Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
IEEE Trans Biomed Eng ; PP2024 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-39141476

RESUMO

OBJECTIVE: Highly-undersampled, dynamic MRI reconstruction, particularly in multi-coil scenarios, is a challenging inverse problem. Unrolled networks achieve state-of-the-art performance in MRI reconstruction but suffer from long training times and extensive GPU memory cost. METHODS: In this work, we propose a novel training strategy for IMplicit UNrolled NEtworks (IMUNNE) for highly-undersampled, multi-coil dynamic MRI reconstruction. It formulates the MRI reconstruction problem as an implicit fixed-point equation and leverages gradient approximation for backpropagation, enabling training of deep architectures with fixed memory cost. This study represents the first application of implicit network theory in the context of real-time cine MRI. The proposed method is evaluated using a prospectively undersampled, real-time cine dataset using radial k-space sampling, comprising balanced steady-state free precession (b-SSFP) readouts. Experiments include a hyperparameter search, head-to-head comparisons with a complex U-Net (CU-Net) and an alternating unrolled network (Alt-UN), and an analysis of robustness under noise perturbations; peak signal-to-noise ratio, structural similarity index, normalized root mean-square error, spatio-temporal entropic difference, and a blur metric were used. RESULTS: IMUNNE produced significantly and slightly better image quality compared to CU-Net and Alt-UN, respectively. Compared with Alt-UN, IMUNNE significantly reduced training and inference times, making it a promising approach for highly-accelerated, multi-coil real-time cine MRI reconstruction. CONCLUSION: IMUNNE strategy successfully applies unrolled networks to image reconstruction of highly-accelerated, real-time radial cine MRI. SIGNIFICANCE: Implicit training enables rapid, high-quality, and cost-effective CMR exams by reducing training and inference times and lowering memory cost associated with advanced reconstruction methods.

2.
Radiol Cardiothorac Imaging ; 6(1): e230107, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38358330

RESUMO

Purpose To achieve ultra-high temporal resolution (approximately 20 msec) in free-breathing, real-time cardiac cine MRI using golden-angle radial sparse parallel (GRASP) reconstruction amplified with view sharing (VS) and k-space-weighted image contrast (KWIC) filtering. Materials and Methods Fourteen pediatric patients with congenital heart disease (mean age [SD], 9 years ± 2; 13 male) and 10 adult patients with arrhythmia (mean age, 62 years ± 8; nine male) who underwent both standard breath-hold cine and free-breathing real-time cine using GRASP were retrospectively identified. To achieve high temporal resolution, each time frame was reconstructed using six radial spokes, corresponding to acceleration factors ranging from 24 to 32. To compensate for loss in spatial resolution resulting from over-regularization in GRASP, VS and KWIC filtering were incorporated. The blur metric, visual image quality scores, and biventricular parameters were compared between clinical and real-time cine images. Results In pediatric patients, the incorporation of VS and KWIC into GRASP (ie, GRASP + VS + KWIC) produced significantly (P < .05) sharper x-y-t (blur metric: 0.36 ± 0.03, 0.41 ± 0.03, 0.48 ± 0.03, respectively) and x-y-f (blur metric: 0.28 ± 0.02, 0.31 ± 0.03, 0.37 ± 0.03, respectively) component images compared with GRASP + VS and conventional GRASP. Only the noise score differed significantly between GRASP + VS + KWIC and clinical cine; all visual scores were above the clinically acceptable (3.0) cutoff point. Biventricular volumetric parameters strongly correlated (R2 > 0.85) between clinical and real-time cine images reconstructed with GRASP + VS + KWIC and were in good agreement (relative error < 6% for all parameters). In adult patients, the visual scores of all categories were significantly lower (P < .05) for clinical cine compared with real-time cine with GRASP + VS + KWIC, except for noise (P = .08). Conclusion Incorporating VS and KWIC filtering into GRASP reconstruction enables ultra-high temporal resolution (approximately 20 msec) without significant loss in spatial resolution. Keywords: Cine, View Sharing, k-Space-weighted Image Contrast Filtering, Radial k-Space, Pediatrics, Arrhythmia, GRASP, Compressed Sensing, Real-Time, Free-Breathing Supplemental material is available for this article. © RSNA, 2024.


Assuntos
Imagem Cinética por Ressonância Magnética , Imageamento por Ressonância Magnética , Adulto , Humanos , Masculino , Criança , Pessoa de Meia-Idade , Estudos Retrospectivos , Taquipneia , Hiperventilação , Arritmias Cardíacas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA