Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 64
Filtrar
1.
Med Phys ; 49(2): 878-890, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34894402

RESUMO

BACKGROUND: The development of clinically meaningful, objective, and quantitative methods for assessing the performance of ultrasound imaging systems represents a continuing area of interest. One approach has been to image phantoms with randomly distributed spherical voids. PURPOSE: The objectives of this study were: (1) to explore the potential of using relatively high-volume fraction random spherical void (RSV) phantoms as an approach for quantitatively assessing the performance of ultrasound imaging systems; (2) to identify potential metrics that can be used to provide quantitative assessments of images obtained from relatively high-volume fraction RSV phantoms; and (3) to demonstrate changes in the quantitative metrics that can occur as image features are degraded. METHODS: A series (10 each) of computer-simulated RSV phantoms with a range of RSV volume fractions (0.05, 0.15, and 0.25) were generated. To determine the number of image planes necessary to provide robust measurements, a series of consecutive planes (ranging from 1 to 150) within each type of simulated phantom were analyzed. The observed circular cross-section radii histogram distributions (representing the intersection of each plane with the local distribution of spherical voids) were compared with the theoretical histogram distribution. Simulated phantom images were produced by adding speckle and degradation of imaging system performance was modeled by averaging 1 to 9 neighboring planes to represent increasing elevation plane thicknesses. Quantification of the performance of the imaging system was determined by measuring the: (1) mean number of circular cross-sections detected per image frame; (2) mean fractional area of circular cross-sections detected per image frame; (3) agreement of observed circular cross-section radii histogram distribution with the theoretical distribution (Chi-square statistic); and (4) contrast and contrast-to-noise ratio as a function of observed circular cross-section radius. RESULTS: Results suggest that analyses of a sufficient number of image planes (providing over approximately 3000 total circular cross-sectional areas) provides excellent agreement between the observed and theoretical histogram distributions (mean Chi-square < 0.004). For the 0.15 volume fraction series of simulated RSV phantoms, using 150 image plane analyses, phantom images show decreasing mean number of circle cross-sections detected per frame (31.5 ± 0.3, 28.4 ± 0.3, 28.2 ± 0.3, 26.3 ± 0.3, and 25.3 ± 0.3); decreasing mean fractional area of circle cross-sections per frame (0.157 ± 0.002, 0.133 ± 0.001, 0.133 ± 0.001, 0.111 ± 0.001, and 0.108 ± 0.001); and a decreasing agreement with the theoretical histogram distribution of radii (Chi-square values: 0.070 ± 0.004, 0.140 ± 0.005, 0.149 ± 0.007, 0.379 ± 0.011, and 0.518 ± 0.010) for 1, 3, 5, 7, and 9 plane averages, respectively. Contrast and contrast-to-noise measurements as a function of observed circular cross-section radius also demonstrate marked changes with simulated image degradation. CONCLUSIONS: Results of this simulation study suggest that analyses of images obtained from relatively high-density RSV phantoms may offer a promising approach for assessing ultrasound imaging systems. The proposed measurements appear to provide reproducible, robust, quantitative metrics that can be compared with corresponding theoretical values to provide quantifiable, objective metrics of imaging system performance.


Assuntos
Processamento de Imagem Assistida por Computador , Simulação por Computador , Imagens de Fantasmas , Ultrassonografia
2.
Sci Rep ; 8(1): 7561, 2018 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-29765087

RESUMO

We are introducing the FABRICA, a bioprinter-agnostic 3D-printed bioreactor platform designed for 3D-bioprinted tissue construct culture, perfusion, observation, and analysis. The computer-designed FABRICA was 3D-printed with biocompatible material and used for two studies: (1) Flow Profile Study: perfused 5 different media through a synthetic 3D-bioprinted construct and ultrasonically analyzed the flow profile at increasing volumetric flow rates (VFR); (2) Construct Perfusion Study: perfused a 3D-bioprinted tissue construct for a week and compared histologically with a non-perfused control. For the flow profile study, construct VFR increased with increasing pump VFR. Water and other media increased VFR significantly while human and pig blood showed shallow increases. For the construct perfusion study, we confirmed more viable cells in perfused 3D-bioprinted tissue compared to control. The FABRICA can be used to visualize constructs during 3D-bioprinting, incubation, and to control and ultrasonically analyze perfusion, aseptically in real-time, making the FABRICA tunable for different tissues.


Assuntos
Reatores Biológicos , Desenho de Equipamento/métodos , Animais , Bioimpressão/instrumentação , Desenho Assistido por Computador , Humanos , Perfusão/instrumentação , Impressão Tridimensional/instrumentação , Técnicas de Cultura de Tecidos/instrumentação
3.
Pediatr Res ; 82(5): 768-775, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28604759

RESUMO

BackgroundTo test the hypothesis that infants born to obese women with pre-gestational type 2 diabetes mellitus (IBDMs) have ventricular dysfunction at 1 month that is associated with markers of maternal lipid and glucose metabolism.MethodsIn a prospective observational study of IBDMs (OB+DM, n=25), echocardiographic measures of septal, left (LV) and right ventricular (RV) function, and structure were compared at 1 month of age with those in infants born to OB mothers without DM (OB, n=24) and to infants born to non-OB mothers without DM (Lean, n=23). Basal maternal lipid and glucose kinetics and maternal plasma and infant (cord) plasma were collected for hormone and cytokine analyses.ResultsRV, LV, and septal strain measures were lower in the OB+DM infants compared with those in other groups, without evidence of septal hypertrophy. Maternal hepatic insulin sensitivity, maternal plasma free-fatty-acid concentration, and cord plasma insulin and leptin most strongly predicted decreased septal strain in OB+DM infants.ConclusionIBDMs have reduced septal function at 1 month in the absence of septal hypertrophy, which is associated with altered maternal and infant lipid and glucose metabolism. These findings suggest that maternal obesity and DM may have a prolonged impact on the cardiovascular health of their offspring, despite the resolution of cardiac hypertrophy.


Assuntos
Glicemia/metabolismo , Diabetes Mellitus Tipo 2/complicações , Lipídeos/sangue , Obesidade/complicações , Gravidez em Diabéticas , Efeitos Tardios da Exposição Pré-Natal , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Direita/etiologia , Função Ventricular Esquerda , Função Ventricular Direita , Adulto , Biomarcadores/sangue , Diabetes Mellitus Tipo 2/sangue , Diabetes Mellitus Tipo 2/diagnóstico , Ecocardiografia , Feminino , Sangue Fetal/metabolismo , Humanos , Lactente , Recém-Nascido , Obesidade/sangue , Obesidade/diagnóstico , Gravidez , Estudos Prospectivos , Fatores de Risco , Fatores de Tempo , Disfunção Ventricular Esquerda/sangue , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Direita/sangue , Disfunção Ventricular Direita/diagnóstico por imagem , Disfunção Ventricular Direita/fisiopatologia , Adulto Jovem
4.
J Am Soc Echocardiogr ; 30(7): 685-698.e1, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28433214

RESUMO

BACKGROUND: The aim of this study was to determine the maturational changes in systolic ventricular strain mechanics by two-dimensional speckle-tracking echocardiography in extremely preterm neonates from birth to 1 year of age and discern the impact of common cardiopulmonary abnormalities on the deformation measures. METHODS: In a prospective multicenter study of 239 extremely preterm infants (<29 weeks gestation at birth), left ventricular (LV) global longitudinal strain (GLS) and global longitudinal systolic strain rate (GLSRs), interventricular septal wall (IVS) GLS and GLSRs, right ventricular (RV) free wall longitudinal strain and strain rate, and segmental longitudinal strain in the RV free wall, LV free wall, and IVS were serially measured on days 1, 2, and 5 to 7, at 32 and 36 weeks postmenstrual age, and at 1 year corrected age (CA). Premature infants who developed bronchopulmonary dysplasia or had echocardiographic findings of pulmonary hypertension were analyzed separately. RESULTS: In uncomplicated preterm infants (n = 103 [48%]), LV GLS and GLSRs remained unchanged from days 5 to 7 to 1 year CA (P = .60 and P = .59). RV free wall longitudinal strain, RV free wall longitudinal strain rate, and IVS GLS and GLSRs significantly increased over the same time period (P < .01 for all measures). A significant base-to-apex (highest to lowest) segmental longitudinal strain gradient (P < .01) was seen in the RV free wall and a reverse apex-to-base gradient (P < .01) in the LV free wall. In infants with bronchopulmonary dysplasia and/or pulmonary hypertension (n = 119 [51%]), RV free wall longitudinal strain and IVS GLS were significantly lower (P < .01), LV GLS and GLSRs were similar (P = .56), and IVS segmental longitudinal strain persisted as an RV-dominant base-to-apex gradient from 32 weeks postmenstrual age to 1 year CA. CONCLUSIONS: This study tracks the maturational patterns of global and regional deformation by two-dimensional speckle-tracking echocardiography in extremely preterm infants from birth to 1 year CA. The maturational patterns are ventricular specific. Bronchopulmonary dysplasia and pulmonary hypertension leave a negative impact on RV and IVS strain, while LV strain remains stable.


Assuntos
Ecocardiografia/métodos , Lactente Extremamente Prematuro , Sístole/fisiologia , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Direita/diagnóstico por imagem , Disfunção Ventricular Direita/fisiopatologia , Comorbidade , Feminino , Humanos , Lactente , Masculino , Estudos Prospectivos
5.
J Am Soc Echocardiogr ; 29(11): 1056-1065, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27641101

RESUMO

BACKGROUND: Pulmonary artery acceleration time (PAAT) is a noninvasive method to assess pulmonary hemodynamics, but it lacks validity in children. The aim of this study was to evaluate the accuracy of Doppler echocardiography-derived PAAT in predicting right heart catheterization (RHC)-derived pulmonary artery pressure (PAP), pulmonary vascular resistance (PVR), and compliance in children. METHODS: Prospectively acquired and retrospectively measured Doppler echocardiography-derived PAAT and RHC-derived systolic PAP, mean PAP (mPAP), indexed PVR (PVRi), and compliance were compared using regression analysis in a derivation cohort of 75 children (median age, 5.3 years; interquartile range, 1.3-12.6 years) with wide ranges of pulmonary hemodynamics. To account for heart rate variability, PAAT was adjusted for right ventricular ejection time and corrected by the RR interval. Regression equations incorporating PAAT and PAAT/right ventricular ejection time from the derivation cohort were then evaluated for the accuracy of their predictive values for invasive pulmonary hemodynamics in a validation cohort of 50 age- and weight-matched children with elevated PAP and PVR. RESULTS: There were significant inverse correlations between PAAT and RHC-derived mPAP (r = -0.82) and PVRi (r = -0.78) and a direct correlation (r = 0.78) between PAAT and pulmonary compliance in the derivation cohort. For detection of pulmonary hypertension (PRVi > 3 Wood units · m2 and mPAP > 25 mm Hg), PAAT < 90 msec and PAAT/right ventricular ejection time < 0.31 resulted in sensitivity of 97% and specificity of 95%. In the derivation cohort, the regression equations relating PAAT with mPAP and PVRi were mPAP = 48 - 0.28 × PAAT and PVRi = 9 - 0.07 × PAAT. These PAAT-integrated equations predicted RHC-measured pulmonary hemodynamics in the validation cohort with good correlations (r = 0.88 and r = 0.83, respectively), small biases (<10%), and minimal coefficients of variation (<8%). CONCLUSIONS: PAAT inversely correlates with RHC-measured pulmonary hemodynamics and directly correlates with pulmonary arterial compliance in children. The study established PAAT-based regression equations in children to accurately predict RHC-derived PAP and PVR.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Determinação da Pressão Arterial/métodos , Ecocardiografia Doppler/métodos , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/fisiologia , Circulação Pulmonar/fisiologia , Pressão Propulsora Pulmonar/fisiologia , Aceleração , Criança , Pré-Escolar , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Lactente , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resistência Vascular/fisiologia
6.
J Am Soc Echocardiogr ; 29(3): 209-225.e6, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26747685

