Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38652399

RESUMO

To enhance M-mode echocardiography's utility for measuring cardiac structures, we developed and evaluated an artificial intelligence (AI)-based automated analysis system for M-mode images through the aorta and left atrium [M-mode (Ao-LA)], and through the left ventricle [M-mode (LV)]. Our system, integrating two deep neural networks (DNN) for view classification and image segmentation, alongside an auto-measurement algorithm, was developed using 5,958 M-mode images [3,258 M-mode (LA-Ao), and 2,700 M-mode (LV)] drawn from a nationwide echocardiographic dataset collated from five tertiary hospitals. The performance of view classification and segmentation DNNs were evaluated on 594 M-mode images, while automatic measurement accuracy was tested on separate internal test set with 100 M-mode images as well as external test set with 280 images (140 sinus rhythm and 140 atrial fibrillation). Performance evaluation showed the view classification DNN's overall accuracy of 99.8% and segmentation DNN's Dice similarity coefficient of 94.3%. Within the internal test set, all automated measurements, including LA, Ao, and LV wall and cavity, resonated strongly with expert evaluations, exhibiting Pearson's correlation coefficients (PCCs) of 0.81-0.99. This performance persisted in the external test set for both sinus rhythm (PCC, 0.84-0.98) and atrial fibrillation (PCC, 0.70-0.97). Notably, automatic measurements, consistently offering multi-cardiac cycle readings, showcased a stronger correlation with the averaged multi-cycle manual measurements than with those of a single representative cycle. Our AI-based system for automatic M-mode echocardiographic analysis demonstrated excellent accuracy, reproducibility, and speed. This automated approach has the potential to improve efficiency and reduce variability in clinical practice.

2.
Yonsei Med J ; 65(5): 257-264, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38653564

RESUMO

PURPOSE: In a preclinical study using a swine myocardial infarction (MI) model, a delayed enhancement (DE)-multi-detector computed tomography (MDCT) scan was performed using a hybrid system alongside diagnostic invasive coronary angiography (ICA) without the additional use of a contrast agent, and demonstrated an excellent correlation in the infarct area compared with histopathologic specimens. In the present investigation, we evaluated the feasibility and diagnostic accuracy of a myocardial viability assessment by DE-MDCT using a hybrid system comprising ICA and MDCT alongside diagnostic ICA without the additional use of a contrast agent. MATERIALS AND METHODS: We prospectively enrolled 13 patients (median age: 67 years) with a previous MI (>6 months) scheduled to undergo ICA. All patients underwent cardiac magnetic resonance (CMR) imaging before diagnostic ICA. MDCT viability scans were performed concurrently with diagnostic ICA without the use of additional contrast. The total myocardial scar volume per patient and average transmurality per myocardial segment measured by DE-MDCT were compared with those from DE-CMR. RESULTS: The DE volume measured by MDCT showed an excellent correlation with the volume measured by CMR (r=0.986, p<0.0001). The transmurality per segment by MDCT was well-correlated with CMR (r=0.900, p<0.0001); the diagnostic performance of MDCT in differentiating non-viable from viable myocardium using a 50% transmurality criterion was good with a sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of 87.5%, 99.5%, 87.5%, 99.5%, and 99.1%, respectively. CONCLUSION: The feasibility of the DE-MDCT viability assessment acquired simultaneously with conventional ICA was proven in patients with chronic MI using DE-CMR as the reference standard.


Assuntos
Angiografia Coronária , Infarto do Miocárdio , Humanos , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/patologia , Idoso , Angiografia Coronária/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Prospectivos , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada Multidetectores/métodos
3.
Clin Orthop Surg ; 16(1): 73-85, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38304206

RESUMO

Background: Although many studies have been conducted on the association between the intercondylar notch size and the risk of anterior cruciate ligament (ACL) injury, few studies have examined its relationship with the condition after surgical treatment. Therefore, this study aimed to investigate the surgical outcomes of anatomical single-bundle ACL reconstruction according to intercondylar notch volumes. Methods: Medical records of patients who underwent anatomical single-bundle ACL reconstruction using a tibialis anterior allograft between 2015 and 2019 were retrospectively reviewed. For each sex, eligible patients were classified into two groups based on their percentile of intercondylar notch volumes, which were measured using postoperative three-dimensional computed tomography images (group S, ≤ 50th percentile of included patients; group L, > 50th percentile of included patients). Additional grouping was performed based on the group's percentiles of normalized values of intercondylar notch volumes to body heights. Between-group comparative analyses were performed on the perioperative data and surgical outcomes in both objective and subjective aspects. Results: One hundred patients were included in the study. For male patients, there were no differences in the overall surgical outcomes between groups, whereas group L showed a significantly greater knee anteroposterior (AP) laxity than group S at the final follow-up (p = 0.042 for the side-to-side differences [SSD] at the maximum manual force). Similarly, there were no differences in the female patients in the overall surgical results between the groups, whereas group L showed a significantly greater knee AP laxity at the final follow-up (p = 0.020 for the SSD at 134 N; p = 0.011 for the SSD at the maximum manual force). Additional analyses based on the normalized values of the intercondylar notch volume showed consistent results for male patients, and additional grouping for female patients was identical to the existing grouping. Conclusions: The surgical outcomes of anatomical single-bundle ACL reconstruction in patients with relatively small intercondylar notch volumes were comparable to those with large notch volumes, but rather showed favorable outcomes in postoperative knee AP laxity.


Assuntos
Lesões do Ligamento Cruzado Anterior , Reconstrução do Ligamento Cruzado Anterior , Humanos , Masculino , Feminino , Ligamento Cruzado Anterior/cirurgia , Estudos Retrospectivos , Fêmur/cirurgia , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Lesões do Ligamento Cruzado Anterior/diagnóstico por imagem , Lesões do Ligamento Cruzado Anterior/cirurgia , Reconstrução do Ligamento Cruzado Anterior/métodos , Resultado do Tratamento
4.
J Cardiovasc Comput Tomogr ; 18(3): 274-280, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38378314

RESUMO

BACKGROUND: Radiomics is expected to identify imaging features beyond the human eye. We investigated whether radiomics can identify coronary segments that will develop new atherosclerotic plaques on coronary computed tomography angiography (CCTA). METHODS: From a prospective multinational registry of patients with serial CCTA studies at ≥ 2-year intervals, segments without identifiable coronary plaque at baseline were selected and radiomic features were extracted. Cox models using clinical risk factors (Model 1), radiomic features (Model 2) and both clinical risk factors and radiomic features (Model 3) were constructed to predict the development of a coronary plaque, defined as total PV â€‹≥ â€‹1 â€‹mm3, at follow-up CCTA in each segment. RESULTS: In total, 9583 normal coronary segments were identified from 1162 patients (60.3 â€‹± â€‹9.2 years, 55.7% male) and divided 8:2 into training and test sets. At follow-up CCTA, 9.8% of the segments developed new coronary plaque. The predictive power of Models 1 and 2 was not different in both the training and test sets (C-index [95% confidence interval (CI)] of Model 1 vs. Model 2: 0.701 [0.690-0.712] vs. 0.699 [0.0.688-0.710] and 0.696 [0.671-0.725] vs. 0.0.691 [0.667-0.715], respectively, all p â€‹> â€‹0.05). The addition of radiomic features to clinical risk factors improved the predictive power of the Cox model in both the training and test sets (C-index [95% CI] of Model 3: 0.772 [0.762-0.781] and 0.767 [0.751-0.787], respectively, all p â€‹< â€‹00.0001 compared to Models 1 and 2). CONCLUSION: Radiomic features can improve the identification of segments that would develop new coronary atherosclerotic plaque. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov NCT0280341.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana , Vasos Coronários , Placa Aterosclerótica , Valor Preditivo dos Testes , Sistema de Registros , Humanos , Masculino , Doença da Artéria Coronariana/diagnóstico por imagem , Feminino , Pessoa de Meia-Idade , Idoso , Vasos Coronários/diagnóstico por imagem , Fatores de Tempo , Estudos Prospectivos , Progressão da Doença , Fatores de Risco , Medição de Risco , Interpretação de Imagem Radiográfica Assistida por Computador , Prognóstico , Reprodutibilidade dos Testes , Tomografia Computadorizada Multidetectores , Radiômica
5.
J Thorac Imaging ; 39(2): 119-126, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37889556

RESUMO

PURPOSE: To evaluate the ability of radiomics score (RS)-based machine learning to identify moderate to severe coronary artery calcium (CAC) on chest x-ray radiographs (CXR). MATERIALS AND METHODS: We included 559 patients who underwent a CAC scan with CXR obtained within 6 months and divided them into training (n = 391) and validation (n = 168) cohorts. We extracted radiomic features from annotated cardiac contours in the CXR images and developed an RS through feature selection with the least absolute shrinkage and selection operator regression in the training cohort. We evaluated the incremental value of the RS in predicting CAC scores when combined with basic clinical factor in the validation cohort. To predict a CAC score ≥100, we built an RS-based machine learning model using random forest; the input variables were age, sex, body mass index, and RS. RESULTS: The RS was the most prominent factor for the CAC score ≥100 predictions (odds ratio = 2.33; 95% confidence interval: 1.62-3.44; P < 0.001) compared with basic clinical factor. The machine learning model was tested in the validation cohort and showed an area under the receiver operating characteristic curve of 0.808 (95% confidence interval: 0.75-0.87) for a CAC score ≥100 predictions. CONCLUSIONS: The use of an RS-based machine learning model may have the potential as an imaging marker to screen patients with moderate to severe CAC scores before diagnostic imaging tests, and it may improve the pretest probability of detecting coronary artery disease in clinical practice.


Assuntos
Doença da Artéria Coronariana , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Radiômica , Raios X , Valor Preditivo dos Testes , Aprendizado de Máquina , Estudos Retrospectivos
6.
Comput Biol Med ; 159: 106931, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37116238

RESUMO

BACKGROUND: Most computed tomography (CT) denoising algorithms have been evaluated using image quality analysis (IQA) methods developed for natural image, which do not adequately capture the texture details in medical imaging. Radiomics is an emerging image analysis technique that extracts texture information to provide a more objective basis for medical imaging diagnostics, overcoming the subjective nature of traditional methods. By utilizing the difficulty of reproducing radiomics features under different imaging protocols, we can more accurately evaluate the performance of CT denoising algorithms. METHOD: We introduced radiomic feature reproducibility analysis as an evaluation metric for a denoising algorithm. Also, we proposed a low-dose CT denoising method based on a generative adversarial network (GAN), which outperformed well-known CT denoising methods. RESULTS: Although the proposed model produced excellent results visually, the traditional image assessment metrics such as peak signal-to-noise ratio and structural similarity failed to show distinctive performance differences between the proposed method and the conventional ones. However, radiomic feature reproducibility analysis provided a distinctive assessment of the CT denoising performance. Furthermore, radiomic feature reproducibility analysis allowed fine-tuning of the hyper-parameters of the GAN. CONCLUSION: We demonstrated that the well-tuned GAN architecture outperforms the well-known CT denoising methods. Our study is the first to introduce radiomics reproducibility analysis as an evaluation metric for CT denoising. We look forward that the study may bridge the gap between traditional objective and subjective evaluations in the clinical medical imaging field.


Assuntos
Algoritmos , Tomografia Computadorizada por Raios X , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos , Processamento de Imagem Assistida por Computador/métodos , Razão Sinal-Ruído
7.
Korean J Radiol ; 24(4): 294-304, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36907592

RESUMO

OBJECTIVE: We aimed to investigate whether image standardization using deep learning-based computed tomography (CT) image conversion would improve the performance of deep learning-based automated hepatic segmentation across various reconstruction methods. MATERIALS AND METHODS: We collected contrast-enhanced dual-energy CT of the abdomen that was obtained using various reconstruction methods, including filtered back projection, iterative reconstruction, optimum contrast, and monoenergetic images with 40, 60, and 80 keV. A deep learning based image conversion algorithm was developed to standardize the CT images using 142 CT examinations (128 for training and 14 for tuning). A separate set of 43 CT examinations from 42 patients (mean age, 10.1 years) was used as the test data. A commercial software program (MEDIP PRO v2.0.0.0, MEDICALIP Co. Ltd.) based on 2D U-NET was used to create liver segmentation masks with liver volume. The original 80 keV images were used as the ground truth. We used the paired t-test to compare the segmentation performance in the Dice similarity coefficient (DSC) and difference ratio of the liver volume relative to the ground truth volume before and after image standardization. The concordance correlation coefficient (CCC) was used to assess the agreement between the segmented liver volume and ground-truth volume. RESULTS: The original CT images showed variable and poor segmentation performances. The standardized images achieved significantly higher DSCs for liver segmentation than the original images (DSC [original, 5.40%-91.27%] vs. [standardized, 93.16%-96.74%], all P < 0.001). The difference ratio of liver volume also decreased significantly after image conversion (original, 9.84%-91.37% vs. standardized, 1.99%-4.41%). In all protocols, CCCs improved after image conversion (original, -0.006-0.964 vs. standardized, 0.990-0.998). CONCLUSION: Deep learning-based CT image standardization can improve the performance of automated hepatic segmentation using CT images reconstructed using various methods. Deep learning-based CT image conversion may have the potential to improve the generalizability of the segmentation network.


