1.
Sensors (Basel) ; 13(4): 4714-23, 2013 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-23571672

RESUMO

A prototype of a clip-type pulsimeter equipped with a magnetic field-sensing semiconductor Hall sensor was developed. It has a permanent magnet attached in the "Chwan" position to the center of a radial artery. The clip-type pulsimeter is composed of a hardware system measuring voltage signals. To measure spatial pulse wave velocity (SPWV), the signal from the radial artery pulsimeter and that from the photoplethysmography (PPG) were simultaneously compared. The pulse wave data from a clinical test of 39 clinical participants (male:female = 25:14) with a mean age of 24.36 (±2.35) years was analyzed. The mean SPWV, which was simultaneously measured from the radial artery pulsimeter and PPG, was 0.8 m/s. We suggest the SPWV results were higher for men than women, because of the better vascularity of terminal tissue in men. The findings of this research may be useful for developing a biomedical signal storage device for a U-health-care system.


Assuntos
Fotopletismografia/instrumentação , Fotopletismografia/métodos , Análise de Onda de Pulso/instrumentação , Análise de Onda de Pulso/métodos , Eletrocardiografia , Feminino , Humanos , Masculino , Pulso Arterial , Artéria Radial/fisiologia , Processamento de Sinais Assistido por Computador , Adulto Jovem
2.
Sensors (Basel) ; 11(2): 1784-93, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-22319381

RESUMO

To measure precise blood pressure (BP) and pulse rate without using a cuff, we have developed an arterial pulsimeter consisting of a small, portable apparatus incorporating a Hall device. Regression analysis of the pulse wave measured during testing of the arterial pulsimeter was conducted using two equations of the BP algorithm. The estimated values of BP obtained by the cuffless arterial pulsimeter over 5 s were compared with values obtained using electronic or liquid mercury BP meters. The standard deviation between the estimated values and the measured values for systolic and diastolic BP were 8.3 and 4.9, respectively, which are close to the range of values of the BP International Standard. Detailed analysis of the pulse wave measured by the cuffless radial artery pulsimeter by detecting changes in the magnetic field can be used to develop a new diagnostic algorithm for BP, which can be applied to new medical apparatus such as the radial artery pulsimeter.


Assuntos
Artérias/fisiologia , Determinação da Pressão Arterial/instrumentação , Pressão Sanguínea/fisiologia , Magnetismo/instrumentação , Pulso Arterial/instrumentação , Algoritmos , Eletrônica , Humanos , Rádio (Anatomia)/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...