RESUMO

BACKGROUND: Establishment of the range of reference values and associated variations of two-dimensional speckle-tracking echocardiography (2DSTE)-derived left ventricular (LV) strain is a prerequisite for its routine clinical adoption in pediatrics. The aims of this study were to perform a meta-analysis of normal ranges of LV global longitudinal strain (GLS), global circumferential strain (GCS), and global radial strain (GRS) measurements derived by 2DSTE in children and to identify confounding factors that may contribute to variance in reported measures. METHODS: A systematic review was launched in MEDLINE, Embase, Scopus, the Cumulative Index to Nursing and Allied Health Literature, and the Cochrane Library. Search hedges were created to cover the concepts of pediatrics, STE, and left-heart ventricle. Two investigators independently identified and included studies if they reported 2DSTE-derived LV GLS, GCS, or GRS. The weighted mean was estimated by using random effects models with 95% CIs, heterogeneity was assessed using the Cochran Q statistic and the inconsistency index (I(2)), and publication bias was evaluated using the Egger test. Effects of demographic (age), clinical, and vendor variables were assessed in a metaregression. RESULTS: The search identified 2,325 children from 43 data sets. The reported normal mean values of GLS among the studies varied from -16.7% to -23.6% (mean, -20.2%; 95% CI, -19.5% to -20.8%), GCS varied from -12.9% to -31.4% (mean, -22.3%; 95% CI, -19.9% to -24.6%), and GRS varied from 33.9% to 54.5% (mean, 45.2%; 95% CI, 38.3% to 51.7%). Twenty-six studies reported longitudinal strain only from the apical four-chamber view, with a mean of -20.4% (95% CI, -19.8% to -21.7%). Twenty-three studies reported circumferential strain (mean, -20.3%; 95% CI, -19.4% to -21.2%) and radial strain (mean, 46.7%; 95% CI, 42.3% to 51.1%) from the short-axis view at the midventricular level. A significant apex-to-base segmental longitudinal strain gradient (P < .01) was observed in the LV free wall. There was significant between-study heterogeneity and inconsistency (I(2) > 94% and P < .001 for each strain measure), which was not explained by age, gender, body surface area, blood pressure, heart rate, frame rate, frame rate/heart rate ratio, tissue-tracking methodology, location of reported strain value along the strain curve, ultrasound equipment, or software. The metaregression showed that these effects were not significant determinants of variations among normal ranges of strain values. There was no evidence of publication bias (P = .40). CONCLUSIONS: This study defines reference values of 2DSTE-derived LV strain in children on the basis of a meta-analysis. In healthy children, mean LV GLS was -20.2% (95% CI, -19.5% to -20.8%), mean GCS was -22.3% (95% CI, -19.9% to -24.6%), and mean GRS was 45.2% (95% CI, 38.3% to 51.7%). LV segmental longitudinal strain has a stable apex-to-base gradient that is preserved throughout maturation. Although variations among different reference ranges in this meta-analysis were not dependent on differences in demographic, clinical, or vendor parameters, age- and vendor-specific referenced ranges were established as well.


Assuntos
Envelhecimento/fisiologia , Ecocardiografia/normas , Módulo de Elasticidade/fisiologia , Técnicas de Imagem por Elasticidade/normas , Ventrículos do Coração/diagnóstico por imagem , Função Ventricular Esquerda/fisiologia , Adolescente , Criança , Pré-Escolar , Ecocardiografia/estatística & dados numéricos , Técnicas de Imagem por Elasticidade/estatística & dados numéricos , Feminino , Humanos , Lactente , Recém-Nascido , Internacionalidade , Masculino , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
7.
Ultrasound Med Biol ; 42(2): 607-18, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26589530

RESUMO

As a step toward the goal of relating changes in underlying myocardial structure to observed altered cardiac function in the hearts of individual patients, this study addresses the feasibility of creating echocardiography-derived maps of regional myocardial fiber structure for entire, intact, excised sheep hearts. Backscatter data were obtained from apical echocardiographic images acquired with a clinical ultrasonic imaging system and used to determine local fiber orientations in each of seven hearts. Systematic acquisition across the entire heart volume provided information sufficient to give a complete map for each heart. Results from the echocardiography-derived fiber maps compare favorably with corresponding results derived from diffusion tensor magnetic resonance imaging. The results of this study provide evidence of the feasibility of using echocardiographic methods to generate individualized whole heart fiber maps for patients.


Assuntos
Algoritmos , Ecocardiografia Tridimensional/métodos , Interpretação de Imagem Assistida por Computador/métodos , Miócitos Cardíacos/diagnóstico por imagem , Miofibrilas/diagnóstico por imagem , Animais , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ovinos
8.
Echocardiography ; 33(4): 537-45, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26593856

RESUMO

OBJECTIVE: The purpose of this study was to determine whether resting myocardial deformation and rotation may be altered in diabetic patients with significant epicardial coronary artery disease (CAD) with normal left ventricular ejection fraction. DESIGN: A prospective observational study. SETTING: Diagnosis of epicardial CAD in patients with diabetes. PATIENTS AND METHODS: Eighty-four patients with diabetes suspected of epicardial CAD scheduled for cardiac catheterization had a resting echocardiogram performed prior to their procedure. Echocardiographic measurements were compared between patients with and without significant epicardial CAD as determined by cardiac catheterization. MAIN OUTCOME MEASURES: Measurement of longitudinal strain, strain rate, apical rotation, and rotation rate, using speckle tracking echocardiography. RESULTS: Eighty-four patients were studied, 39 (46.4%) of whom had significant epicardial CAD. Global peak systolic apical rotation was significantly increased (14.9 ± 5.1 vs. 11.0 ± 4.8 degrees, P < 0.001) in patients with epicardial CAD along with faster peak systolic apical rotation rate (90.4 ± 29 vs. 68.1 ± 22.2 degrees/sec, P < 0.001). These findings were further confirmed through multivariate logistic regression analysis (global peak systolic apical rotation OR = 1.17, P = 0.004 and peak systolic apical rotation rate OR = 1.05, P < 0.001). CONCLUSIONS: Patients with diabetes with significant epicardial CAD and normal LVEF exhibit an increase in peak systolic apical counterclockwise rotation and rotation rate detected by echocardiography, suggesting that significant epicardial CAD and its associated myocardial effects in patients with diabetes may be detected noninvasively at rest.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/epidemiologia , Complicações do Diabetes/diagnóstico por imagem , Complicações do Diabetes/epidemiologia , Ecocardiografia/estatística & dados numéricos , Ventrículos do Coração/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Comorbidade , Ecocardiografia/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Reprodutibilidade dos Testes , Fatores de Risco , Rotação , Sensibilidade e Especificidade , Estados Unidos/epidemiologia
9.
J Acoust Soc Am ; 138(2): 594-604, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26328678

RESUMO

Conventional, Bayesian, and the modified least-squares Prony's plus curve-fitting (MLSP + CF) methods were applied to data acquired using 1 MHz center frequency, broadband transducers on a single equine cancellous bone specimen that was systematically shortened from 11.8 mm down to 0.5 mm for a total of 24 sample thicknesses. Due to overlapping fast and slow waves, conventional analysis methods were restricted to data from sample thicknesses ranging from 11.8 mm to 6.0 mm. In contrast, Bayesian and MLSP + CF methods successfully separated fast and slow waves and provided reliable estimates of the ultrasonic properties of fast and slow waves for sample thicknesses ranging from 11.8 mm down to 3.5 mm. Comparisons of the three methods were carried out for phase velocity at the center frequency and the slope of the attenuation coefficient for the fast and slow waves. Good agreement among the three methods was also observed for average signal loss at the center frequency. The Bayesian and MLSP + CF approaches were able to separate the fast and slow waves and provide good estimates of the fast and slow wave properties even when the two wave modes overlapped in both time and frequency domains making conventional analysis methods unreliable.


Assuntos
Teorema de Bayes , Condução Óssea/fisiologia , Cavalos/fisiologia , Análise dos Mínimos Quadrados , Acústica , Algoritmos , Animais , Cavalos/anatomia & histologia , Porosidade , Ondas de Rádio , Rádio (Anatomia)/ultraestrutura , Som , Ultrassom
10.
Clin Nutr ESPEN ; 10(4): e140-e146, 2015 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-26273702

RESUMO

BACKGROUND: Despite the success of combination antiretroviral therapy (cART) for the prevention of mother to child transmission of HIV, infants exposed to cART in utero frequently are born smaller and have mild cardiac abnormalities. The mechanisms responsible for lower birth weight and cardiac abnormalities in children exposed to cART are unclear but could be related to dysregulation of maternal amino acid metabolism during pregnancy. Previous data in HIV(-) women have shown a relationship between abnormal maternal protein metabolism during pregnancy and low infant birth weight and animal data demonstrate a relationship between altered maternal protein metabolism and increased risk for offspring cardiovascular abnormalities. OBJECTIVE: The objectives of this study were to: characterize post-absorptive maternal leucine kinetics during late pregnancy andexamine the relationships between maternal leucine kinetics and offspring birth weight and cardiac function. DESIGN: Post-absorptive maternal leucine kinetics (evaluated by using stable isotope tracer methodology) in 16 HIV(+) women receiving cART and 14 HIV(-) US women during the 3rd trimester of pregnancy were compared. Relationships between post-absorptive maternal leucine kinetics, cardiac function (echocardiography) and birth weight were statistically examined. RESULTS: Maternal plasma leucine concentration (HIV(-): 82.8 ± 10.7 vs. HIV(+): 72.3 ± 13.5 µM, p=0.06) and leucine oxidation rate (HIV(-): 6.1 ± 1.6 vs. HIV(+): 4.9 ± 1.8 µmol/kgBW/min, p=0.03) were lower in HIV+ women compared to controls. Total leucine turnover rate, non-oxidative leucine disposal rate and post-absorptive maternal glucose and palmitate kinetics did not differ between groups. Left ventricular fractional shortening tended to be lower in children born to HIV(+) compared to controls (HIV(-): 42 ± 1 vs. HIV+: 36 ± 5 %, p=0.08) and associated with lower maternal plasma leucine concentration (r= 0.43, p=0.08). CONCLUSIONS: Preliminary results indicate that post-absorptive maternal leucine metabolism during late pregnancy is mildly altered in HIV+ US women taking cART. The clinical significance of maternal leucine metabolism on adverse infant outcomes is unclear and should be further explored in more expansive studies.