Assuntos
Aprendizado Profundo , Humanos , Criança , Fígado/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Abdome , Algoritmos , Processamento de Imagem Assistida por Computador/métodos
8.
Invest Radiol ; 57(5): 308-317, 2022 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-34839305

RESUMO

OBJECTIVES: This study aimed to evaluate the usefulness of deep learning-based image conversion to improve the reproducibility of computed tomography (CT) radiomics features. MATERIALS AND METHODS: This study was conducted using an abdominal phantom with liver nodules. We developed an image conversion algorithm using a residual feature aggregation network to reproduce radiomics features with CT images under various CT protocols and reconstruction kernels. External validation was performed using images from different scanners, consisting of 8 different protocols. To evaluate the variability of radiomics features, regions of interest (ROIs) were drawn by targeting the liver parenchyma, vessels, paraspinal area, and liver nodules. We extracted 18 first-order, 68 second-order, and 688 wavelet radiomics features. Measurement variability was assessed using the concordance correlation coefficient (CCC), compared with the ground-truth image. RESULTS: In the ROI-based analysis, there was an 83.3% improvement of CCC (80/96; 4 ROIs with 3 categories of radiomics features and 8 protocols) in synthetic images compared with the original images. Among them, the 56 CCC pairs showed a significant increase after image synthesis. In the radiomics feature-based analysis, 62.0% (3838 of 6192; 774 radiomics features with 8 protocols) features showed increased CCC after image synthesis, and a significant increase was noted in 26.9% (1663 of 6192) features. In particular, the first-order feature (79.9%, 115/144) showed better improvement in terms of the reproducibility of radiomics feature than the second-order (59.9%, 326/544) or wavelet feature (61.7%, 3397/5504). CONCLUSIONS: Our study demonstrated that a deep learning model for image conversion can improve the reproducibility of radiomics features across various CT protocols, reconstruction kernels, and CT scanners.


Assuntos
Aprendizado Profundo , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Tomógrafos Computadorizados , Tomografia Computadorizada por Raios X/métodos
9.
Yonsei Med J ; 62(3): 200-208, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33635009

RESUMO

PURPOSE: To compare image quality in selective intracoronary contrast-injected computed tomography angiography (Selective-CTA) with that in conventional intravenous contrast-injected CTA (IV-CTA). MATERIALS AND METHODS: Six pigs (35 to 40 kg) underwent both IV-CTA using an intravenous injection (60 mL) and Selective-CTA using an intracoronary injection (20 mL) through a guide-wire during/after percutaneous coronary intervention. Images of the common coronary artery were acquired. Scans were performed using a combined machine comprising an invasive coronary angiography suite and a 320-channel multi-slice CT scanner. Quantitative image quality parameters of CT attenuation, image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), mean lumen diameter (MLD), and mean lumen area (MLA) were measured and compared. Qualitative analysis was performed using intraclass correlation coefficient (ICC), which was calculated for analysis of interobserver agreement. RESULTS: Quantitative image quality, determined by assessing the uniformity of CT attenuation (399.06 vs. 330.21, p<0.001), image noise (24.93 vs. 18.43, p<0.001), SNR (16.43 vs. 18.52, p=0.005), and CNR (11.56 vs. 13.46, p=0.002), differed significantly between IV-CTA and Selective-CTA. MLD and MLA showed no significant difference overall (2.38 vs. 2.44, p=0.068, 4.72 vs. 4.95, p=0.078). The density of contrast agent was significantly lower for selective-CTA (13.13 mg/mL) than for IV-CTA (400 mg/mL). Agreement between observers was acceptable (ICC=0.79±0.08). CONCLUSION: Our feasibility study in swine showed that compared to IV-CTA, Selective-CTA provides better image quality and requires less iodine contrast medium.


Assuntos
Angiografia por Tomografia Computadorizada , Meios de Contraste/química , Angiografia Coronária , Aumento da Imagem , Animais , Vasos Coronários , Estudos de Viabilidade , Feminino , Processamento de Imagem Assistida por Computador , Doses de Radiação , Suínos
10.
Yonsei Med J ; 61(2): 137-144, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31997622

RESUMO

PURPOSE: To evaluate the diagnostic accuracy of a novel on-site virtual fractional flow reserve (vFFR) derived from coronary computed tomography angiography (CTA). MATERIALS AND METHODS: We analyzed 100 vessels from 57 patients who had undergone CTA followed by invasive FFR during coronary angiography. Coronary lumen segmentation and three-dimensional reconstruction were conducted using a completely automated algorithm, and parallel computing based vFFR prediction was performed. Lesion-specific ischemia based on FFR was defined as significant at ≤0.8, as well as ≤0.75, and obstructive CTA stenosis was defined that ≥50%. The diagnostic performance of vFFR was compared to invasive FFR at both ≤0.8 and ≤0.75. RESULTS: The average computation time was 12 minutes per patient. The correlation coefficient (r) between vFFR and invasive FFR was 0.75 [95% confidence interval (CI) 0.65 to 0.83], and Bland-Altman analysis showed a mean bias of 0.005 (95% CI -0.011 to 0.021) with 95% limits of agreement of -0.16 to 0.17 between vFFR and FFR. The accuracy, sensitivity, specificity, positive predictive value, and negative predictive value were 78.0%, 87.1%, 72.5%, 58.7%, and 92.6%, respectively, using the FFR cutoff of 0.80. They were 87.0%, 95.0%, 80.0%, 54.3%, and 98.5%, respectively, with the FFR cutoff of 0.75. The area under the receiver-operating characteristics curve of vFFR versus obstructive CTA stenosis was 0.88 versus 0.61 for the FFR cutoff of 0.80, respectively; it was 0.94 versus 0.62 for the FFR cutoff of 0.75. CONCLUSION: Our novel, fully automated, on-site vFFR technology showed excellent diagnostic performance for the detection of lesion-specific ischemia.


Assuntos
Simulação por Computador , Reserva Fracionada de Fluxo Miocárdico , Idoso , Algoritmos , Área Sob a Curva , Feminino , Humanos , Modelos Lineares , Masculino , Valor Preditivo dos Testes , Estudos Prospectivos , Curva ROC , Índice de Gravidade de Doença , Tomografia Computadorizada por Raios X
11.
Artigo em Inglês | MEDLINE | ID: mdl-31762536

RESUMO

BACKGROUND: Coronary computed tomography angiography (CTA) allows quantification of stenosis. However, such quantitative analysis is not part of clinical routine. We evaluated the feasibility of utilizing deep learning for quantifying coronary artery disease from CTA. METHODS: A total of 716 diseased segments in 156 patients (66 ± 10 years) who underwent CTA were analyzed. Minimal luminal area (MLA), percent diameter stenosis (DS), and percent contrast density difference (CDD) were measured using semi-automated software (Autoplaque) by an expert reader. Using the expert annotations, deep learning was performed with convolutional neural networks using 10-fold cross-validation to segment CTA lumen and calcified plaque. MLA, DS and CDD computed using deep-learning-based approach was compared to expert reader measurements. RESULTS: There was excellent correlation between the expert reader and deep learning for all quantitative measures (r=0.984 for MLA; r=0.957 for DS; and r=0.975 for CDD, p<0.001 for all). The expert reader and deep learning method was not significantly different for MLA (median 4.3 mm2 for both, p=0.68) and CDD (11.6 vs 11.1%, p=0.30), and was significantly different for DS (26.0 vs 26.6%, p<0.05); however, the ranges of all the quantitative measures were within inter-observer variability between 2 expert readers. CONCLUSIONS: Our deep learning-based method allows quantitative measurement of coronary artery disease segments accurately from CTA and may enhance clinical reporting.

12.
Eur Radiol ; 29(5): 2218-2225, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30421011

RESUMO

OBJECTIVE: This study aimed to evaluate the clinical feasibility of catheter-directed selective computed tomography angiography (S-CTA) in patients with coronary artery disease (CAD). METHODS: We prospectively enrolled 65 patients diagnosed with CAD who underwent conventional computed tomography angiography (C-CTA). C-CTA was performed with 60-90 mL of contrast medium (370 mg iodine/mL), whereas S-CTA was performed with 15 mL of contrast medium and 17.19 mg iodine/mL. Luminal enhancement range, homogeneity of luminal enhancement, image quality, plaque volume (PV), and percent aggregate plaque volume (%APV) were measured. Paired Student's t test, Wilcoxon rank-sum test, and Pearson's correlation coefficient were used to compare two methods. RESULTS: Luminal enhancement was significantly higher on S-CTA than on C-CTA (324.4 ± 8.0 Hounsfield unit (HU) vs. 312.0 ± 8.0 HU, p < 0.0001 in the per-vessel analysis). Transluminal attenuation gradient showed a significantly slower reduction pattern on S-CTA than on C-CTA (-0.65 HU/10 mm vs. -0.89 HU/10 mm, p < 0.0001 in the per-vessel analysis). Image noise was significantly lower on S-CTA than on C-CTA (39.6 ± 10.0 HU vs. 43.9 ± 9.4 HU, p < 0.0001). There was excellent correlation between S-CTA and C-CTA with respect to PV and %APV (r = 0.99, r = 0.98, respectively). CONCLUSIONS: S-CTA might be useful in facilitating atherosclerotic plaque analysis and providing guidance for complex lesions such as chronic total occlusion, particularly in cases in which on-site procedure planning is required. KEY POINTS: • Selective computed tomography angiography (S-CTA) can serve as an intraprocedural computed tomography angiography protocol. • S-CTA was performed with low dose of iodine compared with conventional computed tomography angiography. • S-CTA enables on-site atherosclerotic plaque analysis.


Assuntos
Cateterismo Cardíaco/métodos , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico , Iodo/administração & dosagem , Placa Aterosclerótica/diagnóstico , Meios de Contraste/administração & dosagem , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
13.
PLoS One ; 11(8): e0156837, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27536939

RESUMO

We propose a Bayesian tracking and segmentation method of coronary arteries on coronary computed tomographic angiography (CCTA). The geometry of coronary arteries including lumen boundary is estimated in Maximum A Posteriori (MAP) framework. Three consecutive sphere based filtering is combined with a stochastic process that is based on the similarity of the consecutive local neighborhood voxels and the geometric constraint of a vessel. It is also founded on the prior knowledge that an artery can be seen locally disconnected and consist of branches which may be seemingly disconnected due to plaque build up. For such problem, an active search method is proposed to find branches and seemingly disconnected but actually connected vessel segments. Several new measures have been developed for branch detection, disconnection check and planar vesselness measure. Using public domain Rotterdam CT dataset, the accuracy of extracted centerline is demonstrated and automatic reconstruction of coronary artery mesh is shown.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Vasos Coronários/diagnóstico por imagem , Teorema de Bayes , Vasos Coronários/anatomia & histologia , Humanos , Modelos Teóricos , Processos Estocásticos
14.
Comput Math Methods Med ; 2016: 4561979, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26904151

RESUMO

This paper presents a method for the automatic 3D segmentation of the ascending aorta from coronary computed tomography angiography (CCTA). The segmentation is performed in three steps. First, the initial seed points are selected by minimizing a newly proposed energy function across the Hough circles. Second, the ascending aorta is segmented by geodesic distance transformation. Third, the seed points are effectively transferred through the next axial slice by a novel transfer function. Experiments are performed using a database composed of 10 patients' CCTA images. For the experiment, the ground truths are annotated manually on the axial image slices by a medical expert. A comparative evaluation with state-of-the-art commercial aorta segmentation algorithms shows that our approach is computationally more efficient and accurate under the DSC (Dice Similarity Coefficient) measurements.


Assuntos
Aorta/diagnóstico por imagem , Angiografia por Tomografia Computadorizada , Imageamento Tridimensional , Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia Computadorizada por Raios X , Algoritmos , Aorta/patologia , Artefatos , Bases de Dados Factuais , Reações Falso-Positivas , Humanos , Processamento de Imagem Assistida por Computador , Modelos Estatísticos , Reconhecimento Automatizado de Padrão , Reprodutibilidade dos Testes , Fatores de Risco
15.
J Cardiovasc Comput Tomogr ; 9(4): 321-328, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26088379

RESUMO

BACKGROUND: Given the lack of promptness and inevitable use of additional contrast agents, the myocardial viability imaging procedures have not been used widely for determining the need to performing revascularization. OBJECTIVE: This study is aimed to evaluate the feasibility of myocardial viability assessment, consecutively with diagnostic invasive coronary angiography (ICA) without use of additional contrast agent, using a novel hybrid system comprising ICA and multislice CT (MSCT). METHODS: In all, 14 Yucatan miniature swine models (female; age, 3 months; weight, 28-30 kg) were subjected to ICA followed by balloon occlusion (90 minutes) and reperfusion of the left anterior descending coronary artery. Two weeks after induction of myocardial infarction, delayed hyperenhancement (DHE) images were obtained, using a novel combined machine comprising ICA and 320-channel MSCT scanner (Aquilion ONE, Toshiba), after 2, 5, 7, 10, 15, and 20 minutes after conventional ICA. The heart was sliced in 10-mm consecutive sections in the short-axis plane and was embedded in a solution of 1% triphenyltetrazolium chloride (TTC). Infarct size was determined as TTC-negative areas as a percentage of total left ventricular area. On MSCT images, infarct size per slice was calculated by dividing the DHE area by the total slice area (%) and compared with histochemical analyses. RESULTS: Serial MSCT scans revealed a peak CT attenuation of the infarct area (222.5 ± 36.5 Hounsfield units) with a maximum mean difference in CT attenuation between the infarct areas and normal myocardium of at 2 minutes after contrast injection (106.4; P for difference = 0.002). Furthermore, the percentage difference of infarct size by MSCT vs histopathologic specimen was significantly lower at 2 (8.5% ± 1.8%) and 5 minutes (9.5% ± 1.9%) than those after 7 minutes. Direct comparisons of slice-matched DHE area by MSCT demonstrated excellent correlation with TTC-derived infarct size (r = 0.952; P < .001). Bland-Altman plots of the differences between DHE by MSCT and TTC-derived infarct measurements plotted against their means showed good agreement between the 2 methods. CONCLUSION: The feasibility of myocardial viability assessment by DHE using MSCT after conventional ICA was proven in experimental models, and the optimal viability images were obtained after 2 to 5 minutes after the final intracoronary injection of contrast agent for conventional ICA.


Assuntos
Angiografia Coronária/métodos , Tomografia Computadorizada Multidetectores/métodos , Imagem Multimodal/métodos , Infarto do Miocárdio/diagnóstico por imagem , Miocárdio Atordoado/diagnóstico por imagem , Radiografia Intervencionista/métodos , Animais , Meios de Contraste/administração & dosagem , Feminino , Infarto do Miocárdio/complicações , Infarto do Miocárdio/patologia , Miocárdio Atordoado/etiologia , Miocárdio Atordoado/patologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Suínos , Sobrevivência de Tecidos
16.
Invest Radiol ; 50(7): 449-55, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25816215

RESUMO

OBJECTIVE: Selective catheter-directed intracoronary contrast injected coronary computed tomography angiography (selective CCTA) has recently been introduced for on-site evaluation of coronary artery disease during coronary artery catheterization. In this study, we aimed to develop a feasible protocol for selective CCTA using ultralow-dose contrast medium as compared with conventional intravenous CCTA (IV CCTA). MATERIALS AND METHODS: A novel combined system incorporating coronary angiography and a 320-detector row computed tomographic scanner was used to study 4 swine (35-40 kg) under animal institutional review board approval. A selective CCTA scan was simultaneously performed with an injection of 13.13 mgI/mL of modulated contrast medium at multiple different injection rates including 2, 3, and 4 mL/s and different total injection volumes of either 20 or 30 mL. Intravenous CCTA was performed with 60 mL of contrast medium, followed by 30 mL of saline chaser at 5 mL/s. Coronary mean and peak intensity, transluminal attenuation gradient, as well as 3-dimensional maximum intensity projections were obtained. RESULTS: Attenuation values (mean ± standard error, in Hounsfield units [HUs]) of selective CCTA for the left anterior descending (LAD) and right coronary artery (RCA) using the various combinations of injection rates and total injection volumes were as follows: 20 mL at 2 mL/s (LAD, 270.3 ± 20.4 HU; RCA, 322.6 ± 7.4 HU), 20 mL at 3 mL/s (LAD, 262.9 ± 20.4 HU; RCA, 264.7 ± 7.4 HU), 30 mL at 3 mL/s (LAD, 276.8 ± 20.4 HU; RCA, 274.0 ± 7.4 HU), 20 mL at 4 mL/s (LAD, 268.0 ± 20.4 HU; RCA, 277.7 ± 7.4 HU), and 30 mL at 4 mL/s (LAD, 251.3 ± 20.4 HU; RCA, 334.7 ± 7.4 HU). The representative protocol of the selective CCTA studies produced results within the optimal enhancement range (approximately 250-350 HU) for all segments, and comparison of transluminal attenuation gradient data with selective CCTA and IV CCTA studies demonstrated that the former method was more homogenous (-1.5245 and -1.7558 for LAD as well as 0.0459 and 0.0799 for RCA, respectively). Notably, the volume of iodine contrast medium used for selective CCTA was reported to be 1.09% (0.2 g) of IV CCTA (24 g). CONCLUSIONS: The current findings demonstrate the feasibility of selective CCTA using ultralow-dose intracoronary contrast injection. This technique may provide additional means of coronary evaluation in patients who may require strategic planning before a procedure using a combined modality system.


Assuntos
Cateterismo Cardíaco/métodos , Angiografia Coronária/métodos , Aumento da Imagem/métodos , Iopamidol/análogos & derivados , Proteção Radiológica/métodos , Tomografia Computadorizada por Raios X/métodos , Animais , Meios de Contraste/administração & dosagem , Relação Dose-Resposta a Droga , Estudos de Viabilidade , Feminino , Interpretação de Imagem Assistida por Computador/métodos , Iopamidol/administração & dosagem , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Vinho
17.
Comput Methods Programs Biomed ; 117(2): 179-88, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25106730

RESUMO

We propose a fast seed detection for automatic tracking of coronary arteries in coronary computed tomographic angiography (CCTA). To detect vessel regions, Hessian-based filtering is combined with a new local geometric feature that is based on the similarity of the consecutive cross-sections perpendicular to the vessel direction. It is in turn founded on the prior knowledge that a vessel segment is shaped like a cylinder in axial slices. To improve computational efficiency, an axial slice, which contains part of three main coronary arteries, is selected and regions of interest (ROIs) are extracted in the slice. Only for the voxels belonging to the ROIs, the proposed geometric feature is calculated. With the seed points, which are the centroids of the detected vessel regions, and their vessel directions, vessel tracking method can be used for artery extraction. Here a particle filtering-based tracking algorithm is tested. Using 19 clinical CCTA datasets, it is demonstrated that the proposed method detects seed points and can be used for full automatic coronary artery extraction. ROC (receiver operating characteristic) curve analysis shows the advantages of the proposed method.


Assuntos
Inteligência Artificial , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Reconhecimento Automatizado de Padrão/métodos , Intensificação de Imagem Radiográfica/métodos , Tomografia Computadorizada por Raios X/métodos , Sistemas Computacionais , Humanos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
18.
J Am Coll Cardiol ; 60(21): 2205-15, 2012 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-23103039

RESUMO

OBJECTIVES: This study was designed to determine the prognostic value of multidetector coronary computed tomography angiography (CTA) in relation to exercise electrocardiography (XECG) findings. BACKGROUND: The prognostic usefulness of coronary CTA findings of coronary artery disease in relation to XECG findings has not been explored systematically. METHODS: Patients with suspected coronary artery disease who had undergone both coronary CTA and XECG (<90 days between tests) from 2003 through 2009 were enrolled retrospectively. Coronary CTA results were classified according to the severity of maximal stenosis (normal, mild: <40% of luminal stenosis, moderate: 40% to 69%, severe: ≥70%), XECG results were categorized as positive and negative, and Duke XECG score was calculated. Clinical follow-up data were collected for major adverse cardiac events (MACE): cardiac death, nonfatal myocardial infarction, unstable angina requiring hospitalization, and revascularization after 90 days from index coronary CTA. C-statistics were calculated to compare discriminatory values of each test. RESULTS: Among the 2,977 (58 ± 10 years) study patients, 12% demonstrated positive XECG results. By coronary CTA, patients were categorized as normal (56%) or having mild (26%), moderate (13%), or severe (5%) disease. During a median follow-up of 3.3 years (interquartile range: 2.3 to 4.6), 97 MACE were observed and the 5-year cumulative event rate was 3.6% (95% confidence interval: 3.0 to 4.3). Although both XECG (C-statistic: 0.790) and coronary CTA (C-statistic: 0.908) improved risk stratification beyond clinical risk factors (C-statistic: 0.746, p < 0.05 for all), XECG in addition to coronary CTA (C-statistic: 0.907) did not provide better discrimination than coronary CTA alone (p = 0.389). In subgroup analyses, coronary CTA stratified risk of MACE in groups with both positive and negative XECG results (all p < 0.001 for trend). However, positive XECG results predicted risk of MACE on coronary CTA only in the moderate stenosis group (hazard ratio: 2.58, 95% confidence interval: 1.29 to 5.19, p = 0.008) and severe stenosis group (hazard ratio: 2.28, 95% confidence interval: 1.19 to 4.38, p = 0.013). CONCLUSIONS: In patients with suspected coronary artery disease, coronary CTA discriminates future risk of MACE in patients independent of XECG results. Compared with coronary CTA, XECG has an additive prognostic value only in patients with moderate to severe stenosis on coronary CTA.


Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico , Eletrocardiografia , Teste de Esforço/métodos , Exercício Físico/fisiologia , Tomografia Computadorizada Multidetectores/métodos , Adulto , Doença da Artéria Coronariana/fisiopatologia , Diagnóstico Diferencial , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos , Índice de Gravidade de Doença , Fatores de Tempo
19.
Org Lett ; 9(19): 3745-8, 2007 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-17705502

RESUMO

Catalytic hydrogenation of 1,3-enynes 1a-8a in the presence of ethyl glyoxalate at ambient pressure and temperature using a rhodium catalyst modified by (R)-(3,5-tBu-4-MeOPh)-MeO-BIPHEP results in highly regio- and enantioselective reductive coupling to furnish the corresponding alpha-hydroxy esters 1b-8b. As demonstrated by the elaboration of alpha-hydroxy ester 1b, the terminal and internal olefin moieties embodied by the diene side chain are subject to selective manipulation, one over the other.


Assuntos
Ésteres/síntese química , Hidrogênio/química , Oxalatos/química , Catálise , Ésteres/química , Etilenos/química , Estrutura Molecular , Estereoisomerismo
20.
Org Lett ; 9(12): 2281-4, 2007 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-17497795

RESUMO

The C2-symmetric bis(oxazoline) copper(II) complex proves to be an excellent catalyst in the Friedel-Crafts alkylation of indoles with alpha'-phosphoric enones. The enantioselectivities of this reaction are obtained in up to 98% ee.


Assuntos
Cobre/química , Indóis/química , Indóis/síntese química , Cetonas/química , Compostos Organometálicos/química , Alquilação , Catálise , Estrutura Molecular , Organofosfonatos/química , Estereoisomerismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...