Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
Magn Reson Imaging ; 110: 43-50, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38604346

RESUMO

PURPOSE: Lower extremity magnetic resonance angiography (MRA) without electrocardiography (ECG) or peripheral pulse unit (PPU) triggering and contrast enhancement is beneficial for diagnosing peripheral arterial disease (PAD) while avoiding synchronization failure and nephrogenic systemic fibrosis. This study aimed to compare the diagnostic performance of turbo spin-echo-based enhanced acceleration-selective arterial spin labeling (eAccASL) (TSE-Acc) of the lower extremities with that of turbo field-echo-based eAccASL (TFE-Acc) and triggered angiography non-contrast enhanced (TRANCE). METHODS: Nine healthy volunteers and a patient with PAD were examined on a 3.0 Tesla magnetic resonance imaging (MRI) system. The artery-to-muscle signal intensity ratio (SIR) and contrast-to-noise ratio (CNR) were calculated. The arterial visibility (1: poor, 4: excellent) and artifact contamination (1: severe, 4: no) were independently assessed by two radiologists. Phase-contrast MRI and digital subtraction angiography were referenced in a patient with PAD. Friedman's test and a post-hoc test according to the Bonferroni-adjusted Wilcoxon signed-rank test were used for the SIR, CNR, and visual assessment. p < 0.05 was considered statistically significant. RESULTS: No significant differences in nearly all the SIRs were observed among the three MRA methods. Higher CNRs were observed with TSE-Acc than those with TFE-Acc (anterior tibial artery, p = 0.014; peroneal artery, p = 0.029; and posterior tibial artery, p = 0.014) in distal arterial segments; however, no significant differences were observed upon comparison with TRANCE (all p > 0.05). The arterial visibility scores exhibited similar trends as the CNRs. The artifact contamination scores with TSE-Acc were significantly lower (but within an acceptable level) compared to those with TFE-Acc. In the patient with PAD, the sluggish peripheral arteries were better visualized using TSE-Acc than those using TFE-Acc, and the collateral and stenosis arteries were better visualized using TSE-Acc than those using TRANCE. CONCLUSION: Peripheral arterial visualization was better with TSE-Acc than that with TFE-Acc in lower extremity MRA without ECG or PPU triggering and contrast enhancement, which was comparable with TRANCE as the reference standard. Furthermore, TSE-Acc may propose satisfactory diagnostic performance for diagnosing PAD in patients with arrhythmia and chronic kidney disease.


Assuntos
Meios de Contraste , Extremidade Inferior , Angiografia por Ressonância Magnética , Doença Arterial Periférica , Marcadores de Spin , Humanos , Angiografia por Ressonância Magnética/métodos , Doença Arterial Periférica/diagnóstico por imagem , Masculino , Feminino , Extremidade Inferior/diagnóstico por imagem , Extremidade Inferior/irrigação sanguínea , Adulto , Pessoa de Meia-Idade , Eletrocardiografia , Idoso , Artefatos , Aumento da Imagem/métodos , Reprodutibilidade dos Testes
2.
Sci Rep ; 13(1): 4426, 2023 03 17.
Artigo em Inglês | MEDLINE | ID: mdl-36932141

RESUMO

Punctate white matter lesions (PWMLs) in infants may be related to neurodevelopmental outcomes based on the location or number of lesions. This study aimed to assess the automatic detectability of PWMLs in infants on deep learning using composite images created from several cases. To create the initial composite images, magnetic resonance (MR) images of two infants with the most PWMLs were used; their PWMLs were extracted and pasted onto MR images of infants without abnormality, creating many composite PWML images. Deep learning models based on a convolutional neural network, You Only Look Once v3 (YOLOv3), were constructed using the training set of 600, 1200, 2400, and 3600 composite images. As a result, a threshold of detection probability of 20% and 30% for all deep learning model sets yielded a relatively high sensitivity for automatic PWML detection (0.908-0.957). Although relatively high false-positive detections occurred with the lower threshold of detection probability, primarily, in the partial volume of the cerebral cortex (≥ 85.8%), those can be easily distinguished from the white matter lesions. Relatively highly sensitive automatic detection of PWMLs was achieved by creating composite images from two cases using deep learning.


Assuntos
Aprendizado Profundo , Substância Branca , Humanos , Lactente , Córtex Cerebral/patologia , Imageamento por Ressonância Magnética/métodos , Probabilidade , Substância Branca/diagnóstico por imagem , Substância Branca/patologia
3.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 79(4): 331-341, 2023 Apr 20.
Artigo em Japonês | MEDLINE | ID: mdl-36792206

RESUMO

PURPOSE: The purpose of this study was to investigate the optimal spatial resolution and temporal resolution of dynamic improved motion-sensitized driven-equilibrium steady-state free precession for visualization of respiratory-driven cerebrospinal fluid (CSF) dynamics. METHODS: We investigated the differences in the visualization using the midsagittal cross-sections of nine healthy volunteers by three imaging conditions. (A: spatial resolution 0.49×0.49×5 mm, temporal resolution 1000 ms; B: 0.49×0.49×5 mm, 430 ms; and C: 0.78×0.78×5 mm, 200 ms). First, we calculated the CSF of the third and fourth ventricles and the signal-to-noise ratio (SNR) of the pons. Next, we calculated the signal intensity ratio (SIR) of the CSF flowing at 10 cm/s or more and the CSF flowing at 10 cm/s or less due to respiration. We also calculated the difference between the inspiration and expiration SIR. Furthermore, 1) the presence of flow in the third and fourth ventricles centered on the cerebral aqueduct and 2) the change in flow due to respiration was investigated by a three-point scale visual assessment by seven radiological technologists. RESULTS: The SNR was the highest in A, the next highest in B, and the lowest in C in all cases. There were significant differences between A and B, and A and C in CSF of the third and fourth ventricles. However, there was no significant difference between B and C. The CSF signal intensity changed with respiration. The SIR of the third ventricle was higher on inspiration and lower on expiration. Conversely, the SIR of the fourth ventricle was lower on inspiration and higher on expiration. There was a significant difference between A and C and B and C in each SIR (p<0.05). The difference between inspiration and expiration SIR was the highest in B, the next highest in A, and the lowest in C in both the third and fourth ventricles. Significant differences were found between A and C, and between B and C (p<0.05). There was no significant difference in the presence of flow in the third and fourth ventricles centered on the cerebral aqueduct (p=0.264). On the other hand, there was a significant difference between the imaging conditions in the change in flow due to respiration, with B having a higher value than the others (p<0.001). CONCLUSION: The optimal spatial and temporal resolutions were 0.49×0.49×5 mm and 430 ms, respectively. The results also suggest that it is important to carefully set the imaging conditions for the spatial and temporal resolutions because of the use of phase dispersion in this method.


Assuntos
Imageamento por Ressonância Magnética , Respiração , Humanos , Imageamento por Ressonância Magnética/métodos , Movimento (Física) , Razão Sinal-Ruído , Voluntários Saudáveis , Líquido Cefalorraquidiano/diagnóstico por imagem
4.
Magn Reson Imaging ; 99: 1-6, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36608908

RESUMO

OBJECTIVE: Brain temperature monitoring using a catheter thermometer has been reported to be a useful technique to predict prognosis in neurosurgery. To investigate the possibility of measuring intracranial cerebrospinal fluid temperature for postoperative monitoring in patients with Moyamoya disease (MMD) after bypass surgery. MATERIALS AND METHODS: This study evaluated fifteen patients with MMD who were indicated for bypass surgery. Diffusion tensor imaging for brain thermometry were performed on a 1.5-T MR scanner. Intracranial cerebrospinal fluid temperature with/without considering the fractional anisotropy component, body temperature, C-reactive protein levels, white blood cell count, and cerebral blood flow measured by 123I-IMP single-photon emission computed tomography were obtained before surgery and 1-3 days after surgery. Pixel values considered to be signal outliers in fractional anisotropy processing were defined as cerebrospinal fluid noise index and calculated. Wilcoxon signed-rank test and effect size were performed to compare the changes before and after revascularization. Spearman's rho correlation coefficient was used to analyze the correlations between each parameter. Statistical significance was defined as p < 0.05. RESULTS: All parameter values became significantly higher compared to those measured before revascularization (p < 0.01 in all cases). The effect sizes were largest for the cerebrospinal fluid temperature with fractional anisotropy processing and for C-reactive protein levels (Rank-biserial correlation = 1.0). The cerebrospinal fluid noise index and cerebrospinal fluid temperatures with fractional anisotropy processing (r = 0.84, p < 0.0001) or without fractional anisotropy processing (r = 0.95, p < 0.0001) showed highly significant positive correlations. Although no significant correlation was observed, cerebrospinal fluid temperatures with fractional anisotropy had small or moderately positive correlations with cerebral blood flow, body temperature, C-reactive protein levels, and white blood cell count (r = 0.37, 0.42, 0.41, and 0.44, respectively; p > 0.05). CONCLUSION: Our findings suggest the possibility of postoperative monitoring for MMD patients by measuring intracranial cerebrospinal fluid temperature with fractional anisotropy processing. Intracranial cerebrospinal fluid temperature might be considered as combined response since cerebrospinal fluid, body temperature, and inflammation are equally correlated.


Assuntos
Imagem de Tensor de Difusão , Doença de Moyamoya , Humanos , Imagem de Tensor de Difusão/métodos , Temperatura , Temperatura Corporal , Proteína C-Reativa , Anisotropia
5.
Magn Reson Med Sci ; 21(2): 372-379, 2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-35173115

RESUMO

PURPOSE: To extract the status of hydrocephalus and other cerebrospinal fluid (CSF)-related diseases, a technique to characterize the cardiac- and respiratory-driven CSF motions separately under free breathing was developed. This technique is based on steady-state free precession phase contrast (SSFP-PC) imaging in combination with a Stockwell transform (S-transform). METHODS: 2D SSFP-PC at 3 T was applied to measure the CSF velocity in the caudal-cranial direction within a sagittal slice at the midline (N = 3) under 6-, 10-, and 16-s respiratory cycles and free breathing. The frequency-dependent window width of the S-transform was controlled by a particular scaling factor, which then converted the CSF velocity waveform into a spectrogram. Based on the frequency bands of the cardiac pulsation and respiration, as determined by the electrocardiogram (ECG) and respirator pressure sensors, Gaussian bandpass filters were applied to the CSF spectrogram to extract the time-domain cardiac- and respiratory-driven waveforms. RESULTS: The cardiac-driven CSF velocity component appeared in the spectrogram clearly under all respiratory conditions. The respiratory-driven velocity under the controlled respiratory cycles was observed as constant frequency signals, compared to a time-varying frequency signal under free breathing. When the widow width was optimized using the scale factor, the temporal change in the respiratory-driven CSF component was even more apparent under free breathing. CONCLUSION: Velocity amplitude variations and transient frequency changes of both cardiac- and respiratory-driven components were successfully characterized. These findings indicated that the proposed technique is useful for evaluating CSF motions driven by different cyclic forces.


Assuntos
Coração , Imageamento por Ressonância Magnética , Líquido Cefalorraquidiano , Imageamento por Ressonância Magnética/métodos , Microscopia de Contraste de Fase , Movimento (Física) , Respiração
6.
Neurosci Lett ; 765: 136281, 2021 11 20.
Artigo em Inglês | MEDLINE | ID: mdl-34601040

RESUMO

To develop a suitable automobile design as per each driver's characteristics and state, it is important to understand the brain function in acquiring driving skills. Reportedly, the brain structures of professionals, such as athletes and musicians, and those who have received training in special skills, undergo changes with training. However, the development process of the brain in terms of acquiring driving skills has not yet been clarified. In this study, we evaluated the effects of driving training on the brain and observed an increase in the volume of the right cerebellum after short-term training (3 days). The right cerebellum is responsible for controlling the right hand and right foot, which are important for driving. Drivers train to control a vehicle smoothly at high speeds at gymkhana and pylon slalom courses, which are often used in motor sports. The brain structure was analyzed before and after training using magnetic resonance imaging. Voxel-based morphometry was used to assess possible structural changes. First, the lap times after training were clearly shortened and vehicle dynamics were more stable, indicating that the drivers' skill level clearly improved. Second, brain structural analysis revealed a volumetric increase in the right cerebellum. The cerebellum is involved in the process of learning sensory motor skills, such as smooth steering and pedal operations, driving course shape, and vehicle size perception. These results suggest a new inner model for driving operation and support the hypothesis that motor learning affects the cerebellum during vehicle driving training.


Assuntos
Condução de Veículo/educação , Cerebelo/anatomia & histologia , Cerebelo/fisiologia , Aprendizagem/fisiologia , Destreza Motora/fisiologia , Adulto , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Ensino
7.
Neurol Med Chir (Tokyo) ; 61(12): 711-720, 2021 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-34526448

RESUMO

Neurofluids, a recently developed term that refers to interstitial fluids in the parenchyma and cerebrospinal fluid (CSF) in the ventricle and subarachnoid space, play a role in draining waste products from the brain. Neurofluids have been implicated in pathological conditions such as Alzheimer's disease and normal pressure hydrocephalus. Given that CSF moves faster in the CSF cavity than in the brain parenchyma, CSF motion can be detected by magnetic resonance imaging. CSF motion is synchronized to the heartbeat and respiratory cycle, but respiratory cycle-induced CSF motion has yet to be investigated in detail. Therefore, we analyzed CSF motion using dynamic improved motion-sensitized driven-equilibrium steady-state free precession-based analysis. We analyzed CSF motion linked to the respiratory cycle in four women and six men volunteers aged 23 to 38 years. We identified differences between free respiration and tasked respiratory cycle-associated CSF motion in the ventricles and subarachnoid space. Our results indicate that semi-quantitative analysis can be performed using the cranial site at which CSF motion is most prominent as a standard. Our findings may serve as a reference for elucidating the pathophysiology of diseases caused by abnormalities in neurofluids.


Assuntos
Ventrículos Cerebrais , Imageamento por Ressonância Magnética , Ventrículos Cerebrais/diagnóstico por imagem , Líquido Cefalorraquidiano/diagnóstico por imagem , Feminino , Humanos , Espectroscopia de Ressonância Magnética , Masculino , Movimento (Física) , Espaço Subaracnóideo/diagnóstico por imagem
8.
Magn Reson Med Sci ; 20(4): 385-395, 2021 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-33551384

RESUMO

PURPOSE: The cardiac- and respiratory-driven components of cerebrospinal fluid (CSF) motion characteristics and bulk flow are not yet completely understood. Therefore, the present study aimed to characterize cardiac- and respiratory-driven CSF motions in the intracranial space using delay time, CSF velocity waveform correlation, and displacement. METHODS: Asynchronous two-dimensional phase-contrast at 3T was applied to measure the CSF velocity in the inferior-superior direction in a sagittal slice at the midline (N = 12) and an axial slice at the foramen magnum (N = 8). Volunteers were instructed to engage in six-second respiratory cycles. The calculated delay time and correlation coefficients of the cardiac- and respiratory-driven velocity waveforms, separated in the frequency domain, were applied to evaluate the propagation of the CSF motion. The cardiac- and respiratory-driven components of the CSF displacement and motion volume were calculated during diastole and systole, and during inhalation and exhalation, respectively. The cardiac- and respiratory-driven components of the velocity, correlation, displacement, and motion volume were compared using an independent two-sample t-test. RESULTS: The ratio of the cardiac-driven CSF velocity to the sum of the cardiac- and respiratory-driven CSF velocities was higher than the equivalent respiratory-driven ratio for all cases (P < 0.01). Delay time and correlation maps demonstrated that the cardiac-driven CSF motion propagated more extensively than the respiratory-driven CSF motion. The correlation coefficient of the cardiac-driven motion was significantly higher in the prepontine (P < 0.01), the aqueduct, and the fourth ventricle (P < 0.05). The respiratory-driven displacement and motion volume were significantly greater than the cardiac-driven equivalents for all observations (P < 0.01). CONCLUSION: The correlation mapping technique characterized the cardiac- and respiratory-driven CSF velocities and their propagation properties in the intracranial space. Based on these findings, cardiac-driven CSF velocity is greater than respiratory-induced velocity, but the respiratory-driven velocity might displace farther.


Assuntos
Coração , Imageamento por Ressonância Magnética , Ventrículos Cerebrais , Líquido Cefalorraquidiano/diagnóstico por imagem , Coração/diagnóstico por imagem , Humanos , Microscopia de Contraste de Fase , Movimento (Física)
9.
Magn Reson Med Sci ; 20(1): 112-118, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-32188834

RESUMO

The feasibility of the 3D dynamic improved motion-sensitized driven-equilibrium steady-state free precession (3D dynamic iMSDE SSFP) was evaluated for visualizing CSF motion and the appropriate parameters were determined. Both flow phantom and volunteer studies revealed that linear ordering and the shortest acquisition duration time were optimal. 3D dynamic iMSDE SSFP provides good quality imaging of CSF motion in the whole brain and enables visualization of flow in arbitrary planes from a single 3D volume scan.


Assuntos
Encéfalo/diagnóstico por imagem , Líquido Cefalorraquidiano/diagnóstico por imagem , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Humanos , Movimento/fisiologia , Imagens de Fantasmas
10.
Medicines (Basel) ; 7(6)2020 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-32630364

RESUMO

Background: Superficial siderosis is a progressively disabling disease caused by recurrent subarachnoid hemorrhage with accumulation of hemosiderin in the surface of the central nervous system. Although a wide variety of conditions may cause superficial siderosis, approximately half of the cases are reported to be associated with a defect in the ventral spinal dura mater, in which case treatment entails surgical repair of the defect. Here, we report a case of superficial siderosis and report on our method to pinpoint the dural defect using a combination of magnetic resonance imaging (MRI) techniques. Methods and Results: A 74-year-old female presented suffering from hearing loss and progressive ataxia over a duration of seven years. A T2-weighted MRI study revealed hypointensity in the superficial areas of the central nervous system, leading to the diagnosis of superficial siderosis, and the presence of a fluid-filled collection in the anterior spinal canal of C7 to T10 suggested that a dural defect was the cause of the repeated hemorrhage. A balanced turbo field echo (BTFE) MRI sequence revealed possible dural defects at T1-T2 and T5-T6, and a dynamic improved motion-sensitized driven-equilibrium steady-state free precession (dynamic iMSDE SSFP) sequence revealed an irregular flow of cerebrospinal fluid through the dura at the T5-T6 level. The dural defect was confirmed and sutured through a minimal T5-T6 laminectomy without neurological consequences, and the patient reported mild improvement in gait one year after surgery. Conclusions: A combination of MRI sequences provided the necessary information to confidently perform minimal surgery to repair the dural defect. We recommend coupling a balanced steady-state free precession (SSFP) sequence to provide high resolution, high contrast images of anatomical structures and a dynamic iMSDE SSFP sequence to confirm cerebrospinal fluid motion through the defect.

11.
Neurol Med Chir (Tokyo) ; 60(1): 30-36, 2020 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-31776307

RESUMO

The motion of cerebrospinal fluid (CSF) within the subarachnoid space and ventricles is greatly modulated when propagating synchronously with the cardiac pulse and respiratory cycle and path through the nerves, blood vessels, and arachnoid trabeculae. Water molecule movement that propagates between two spaces via a stoma, foramen, or duct presents increased acceleration when passing through a narrow area and can exhibit "turbulence." Recently, neurosurgeons have started to perform fenestration procedures using neuroendoscopy to treat hydrocephalus and cystic lesions. As part of the postoperative evaluation, a noninvasive diagnostic technique to visualize the water molecules at the fenestrated site is necessary. Because turbulence is observed at this fenestrated site, an imaging technique appropriate for observing this turbulence is essential. We therefore investigated the usefulness of a dynamic improved motion-sensitized driven-equilibrium steady-state free precession (Dynamic iMSDE SSFP) sequence of magnetic resonance imaging that is superior for ascertaining turbulent motions in healthy volunteers and patients. Images of Dynamic iMSDE SSFP from volunteers revealed that CSF motion at the ventral surface of the brainstem and the third ventricle is augmented and turbulent. Moreover, our findings confirmed that this technique is useful for evaluating treatments that utilize neuroendoscopy. As a result, Dynamic iMSDE SSFP, a simple sequence for visualizing CSF motion, entails a short imaging time, can extensively visualize CSF motion, does not require additional processes such as labeling or trigger setting, and is anticipated to have wide-ranging clinical applications in the future.


Assuntos
Líquido Cefalorraquidiano/fisiologia , Imageamento por Ressonância Magnética/métodos , Reologia/métodos , Adolescente , Adulto , Ventrículos Cerebrais , Criança , Pré-Escolar , Cistos/líquido cefalorraquidiano , Feminino , Humanos , Hidrocefalia/líquido cefalorraquidiano , Hidrocefalia/etiologia , Imageamento por Ressonância Magnética/instrumentação , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Pinealoma/complicações , Reologia/instrumentação , Espaço Subaracnóideo , Adulto Jovem
12.
Artigo em Japonês | MEDLINE | ID: mdl-29459537

RESUMO

Synthetic MRI can provide proton density (PD), T1 value, T2 value for each pixel by only one data acquisition and can create various contrast-weighted images. The aim of this study is to evaluate the effect on the calculation of the T1·T2 value when changing the scan parameters for synthetic MRI. In the phantom study, when changing 1st TE/2nd TE/TR/TSE factor, the effect on the T1·T2 value calculated by synthetic MRI was examined. In the volunteer study, the brain was imaged and compared with known T1·T2 value. In phantom study, the effect on the T2 value by the 1st TE/2nd TE/TSE factor was shown. In volunteer study, there was no problem in the calculated value of brain parenchyma. However, the T2 value of cerebrospinal fluid had the error of known value. The results show that it is necessary to set appropriate scan parameters on synthetic MRI.


Assuntos
Imageamento por Ressonância Magnética/métodos , Adulto , Encéfalo/diagnóstico por imagem , Feminino , Humanos , Masculino , Imagens de Fantasmas , Adulto Jovem
13.
Magn Reson Med Sci ; 17(3): 259-264, 2018 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-28835572

RESUMO

We assessed labeling region selectivity on time-spatial labeling inversion pulse (Time-SLIP) with pencil beam pulse (PB Time-SLIP) for the use of visualizing cerebrospinal fluid (CSF) flow dynamics. We compared the selectivity of labeling to the third and fourth ventricles between PB Time-SLIP and conventional Time-SLIP (cTime-SLIP) in eight volunteers and one patient using a 1.5T MRI. PB Time-SLIP provided more selective labeling in CSF than cTime-SLIP, particularly in complex anatomical regions.


Assuntos
Líquido Cefalorraquidiano/diagnóstico por imagem , Líquido Cefalorraquidiano/fisiologia , Hemodinâmica/fisiologia , Imageamento por Ressonância Magnética/métodos , Adulto , Pressão do Líquido Cefalorraquidiano/fisiologia , Humanos , Masculino , Imagens de Fantasmas , Valores de Referência , Reprodutibilidade dos Testes
14.
World Neurosurg ; 97: 523-531, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27474454

RESUMO

BACKGROUND: Many studies have shown that cerebrospinal fluid (CSF) behaves irregularly, rather than with laminar flow, in the various CSF spaces. We adapted a modified previously known magnetic resonance imaging technique to visualize irregular CSF motion. Subsequently, we assessed the usefulness and clinical significance of the present method. MATERIALS AND METHODS: Normal CSF motion in 10 healthy volunteers was visualized with the dynamic improved, motion-sensitized, driven-equilibrium steady-state free precession technique. Subsequently, CSF motion visualization with a modified sequence was applied to 3 patients. RESULTS: In healthy volunteers, we achieved visualization of the irregularity of CSF flow in the ventricles and spinal canal, whereas CSF motion was diminished in the peripheral part of the intracranial subarachnoid space. In one case, we confirmed the patency of the patient's third ventriculostomy fenestration site. In the other, we verified the usefulness of the proposed sequence for determining the communication between the ventricle or subarachnoid space and the cyst. CONCLUSIONS: Using the present sequence, we obtained images that accentuated CSF motion, which is largely composed of irregular motion. This method does not require pulse triggering or complex post-processing of images and allows visualization of CSF motion in a short period of time in selected whole imaging planes. It can therefore be applied clinically to diagnose various diseases that cause abnormalities in the CSF space.


Assuntos
Ventrículos Cerebrais/diagnóstico por imagem , Líquido Cefalorraquidiano/diagnóstico por imagem , Líquido Cefalorraquidiano/fisiologia , Imageamento por Ressonância Magnética/métodos , Reologia/métodos , Espaço Subaracnóideo/diagnóstico por imagem , Adulto , Ventrículos Cerebrais/fisiologia , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Neuroimagem/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espaço Subaracnóideo/fisiologia , Adulto Jovem
16.
Neurol Res ; 36(9): 795-9, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24649808

RESUMO

OBJECTIVES: Atherosclerotic stenosis of the middle cerebral artery (MCA) is one of the causes of ischemic stroke, but aside from investigations using magnetic resonance angiography (MRA), studies evaluating stenosis are rare. The purpose of this study was to assess dynamic changes of MCA cross section between the systolic and diastolic phases in patients with cerebral infarction using 3·0-Tesla magnetic resonance imaging (3T MRI). METHODS: We assessed 12 stroke patients with M1 stenosis in the MCA and 12 healthy volunteers. We measured MCA cross sections (proximal/distal to stenosis and on the stenosis) in the systolic and diastolic phases by synchronizing imaging with heartbeats, as well as the maximum flow velocity by using cine-phase contrast (PC) MRI. Each patient also underwent conventional MRA. RESULTS: Differences in cross sections between systolic and diastolic phases were significantly smaller in the stenosed artery compared to the distal (P < 0·05) and proximal areas (P < 0·01) in stroke patients. The difference in maximal blood velocity between systolic and diastolic phases at the M1 stenosis was significantly larger than that in the area proximal to the stenosis (P < 0·05). DISCUSSION: We clearly demonstrated dynamic cross-sectional changes in the stenotic areas by 3T MRI, suggesting hemodynamic shear stress, which may further enhance MCA atherosclerosis.


Assuntos
Arteriosclerose Intracraniana/patologia , Imageamento por Ressonância Magnética/métodos , Artéria Cerebral Média/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Isquemia Encefálica/patologia , Isquemia Encefálica/fisiopatologia , Constrição Patológica , Feminino , Humanos , Arteriosclerose Intracraniana/fisiopatologia , Angiografia por Ressonância Magnética , Imageamento por Ressonância Magnética/instrumentação , Masculino , Pessoa de Meia-Idade , Artéria Cerebral Média/fisiopatologia , Acidente Vascular Cerebral/patologia , Acidente Vascular Cerebral/fisiopatologia
17.
Artigo em Japonês | MEDLINE | ID: mdl-23358343

RESUMO

The purpose of this study was to investigate the effect of fat suppression when we use respiratory-gated spectral attenuated with inversion recovery (SPAIR) method with respiratory-gated. We experimented on phantom and in-vivo study using simulated wave of respiratory-gated SPAIR at 1.5 tesla and 3.0 tesla. As a result, the effect of fat suppression becomes wrong with longer intervals of inspiration and expiration by wave of respiratory-gated. The signal intensity also varies with each slice. This result had the same trend on phantom and in-vivo study. The longitudinal magnetization of fat becomes a stable state when SPAIR pulse is shot more than once. However, the SPAIR method with respiratory-gated collect signal before the longitudinal magnetization of fat to be stable state, and fat suppression effect becomes bad, because the inversion time does not match the null point of the fat. Therefore, when we use SPAIR method with respiratory-gated it always causes bad fat suppression.


Assuntos
Imageamento por Ressonância Magnética/métodos , Tecido Adiposo , Adulto , Humanos , Imagens de Fantasmas , Respiração
18.
Artigo em Japonês | MEDLINE | ID: mdl-21937843

RESUMO

In 3.0-T magnetic resonance imaging (MRI), shortened radio frequency (RF) wavelengths cause B(1) inhomogeneity. Multi transmit (MT) has been reported as a method of solving this problem. We compared MT with single transmit (ST) and ST body-tuned CLEAR (BTC) in terms of basic performance because we got an opportunity to use MT. A phantom was used to evaluate the uniformity of the flip angles (FAs) of images, the phantom's diameter, and the specific electric conductivity. To evaluate contrast, volunteers performed the significant difference test, and the changes in the FA of the phantom were measured. MT and BTC were better than ST in terms of the uniformity of the images. MT had the best contrast. The results showed that the uniformity of the images and the contrast were improved using MT compared with ST because MT can be uniformly irradiated to an object using two individual RF transmitters.


Assuntos
Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Adulto , Feminino , Humanos , Masculino , Imagens de Fantasmas , Adulto Jovem
19.
Artigo em Japonês | MEDLINE | ID: mdl-21869542

RESUMO

The purpose of this study was to improve the visualization of long-axis black-blood imaging of the carotid arteries. We experimented on phantom and in-vivo study of 3 dimension (3D) inversion recovery T(1) turbo field echo combined with phase sensitive inversion recovery (PSIR-3D IR-T(1)TFE) at 3.0 Tesla. As a result, the contrast has been improved by calculated images of PSIR-3D IR-T(1)TFE set to inversion time (TI) 350 ms that is shorter than null point of blood. This displays that the contrast between blood and tissues can be improved when the longitudinal magnetization of blood is a negative. Therefore, the visualization of long-axis black-blood imaging of the carotid arteries has been improved by the calculated images of PSIR-3D IR-T(1)TFE set to TI that is shorter than null point of blood.


Assuntos
Artérias Carótidas/anatomia & histologia , Imageamento por Ressonância Magnética/métodos , Adulto , Sangue , Humanos , Imagens de Fantasmas
20.
Jpn J Radiol ; 29(1): 25-32, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21264658

RESUMO

PURPOSE: The aim of this study was to assess the feasibility of using intravenously administered gadofosveset trisodium as a negative contrast agent for lymph node (LN) assessment with diffusion-weighted imaging (DWI) using a VX2 tumor model in rabbits. MATERIALS AND METHODS: VX2 cells were injected in the right hind limb of five Japanese white rabbits to induce ipsilateral popliteal LN metastasis. DWI was performed before and every 7.5 min (until 1 h) after intravenous gadofosveset trisodium administration, at 1.5 T. Signal intensities (SIs) of right (metastatic) and left (nonmetastatic) popliteal LNs at each time point were measured and compared to each other using two-sided unpaired t-tests. RESULTS: The SIs of metastatic lymph nodes were significantly higher (P < 0.05) than those of nonmetastatic LNs at each time point after intravenous gadofosveset trisodium administration. Although the SI of metastatic LNs was significantly higher (P = 0.0237) than that of nonmetastatic LNs before contrast injection, this difference became even more significant (P ≤ 0.0105) after gadofosveset trisodium administration. CONCLUSION: The SI of metastatic LNs at DWI is less suppressed than that of nonmetastatic LNs after the intravenous administration of gadofosveset trisodium. Therefore, intravenously administered gadofosveset trisodium shows promise for use as a negative contrast agent for discriminating metastatic from nonmetastatic LNs at DWI.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Metástase Linfática/patologia , Neoplasias Experimentais/patologia , Animais , Meios de Contraste/administração & dosagem , Estudos de Viabilidade , Gadolínio/administração & dosagem , Linfonodos/patologia , Masculino , Compostos Organometálicos/administração & dosagem , Coelhos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...