Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Eur Heart J Digit Health ; 2(2): 263-270, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34223175

RESUMO

AIMS: To extend the benefits of physiologically guided percutaneous coronary intervention to many more patients, angiography-derived, or 'virtual' fractional flow reserve (vFFR) has been developed, in which FFR is computed, based upon the images, instead of being measured invasively. The effect of operator experience with these methods upon vFFR accuracy remains unknown. We investigated variability in vFFR results based upon operator experience with image-based computational modelling techniques. METHODS AND RESULTS: Virtual fractional flow reserve was computed using a proprietary method (VIRTUheart) from the invasive angiograms of patients with coronary artery disease. Each case was processed by an expert (>100 vFFR cases) and a non-expert (<20 vFFR cases) operator and results were compared. The primary outcome was the variability in vFFR between experts and non-experts and the impact this had upon treatment strategy (PCI vs. conservative management). Two hundred and thirty-one vessels (199 patients) were processed. Mean non-expert and expert vFFRs were similar overall [0.76 (0.13) and 0.77 (0.16)] but there was significant variability between individual results (variability coefficient 12%, intraclass correlation coefficient 0.58), with only moderate agreement (κ = 0.46), and this led to a statistically significant change in management strategy in 27% of cases. Variability was significantly lower, and agreement higher, for expert operators; a change in their recommended management occurred in 10% of repeated expert measurements and 14% of inter-expert measurements. CONCLUSION: Virtual fractional flow reserve results are influenced by operator experience of vFFR processing. This had implications for treatment allocation. These results highlight the importance of training and quality assurance to ensure reliable, repeatable vFFR results.

2.
Heart ; 107(10): 783-789, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33419878

RESUMO

The role of 'stand-alone' coronary angiography (CAG) in the management of patients with chronic coronary syndromes is the subject of debate, with arguments for its replacement with CT angiography on the one hand and its confinement to the interventional cardiac catheter laboratory on the other. Nevertheless, it remains the standard of care in most centres. Recently, computational methods have been developed in which the laws of fluid dynamics can be applied to angiographic images to yield 'virtual' (computed) measures of blood flow, such as fractional flow reserve. Together with the CAG itself, this technology can provide an 'all-in-one' anatomical and functional investigation, which is particularly useful in the case of borderline lesions. It can add to the diagnostic value of CAG by providing increased precision and reduce the need for further non-invasive and functional tests of ischaemia, at minimal cost. In this paper, we place this technology in context, with emphasis on its potential to become established in the diagnostic workup of patients with suspected coronary artery disease, particularly in the non-interventional setting. We discuss the derivation and reliability of angiographically derived fractional flow reserve (CAG-FFR) as well as its limitations and how CAG-FFR could be integrated within existing national guidance. The assessment of coronary physiology may no longer be the preserve of the interventional cardiologist.


Assuntos
Angiografia por Tomografia Computadorizada , Doença das Coronárias/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico , Tomada de Decisão Clínica , Ponte de Artéria Coronária , Doença das Coronárias/cirurgia , Humanos
4.
Genome Med ; 8(1): 71, 2016 06 23.
Artigo em Inglês | MEDLINE | ID: mdl-27338147

RESUMO

Medicine and healthcare are undergoing profound changes. Whole-genome sequencing and high-resolution imaging technologies are key drivers of this rapid and crucial transformation. Technological innovation combined with automation and miniaturization has triggered an explosion in data production that will soon reach exabyte proportions. How are we going to deal with this exponential increase in data production? The potential of "big data" for improving health is enormous but, at the same time, we face a wide range of challenges to overcome urgently. Europe is very proud of its cultural diversity; however, exploitation of the data made available through advances in genomic medicine, imaging, and a wide range of mobile health applications or connected devices is hampered by numerous historical, technical, legal, and political barriers. European health systems and databases are diverse and fragmented. There is a lack of harmonization of data formats, processing, analysis, and data transfer, which leads to incompatibilities and lost opportunities. Legal frameworks for data sharing are evolving. Clinicians, researchers, and citizens need improved methods, tools, and training to generate, analyze, and query data effectively. Addressing these barriers will contribute to creating the European Single Market for health, which will improve health and healthcare for all Europeans.


Assuntos
Pesquisa Biomédica/legislação & jurisprudência , Bases de Dados Factuais/normas , União Europeia/organização & administração , Pesquisa Biomédica/normas , Bases de Dados Factuais/legislação & jurisprudência , Implementação de Plano de Saúde , Humanos , Disseminação de Informação/legislação & jurisprudência
6.
IEEE Trans Med Imaging ; 32(1): 130-8, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23221814

RESUMO

The quality of a computational mesh is an important characteristic for stable and accurate simulations. Quality depends on the regularity of the initial mesh, and in mechanical simulations it evolves in time, with deformations causing changes in volume and distortion of mesh elements. Mesh quality metrics are therefore relevant for both mesh personalization and the monitoring of the simulation process. This work evaluates the significance, in meshes with high order interpolation, of four quality metrics described in the literature, applying them to analyse the stability of the simulation of the heart beat. It also investigates how image registration and mesh warping parameters affect the quality and stability of meshes. Jacobian-based metrics outperformed or matched the results of coarse geometrical metrics of aspect ratio or orthogonality, although they are more expensive computationally. The stability of simulations of a complete heart cycle was best predicted with a specificity of 61%, sensitivity of 85%, and only nominal differences were found changing the intra-element and per-element combination of quality values. A compromise between fitting accuracy and mesh stability and quality was found. Generic geometrical quality metrics have a limited success predicting stability, and an analysis of the simulation problem may be required for an optimal definition of quality.


Assuntos
Coração/anatomia & histologia , Coração/fisiologia , Processamento de Imagem Assistida por Computador/métodos , Modelos Cardiovasculares , Algoritmos , Análise de Variância , Simulação por Computador , Humanos , Imageamento por Ressonância Magnética , Sensibilidade e Especificidade
7.
Med Phys ; 38(5): 2439-49, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21776779

RESUMO

PURPOSE: Morphological descriptors are practical and essential biomarkers for diagnosis and treatment selection for intracranial aneurysm management according to the current guidelines in use. Nevertheless, relatively little work has been dedicated to improve the three-dimensional quantification of aneurysmal morphology, to automate the analysis, and hence to reduce the inherent intra and interobserver variability of manual analysis. In this paper we propose a methodology for the automated isolation and morphological quantification of saccular intracranial aneurysms based on a 3D representation of the vascular anatomy. METHOD: This methodology is based on the analysis of the vasculature skeleton's topology and the subsequent application of concepts from deformable cylinders. These are expanded inside the parent vessel to identify different regions and discriminate the aneurysm sac from the parent vessel wall. The method renders as output the surface representation of the isolated aneurysm sac, which can then be quantified automatically. The proposed method provides the means for identifying the aneurysm neck in a deterministic way. The results obtained by the method were assessed in two ways: they were compared to manual measurements obtained by three independent clinicians as normally done during diagnosis and to automated measurements from manually isolated aneurysms by three independent operators, nonclinicians, experts in vascular image analysis. All the measurements were obtained using in-house tools. The results were qualitatively and quantitatively compared for a set of the saccular intracranial aneurysms (n = 26). RESULTS: Measurements performed on a synthetic phantom showed that the automated measurements obtained from manually isolated aneurysms where the most accurate. The differences between the measurements obtained by the clinicians and the manually isolated sacs were statistically significant (neck width: p <0.001, sac height: p = 0.002). When comparing clinicians' measurements to automatically isolated sacs, only the differences for the neck width were significant (neck width: p <0.001, sac height: p = 0.95). However, the correlation and agreement between the measurements obtained from manually and automatically isolated aneurysms for the neck width: p = 0.43 and sac height: p = 0.95 where found. CONCLUSIONS: The proposed method allows the automated isolation of intracranial aneurysms, eliminating the interobserver variability. In average, the computational cost of the automated method (2 min 36 s) was similar to the time required by a manual operator (measurement by clinicians: 2 min 51 s, manual isolation: 2 min 21 s) but eliminating human interaction. The automated measurements are irrespective of the viewing angle, eliminating any bias or difference between the observer criteria. Finally, the qualitative assessment of the results showed acceptable agreement between manually and automatically isolated aneurysms.