11.
J Am Soc Echocardiogr ; 28(5): 559-69, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25753503

RESUMO

BACKGROUND: Right ventricular (RV) fractional area of change (FAC) is a quantitative two-dimensional echocardiographic measurement of RV function. RV FAC expresses the percentage change in the RV chamber area between end-diastole (RV end-diastolic area [RVEDA]) to end-systole (RV end-systolic area [RVESA]). The objectives of this study were to determine the maturational (age- and weight-related) changes in RV FAC and RV areas and to establish reference values in healthy preterm and term neonates. METHODS: A prospective longitudinal study was conducted in 115 preterm infants (23-28 weeks' gestational age at birth, 500-1,500 g). RV FAC was measured at 24 hours of age, 72 hours of age, and 32 and 36 weeks' postmenstrual age (PMA). The maturational patterns of RVEDA, RVESA, and RV FAC were compared with those in 60 healthy full-term infants in a cross-sectional study (≥37 weeks, 3.5 ± 1 kg), who underwent echocardiography at birth (n = 25) and 1 month of age (n = 35). RVEDA and RVESA were traced in the RV-focused apical four-chamber view, and FAC was calculated using the formula 100 × [(RVEDA - RVESA)/RVEDA)]. Premature infants who developed chronic lung disease or had clinically and hemodynamically significant patent ductus arteriosus were excluded (n = 55) from the reference values. Intra- and interobserver reproducibility analysis was performed. RESULTS: RV FAC ranged from 26% at birth to 35% by 36 weeks' PMA in preterm infants (n = 60) and increased almost 2 times faster in the first month of age compared with healthy term infants (n = 60). Similarly, RVEDA and RVESA increased throughout maturation in both term and preterm infants. RV FAC and RV areas were correlated with weight (r = 0.81, P < .001) but were independent of gestational age at birth (r = 0.3, P = .45). RVEDA and RVESA were correlated with PMA in weeks (r = 0.81, P < .001). RV FAC trended lower in preterm infants with bronchopulmonary dysplasia (P = .04) but was not correlated with size of patent ductus arteriosus (P = .56). There was no difference in RV FAC based on gender or need for mechanical ventilation. CONCLUSIONS: This study establishes reference values of RV areas (RVEDA and RVESA) and RV FAC in healthy term and preterm infants and tracks their maturational changes during postnatal development. These measures increase from birth to 36 weeks' PMA, and this is reflective of the postnatal cardiac growth as a contributor to the maturation of cardiac function These measures are also linearly associated with increasing weight throughout maturation. This study suggests that two-dimensional RV FAC can be used as a complementary modality to assess global RV systolic function in neonates and facilitates its incorporation into clinical pediatric and neonatal guidelines.


Assuntos
Permeabilidade do Canal Arterial/fisiopatologia , Ecocardiografia/métodos , Recém-Nascido Prematuro/fisiologia , Volume Sistólico/fisiologia , Função Ventricular Direita/fisiologia , Permeabilidade do Canal Arterial/diagnóstico por imagem , Feminino , Seguimentos , Idade Gestacional , Ventrículos do Coração/diagnóstico por imagem , Humanos , Recém-Nascido , Masculino , Estudos Prospectivos , Valores de Referência , Reprodutibilidade dos Testes
12.
J Pediatr ; 166(3): 660-5, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25556013

RESUMO

OBJECTIVES: To test our hypothesis that obese adolescents have left ventricular (LV) dysfunction and remodeling that are associated with markers of cardiovascular risk and insulin resistance (IR). STUDY DESIGN: In a cross-sectional study of 44 obese and 14 lean age-, sex-, Tanner stage-, and race-matched adolescents, IR, markers of cardiovascular risks, conventional and 2-dimensional speckle tracking echocardiography measures of LV function and structure were evaluated and compared. RESULTS: The obese adolescents had significantly increased body mass index Z-score, systolic blood pressure, fasting insulin, IR, and atherogenic lipids compared with the lean adolescents. A subgroup of obese adolescents had LV remodeling characterized by significantly increased LV mass index (g/m(2.7)) and relative wall thickness. Almost all obese adolescents had LV dysfunction with peak LV global longitudinal strain (GLS, %), systolic GLS rate (GLSR, %/s), and early diastolic GLSR significantly lower than in lean adolescents and in the normal pediatric population. Body mass index Z-score predicted LV remodeling (LV mass index [R(2) = 0.34] and relative wall thickness [R(2) 0.10]), and peak LV GLS (R(2) 0.15), and along with systolic blood pressure, predicted systolic GLSR (R(2) 0.16); (P ≤ .01 for all). Fasting insulin predicted early diastolic GLSR (R(2) 0.17, P ≤ .01). CONCLUSIONS: Obese adolescents have subclinical ventricular dysfunction associated with the severity of obesity, increased systolic blood pressure, and IR. Ventricular remodeling is present in a subgroup of obese adolescents in association with the severity of obesity. These findings suggest that obesity may have an early impact on the cardiovascular health of obese adolescents.


Assuntos
Biomarcadores/sangue , Índice de Massa Corporal , Resistência à Insulina , Obesidade Infantil/complicações , Disfunção Ventricular Esquerda/etiologia , Adolescente , Doenças Cardiovasculares/sangue , Doenças Cardiovasculares/epidemiologia , Doenças Cardiovasculares/etiologia , Criança , Estudos Transversais , Ecocardiografia , Feminino , Humanos , Incidência , Masculino , Obesidade Infantil/sangue , Obesidade Infantil/epidemiologia , Estudos Retrospectivos , Fatores de Risco , Estados Unidos/epidemiologia , Disfunção Ventricular Esquerda/epidemiologia , Disfunção Ventricular Esquerda/fisiopatologia
13.
Echocardiography ; 32(5): 839-47, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25109389

RESUMO

BACKGROUND: Frame rate (FR) of image acquisition is an important determinant of the reliability of 2-dimensional speckle tracking echocardiography (2DSTE)-derived myocardial strain. Premature infants have relatively high heart rates (HR). The aim was to analyze the effects of varying FR on the reproducibility of 2DSTE-derived right ventricle (RV) and left ventricle (LV) longitudinal strain (LS) and strain rate (LSR) in premature infants. METHODS: RV and LV LS and LSR were measured by 2DSTE in the apical four-chamber view in 20 premature infants (26 ± 1 weeks) with HR 163 ± 13 bpm. For each subject, 4 sets of cine loops were acquired at FR of <90, 90-110, 110-130, and >130 frames/sec. Two observers measured LS and LSR. Inter- and intra-observer reproducibility was assessed using Bland-Altman analysis, coefficient of variation, and linear regression. RESULTS: Intra-observer reproducibility for RV and LV LS was higher at FR >110 frames/sec, and optimum at FR >130 frames/sec. The highest inter-observer reproducibility for RV and LV LS were at FR >130 and >110 frames/s, respectively. The highest reproducibility for RV and LV systolic and early diastolic LSR was at FR >110 frames/sec. FR/HR ratio >0.7 frames/sec per bpm yielded optimum reproducibility for RV and LV deformation imaging. CONCLUSIONS: The reliability of 2DSTE-derived RV and LV deformation imaging in premature infants is affected by the FR of image acquisition. Reproducibility is most robust when cine loops are obtained with FR/HR ratio between 0.7 and 0.9 frames/sec per bpm, which likely results from optimal myocardial speckle tracking and mechanical event timing.


Assuntos
Cardiopatias Congênitas/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Recém-Nascido Prematuro , Feminino , Humanos , Recém-Nascido , Masculino , Variações Dependentes do Observador , Estudos Prospectivos , Reprodutibilidade dos Testes , Ultrassonografia
14.
Ultrasound Med Biol ; 40(12): 2777-85, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25308949

RESUMO

The aims of the study were, first, to assess whether myocardial ultrasound tissue characterization (UTC) in Becker muscular dystrophy (BMD) can be used to differentiate between patients with deletions and those without deletions; and second, to determine whether UTC is helpful in diagnosing the evolution of left ventricular dysfunction, a precursor of dilated cardiomyopathy. Both cyclic variation of integrated backscatter and calibrated integrated backscatter (cIBS) were assessed in 87 patients with BMD and 70 controls. The average follow-up in BMD patients was 48 ± 12 mo. UTC analysis was repeated only in a subgroup of 40 BMD patients randomly selected from the larger overall group (15 with and 25 without left ventricular dysfunction). Discrimination between BMD patients with and without dystrophin gene deletion was not possible on the basis of UTC data: average cvIBS was 5.2 ± 1.2 and 5.5 ± 1.4 dB, and average cIBS was 29.9 ± 4.7 and 29.6 ± 5.8, respectively, significantly different (p < 0.001) only from controls (8.6 ± 0.5 and 24.6 ± 1.2 dB). In patients developing left ventricular dysfunction during follow-up, cIBS increased to 31.3 ± 5.4 dB, but not significantly (p = 0.08). The highest cIBS values (34.6 ± 5.3 dB, p < 0.09 vs. baseline, p < 0.01 vs BMD patients without left ventricular dysfunction) were seen in the presence of severe left ventricular dysfunction. Multivariate statistics indicated that an absolute change of 6 dB in cIBS is associated with a high probability of left ventricular dysfunction. UTC analysis does not differentiate BMD patients with or without dystrophin gene deletion, but may be useful in indexing left ventricular dysfunction during follow-up.


Assuntos
Cardiomiopatia Dilatada/diagnóstico por imagem , Cardiomiopatia Dilatada/genética , Distrofina/genética , Distrofia Muscular de Duchenne/diagnóstico por imagem , Distrofia Muscular de Duchenne/genética , Volume Sistólico/genética , Ultrassonografia/métodos , Adolescente , Adulto , Criança , Pré-Escolar , Feminino , Predisposição Genética para Doença/genética , Genótipo , Humanos , Masculino , Mutação Puntual/genética , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
15.
J Am Soc Echocardiogr ; 27(5): 549-60, e3, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24582163

RESUMO

BACKGROUND: Establishment of the range of normal values and associated variations of two-dimensional (2D) speckle-tracking echocardiography (STE)-derived right ventricular (RV) strain is a prerequisite for its routine clinical application in children. The objectives of this study were to perform a meta-analysis of normal ranges of RV longitudinal strain measurements derived by 2D STE in children and to identify confounders that may contribute to differences in reported measures. METHODS: A systematic review was conducted in PubMed, Embase, Scopus, the Cochrane Central Register of Controlled Trials, and ClinicalTrials.gov. Search hedges were created to cover the concepts of pediatrics, STE, and the right heart ventricle. Two investigators independently identified and included studies if they reported the 2D STE-derived RV strain measure RV peak global longitudinal strain, peak global longitudinal systolic strain rate, peak global longitudinal early diastolic strain rate, peak global longitudinal late diastolic strain rate, or segmental longitudinal strain at the apical, middle, and basal ventricular levels in healthy children. Quality and reporting of the studies were assessed. The weighted mean was estimated using random effects with 95% confidence intervals (CIs), heterogeneity was assessed using Cochran's Q statistic and the inconsistency index (I(2)), and publication bias was evaluated using funnel plots and Egger's test. Effects of demographic, clinical, equipment, and software variables were assessed in a metaregression. RESULTS: The search identified 226 children from 10 studies. The reported normal mean values of peak global longitudinal strain among the studies varied from -20.80% to -34.10% (mean, -29.03%; 95% CI, -31.52% to -26.54%), peak global longitudinal systolic strain rate varied from -1.30 to -2.40 sec(-1) (mean, -1.88 sec(-1); 95% CI, -2.10 to -1.59 sec(-1)), peak global longitudinal early diastolic strain rate ranged from 1.7 to 2.69 sec(-1) (mean, 2.34 sec(-1); 95% CI, 2.00 to 2.67 sec(-1)), and peak global longitudinal late diastolic strain rate ranged from 1.00 to 1.30 sec(-1) (mean, 1.18 sec(-1); 95% CI, 1.04 to 1.33 sec(-1)). A significant base-to-apex segmental strain gradient (P < .05) was observed in the RV free wall. There was significant between-study heterogeneity and inconsistency (I(2) > 88% and P < .01 for each strain measure), which was not explained by age, gender, body surface area, heart rate, frame rate, tissue-tracking methodology, equipment, or software. The metaregression showed that these effects were not significant determinants of variations among normal ranges of strain values. There was no evidence of publication bias (P = .59). CONCLUSIONS: This study is the first to define normal values of 2D STE-derived RV strain in children on the basis of a meta-analysis. The normal mean value in children for RV global strain is -29.03% (95% CI, -31.52% to -26.54%). The normal mean value for RV global systolic strain rate is -1.88 sec(-1) (95% CI, -2.10 to -1.59 sec(-1)). RV segmental strain has a stable base-to-apex gradient that highlights the dominance of deep longitudinal layers of the right ventricle that are aligned base to apex. Variations among different normal ranges did not appear to be dependent on differences in demographic, clinical, or equipment parameters in this meta-analysis. All of the eligible studies used equipment and software from one manufacturer (GE Healthcare).


