Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
1.
Eur Heart J Case Rep ; 8(1): ytae015, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38239310

RESUMO

Background: Duration and dosage of thrombolysis for ultrasound-assisted catheter-directed thrombolysis (UACDT) in patients with intermediate high-risk pulmonary embolism remain controversial and treatment protocols vary. Case summary: A 58-year-old female patient suffered from a right-sided urolithiasis. The clinical course was complicated by an intermediate high-risk pulmonary embolism [pulmonary embolism severity index (PESI) score 108 points and simplified PESI ≥1] with bilateral proximal thrombus and significant right heart dysfunction. The pulmonary embolism response team (PERT) made a decision towards UACDT. The standard duration of UACDT ranges between 6 and 15 h depending on clinical parameters. In this particular case, the clinical parameters such as heart rate (no tachycardia) or oxygen saturation (chronic obstructive pulmonary disease) might lead to premature termination of UACDT. Therefore, PERT decided to additionally monitor pulmonary artery pressure (PAP) continuously during the UACDT via a separate pigtail catheter in the pulmonary artery. Ultrasound-assisted catheter-directed thrombolysis was performed using 1 mg/h recombinant tissue plasminogen activator (rtPA) per catheter, while PAP was registered continuously. Heart rate and oxygen saturation remained unchanged during UACDT. However, after 6 h of UACDT, systolic PAP decreased slightly from 62 to 55 mmHg and therapy was prolonged to 15 h. Pulmonary artery pressure dropped to 46 mmHg after 15 h. The patient was discharged from hospital at Day 7, and echocardiography revealed no signs of right heart dysfunction. Discussion: Dosage of the thrombolysis agent and duration of UACDT are still a matter of debate. Besides clinical parameters and transthoracic echocardiography, invasive real-time PAP monitoring during UACDT could facilitate important information for therapy guidance in selected cases.

2.
J Interv Card Electrophysiol ; 67(3): 571-577, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37612562

RESUMO

BACKGROUND: Fibrotic atrial cardiomyopathy plays an important role in determining the outcome of ablation in patients with atrial fibrillation (AF). Two main methods are being used for the evaluation of fibrosis: voltage-based high-density (HD) electroanatomical mapping (EAM) and late gadolinium enhancement MRI (LGE-MRI). The comparability between both methods in detecting fibrosis has not been systematically investigated. METHODS: LGE-MRIs of the left atrium (LA) were performed in 21 patients. LA-fibrosis was evaluated using a custom-designed software generating a 3D-model of the LA. HD-electroanatomical maps were recorded in each patient. After processing the maps and the MRI models by excluding the mitral valve, pulmonary veins, and the left atrial appendage, the LGE areas were measured and compared to the low voltage areas (LVA) in the HD maps using three different cutoff values of 0.5 mV, 0.7 mV, and 1.0 mV. RESULTS: The analysis revealed significant differences between EAM and LGE-MRI in assessing LA-fibrosis at 0.5-mV (for anterior and posterior walls) and 1.0-mV cutoffs (for anterior and posterior wall and septum). However, no significant differences were found between EAM and LGE-MRI when using a 0.7-mV cutoff for all the investigated areas. CONCLUSIONS: A voltage cutoff of 0.7 mV provided the best correlation between EAM and LGE MRI for detecting left atrial fibrosis. It supports the idea that a 0.5-mV cutoff may underestimate fibrosis, as areas with local signal voltages between 0.6 and 0.8 mV could also show LGE on MRI. Further research is needed to determine the ideal voltage cutoff for detecting left atrial fibrosis.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Gadolínio , Meios de Contraste , Imageamento por Ressonância Magnética/métodos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Átrios do Coração/diagnóstico por imagem , Fibrose , Ablação por Cateter/métodos
3.
Eur Heart J Open ; 3(1): oead004, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36820238

RESUMO

Patients with atrial fibrillation may require rhythm control therapy in addition to anticoagulation therapy for the prevention of stroke. Since 2012, the European Society of Cardiology and European Heart Rhythm Association guidelines have recommended non-vitamin K antagonist oral anticoagulants, including rivaroxaban, for the prevention of stroke in patients with atrial fibrillation. During the same period, these guidelines have also recommended dronedarone or amiodarone as second-line rhythm control agents in certain patients with atrial fibrillation and no contraindications. Amiodarone and dronedarone both strongly inhibit P-glycoprotein, while dronedarone is a moderate and amiodarone a weak inhibitor of cytochrome P450 3A4 (CYP3A4). Based on these data and evidence from physiologically based pharmacokinetic modelling, amiodarone and dronedarone are expected to have similar effects on rivaroxaban exposure resulting from P-glycoprotein and CYP3A4 inhibition. However, the rivaroxaban label recommends against the concomitant use of dronedarone, but not amiodarone, citing a lack of evidence on the concomitant use of rivaroxaban and dronedarone as the reason for the different recommendations. In this report, we discuss evidence from clinical studies and physiologically based pharmacokinetic modelling on the potential for increased rivaroxaban exposure resulting from drug-drug interaction between rivaroxaban and dronedarone or amiodarone. The current evidence supports the same clinical status and concomitant use of either amiodarone or dronedarone with rivaroxaban, which could be considered in future recommendations.

4.
J Arrhythm ; 37(5): 1270-1277, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34621425

RESUMO

BACKGROUND: Fast anatomical mapping (FAM) of the left atrium and pulmonary veins (PV) during PV isolation (PVI) generates anatomical information about the carina region additionally. We aimed to investigate the utility of these data in relation to conduction abilities of the intervenous carina. METHODS: We investigated 71 patients with drug-refractory atrial fibrillation (AF) who underwent first-time circumferential PVI using an electroanatomical mapping system. Carina width between ipsilateral PV was measured using FAM and an integrated distance measurement tool. Encirclings were divided into carina ablation and noncarina ablation groups based on the necessity of carina ablation to achieve PVI. RESULTS: In total, 142 encirclings were analyzed and first-pass isolation was observed in 102 (72%) encirclings. Nonfirst-pass PVI solely due to a gap on the line or persistent carina conduction was observed in 10 (7%) and 30 (21%) encirclings, respectively. Encirclings were classified into a carina ablation group (n = 30, 21%) and noncarina ablation group (n = 112, 79%). Carina width was significantly larger in the carina ablation vs nonarina ablation group (right: 11.9 ± 1.5 mm vs 8 ± 1.4 mm, P < .001/left: 12.1 ± 1.3 mm vs 8.1 ± 1.1 mm, P < .001) requiring additional carina ablation. CONCLUSION: Carina-related PV conduction is a common finding after the first-pass ablation during PVI. Measurement of carina width using FAM is feasible and its value correlates with the necessity of carina ablation to achieve PVI.

5.
Open Heart ; 8(1)2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-34006505

RESUMO

OBJECTIVES: The presence of coronary artery disease (CAD) in patients hospitalised with paroxysmal or first diagnosed atrial fibrillation (AF) has major implications for antithrombotic therapy and cardiovascular event rate. Coronary CT angiography (CCTA) is a feasible tool to identify patients with concealed CAD. We aimed to evaluate the diagnostic role of early CCTA in patients hospitalised with paroxysmal or first diagnosed AF. METHODS: In a 5-year single-centre retrospective analysis, 566 patients with paroxysmal or first diagnosed AF who underwent CCTA were enrolled to investigate the presence of CAD. RESULTS: In patients with paroxysmal or first diagnosed AF, CCTA revealed CAD (coronary artery stenosis ≥50%) in 39.2%. Cardiac catheterisation was performed in 31.6%, confirming CAD in 13.1% of all patients. In 8.0% percutaneous coronary intervention and in 0.5% coronary artery bypass grafting was performed. In patients with paroxysmal or first diagnosed AF: (1) angina pectoris per se does not predict CAD; (2) multivariable regression analysis revealed age, male sex and diabetes as risk factors for CAD in AF; (3) Framingham Risk Score for coronary heart disease and CHA2DS2-VASc-Score were relevant risk scores of CAD and (4) the classification of Coronary Artery Calcium score reference values according to the Multi-Ethnic Study of Atherosclerosis was a predictor of CAD. CONCLUSION: Patients with paroxysmal or first diagnosed AF are at risk for CAD, while CCTA is a feasible diagnostic tool for CAD. We recommend to integrate CT calcium scoring and CCTA into the diagnostic workup of patients with new-onset or paroxysmal AF.


Assuntos
Fibrilação Atrial/diagnóstico , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico , Medição de Risco/métodos , Taquicardia Paroxística/diagnóstico , Idoso , Fibrilação Atrial/complicações , Doença da Artéria Coronariana/complicações , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Masculino , Estudos Retrospectivos , Fatores de Risco
6.
Front Cardiovasc Med ; 8: 810054, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35071369

RESUMO

Background: Infective endocarditis (IE) following mitral valve edge-to-edge repair is a rare complication with high mortality. Case summary: A 91-year-old male patient was admitted to intensive care unit with sepsis due to urinary tract infection after insertion of a urinary catheter by the outpatient urologist. Two weeks ago, the patient was discharged from hospital after successful transcatheter edge-to-edge mitral valve repair (TEER) using a PASCAL Ace device. The initially withdrawn blood revealed repeatedly Proteus mirabilis bacteremia as causal for the sepsis due to urinary tract infection. An antibiotic regime with Ampicillin/Sulbactam was initiated and discontinued after 7 days. During the clinical course the patient again developed fever and blood cultures again revealed P. mirabilis. In transesophageal echocardiography (TOE), IE of the PASCAL Ace device was confirmed by a vegetation accompanied by a mild to moderate mitral regurgitation. While the patient was stable at this time and deemed not suitable for cardiac surgery, the endocarditis team made a decision toward a prolonged 6-week antibiotic regime with an antibiotic combination of Ampicillin 2 g qds and Ciprofloxacin 750 mg td. Due to posterior leaflet perforation severe mitral regurgitation developed while PASCAL Ace vegetations were significantly reduced by the antibiotic therapy. Therefore, the patient underwent successful endoscopic mitral valve replacement. Another 4 weeks of antibiotic treatment with Ampicillin 2 g qds followed before the patient was discharged. Discussion: P. mirabilis is able to form biofilms, resulting in a high risk for endocarditis following transcatheter mitral valve repair especially when device endothelization is incomplete. Endoscopic mitral valve replacement could serve as a bailout strategy in refractory Clip-endocarditis.

7.
PLoS One ; 14(5): e0214231, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31050677

RESUMO

PURPOSE: Data on bonus freeze characteristics and their impact on complication rates and long-term clinical outcome are limited. METHODS: Pulmonary vein isolation (PVI) using a 28 mm 2nd-generation cryoballoon (CB) was performed in 169 patients (pts). The isolation temperatures, time to isolation and minimal temperatures of the cryoapplications were documented. RESULTS: The study included 92 pts who received one bonus freeze after PVI in group I and 77 pts who did not receive a bonus freeze in group II. After a mean follow-up time of 19.0±8.6 months in group I and 16.4±7.5 months in group II, 67 of 92 pts (72.8%) and 49 of 75 pts available to follow up (65.3%; p = 0.221) were free of atrial tachyarrhythmia, respectively. Phrenic nerve palsy occurred in 5.4% of the pts in group I (5/92 pts) and 1.3% of the pts in group II (1/77 pts; p = 0.22). Both the mean nadir temperatures of the bonus freezes and mean nadir temperatures of the isolation freezes differed significantly between the recurrent and non-recurrent pts in group I. The predilection sites of the reconduction for both groups were the inferior aspect of the inferior pulmonary veins. CONCLUSION: The impact of a bonus freeze on long-term clinical outcome was not significant for two reasons: 1) The necessity of a bonus freeze was low because the long-term clinical success rate without a bonus freeze was high; and 2) the majority of bonus freezes, especially at the predilection sites, such as the inferior PV, appeared to be ineffective.


Assuntos
Fibrilação Atrial/cirurgia , Criocirurgia/métodos , Idoso , Fibrilação Atrial/diagnóstico , Biomarcadores , Ablação por Cateter/métodos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Recidiva , Retratamento , Estudos Retrospectivos , Temperatura , Fatores de Tempo , Resultado do Tratamento
10.
Diabetol Metab Syndr ; 8(1): 57, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27555885