Assuntos
Algoritmos , Angiografia Cerebral/métodos , Imageamento Tridimensional/métodos , Aneurisma Intracraniano/diagnóstico por imagem , Reconhecimento Automatizado de Padrão/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Inteligência Artificial , Humanos , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
Med Image Anal ; 15(6): 801-13, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21788150

RESUMO

In-silico continuum simulations of organ and tissue scale physiology often require a discretisation or mesh of the solution domain. Cubic Hermite meshes provide a smooth representation of anatomy that is well-suited for simulating large deformation mechanics. Models of organ mechanics and deformation have demonstrated significant potential for clinical application. However, the production of a personalised mesh from patient's anatomy using medical images remains a major bottleneck in simulation workflows. To address this issue, we have developed an accurate, fast and automatic method for deriving patient-specific cubic Hermite meshes. The proposed solution customises a predefined template with a fast binary image registration step and a novel cubic Hermite mesh warping constructed using a variational technique. Image registration is used to retrieve the mapping field between the template mesh and the patient images. The variational warping technique then finds a smooth and accurate projection of this field into the basis functions of the mesh. Applying this methodology, cubic Hermite meshes are fitted to the binary description of shape with sub-voxel accuracy and within a few minutes, which is a significant advance over the existing state of the art methods. To demonstrate its clinical utility, a generic cubic Hermite heart biventricular model is personalised to the anatomy of four patients, and the resulting mechanical stability of these customised meshes is successfully demonstrated.


Assuntos
Biologia Computacional/métodos , Simulação por Computador , Coração/fisiologia , Processamento de Imagem Assistida por Computador , Fenômenos Biomecânicos , Análise de Elementos Finitos , Humanos , Imageamento Tridimensional
9.
Ann Biomed Eng ; 39(2): 884-96, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20972626

RESUMO

Modeling of flow in intracranial aneurysms (IAs) requires flow information at the model boundaries. In absence of patient-specific measurements, typical or modeled boundary conditions (BCs) are often used. This study investigates the effects of modeled versus patient-specific BCs on modeled hemodynamics within IAs. Computational fluid dynamics (CFD) models of five IAs were reconstructed from three-dimensional rotational angiography (3DRA). BCs were applied using in turn patient-specific phase-contrast-MR (pc-MR) measurements, a 1D-circulation model, and a physiologically coherent method based on local WSS at inlets. The Navier-Stokes equations were solved using the Ansys®-CFX™ software. Wall shear stress (WSS), oscillatory shear index (OSI), and other hemodynamic indices were computed. Differences in the values obtained with the three methods were analyzed using boxplot diagrams. Qualitative similarities were observed in the flow fields obtained with the three approaches. The quantitative comparison showed smaller discrepancies between pc-MR and 1D-model data, than those observed between pc-MR and WSS-scaled data. Discrepancies were reduced when indices were normalized to mean hemodynamic aneurysmal data. The strong similarities observed for the three BCs models suggest that vessel and aneurysm geometry have the strongest influence on aneurysmal hemodynamics. In absence of patient-specific BCs, a distributed circulation model may represent the best option when CFD is used for large cohort studies.


Assuntos
Artérias Cerebrais/fisiopatologia , Circulação Cerebrovascular , Aneurisma Intracraniano/fisiopatologia , Modelos Cardiovasculares , Adulto , Velocidade do Fluxo Sanguíneo , Simulação por Computador , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...