment techniques have optimal normal lung tissue sparing. There was a significant increase in the average lung volume receiving 5%,10%, 20%, and 30% dose when comparing the 1-view, 0-view, AveIP, and DIBH techniques to the 2-view technique. However, DIBH with VMAT was dosimetrically advantageous for ML and LL tumours, while providing significantly shorter treatment times than any other technique studied.


Assuntos
Radiocirurgia , Radioterapia de Intensidade Modulada , Humanos , Pulmão , Aceleradores de Partículas , Estudos Retrospectivos
2.
Indian J Gastroenterol ; 40(4): 389-401, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34694581

RESUMO

BACKGROUND: This is a prospective study evaluating the role of stereotactic body radiotherapy (SBRT) with CyberKnife (CK) in Indian patients suffering from hepatocellular carcinoma with portal vein thrombosis (HCC-PVT). METHODS: Patients with inoperable HCC-PVT, good performance score (PS), and liver function are accrued for treatment on CK (version M6) and planned with Multiplan (iDMS V2.0). Triple-phase contrast computed tomography (CT) scan was done for contouring, and the gross tumor volume (GTV) included contrast-enhancing mass within main portal vein and adjacent parenchymal disease. Dose prescription was as per-risk stratification protocol (22-50 Gy in 5 fractions) while achieving the constraints of mean liver dose <15 Gy, 800 cc liver <8 Gy, and the duodenum max of ≤24 Gy). RESULTS: Seventy-two HCC-PVT accrued till date (mean age 63 years [38-76 years], 96% male; Child-Pugh [CP] A 84%, B 9%; Barcelona-Clinic Liver Cancer [BCLC] C 96%; PS0-1: 80%, Karnofsky performance score [KPS]>70: 88%; co-morbidities 42%; infective 12%, alcohol intake 31%, adjuvant sorafenib 39%). CP scores 5, 6, 7, and 8 were in 35%, 32%, 8%, and 18%, respectively. Focal disease with portal vein thrombus (PVT) in 21%, liver involvement >50% and <50% in 46% and 32%. Liver cancer study group of Japan staging-based portal vein invasion VP2, VP3, and VP4 in 22%, 29%, and 40%. Cancer of the Liver Italian Programm (CLIP) scores 1, 2, 3, 4, and 5 were in 8%, 26%, 31%, 26%, and 7%, respectively. Mean follow-up was 7.3 months (median 6 months, standard deviation [SD] 6; range 3-30 months). Mean actuarial overall survival (OS) was 11.4 months (SE 1.587; 95% CI: 8-14.2 months). Six months and 12 months actuarial OS 55% and 38%, respectively. At last follow-up, 25/69 (36%) were alive and 44/69 (64%) were dead. Among 54 patients evaluated for response assessment, 23 (30%) had radiological confirmed PVT response, 1 (3%) had response of IVC thrombus, and 30 (42%) had no or minimal response to SBRT. Actuarial OS in responders and non-responders were 14.4 months (95% CI 9.4-19.2) and 7.4 months (95% CI 4.9-9.7), p-value: 0.022. Six and 12 months survival in responders and non-responders were 65.7% and 37% and 49% and 24.6%, respectively. Post-SBRT, 4 (12%) patients underwent transarterial chemoembolization (TACE) 3 patients (8%) and 1 patient (4%) transarterial radioembolization (TARE). Post-CK, (<4 weeks) 2 patients (4%) had decompensation. CONCLUSIONS: PVT response or recanalization after SBRT is a statistically significant prognostic factor for survival function in HCC-PVT.


Assuntos
Carcinoma Hepatocelular/terapia , Quimioembolização Terapêutica , Neoplasias Hepáticas/terapia , Radiocirurgia , Procedimentos Cirúrgicos Robóticos , Trombose Venosa/terapia , Adulto , Carcinoma Hepatocelular/complicações , Feminino , Humanos , Neoplasias Hepáticas/complicações , Masculino , Pessoa de Meia-Idade , Veia Porta , Estudos Prospectivos , Resultado do Tratamento , Trombose Venosa/etiologia
3.
Rep Pract Oncol Radiother ; 26(3): 380-388, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34277091

RESUMO

BACKGROUND: The advances in image guidance and capability of highly conformal dose deliveries made possible the use of helical tomotherapy (HT) for lung cancer treatment. To determine the effect of respiratory motion on the delivered dose in HT, film dosimetry using a dynamic phantom was performed. This was a phantom study to determine the effect of motion on the delivered dose in HT. MATERIALS AND METHODS: 4D computed tomography (4DCT) was acquired for various target motions of CIRS dynamic phantom (CIRS Inc., Norfolk, USA) with 2.5cm diameter spherical target of volume 8.2 cc moving in the COS4 motion pattern. AveIP images and treatment plans were generated in the HT planning system. Target excursions during treatment delivery were changed in the superior-inferior, anteroposterior and lateral directions. The breathing cycle time was varied from 4 to 5 sec. and also the delivery interruptions were introduced. A film was exposed for each delivery and gamma analysis was performed. RESULTS: The gamma pass rate (GPR) with 3%, 2 mm criteria for the target motion in the S-I direction showed a significant reduction from 97.5% to 54.4% as the motion increased from 3 mm to 8 mm (p = 0.03). For the target motion in S-I = 8 mm, L-R = A-P = 3 mm, the percentage decrease in the GPR was 74% (p = 0.001) for three interruptions. CONCLUSION: The ITV based approach in HT is ideal for a shallow breathing situation when the tumor excursions were confined to 5 mm in the S-I and 3 mm in L-R and A-P directions.

4.
Phys Eng Sci Med ; 44(2): 425-432, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33770384

RESUMO

The aim of this study was to design and fabricate a thorax phantom to quantify the radiation doses to the region of the chest wall (with 3 ionization chambers), the organ at risk (OAR) (lung), and the surface using radiochromic films (EBT3) for three different 3D CRT treatment planning techniques. Anthropomorphic phantoms are one of the best tools for verifying the quality of the radiotherapy treatment plans generated by treatment planning systems since they can provide equivalent human tissue densities. Thirty acrylic plates were cut into ellipses 21 cm in height and 31 cm in width, and slots were created to insert lung equivalent cork material and bone equivalent Teflon material. Three treatment planning techniques were designed: (A) tangential pair beams, (B) tangential pair beams with wedges and (C) tangential beams followed by an anterior oblique beam. The percentage difference between the measured point doses and the calculated doses (measured with three CC13 ionization chambers) ranged from - 3.2 to 1.6%, with a mean deviation of - 1.04 ± 1.3%. The measured mean percentage doses on the target surface with EBT3 film were 90.3% and 95.1% of the prescribed dose with 5-mm and 10-mm boluses, respectively. Finally, the average absolute dose difference between the measured and calculated surface doses was within 10 cGy in all three planning techniques. The developed thorax phantom is suitable for point dose measurements using ionization chambers and for surface dose measurements using EBT3 Gafchromic films in post-mastectomy chest wall radiotherapy.


Assuntos
Neoplasias da Mama , Parede Torácica , Feminino , Humanos , Mastectomia , Imagens de Fantasmas , Técnicas de Planejamento
5.
Radiol Med ; 126(3): 453-459, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32803540

RESUMO

OBJECTIVES: Motivation of this study is to check the sensitivity of dosimetric tool gamma with 2D detector array combination when unexpected errors occur while transferring intensity-modulated radiation therapy treatment plans from planning system to treatment unit. METHODS: This study consists of 17 head and neck cancer patient's treatment plans. Nine types of verification plans are created for all 17 clinically approved treatment plans by consecutively deleting different segments (up to eight) one by one from each field of the plan. Decrement factor (χ) is introduced in our study which illustrated the degree of decay of gamma passing rate when intentional errors are introduced. We analyzed the data by two different methods-one without selecting the region of interest (ROI) in dose distributions and the other by selecting the region of interest. RESULTS: By linear regression, the absolute value of slopes is 0.025, 0.024 and 0.015 without ROI and 0.030, 0.027 and 0.015 with ROI for 2%/2 mm, 3%/3 mm and 5%/5 mm criteria, respectively. The higher absolute value of the fitted slope indicates the higher sensitivity of this method to identify erroneous plan in treatment unit. The threshold value for 2%/2 mm equivalent to 95% passing criteria in 3%/3 mm used in clinical practice is obtained as 83.44%. CONCLUSIONS: The 2D detector array with dosimetric tool gamma is less sensitive in detecting errors when unprecedented errors of segment deletion occur within the treatment plans.