RESUMO

BACKGROUND: The treatment and prevention of the metabolic syndrome (MetS) is currently one of the major challenges in medicine. The impact of working conditions on metabolic risk has not been adequately studied. Our objective was to compare the prevalence of MetS and metabolic risk in two extremely different occupational groups: firefighters and office workers. METHODS: A total of 143 male subjects (97 firefighters and 46 office workers) from Germany participated in the study. Anthropometric characteristics, metabolic risk parameters as well as laboratory parameters were collected. MetS was diagnosed according to criteria of the International Diabetes Federation. RESULTS: Sedentary occupation showed a significant tendency towards obesity. Abdominal waist circumference was significantly greater in office workers than in firefighters [5.08 CI (1.44-8.71), p = 0.007]. Concerning metabolic risk factors, abnormal HDL, triglycerides, BMI, blood pressure and waist circumference values were more frequently found in office workers than in firefighters. The MetS was detected in almost 33 % of office workers as compared with only 14 % in firefighters (p = 0.015). Regarding MetS in an international comparison, the prevalence of MetS in German office workers was high and in firefighters it was extremely low. CONCLUSIONS: Sedentary occupation as an office worker is associated with a high risk of MetS. Both groups need to be made aware of the metabolic risks, and health promoting concepts such as corporate sports activities or education in healthy nutrition need to be implemented to counteract the development of the MetS and cardiovascular risk factors.

11.
J Interv Card Electrophysiol ; 47(1): 91-98, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27189156

RESUMO

PURPOSE: In this study, we aimed to report our preliminary experience regarding the impact of the novel short-tip (ST) cryoballoon (CB) on procedural efficacy and signal quality during pulmonary vein (PV) isolation for both paroxysmal and persistent atrial fibrillation. METHODS: Between March, 2015, and August, 2015, we enrolled a total of 64 patients (47 patients male, 73 %) with a mean age of 60 ± 11 years. In the study population, 31 patients (48 %) underwent PVI using Advance (ADV) CB and 33 (52 %) patients with ST CB. In all patients, a 28-mm balloon was used. RESULTS: Acute procedural success rates were 100 % for the entire study population. A statistically insignificant increase in the percentage of PV signal recordings was observed with ST CB in all PVs compared to ADV CB [88 vs. 81 % for left superior PV (LSPV), 82 vs. 78 % for left inferior PV (LIPV), 85 vs. 84 % for right superior PV (RSPV), 82 vs. 71 % for right inferior PV (RIPV), p < 0.05]. Additionally, the difference in minimum temperature reached during the procedure per PV was not statistically significant between ST CB and ADV CB except the LIPV (LSPV -44.2 ± 5.9 vs. -45.6 ± 5.3 °C, p = 0.970; LIPV -38.7 ± 4.6 °C vs -44.6 ± 6.8 °C, p < 0.001; RSPV -45.6 ± 7.4 °C vs.-47.2 ± 6.1 °C, p = 0.168; RIPV -41.4 ± 5.1 °C vs.-43.7 ± 6.3 °C, p = 0.360). Time to isolation for each PV was similar between ST and ADV CB (p > 0.05). CONCLUSION: Our preliminary findings indicated similar acute procedural success for the novel ST CB compared with second generation ADV CB. The increase in the ratio of PV signal recordings obtained during the PVI using the novel ST CB was not significant.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Mapeamento Potencial de Superfície Corporal/instrumentação , Cateteres Cardíacos , Criocirurgia/instrumentação , Veias Pulmonares/cirurgia , Mapeamento Potencial de Superfície Corporal/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento , Procedimentos Cirúrgicos Vasculares/instrumentação
13.
Pacing Clin Electrophysiol ; 39(5): 434-42, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26910475

RESUMO

BACKGROUND: Second-generation cryoballoon (CB-2) is associated with improved outcomes for pulmonary vein isolation (PVI) compared to first generation (CB-1). However, data regarding the predictors of pulmonary vein (PV) electrical reconnection are limited. In this study, we aimed to characterize the predilection sites and predictors of reconnection in patients with recurrent atrial tachyarrhythmia (ATa) after PVI using CB-1 and CB-2. METHODS: A total of 59 patients (mean age: 62 ± 11 years and 66% male) with recurrent ATa after previous CB-PVI, using either a 28-mm CB-1 or CB-2, underwent repeat ablation. PV reisolation was performed by irrigated radiofrequency ablation using three-dimensional electroanatomical mapping systems. RESULTS: Electrical PV reconnection was detected in 10 of 11 (91%) of CB-1 patients compared to 41 of 48 (85%) of CB-2 patients. Time to redo procedure after index CB-1 was 8.9 ± 10.2 months and 11.2 ± 7.0 months in CB-2. Bonus freeze was applied in all patients with CB-1 and 41% of the patients with CB-2. Superior quadrants of both superior PVs and inferior quadrants of the both inferior PVs exhibited higher predilection for conduction compared to other quadrants (P < 0.001). Multivariate binary logistic analysis revealed that right inferior PV (RIPV; odds ratio [OR]: 1.52, 95% confidence interval [CI]: 1.09-2.13, P = 0.014) and minimum temperature (OR: 1.09, 95% CI: 1.03-1.15, P = 0.004) were the independent predictors of electrical reconnection after CB-2 ablation. CONCLUSION: Conduction gaps after CB-1 and CB-2 were higher in inferior PVs compared to superior PVs. The RIPV and minimum CB temperature were independent predictors of PV electrical reconnection after CB-2.


Assuntos
Fibrilação Atrial/cirurgia , Criocirurgia/instrumentação , Veias Pulmonares/fisiologia , Veias Pulmonares/cirurgia , Técnicas Eletrofisiológicas Cardíacas , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Estudos Retrospectivos
14.
Cardiovasc Ther ; 34(3): 144-51, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26880220

RESUMO

AIM: Data evaluating the complications of pulmonary vein isolation (PVI) using second-generation cryoballoons (CB) related to different anticoagulation regimes are limited. This study evaluates the total complications and the impact of novel oral anticoagulants (NOACs) compared to phenprocoumon on adverse events in the setting of PVI using CB. METHODS AND RESULTS: PVI was performed using second-generation CB by two experienced investigators. A total of 409 patients (58.9% male; mean age = 61 ± 10 years) with atrial fibrillation were included in this study. In group I, 150/409 (36.7%) patients received phenprocoumon therapy, and in group II, 259/409 (63.3%) patients were treated with NOACs (rivaroxaban: n = 193; dabigatran: n = 48; and apixaban: n = 18). In both groups, the rates of major complications were similar (group I [phenprocoumon]: four pts (2.7%) vs. Group II [NOACs]: seven pts (2.7%); P = 0.999). In this cohort, 275 patients were ablated with the bonus freeze protocol, and 134 patients were ablated without bonus freezes. The procedure duration significantly decreased with the bonus freeze protocol from 102.3 ± 24.6 min to 68.5 ± 16.2 min (P < 0.001). The impact of the bonus freeze on the postprocedural increase of C-reactive protein (CRP) levels was significant compared to the postprocedural CRP levels after procedures without the bonus freeze protocol (postprocedural CRP level+ bonus protocol: 1.6 ± 1.2 mg/L vs. postprocedural CRP level+ nonbonus protocol: 1.3 ± 1.3 mg/L; P = 0.04). CONCLUSION: The incidence of adverse events in PVI using the second-generation CB with the periprocedural administration of NAOCs was not significantly different compared to phenprocoumon. Further, large-scale randomized studies are needed to evaluate the safety of two anticoagulation regimes comparing vitamin K antagonists and NOACs, as well as different NOAC regimes, in patients undergoing PVI using cryoballoon ablation.


Assuntos
Anticoagulantes/administração & dosagem , Fibrilação Atrial/cirurgia , Criocirurgia/efeitos adversos , Dabigatrana/administração & dosagem , Femprocumona/administração & dosagem , Complicações Pós-Operatórias/epidemiologia , Veias Pulmonares/cirurgia , Pirazóis/administração & dosagem , Piridonas/administração & dosagem , Rivaroxabana/administração & dosagem , Administração Oral , Idoso , Anticoagulantes/efeitos adversos , Fibrilação Atrial/sangue , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Biomarcadores/sangue , Criocirurgia/instrumentação , Criocirurgia/métodos , Dabigatrana/efeitos adversos , Feminino , Alemanha/epidemiologia , Humanos , Incidência , Mediadores da Inflamação/sangue , Masculino , Pessoa de Meia-Idade , Femprocumona/efeitos adversos , Complicações Pós-Operatórias/sangue , Complicações Pós-Operatórias/diagnóstico , Pirazóis/efeitos adversos , Piridonas/efeitos adversos , Estudos Retrospectivos , Rivaroxabana/efeitos adversos , Resultado do Tratamento
15.
World J Diabetes ; 7(3): 45-9, 2016 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-26862372

RESUMO

The incidence of diabetes mellitus (DM) is increasing rapidly. DM is the leading cause of cardiovascular diseases, which can lead to varied cardiovascular complications by aggravated atherosclerosis in large arteries and coronary atherosclerosis, thereby grows the risk for macro and microangiopathy such as myocardial infarction, stroke, limb loss and retinopathy. Moreover diabetes is one of the strongest and independent risk factor for cardiovascular morbidity and mortality, which is associated frequently with rhythm disorders such as atrial fibrillation (AF) and ventricular arrhythmias (VA). The present article provides a concise overview of the association between DM and rhythm disorders such as AF and VA with underlying pathophysiological mechanisms.

16.
Cardiovasc Ther ; 34(1): 49-56, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26607305

RESUMO

AIM: Rotational angiography is a well-known method for the three-dimensional (3-D) reconstruction of left atrium and pulmonary veins during left-sided atrial arrhythmia ablation procedures. In our study, we aimed to review our experience in transseptal puncture (TSP) using 3-D rotational angiography. METHODS: We included a total of 271 patients who underwent atrial fibrillation ablation using cryoballoon. Rotational angiography was performed to get the three-dimensional left atrial and pulmonary vein reconstructions using cardiac C-arm computed tomography. The image reconstruction was made using the DynaCT Cardiac software (Siemens, Erlangen, Germany). RESULTS: The mean age of the study population was 61 ± 10 years. The indications for left atrial arrhythmia ablation were paroxysmal AF in 140 patients (52%) and persistent AF patients in 131 (48%) patients. The success rate of TSP using only rotational guidance was (264/271 patients, 97.4%). In the remaining seven patients, transesophageal guidance was used after the initial attempt due to thick interatrial septum in five patients and difficult TSP due to abnormal anatomy and mild pericardial effusion in the remaining two patients. Mean fluoroscopy dosage of the rotational angiography was 4896.4 ± 825.3 µGym(2). The mean time beginning from femoral vein puncture to TSP was 12.3 ± 5.5 min. CONCLUSION: TSP guided by rotational angiography is a safe and effective method. Our results indicate that integration of rotational angiographic images into the real-time fluoroscopy can guide the TSP during the procedure.


Assuntos
Angiografia/métodos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Cateterismo Cardíaco/métodos , Criocirurgia , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Imageamento Tridimensional , Radiografia Intervencionista/métodos , Tomografia Computadorizada por Raios X , Idoso , Ecocardiografia Transesofagiana , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Punções , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Software
18.
Circ Arrhythm Electrophysiol ; 8(5): 1073-9, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26286935

RESUMO

BACKGROUND: Data regarding the freedom from atrial fibrillation (AF) in the follow-up of persistent AF patients is limited. The second-generation cryoballoon has better cooling properties compared with first-generation cryoballon. In this study, we aimed to assess the medium-term efficacy of second-generation cryoballoon in patients with persistent AF. METHODS AND RESULTS: A total of 100 patients (63±10 years, 80% male) with symptomatic persistent AF, despite ≥1 antiarrhythmic drug(s), who were scheduled for pulmonary vein isolation using second-generation cryoballoon were enrolled in this study. Follow-up was based on outpatient clinic visits, including Holter ECGs. Recurrence was defined as a symptomatic or documented arrhythmia episode of >30 seconds excluding a 3-month blanking period. As a result, 393 pulmonary veins (7 patients with common ostium) were successfully isolated. Mean procedural and fluoroscopy times were 96.2±21.3 and 19.7±6.7 minutes, respectively. Phrenic nerve palsy occurred in 3% (3/100) of the patients. At a mean follow-up duration of 10.6±6.3 months, 67% of the patients were in sinus rhythm. Stepwise multivariable Cox proportional hazard regression analysis showed that early AF recurrence (hazard ratio 3.83, 95% confidence interval 1.91-7.68, P<0.001) was the only independent predictor for late AF recurrence apart from other clinical and echocardiographic variables. CONCLUSIONS: Our findings indicated that second-generation cryoballoon use is associated with favorable outcomes in patients with persistent AF. Recurrence at blanking period was the only predictor of long-term AF recurrence.


Assuntos
Fibrilação Atrial/cirurgia , Criocirurgia/instrumentação , Veias Pulmonares/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Ecocardiografia , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Veias Pulmonares/diagnóstico por imagem , Resultado do Tratamento
19.
Biomed Res Int ; 2015: 765921, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26236735

RESUMO

Left atrial (LA) functional analysis has an established role in assessing left ventricular diastolic function. The current standard echocardiographic parameters used to study left ventricular diastolic function include pulsed-wave Doppler mitral inflow analysis, tissue Doppler imaging measurements, and LA dimension estimation. However, the above-mentioned parameters do not directly quantify LA performance. Deformation studies using strain and strain-rate imaging to assess LA function were validated in previous research, but this technique is not currently used in routine clinical practice. This review discusses the history, importance, and pitfalls of strain technology for the analysis of LA mechanics.


Assuntos
Função do Átrio Esquerdo , Ecocardiografia Doppler de Pulso , Função Ventricular Esquerda , Animais , Ecocardiografia Doppler de Pulso/história , Ecocardiografia Doppler de Pulso/métodos , Átrios do Coração/diagnóstico por imagem , História do Século XIX , História do Século XX , História do Século XXI , Humanos
20.
PLoS One ; 10(7): e0133113, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26186442

RESUMO

BACKGROUND: This study examined the association between the physical work environment and physiological performance measures, physical activity levels and metabolic parameters among German civil servants. A main focus in this study was to examine the group differences rather than measuring the absolute values in an occupational group. METHODS: We prospectively examined 198 male German civil servants (97 firefighters [FFs], 55 police officers [POs] and 46 sedentary clerks [SCs]). For each parameter, the groups were compared using a linear regression adjusted for age. RESULTS: The 97 FFs showed a similar maximal aerobic power (VO2max l/min) of 3.17±0.44 l/min compared with the POs, who had a maximal aerobic power of 3.13±0.62 l/min (estimated difference, POs vs. FFs: 0.05, CI: -0.12-0.23, p=0.553). The maximal aerobic power of the FFs was slightly higher than that of the SCs, who had a maximal aerobic power of 2.85±0.52 l/min (-0.21, CI: -0.39-0.04, p=0.018 vs. FFs). The average physical activity (in metabolic equivalents [METS]/week) of the FFs was 3953±2688, whereas those of the POs was 2838±2872 (vs. FFs: -985, CI: -1941-30, p = 0.043) and of the SCs 2212±2293 (vs. FFs: -1598.8, CI: -2477-721, p = 0.000; vs. POs: -613.6, CI: -1617.4­390.3, p = 0.229), respectively [corrected]. For the FFs, the average body fat percentage was 17.7%±6.2, whereas it was 21.4%±5.6 for the POs (vs. FFs: 2.75, CI: 0.92-4.59, p=0.004) and 20.8%±6.5 for the SCs (vs. FFs: 1.98, CI: -0.28-4.25, p=0.086; vs. POs: -0.77, CI: 3.15-1.61, p=0.523). The average waist circumference was 89.8 cm±10.0 for the FFs, 97.8 cm±12.4 (5.63, CI: 2.10-9.15, p=0.002) for the POs, and 97.3±11.7 (vs. FFs: -4.89, CI: 1.24-8.55, p=0.009; vs. POs: -0.73, CI: -5.21-3.74, p=0.747) for the SCs. CONCLUSIONS: The FFs showed significantly higher physical activity levels compared with the SCs. The PO group had the highest cardiovascular risk of all of the groups because it included more participants with metabolic syndrome; furthermore, the POs had an average of 2.75% higher body fat, lower HDL cholesterol values and higher waist circumferences compared with the FFs and higher LDL cholesterol values compared with the SCs. Our data indicate that sedentary occupations appear to be linked to obesity and metabolic syndrome in middle-aged men.


Assuntos
Bombeiros , Atividade Motora , Polícia , Metabolismo Energético , Alemanha , Humanos , Masculino , Síndrome Metabólica/epidemiologia , Síndrome Metabólica/etiologia , Estudos Prospectivos , Vigilância em Saúde Pública , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...