Assuntos
Ecocardiografia/estatística & dados numéricos , Ecocardiografia/normas , Técnicas de Imagem por Elasticidade/estatística & dados numéricos , Técnicas de Imagem por Elasticidade/normas , Ventrículos do Coração/diagnóstico por imagem , Função Ventricular Direita/fisiologia , Adolescente , Criança , Pré-Escolar , Diástole/fisiologia , Módulo de Elasticidade/fisiologia , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Sístole/fisiologia , Adulto Jovem
16.
J Am Soc Echocardiogr ; 27(2): 163-71, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24183542

RESUMO

BACKGROUND: Doppler echocardiography (DE) is widely used as a surrogate for right heart catheterization (RHC), the gold standard, to assess and monitor elevated right heart pressure in children. However, its accuracy has not been prospectively validated in children. The objectives of this study were to evaluate the accuracy of DE in predicting simultaneously measured right ventricular (RV) pressure by RHC in pediatric patients and to determine if the degree of RV hypertension affects the accuracy of DE in assessing right heart pressure. METHODS: Eighty children (age range, 0-17.9 years; median age, 5.5 years) with two-ventricle physiology and a wide range of right heart pressures underwent simultaneous DE and RHC. The pressure gradient between the right ventricle and the right atrium was directly measured by RHC and simultaneously estimated by DE using tricuspid regurgitation. Patients were then grouped on the basis of RHC-measured RV systolic pressure (RVSP): group 1 (n = 43), with RVSP < 1/2 systemic systolic blood pressure (SBP); group 2 (n = 37), with RVSP ≥ 1/2 SBP; group 3 (n = 56), with RVSP < 2/3 SBP; and group 4 (n = 24), with RVSP ≥ 2/3 SBP. Correlation and Bland-Altman analyses were performed on all groups. Accuracy was predefined as 95% limits of agreement within ±10 mm Hg. RESULTS: Despite a reasonable correlation between DE and RHC in all groups, there was poor agreement between techniques as RVSP/SBP increased. DE was inaccurate in one of 43 patients in group 1 (2%) versus nine of 37 in group 2 (24%) and was inaccurate in one of 56 patients in group 3 (2%) versus eight of 24 in group 4 (33%). Overestimation and underestimation occurred equally in all groups. CONCLUSION: DE inaccurately estimates RV pressure in children with elevated right heart pressure. It should not be relied on as the sole method of assessing right heart hemodynamics in children with RV hypertension.


Assuntos
Determinação da Pressão Arterial/métodos , Determinação da Pressão Arterial/normas , Ecocardiografia Doppler , Cardiopatias/complicações , Hipertensão/diagnóstico por imagem , Hipertensão/fisiopatologia , Pressão Ventricular , Adolescente , Cateterismo Cardíaco , Criança , Pré-Escolar , Precisão da Medição Dimensional , Feminino , Humanos , Hipertensão/etiologia , Lactente , Masculino , Erros Médicos , Valor Preditivo dos Testes , Estudos Prospectivos , Curva ROC , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Função Ventricular Direita/fisiologia
17.
J Am Soc Echocardiogr ; 26(10): 1201-1213, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23880052

RESUMO

BACKGROUND: Right ventricular (RV) systolic function is an important prognostic determinant of cardiopulmonary pathologies in premature infants. Measurements of dominant RV longitudinal deformation are likely to provide a sensitive measure of RV function. An approach for image acquisition and postacquisition processing is needed for reliable and reproducible measurements of myocardial deformation by two-dimensional (2D) speckle-tracking echocardiography. The aims of this study were to determine the feasibility and reproducibility of 2D speckle-tracking echocardiographic measurement of RV peak global longitudinal strain (pGLS) and peak global longitudinal strain rate in premature infants and to establish methods for acquiring and analyzing strain. METHODS: The study was designed in two phases: (1) a training phase to develop methods of image acquisition and postprocessing in a cohort of 30 premature infants (born at 28 ± 1 weeks) and (2) a study phase to prospectively test in a separate cohort of 50 premature infants (born at 27 ± 1 weeks) if the methods improved the feasibility and reproducibility of RV pGLS and peak global longitudinal strain rate measurements to a clinically significant level, assessed using Bland-Altman analysis (bias, limits of agreement, coefficient of variation, and intraclass correlation coefficient). RESULTS: Strain imaging was feasible from 84% of the acquisitions using the methods developed for optimal speckle brightness and frame rate for RV-focused image acquisition. There was high intraobserver (bias, 3%; 95% limits of agreement, -1.6 to +1.6; coefficient of variation, 2.7%; intraclass correlation coefficient, 0.97; P = .02) and interobserver (bias, 7%; 95% limits of agreement, -4.8 to +4.73; coefficient of variation, 3.9%; intraclass correlation coefficient, 0.93; P < .05) reproducibility, with excellent linear correlation between the two pGLS measurements (r = 0.97 [P < .01] and r = 0.93 [P < .05], respectively). CONCLUSIONS: This study demonstrates high clinical feasibility and reproducibility of RV pGLS and RV peak global longitudinal strain rate measurements by 2D speckle-tracking echocardiography in premature infants and offers methods for image acquisition and data analysis for systolic strain imaging that can provide a reliable assessment of global RV function.


