Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Langenbecks Arch Surg ; 409(1): 108, 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38570375

RESUMO

PURPOSE: Intraabdominal infections (IAI) are increasing worldwide and are a major contributor to morbidity and mortality. Among IAI, the number of multi-drug resistant organisms (MDRO) is increasing globally. We tested the Unyvero A50® for intraabdominal infections, compared the detected microorganisms and antibiotic resistance, and compared the results with those of routine microbiology. METHODS: We prospectively compared samples obtained from surgical patients using PCR-based Unyvero IAI cartridges against routine microbiology for the detection of microorganisms. Additionally, we identified clinical parameters that correlated with the microbiological findings. Data were analyzed using the t-test and Mann-Whitney U test. RESULTS: Sixty-two samples were analyzed. The PCR system identified more microorganisms, mostly Bacteroides species, Escherichia coli, and Enterococcus spp. For bacterial resistance, the PCR system results were fully concordant with those of routine microbiology, resulting in a sensitivity, specificity, and positive and negative predictive value (PPV, NPV) of 100%. The sensitivity, specificity, PPV, and NPV for the detection of microorganisms were 74%, 58%, 60%, and 72%, respectively. CRP levels were significantly higher in patients with detectable microorganisms. We identified more microorganisms and bacterial resistance in hospital-acquired intra-abdominal infections by using the PCR system. DISCUSSION: IAI warrants early identification of the microorganisms involved and their resistance to allow for adequate antibiotic therapy. PCR systems enable physicians to rapidly adjust their antibiotic treatment. Conventional microbiological culture and testing remain essential for determining the minimal growth inhibition concentrations for antibiotic therapy.


Assuntos
Infecção Hospitalar , Infecções Intra-Abdominais , Humanos , Infecções Intra-Abdominais/diagnóstico , Infecções Intra-Abdominais/tratamento farmacológico , Antibacterianos/uso terapêutico , Valor Preditivo dos Testes , Infecção Hospitalar/diagnóstico , Infecção Hospitalar/tratamento farmacológico , Reação em Cadeia da Polimerase
2.
J Appl Clin Med Phys ; 25(1): e14249, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38128056

RESUMO

To account for intra-fractional tumor motion during dose delivery in radiotherapy, various treatment strategies are clinically implemented such as breathing-adapted gating and irradiating the tumor during specific breathing phases. In this work, we present a comprehensive phantom-based end-to-end test of breathing-adapted gating utilizing surface guidance for use in particle therapy. A commercial dynamic thorax phantom was used to reproduce regular and irregular breathing patterns recorded by the GateRT respiratory monitoring system. The amplitudes and periods of recorded breathing patterns were analysed and compared to planned patterns (ground-truth). In addition, the mean absolute deviations (MAD) and Pearson correlation coefficients (PCC) between the measurements and ground-truth were assessed. Measurements of gated and non-gated irradiations were also analysed with respect to dosimetry and geometry, and compared to treatment planning system (TPS). Further, the latency time of beam on/off was evaluated. Compared to the ground-truth, measurements performed with GateRT showed amplitude differences between 0.03 ± 0.02 mm and 0.26 ± 0.03 mm for regular and irregular breathing patterns, whilst periods of both breathing patterns ranged with a standard deviation between 10 and 190 ms. Furthermore, the GateRT software precisely acquired breathing patterns with a maximum MAD of 0.30 ± 0.23 mm. The PCC constantly ranged between 0.998 and 1.000. Comparisons between TPS and measured dose profiles indicated absolute mean dose deviations within institutional tolerances of ±5%. Geometrical beam characteristics also varied within our institutional tolerances of 1.5 mm. The overall time delays were <60 ms and thus within both recommended tolerances published by ESTRO and AAPM of 200 and 100 ms, respectively. In this study, a non-invasive optical surface-guided workflow including image acquisition, treatment planning, patient positioning and gated irradiation at an ion-beam gantry was investigated, and shown to be clinically viable. Based on phantom measurements, our results show a clinically-appropriate spatial, temporal, and dosimetric accuracy when using surface guidance in the clinical setting, and the results comply with international and institutional guidelines and tolerances.


Assuntos
Neoplasias Pulmonares , Respiração , Humanos , Simulação por Computador , Movimento (Física) , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/patologia , Imagens de Fantasmas , Tomografia Computadorizada por Raios X
3.
Eur J Neurosci ; 57(2): 324-350, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36509461

RESUMO

Conducting constitutes a well-structured system of signs anticipating information concerning the rhythm and dynamic of a musical piece. Conductors communicate the musical tempo to the orchestra, unifying the individual instrumental voices to form an expressive musical Gestalt. In a functional magnetic resonance imaging (fMRI) experiment, 12 professional conductors and 16 instrumentalists conducted real-time novel pieces with diverse complexity in orchestration and rhythm. For control, participants either listened to the stimuli or performed beat patterns, setting the time of a metronome or complex rhythms played by a drum. Activation of the left superior temporal gyrus (STG), supplementary and premotor cortex and Broca's pars opercularis (F3op) was shared in both musician groups and separated conducting from the other conditions. Compared to instrumentalists, conductors activated Broca's pars triangularis (F3tri) and the STG, which differentiated conducting from time beating and reflected the increase in complexity during conducting. In comparison to conductors, instrumentalists activated F3op and F3tri when distinguishing complex rhythm processing from simple rhythm processing. Fibre selection from a normative human connectome database, constructed using a global tractography approach, showed that the F3op and STG are connected via the arcuate fasciculus, whereas the F3tri and STG are connected via the extreme capsule. Like language, the anatomical framework characterising conducting gestures is located in the left dorsal system centred on F3op. This system reflected the sensorimotor mapping for structuring gestures to musical tempo. The ventral system centred on F3Tri may reflect the art of conductors to set this musical tempo to the individual orchestra's voices in a global, holistic way.


Assuntos
Conectoma , Gestos , Humanos , Encéfalo , Imageamento por Ressonância Magnética , Idioma , Mapeamento Encefálico/métodos
4.
Cancers (Basel) ; 14(11)2022 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-35681665

RESUMO

Neuroendocrine carcinoma of the pancreas (pNEC) is an aggressive form of neuroendocrine tumor characterized by a rising incidence without an increase in survival rates. GP-2250 is an oxathiazinane derivate possessing antineoplastic effects, especially in combination with Gemcitabine on the pancreatic adenocarcinoma. The cytotoxic effects of the monotherapy of GP-2250 (GP-2250mono) and Gemcitabine (Gemmono), as well as the combination therapy of both, were studied in vitro using an MTT-assay on the QGP-1 and BON-1 cell lines, along with in vivo studies on a murine xenograft model of QGP-1 and a patient-derived xenograft model (PDX) of Bo99. In vitro, Gemmono and GP-2250mono showed a dose-dependent cytotoxicity. The combination of GP-2250 and Gemcitabine exhibited highly synergistic effects. In vivo, the combination therapy obtained a partial response in QGP-1, while GP-2250mono and Gemmono showed progressive disease or stable disease, respectively. In Bo99 PDX, the combination therapy led to a partial response, while the monotherapy resulted in progressive disease. No development of secondary resistances was observed, as opposed to monotherapy. This study was the first to evaluate the effects of the emerging substance GP-2250 on pNEC. The substance showed synergism in combination with Gemcitabine. The combination therapy proved to be effective in vitro and in vivo, without the development of secondary resistances.

5.
Phys Med Biol ; 67(6)2022 03 16.
Artigo em Inglês | MEDLINE | ID: mdl-35226890

RESUMO

Objective. The aim of this work is an AI based approach to reduce the volume effect of ionization chambers used to measure high energy photon beams in radiotherapy. In particular for profile measurements, the air-filled volume leads to an inaccurate measurement of the penumbra.Approach. The AI-based approach presented in this study was trained with synthetic data intended to cover a wide range of realistic linear accelerator data. The synthetic data was created by randomly generating profiles and convolving them with the lateral response function of a Semiflex 3D ionization chamber. The neuronal network was implemented using the open source tensorflow.keras machine learning framework and a U-Net architecture. The approach was validated on three accelerator types (Varian TrueBeam, Elekta VersaHD, Siemens Artiste) at FF and FFF energies between 6 MV and 18 MV at three measurement depths. For each validation, a Semiflex 3D measurement was compared against a microDiamond measurement, and the AI processed Semiflex 3D measurement was compared against the microDiamond measurement.Main results. The AI approach was validated with dataset containing 306 profiles measured with Semiflex 3D ionization chamber and microDiamond. In 90% of the cases, the AI processed Semiflex 3D dataset agrees with the microDiamond dataset within 0.5 mm/2% gamma criterion. 77% of the AI processed Semiflex 3D measurements show a penumbra difference to the microDiamond of less than 0.5 mm, 99% of less than 1 mm.Significance. This AI approach is the first in the field of dosimetry which uses synthetic training data. Thus, the approach is able to cover a wide range of accelerators and the whole specified field size range of the ionization chamber. The application of the AI approach offers an quality improvement and time saving for measurements in the water phantom, in particular for large field sizes.


Assuntos
Inteligência Artificial , Radioterapia (Especialidade) , Aprendizado de Máquina , Imagens de Fantasmas , Fótons/uso terapêutico
6.
Chemistry ; 24(64): 16983-16986, 2018 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-30203873

RESUMO

Hydroboration generally requires the presence of a catalyst to lower the barrier for hydride transfer. This work reports on the first catalyst-free CO2 hydroboration with a neutral boron compound, the nucleophilic diborane [HB(hpp)]2 , 1 (hpp=1,3,4,6,7,8-hexahydro-2H-pyrimido[1,2-a]pyrimidinate). Further hydroboration reactions to bis(boryl)acetals are possible. In acetonitrile, but not in dichloromethane solutions, hydroboration of a first CO2 is followed by hydroboration of a second CO2 molecule. Detailed kinetic measurements for both hydroboration steps were carried out and the influence of the solvent and the addition of a Lewis base on the rate constants analyzed. In contrast to catalyst-free hydroboration of CO2 , hydroboration of the less electrophilic acetone requires the presence of an activating Lewis acid.

7.
Dalton Trans ; 47(6): 2009-2017, 2018 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-29345706

RESUMO

Diborane(4) compounds are versatile reagents in synthetic chemistry. Generally, diboranes(4) with sp2-hybridized boron atoms react as electrophiles. By contrast, the chemistry of nucleophilic diborane(4) compounds with two sp3-hybridized boron atoms is very much underdeveloped. In this work, we systematically vary the substituents of electron-rich diborane(4) compounds with bridging guanidinate substituents. In this way, five new diboranes are synthesized and fully characterized. Using quantum chemical computations, we show that the electronic properties and reactivity of these compounds can be rationally varied by the choice of substituents. The HOMO energies, adiabatic ionization energies and proton affinities are considered as parameters to compare the chemical properties of these unusual compounds.

8.
Phys Med Biol ; 60(3): N59-69, 2015 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-25590354

RESUMO

At particle therapy facilities with pencil beam scanning, the implementation of a ripple filter (RiFi) broadens the Bragg peak, so fewer energy steps from the accelerator are required for a homogeneous dose coverage of the planning target volume (PTV). However, sharply focusing the scanned pencil beams at the RiFi plane by ion optical settings can lead to a Moiré effect, causing fluence inhomogeneities at the isocenter. This has been experimentally proven at the Heidelberg Ionenstrahl-Therapiezentrum (HIT), Universitätsklinikum Heidelberg, Germany. 150 MeV u(-1) carbon-12 ions are used for irradiation with a 3 mm thick RiFi. The beam is focused in front of and as close to the RiFi plane as possible. The pencil beam width is estimated to be 0.78 mm at a 93 mm distance from the RiFi. Radiographic films are used to obtain the fluence profile 30 mm in front of the isocenter, 930 mm from the RiFi. The Monte Carlo (MC) code SHIELD-HIT12A is used to determine the RiFi-induced inhomogeneities in the fluence distribution at the isocenter for a similar setup, pencil beam widths at the RiFi plane ranging from σχ(RiFi to 1.2 mm and for scanning step sizes ranging from 1.5 to 3.7 mm. The beam application and monitoring system (BAMS) used at HIT is modelled and simulated. When the width of the pencil beams at the RiFi plane is much smaller than the scanning step size, the resulting inhomogeneous fluence distribution at the RiFi plane interfers with the inhomogeneous RiFi mass distribution and fluence inhomogeneity can be observed at the isocenter as large as an 8% deviation from the mean fluence. The inverse of the fluence ripple period at the isocenter is found to be the difference between the inverse of the RiFi period and the inverse of the scanning step size. We have been able to use MC simulations to reproduce the spacing of the ripple stripes seen in films irradiated at HIT. Our findings clearly indicate that pencil beams sharply focused near the RiFi plane result in fluence inhomogeneity at the isocenter. In the normal clinical application, such a setting should generally be avoided.


Assuntos
Radioterapia com Íons Pesados/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioisótopos de Carbono/uso terapêutico , Método de Monte Carlo , Dosagem Radioterapêutica , Filme para Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...