Assuntos
Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/radioterapia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Erros de Configuração em Radioterapia , Radioterapia de Intensidade Modulada/métodos , Algoritmos , Humanos , Modelos Lineares , Aceleradores de Partículas , Radiometria/métodos , Radioterapia de Intensidade Modulada/instrumentação , Sensibilidade e Especificidade
6.
Radiat Oncol J ; 38(4): 253-261, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33249803

RESUMO

BACKGROUND: Evaluate morbidities and "quality" of fiducial marker placement in primary liver tumours (hepatocellular carcinoma [HCC]) for CyberKnife. MATERIALS AND METHODS: Thirty-six HCC with portal vein thrombosis(PVT) were evaluated for "quality" of fiducial placement, placement time, pain score, complications, recovery time and factors influencing placement. RESULTS: One hundred eight fiducials were placed in 36 patients. Fiducial placement radiation oncologist score was "good" in 24(67%), "fair" in 4(11%), and "poor" in 3(8%) patients. Concordance with radiologist score in "poor", "fair", and "good" score was 2/2(100%), 4/5(80%), and 24/27(89%), respectively(p=0.001). Child-Pugh score(p=0.080), performance status(PS) (p=0.014) and accrued during "learning curve"(p=0.013) affected placement score. Mean placement time(p=0.055), recovery time(p=0.025) was longer and higher major complications(p=0.009) with poor PS. Liver segment involved(p=0.484) and the Barcelona Clinic Liver Cancer(BCLC) stage did not influence placement score. "Good" placement score was 30% in first cohort whereas 93% in last cohort(p=0.023). Time for placement was 42.2 and 14.3 minutes, respectively(p=0.069). Post-fiducial pain score 0-1 in 26 patients(72%) and pain score 3-4 was in 2(6%). Five patients (14%) admitted in "day-care"(2 mild pneumothorax, 3 pain). Mortality in 1 patient(3%) admitted for hemothorax. CONCLUSION: Fiducial placement is safe and in experienced hands, "quality" of placement is "good" in majority. Major complications and admission after fiducial placement are rare. Complications, fiducial placement time, recovery time is more during the "learning curve". Poor Child-Pugh score, extensive liver involvement, poor PS have higher probability of complications.

7.
J Med Phys ; 44(3): 145-155, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31576063

RESUMO

PURPOSE: An experimental method using the linear portion of the relative film dose-response curve for radiographic and radiochromic films is presented, which can be used to determine the relative depth doses in a variety of very small, medium, and large radiation fields and relative output factors (ROFs) for small fields. MATERIALS AND METHODS: The film slope (FS) method was successfully applied to obtain the percentage depth doses (PDDs) for external beams of photon and electrons from a Synergy linear accelerator (Elekta AB, Stockholm, Sweden) under reference conditions of 10 cm × 10 cm for photon beam and nominal 10 cm × 10 cm size applicator for electron beam. For small-field dosimetry, the FS method was applied to EDR2 films (Carestream Health, Rochester, NY) for 6 MV photon beam from a linac (Elekta AB, Stockholm, Sweden) and small, circular radiosurgery cones (Elekta AB, Stockholm, Sweden) with diameters of 5, 7.5, 10, 12.5, and 15 mm. The ROFs for all these cones and central axis PDDs for 5, 10, and 15 mm diameter cones were determined at source-to-surface distance of 100 cm. The ROFs for small fields of CyberKnife system were determined using this technique with Gafchromic EBT3 film (Ashland, NJ, USA). The PDDs and ROFs were compared with ion chamber (IC) and Monte Carlo (MC) simulated values. RESULTS: The maximum percentage deviation of PDDFS with PDDIC for 4, 6, and 15 MV photon beams was within 1.9%, 2.5%, and 1.4%, respectively, up to 20-cm depth. The maximum percentage deviation of PDDFS with PDDIC for electron beams was within 3% for energy range studied of 8-15 MeV. The gamma passing rates of PDDFS with PDDIC were above 96.5% with maximum gamma value of >2, occurring at the zero depths for 4, 6, and 15 MV photons. For electron beams, the gamma passing rates between PDDFS with PDDIC were above 97.7% with a maximum gamma value of 0.9, 1.3, and 0.7 occurring at the zero depth for 8, 12, and 15 MeV. For small field of 5-mm cone, the ROFFS was 0.665 ± 0.021 as compared to 0.674 by MC method. The maximum percentage deviation between PDDFS and PDDMC was 3% for 5 mm and 10 mm and 2% for 15 mm cones with 1D gamma passing rates, respectively, of 95.5%, 96%, and 98%. For CyberKnife system, the ROFFS using EBT3 film and MC published values agrees within 0.2% for for 5 mm cone. CONCLUSIONS: The authors have developed a novel and more accurate method for the relative dosimetry of photon and electron beams. This offers a unique method to determine PDD and ROF with a high spatial resolution in fields of steep dose gradient, especially in small fields.

8.
J Med Phys ; 44(2): 77-83, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31359924

RESUMO

AIMS AND OBJECTIVES: The influence of target motion on the reconstructed internal target volume (ITV) for device-based (DB) external surrogate system and Smart deviceless (DL) 4-dimensional (4D) system were compared in a controlled phantom experiment. The volumetric changes in reconstructed ITVs from the average intensity projection (AveIP) images using DB method (Anzai Respiratory Gating System, ANZAI MEDICAL CO., LTD, Japan) and DL method (Smart deviceless 4D system by GE Medical Systems (Chicago, USA)) with the theoretical true volume (ITVth) for moving target with the increasing target motion in anterior-posterior (A-P), lateral (left-right [L-R]) and inferior-superior (S-I) directions were assessed. MATERIALS AND METHODS: 4D computed tomography (4DCT) of CIRS dynamic phantom (Computerized Imaging Reference Systems Inc., Norfolk, VA, USA) with 2.5 cm diameter spherical target of volume 8.2 cc programmed to move in a cos4(x) motion pattern placed in the lung volume were acquired for various target motion pattern using DB and DL method of gating. AveIP images of 10 phase binned image sets were generated and ITVs were delineated. RESULTS: The maximum absolute percent differences between ITVave and ITVth for DL and DB methods were 15.91% and 4.94 % respectively for target motion of 5 mm in AP with 15 mm S-I direction. When the S-I motion was decreased to 10 mm, the observed % difference of the ITVs were also decreased to 12.5% and 0.3% for DL and DB method. When the lateral [L-R] motion was varied from 0 mm to 5 mm for S-I motion of 5 mm to 15 mm, the differences in the ITVs were significant (P = 0.004) with the maximum absolute percent difference of 18.61% and 4.94 % for DL and DB gating. With the simultaneous motion of the target in all the 3 directions, the difference in the reconstructed ITVs were statistically significant for DL method (P = 0.0002) and insignificant for DB method (P = 0.06) with an average increase of 10% in ITVDL against 2% in the ITVDB. The difference in ITVDL was significant for the target motion above 3 mm in A-P and L-R directions for S-I movement of above 10 mm (P = 0.0002). However, for low excursions of the target movement, no significant difference in the ITVs were observed (P > 0.06). In general, ITVDBs were closer to the ITVth (within 7.8%) than ITVDL (18.61%). CONCLUSION: The results showed that the DL method is an effective way of image sorting in 4D acquisition for smaller target excursion. When the target motion exceeds 3 mm in A-P and L-R directions with S-I more than 10 mm, DB method is the choice due to its accuracy in reproducing the absolute target volume.

11.
J Cancer Res Ther ; 13(2): 262-267, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28643745

RESUMO

BACKGROUND: Breast cancer tissue is sensitive to hypofractionation. This is an analysis of patients treated with hypofractionated protocols since 2009, at our tertiary cancer center. METHODS: Details of breast cancer patients treated with adjuvant hypofractionated external beam radiation therapy (EBRT) from January 2009 to December 2014 were retrieved and analyzed. RESULTS: One thousand seven hundred and eighty patients received adjuvant EBRT during this period. Three hundred and eight were offered hypofractionated schedule. One hundred and eighty-eight had modified radical mastectomy (MRM) and 120 had breast conservation surgery (BCS). Dose was 40 Gy in 15 fractions to chest wall/breast, and tumor bed boost of 10 Gy in 5 fractions, where indicated, using three-dimensional conformal radiotherapy (3DCRT). Electrons were used in 159 and photons in 149. Single en face electron field was used for chest wall in MRM patients, and tangential photon beams for the whole breast. Patients on follow-up were assessed for locoregional recurrence, chest wall, breast or ipsilateral upper limb edema, brachial neuralgia, local skeletal events, pulmonary and cardiac symptoms, and cosmetic results. Two developed chest wall recurrence, one each in electron and photon arms. No skeletal, cardiac, or pulmonary adverse events were recorded. About 13.6% had arm edema, which was staged according to the International Society of Lymphology lymphedema staging, as Stage I-7.8%, Stage II-3.9%, and Stage III-1.9%. Twenty-six treated with electrons had arm edema. Increased incidence of arm edema in MRM patients could be attributed to combined surgical and radiation morbidity. Five-year overall survival was 81.9%. CONCLUSION: Hypofractionation is an accepted cost-effective standard of care in adjuvant breast radiation. Single en face electron field is well tolerated, and 3DCRT planning ensures homogeneous chest wall coverage, respecting dose constraints to organs at risk.


Assuntos
Neoplasias da Mama Masculina/radioterapia , Neoplasias da Mama/radioterapia , Fracionamento da Dose de Radiação , Adulto , Idoso , Idoso de 80 Anos ou mais , Elétrons , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fótons , Radioterapia/métodos , Resultado do Tratamento
12.
J Cancer Res Ther ; 10(4): 937-41, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25579532

RESUMO

PURPOSE: A prospective study was undertaken to evaluate the influence of patient positioning on the set up variations to determine the planning target volume (PTV) margins and to evaluate the clinical relevance volume assessment of the small bowel (SB) within the irradiated volume. MATERIALS AND METHODS: During the period of months from December 2011 to April 2012, a computed tomography (CT) scan was done either in supine position or in prone position using a belly board (BB) for 20 consecutive patients. All the patients had histologically proven rectal cancer and received either post- or pre-operative pelvic irradiation. Using a three-dimensional planning system, the dose-volume histogram for SB was defined in each axial CT slice. Total dose was 46-50 Gy (2 Gy/fraction), delivered using the 4-field box technique. The set up variation of the study group was assessed from the data received from the electronic portal imaging device in the linear accelerator. The shift along X, Y, and Z directions were noted. Both systematic and random errors were calculated and using both these values the PTV margin was calculated. RESULTS: The systematic errors of patients treated in the supine position were 0.87 (X-mm), 0.66 (Y-mm), 1.6 (Z-mm) and in the prone position were 1.3 (X-mm), 0.59 (Y-mm), 1.17 (Z-mm). The random errors of patients treated in the supine positions were 1.81 (X-mm), 1.73 (Y-mm), 1.83 (Z-mm) and in prone position were 2.02 (X-mm), 1.21 (Y-mm), 3.05 (Z-mm). The calculated PTV margins in the supine position were 3.45 (X-mm), 2.87 (Y-mm), 5.31 (Z-mm) and in the prone position were 4.91 (X-mm), 2.32 (Y-mm), 5.08 (Z-mm). The mean volume of the peritoneal cavity was 648.65 cm 3 in the prone position and 1197.37 cm 3 in the supine position. CONCLUSION: The prone position using BB device was more effective in reducing irradiated SB volume in rectal cancer patients. There were no significant variations in the daily set up for patients treated in both supine and prone positions.


Assuntos
Carcinoma/radioterapia , Decúbito Ventral , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias Retais/radioterapia , Decúbito Dorsal , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Radiometria , Dosagem Radioterapêutica , Reto/diagnóstico por imagem , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X , Adulto Jovem
13.
Rep Pract Oncol Radiother ; 18(2): 87-94, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-24416535

RESUMO

AIM: To compare and evaluate the performance of two different volumetric modulated arc therapy delivery techniques. BACKGROUND: Volumetric modulated arc therapy is a novel technique that has recently been made available for clinical use. Planning and dosimetric comparison study was done for Elekta VMAT and Varian RapidArc for different treatment sites. MATERIALS AND METHODS: Ten patients were selected for the planning comparison study. This includes 2 head and neck, 2 oesophagus, 1 bladder, 3 cervix and 2 rectum cases. Total dose of 50 Gy was given for all the plans. All plans were done for RapidArc using Eclipse and for Elekta VMAT with Monaco treatment planning system. All plans were generated with 6 MV X-rays for both RapidArc and Elekta VMAT. Plans were evaluated based on the ability to meet the dose volume histogram, dose homogeneity index, radiation conformity index, estimated radiation delivery time, integral dose and monitor units needed to deliver the prescribed dose. RESULTS: RapidArc plans achieved the best conformity (CI95% = 1.08 ± 0.07) while Elekta VMAT plans were slightly inferior (CI95% = 1.10 ± 0.05). The in-homogeneity in the PTV was highest with Elekta VMAT with HI equal to 0.12 ± 0.02 Gy when compared to RapidArc with 0.08 ± 0.03. Significant changes were observed between the RapidArc and Elekta VMAT plans in terms of the healthy tissue mean dose and integral dose. Elekta VMAT plans show a reduction in the healthy tissue mean dose (6.92 ± 2.90) Gy when compared to RapidArc (7.83 ± 3.31) Gy. The integral dose is found to be inferior with Elekta VMAT (11.50 ± 6.49) × 10(4) Gy cm(3) when compared to RapidArc (13.11 ± 7.52) × 10(4) Gy cm(3). Both Varian RapidArc and Elekta VMAT respected the planning objective for all organs at risk. Gamma analysis result for the pre-treatment quality assurance shows good agreement between the planned and delivered fluence for 3 mm DTA, 3% DD for all the evaluated points inside the PTV, for both VMAT and RapidArc techniques. CONCLUSION: The study concludes that a variable gantry speed with variable dose rate is important for efficient arc therapy delivery. RapidArc presents a slight improvement in the OAR sparing with better target coverage when compared to Elekta VMAT. Trivial differences were noted in all the plans for organ at risk but the two techniques provided satisfactory conformal avoidance and conformation.