Assuntos
Ecocardiografia/métodos , Ventrículos do Coração/diagnóstico por imagem , Recém-Nascido Prematuro , Estudos de Viabilidade , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Recém-Nascido , Masculino , Prognóstico , Reprodutibilidade dos Testes , Sístole/fisiologia
18.
J Acoust Soc Am ; 133(3): 1399-403, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23464011

RESUMO

The goal of this study is to contribute to the physics underlying the material properties of suspensions that exhibit shear thickening through the ultrasonic characterization of suspensions of cornstarch in a density-matched solution. Ultrasonic measurements at frequencies in the range of 4 to 8 MHz of the speed of sound and the frequency-dependent attenuation properties are reported for concentrations of cornstarch in a density-matched aqueous (cesium chloride brine) suspension, ranging up to 40% cornstarch. The speed of sound is found to range from 1483 ± 10 m/s in pure brine to 1765 ± 9 m/s in the 40% cornstarch suspension. The bulk modulus of a granule of cornstarch is inferred to be 1.2(± 0.1) × 10(10) Pa. The attenuation coefficient at 5 MHz increases from essentially zero in brine to 12.0 ± 1.2 dB/cm at 40% cornstarch.


Assuntos
Som , Amido/química , Ultrassom/métodos , Césio/química , Cloretos/química , Módulo de Elasticidade , Modelos Teóricos , Movimento (Física) , Processamento de Sinais Assistido por Computador , Fatores de Tempo
19.
Muscle Nerve ; 47(2): 246-54, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23169008

RESUMO

INTRODUCTION: We studied ultrasound features of muscle after nerve injury. METHODS: We evaluated ultrasound measurements of muscle thickness and backscatter in injured and contralateral uninjured elbow flexors of 51 children with newborn brachial plexus palsy (NBPP) and compared the results to elbow flexor function (Active Movement Scale), defined as normal, moderate, or severe. RESULTS: Compared with uninjured limbs, muscle in injured arms was 15% thinner with severe impairment, 17% thicker with moderate impairment, and no different with normal function. Relative to uninjured limbs, moderately impaired muscle was thicker than both severely impaired and normal strength muscle. Backscatter was higher in injured than in uninjured limbs regardless of function. In 17 patients with sequential measures, muscle thickness, but not backscatter, increased with function over time. CONCLUSIONS: Muscle thickness differentiates moderate from severe impairment after NBPP and increases with recovery over time. Muscle backscatter identifies prior injury regardless of function.


Assuntos
Neuropatias do Plexo Braquial/congênito , Neuropatias do Plexo Braquial/diagnóstico por imagem , Plexo Braquial/diagnóstico por imagem , Músculo Esquelético/diagnóstico por imagem , Plexo Braquial/fisiopatologia , Neuropatias do Plexo Braquial/fisiopatologia , Criança , Pré-Escolar , Cotovelo/fisiologia , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Movimento/fisiologia , Músculo Esquelético/fisiopatologia , Amplitude de Movimento Articular/fisiologia , Índice de Gravidade de Doença , Ultrassonografia
20.
J Pediatr ; 162(6): 1160-8, 1168.e1, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23260104

RESUMO

OBJECTIVE: To determine the association among nonalcoholic fatty liver disease (NAFLD), metabolic function, and cardiac function in obese adolescents. STUDY DESIGN: Intrahepatic triglyceride (IHTG) content (magnetic resonance spectroscopy), insulin sensitivity and ß-cell function (5-hour oral glucose tolerance test with mathematical modeling), and left ventricular function (speckle tracking echocardiography) were determined in 3 groups of age, sex, and Tanner matched adolescents: (1) lean (n=14, body mass index [BMI]=20±2 kg/m2); (2) obese with normal (2.5%) IHTG content (n=15, BMI=35±3 kg/m2); and (3) obese with increased (8.7%) IHTG content (n=15, BMI=37±6 kg/m2). RESULTS: The disposition index (ß-cell function) and insulin sensitivity index were ∼45% and ∼70% lower, respectively, and whole body insulin resistance, calculated by homeostasis model of assessment-insulin resistance (HOMA-IR), was ∼60% greater, in obese than in lean subjects, and ∼30% and ∼50% lower and ∼150% greater, respectively, in obese subjects with NAFLD than those without NAFLD (P<.05 for all). Left ventricular global longitudinal systolic strain and early diastolic strain rates were significantly decreased in obese than in lean subjects, and in obese subjects with NAFLD than those without NAFLD (P<.05 for all), and were independently associated with HOMA-IR (ß=0.634). IHTG content was the only significant independent determinant of insulin sensitivity index (ß=-0.770), disposition index (ß=-0.651), and HOMA-IR (ß=0.738). CONCLUSIONS: These findings demonstrate that the presence of NAFLD in otherwise asymptomatic obese adolescents is an early marker of cardiac dysfunction.


Assuntos
Fígado Gorduroso/fisiopatologia , Ventrículos do Coração/patologia , Ventrículos do Coração/fisiopatologia , Fígado/fisiopatologia , Obesidade/complicações , Adolescente , Índice de Massa Corporal , Estudos Transversais , Fígado Gorduroso/metabolismo , Feminino , Humanos , Resistência à Insulina , Fígado/metabolismo , Espectroscopia de Ressonância Magnética , Masculino , Hepatopatia Gordurosa não Alcoólica , Obesidade/metabolismo , Obesidade/fisiopatologia , Triglicerídeos/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA