RESUMO

Previous research has shown that Escherichia coli infection rates peak in the summer; however, to date there has been no investigation as to whether this is seen in both hospital and community-onset cases, and how this differs across regions. We investigated and quantified E. coli bloodstream infection (BSI) seasonality. A generalized additive Poisson model was fitted to mandatory E. coli BSI surveillance data reported in England. There was no impact of seasonality in hospital-onset cases; however, for the community-onset cases, there was statistically significant seasonal variation over time nationally. When examined regionally, seasonality was significant in the North of England only. This variation resulted in an absolute increase of 0.06 (95% CI 0.02-0.1) cases above the mean (3.25) in each hospital trust for each week of the peak summer season, and a decrease of (-) 0.07 (95% CI -0.1 to -0.03) in the autumn. We estimate that fewer than one hospital bed-day per week per hospital is lost because of seasonal increases during the summer. Our findings highlight the need to understand the distinct community and hospital dynamics of E. coli BSI, and to explore the regional differences driving the variation in incidence, in order to design and implement effective control measures.


Assuntos
Bacteriemia/epidemiologia , Infecções por Escherichia coli/epidemiologia , Infecções Comunitárias Adquiridas/epidemiologia , Infecção Hospitalar/epidemiologia , Inglaterra/epidemiologia , Monitoramento Epidemiológico , Geografia , Humanos , Incidência , Estações do Ano
2.
Clin Microbiol Infect ; 21(9): 850.e1-4, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25964154

RESUMO

In October 2007, a governmental 3-year target to reduce Clostridium difficile infection (CDI) by 30%, with financial penalties levied for failure, was introduced in England. This target was met within just 1 year, leading to speculation of 'gaming', with hospitals empirically treating possible CDI in the absence of a microbiological diagnosis, to avoid having to report confirmed cases. An analysis of aggregate mandatory data on levels of testing for C. difficile toxin showed little evidence of a fall in testing during the steepest infection rate reductions, suggesting that this was not a major factor in the decline in CDI.


Assuntos
Toxinas Bacterianas/análise , Clostridioides difficile/isolamento & purificação , Infecções por Clostridium/diagnóstico , Infecções por Clostridium/microbiologia , Enterocolite/diagnóstico , Enterocolite/microbiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Infecções por Clostridium/epidemiologia , Inglaterra/epidemiologia , Enterocolite/epidemiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Programas Nacionais de Saúde , Prevalência , Adulto Jovem
3.
Clin Microbiol Infect ; 21(3): 251.e1-8, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25698659

RESUMO

Escherichia coli is the commonest cause of bacteraemia in England, with an incidence of 50.7 cases per 100 000 population in 2011. We undertook a large national study to estimate and identify risk factors for 30-day all-cause mortality in E. coli bacteraemia patients. Records for patients with E. coli bacteraemia reported to the English national mandatory surveillance system between 1 July 2011 and 30 June 2012 were linked to death registrations to determine 30-day all-cause mortality. A multivariable regression model was used to identify factors associated with 30-day all-cause mortality. There were 5220 deaths in 28 616 E. coli bacteraemia patients, a mortality rate of 18.2% (95% CI 17.8-18.7%). Three-quarters of deaths occurred within 14 days of specimen collection. Factors independently associated with increased mortality were: age < 1 year or > 44 years; an underlying respiratory or unknown infection focus; ciprofloxacin non-susceptibility; hospital-onset infection or not being admitted; and bacteraemia occurring in the winter. Female gender and a urogenital focus were associated with a reduction in mortality. This is the first national study of mortality among E. coli bacteraemia patients in England. Interventions to reduce mortality need to be multifaceted and include both primary and secondary healthcare providers. Greater awareness of the risk factors for and symptoms of E. coli bacteraemia may prompt earlier diagnosis and treatment. Changes in antimicrobial resistance patterns need to be monitored for their potential impact on infection and mortality.


Assuntos
Bacteriemia , Infecções por Escherichia coli/epidemiologia , Escherichia coli , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Antibacterianos/farmacologia , Causas de Morte , Criança , Pré-Escolar , Infecção Hospitalar , Inglaterra/epidemiologia , Escherichia coli/efeitos dos fármacos , Escherichia coli/isolamento & purificação , Infecções por Escherichia coli/microbiologia , Infecções por Escherichia coli/mortalidade , Feminino , Seguimentos , Humanos , Incidência , Lactente , Recém-Nascido , Tempo de Internação , Masculino , Testes de Sensibilidade Microbiana , Pessoa de Meia-Idade , Mortalidade , Razão de Chances , Vigilância da População , Fatores de Risco , Adulto Jovem
4.
Lasers Surg Med ; 40(4): 243-6, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18412228

RESUMO

PURPOSE: To evaluate the potential occupational health hazards associated with scattered ultraviolet (UV) radiation during photorefractive keratectomy (PRK) using the VISX Star S3 excimer laser. SETTING: The Laser Vision Center, National Naval Medical Center, Bethesda, Maryland, USA. METHODS: Intraoperative radiometric measurements were made with the Ophir Power/Energy Meter (LaserStar Model PD-10 with silicon detector) during PRK treatments as well as during required calibration procedures at a distance of 20.3 cm from the left cornea. These measurements were evaluated using a worst-case scenario for exposure, and then compared with the American Conference of Governmental Industrial Hygeinists (ACGIH) Threshold Value Limits (TVL) to perform a risk/hazard analysis. RESULTS: During the PRK procedures, the highest measured value was 248.4 nJ/pulse. During the calibration procedures, the highest measured UV scattered radiation level was 149.6 nJ/pulse. The maximum treatment time was 52 seconds. Using a worst-case scenario in which all treatments used the maximum power and time, the total energy per eye treated was 0.132 mJ/cm2 and the total UV radiation at close range (80 cm from the treated eye) was 0.0085 mJ/cm2. With a workload of 20 patients, the total occupational exposure at 80 cm to actinic UV radiation in an 8-hour period would be 0.425 mJ/cm2. CONCLUSIONS: The scattered actinic UV laser radiation from the VISX Star S3 excimer laser did not exceed occupational exposure limits during a busy 8-hour workday, provided that operating room personnel were at least 80 cm from the treated eye. While the use of protective eyewear is always prudent, this study demonstrates that the trace amounts of scattered laser emissions produced by this laser do not pose a serious health risk even without the use of protective eyewear.


Assuntos
Exposição Ocupacional , Ceratectomia Fotorrefrativa , Raios Ultravioleta , Calibragem , Dispositivos de Proteção dos Olhos , Humanos , Lasers de Excimer , Lesões por Radiação/prevenção & controle , Medição de Risco , Espalhamento de Radiação