Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 108
Filtrar
1.
J Gastroenterol ; 59(6): 437-441, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38703187

RESUMO

Fluoroscopy-guided gastrointestinal procedures, including gastrointestinal stenting, balloon-assisted endoscopy (BAE), endoscopic retrograde cholangiopancreatography (ERCP), and endoscopic ultrasound (EUS), are essential for diagnosis and treatment in gastroenterology. Such procedures involve radiation exposure that necessitates strict safety measures to protect patients, doctors, and medical staff. The April 2020 update to Japan's Ionizing Radiation Injury Prevention Regulations for occupational exposure reduced the lens exposure dose limit to approximately one-seventh of its previous level. This change highlights the need for improved safety protocols. Without adaptation, the sustainability of fluoroscopy-based endoscopic techniques could be at risk due to the potential to exceed these new limits. This review examines the current state of medical radiation exposure in the field of gastroenterology in Japan and discusses the findings of the REX-GI study.


Assuntos
Gastroenterologia , Exposição Ocupacional , Exposição à Radiação , Proteção Radiológica , Humanos , Japão , Gastroenterologia/métodos , Gastroenterologia/normas , Exposição Ocupacional/prevenção & controle , Exposição Ocupacional/efeitos adversos , Proteção Radiológica/métodos , Exposição à Radiação/prevenção & controle , Exposição à Radiação/efeitos adversos , Fluoroscopia/efeitos adversos , Fluoroscopia/métodos , Lesões por Radiação/prevenção & controle , Doses de Radiação
2.
Ann Nucl Med ; 38(5): 329-336, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38548987

RESUMO

Recently, an astatine-labeled prostate-specific membrane antigen (PSMA) ligand ([211At]PSMA-5) has been developed for the targeted alpha therapy of patients with prostate cancer. This manual delineates its physicochemical characteristics to assist healthcare professionals in understanding the α-ray-emitting drug of [211At]PSMA-5 when administered to patients. The safety considerations regarding the handling and use of this drug in clinical trials are outlined, based on the proper usage manual of previous studies. The dose limits, as defined by the guidelines of the International Commission on Radiological Protection (ICRP) and the International Atomic Energy Agency (IAEA), are assessed for patients' caregivers and the general public. According to the calculations provided in this manual, clinical trials involving [211At]PSMA-5 can be safely conducted for these populations even if patients are released after its administration. Moreover, this manual provides comprehensive guidance on the handling of [211At]PSMA-5 for healthcare facilities, and compiles a list of precautionary measures to be distributed among patients and their caregivers. While this manual was created by a research team supported by Ministry of Health, Labour, and Welfare in Japan and approved by Japanese Society of Nuclear Medicine, its applicability extends to healthcare providers in other countries. This manual aims to facilitate conducting clinical trials using [211At]PSMA-5 in patients with prostate cancer.


Assuntos
Neoplasias da Próstata , Compostos Radiofarmacêuticos , Masculino , Humanos , Ligantes , Compostos Radiofarmacêuticos/uso terapêutico , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Japão , Antígeno Prostático Específico
3.
Clin Nucl Med ; 49(5): 444-446, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38389211

RESUMO

ABSTRACT: A 69-year-old woman presented with a right clavicle pain. CT revealed a pathological fracture of the right clavicle, multiple osteolytic lesions, and a left cervical mass. 18 F-FDG PET/CT demonstrated a marked FDG uptake in the cervical mass and osteolytic lesions indicative of metastatic parathyroid cancer. 99m Tc-MIBI SPECT/CT revealed either faint or no uptake in the osteolytic lesions. However, a histopathological analysis after a parathyroidectomy and right clavicle biopsy confirmed the diagnosis of parathyroid cancer and the presence of benign brown tumors secondary to hyperparathyroidism. Postoperative imaging showed sclerotic change and a decreased FDG uptake in the bone lesions.


Assuntos
Neoplasias Ósseas , Osteíte Fibrosa Cística , Neoplasias das Paratireoides , Feminino , Humanos , Idoso , Fluordesoxiglucose F18 , Neoplasias das Paratireoides/complicações , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tecnécio Tc 99m Sestamibi , Tomografia Computadorizada de Emissão de Fóton Único , Osteíte Fibrosa Cística/complicações , Neoplasias Ósseas/secundário
4.
Int J Clin Oncol ; 28(12): 1607-1615, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37798414

RESUMO

BACKGROUND: This study aimed to reveal the long-term outcomes and late toxicities (> 5 years) after definitive intensity-modulated radiation therapy (IMRT) in patients with nasopharyngeal carcinoma (NPC). METHODS: Data from 43 patients (median age, 55 years; range, 17-72 years) with NPC who underwent definitive IMRT between 2001 and 2018 were analyzed. All patients were alive and disease-free 5 years after IMRT. A total dose of 70 (range, 66-70) Gy was delivered in 35 (33-35) fractions with concurrent cisplatin chemotherapy. RESULTS: The median follow-up duration was 119 (range, 61.5-242.1) months. Three patients developed locoregional failure at 79, 92, and 149 months after IMRT, respectively. Of these, 2 patients died of disease progression at 136 and 153 months after IMRT. One patient died of aspiration pneumonia 141 months after IMRT, despite salvage of the recurrent tumor by re-irradiation. In addition, one patient died of aspiration pneumonia 62 months after the IMRT. Thus, the 10-year overall survival, progression-free survival, and locoregional control rates were 98%, 92%, and 94%, respectively. Grade ≥ 2 and ≥ 3 late toxicities were observed in 28 (65%) and 9 (21%) patients, respectively. Nine second primary cancers, including five tongue cancers and two external auditory canal carcinomas, were observed in seven (16%) patients. CONCLUSION: Late recurrences, severe late toxicities, and second primary cancers were observed > 5 years after IMRT. A long-term follow-up of > 5 years is needed in patients with NPC.


Assuntos
Neoplasias Nasofaríngeas , Segunda Neoplasia Primária , Pneumonia Aspirativa , Radioterapia de Intensidade Modulada , Humanos , Pessoa de Meia-Idade , Carcinoma Nasofaríngeo/radioterapia , Neoplasias Nasofaríngeas/tratamento farmacológico , Neoplasias Nasofaríngeas/radioterapia , Neoplasias Nasofaríngeas/patologia , Segunda Neoplasia Primária/patologia , Estadiamento de Neoplasias , Recidiva Local de Neoplasia/patologia , Radioterapia de Intensidade Modulada/efeitos adversos , Progressão da Doença , Pneumonia Aspirativa/etiologia , Pneumonia Aspirativa/patologia
5.
Clin Nucl Med ; 48(11): e529-e531, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37793162

RESUMO

ABSTRACT: In recent years, many articles have described the adverse events associated with immune checkpoint inhibitors. We report the case of a 63-year-old woman with bilateral lung shadows after 1-year pembrolizumab immunotherapy following surgery for the right-foot melanoma because of positive sentinel lymph nodes. Follow-up 18 F-FDG PET/CT demonstrated bilateral diffuse mass-like peribronchovascular opacities with marked FDG uptake. Clinically, melanoma metastases with lymphangitic spread were suspected, and bronchoscopy was performed, although no evidence of malignancy was found. The lung shadow was mostly resolved after steroid treatment. Pembrolizumab-induced pneumonitis can be a mimicker of melanoma metastasis with lymphangitic spread.


Assuntos
Carcinoma , Neoplasias Pulmonares , Melanoma , Pneumonia , Feminino , Humanos , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Fluordesoxiglucose F18 , Neoplasias Pulmonares/patologia , Melanoma/tratamento farmacológico
6.
Clin Nucl Med ; 48(12): 1015-1020, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37756474

RESUMO

PURPOSE: The possibility of steroid administration inducing the extensive skeletal muscle uptake (ESMU) of FDG in PET scans was investigated. METHODS: From 8923 consecutive 18 F-FDG PET/CT scans taken at our hospital, 23 scans (15 patients) met adult age and ESMU-positive inclusion criteria. Among the 15 patients, 13 with both ESMU-positive and -negative scans were examined for association with steroid administration. RESULTS: Extensive skeletal muscle uptake was associated with a history of steroid administration ( χ2 test: P = 0.001). Notably, 20 ESMU-positive scans and 11 ESMU-negative scans were significantly different, with 0 to 95 days (median, 18.5 days) and 0 to 708 days (median, 319.0 days) since the last steroid administration, respectively (Mann-Whitney U test, P = 0.003). A significant correlation was observed between mean skeletal muscle SUV max and the number of days since the last steroid administration (Spearman rank correlation coefficient, ρ = -0.501, P = 0.004). Specifically, the degree of ESMU tended to decrease over time, after steroid administration. From multiple regression analysis, the number of days since the last steroid administration was significantly associated with mean SUV max ( P = 0.007), but the blood glucose level was not significant ( P = 0.204), revealing that the number of days since the last steroid administration was an independent risk factor. Multicollinearity was low (the variance inflation factor was 1.007 for both the number of days since the last steroid administration and blood glucose levels). CONCLUSIONS: Steroid administration within months before PET may be one cause of ESMU.


Assuntos
Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Adulto , Humanos , Compostos Radiofarmacêuticos , Glicemia , Tomografia por Emissão de Pósitrons , Músculo Esquelético , Esteroides
7.
Ann Nucl Med ; 37(11): 629-634, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37596439

RESUMO

OBJECTIVE: The purpose of this study is to determine the dose reduction of different shielding materials at various distances from a 177Lu photon radiation source. METHODS: Two protective aprons with lead equivalent thicknesses of 0.25 mm and 0.35 mm and tungsten-containing rubber (TCR) were used as shielding materials. A vial containing 177Lu was sealed in a lead container so that a narrow beam went out through a 3 mm-diameter hole. The dose rate was measured at distances of 0, 10, 50, 100, and 200 cm from the source using a NaI scintillation survey meter to obtain the rate of dose reduction. TCR was tested with thicknesses ranging from 0.3 to 1.0 mm at 0.1 mm intervals and from 1.0 to 4.0 mm at 0.5 mm intervals. RESULTS: At distances of 0, 10, 50, 100, and 200 cm, the dose reduction for the lead equivalent thickness of 0.25 mm were 32.7%, 54.5%, 93.1%, 97.9%, and 99.6%, respectively; and for the lead equivalent thickness of 0.35 mm were 53.4%, 70.6%, 95.6%, 98.9%, and 99.6%, respectively. Without any shielding, the dose rate decreased by 34.4% at 10 cm and by 88.8% at 50 cm from the radiation source. The dose reduction for the TCR thickness of 3.5 mm was 89.8% at 0 cm and 93.3% at 10 cm. The TCR thickness of 0.4 mm provided a dose reduction comparable to or greater than that of the 0.25 mm lead equivalent, whereas the TCR thickness of 1.0 mm or greater provided a dose reduction comparable to that of the 0.35 mm lead equivalent. CONCLUSIONS: Achieving a reduction of 95% or more requires the 0.25 mm lead equivalent for a distance of 100 cm, the 0.35 mm lead equivalent for 50 cm, the TCR thickness of 0.3 mm for 100 cm, or the TCR thickness of 0.9 mm for 50 cm. Without wearing a protective apron, a reduction of approximately 95% is observed at distances greater than 100 cm. These findings would be useful for medical staff engaging in related activities.

8.
J Med Phys ; 48(2): 189-194, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37576099

RESUMO

Aims: We investigated imaging dose and noise under clinical scan conditions at multiple institutions using a simple and unified method, and demonstrated the need for diagnostic reference levels in image-guided radiotherapy (IGRT). Materials and Methods: Nine cone-beam and helical computed tomography (CT) scanners (Varian, Elekta, Accuray Inc., and BrainLAB) from seven institutions were investigated in this study. The weighted cone-beam dose index (CBDIw) was calculated for head and pelvic protocols using a 100 mm pencil chamber under the conditions used in actual clinical practice at each institution. Cone-beam CT image noise was evaluated using polymethylmethacrylate head and body phantoms with diameters of 16 and 32 cm, respectively. Results: For head and pelvic protocols, CBDIw values ranged from 0.94-6.59 and 1.47-20.9 mGy, respectively. Similarly, standard deviation (SD) values ranged from 9.3-34.0 and 26.9-97.4 HU, respectively. The SD values tended to increase with decreasing imaging dose (r = -0.33 and -0.61 for the head and pelvic protocols, respectively). Conclusions: Among the nine machines, the imaging dose for high imaging dose institutions was approximately 20 mGy to the pelvic phantom, and there was a 14-fold difference in dose compared with the other institutions. These results suggest the need to establish DRLs for IGRT to guide clinical decision-making.

9.
Cancers (Basel) ; 15(10)2023 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-37345121

RESUMO

To evaluate the usefulness of change in the automated bone scan index (aBSI) value derived from bone scintigraphy findings as an imaging biomarker for the assessment of treatment response and survival prediction in metastatic castration-resistant prostate cancer (mCRPC) patients treated with Ra-223. This study was a retrospective investigation of a Japanese cohort of 205 mCRPC patients who received Ra-223 in 14 hospitals between July 2016 and August 2020 and for whom bone scintigraphy before and after radium-223 treatment was available. Correlations of aBSI change, with changes in the serum markers alkaline phosphatase (ALP) and prostate-specific antigen (PSA) were evaluated. Additionally, the association of those changes with overall survival (OS) was assessed using the Cox proportional-hazards model and Kaplan-Meier curve results. Of the 205 patients enrolled, 165 (80.5%) completed six cycles of Ra-223. Following treatment, ALP decline (%ALP < 0%) was noted in 72.2% (148/205), aBSI decline (%aBSI < 0%) in 52.7% (108/205), and PSA decline (%PSA < 0%) in 27.8% (57/205). Furthermore, a reduction in both aBSI and ALP was seen in 87 (42.4%), a reduction in only ALP was seen in 61 (29.8%), a reduction in only aBSI was seen in 21 (10.2%), and in both aBSI and ALP increasing/stable (≥0%) was seen in 36 (17.6%) patients. Multiparametric analysis showed changes in PSA [hazard ratio (HR) 4.30, 95% confidence interval (CI) 2.32-8.77, p < 0.0001], aBSI (HR 2.22, 95%CI 1.43-3.59, p = 0.0003), and ALP (HR 2.06, 95%CI 1.35-3.14, p = 0.0008) as significant prognostic factors for OS. For mCRPC patients treated with Ra-223, aBSI change is useful as an imaging biomarker for treatment response assessment and survival prediction.

10.
Sci Rep ; 13(1): 7824, 2023 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-37188704

RESUMO

This study aimed to examine occupational radiation exposure to the lens of the eyes during endoscopic retrograde cholangiopancreatography (ERCP). In this multicenter, prospective, observational cohort study, we collected data regarding occupational radiation exposure to the lens of the eyes during ERCP. We measured radiation exposure of patients and examined its correlation with occupational exposure. In dosimetrically-measured ERCPs (n = 631), the median air kerma at the patient entrance reference point, air kerma-area product, and fluoroscopy time were 49.6 mGy, 13.5 Gycm2, and 10.9 min, respectively. The median estimated annual radiation dose to the lens of the eyes was 3.7, 2.2, and 2.4 mSv for operators, assistants, and nurses, respectively. Glass badge over lead aprons and eye dosimeter results were similar in operators but differed in assistants and nurses. A strong correlation was shown between eye dosimeter measurements and patients' radiation exposure. The shielding rates of the lead glasses were 44.6%, 66.3%, and 51.7% for operators, assistants, and nurses, respectively. This study revealed the actual occupational exposure dose for the lens of the eyes during ERCP and the efficacy of lead glass. Values of radiation exposure to patients can help estimate exposure to the lens of the eyes of medical staff.


Assuntos
Cristalino , Exposição Ocupacional , Traumatismos Ocupacionais , Exposição à Radiação , Lesões por Radiação , Humanos , Colangiopancreatografia Retrógrada Endoscópica/efeitos adversos , Colangiopancreatografia Retrógrada Endoscópica/métodos , Estudos Prospectivos , Lesões por Radiação/etiologia , Lesões por Radiação/prevenção & controle , Exposição Ocupacional/efeitos adversos , Exposição à Radiação/efeitos adversos , Doses de Radiação , Fluoroscopia
11.
DEN Open ; 3(1): e227, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37064420

RESUMO

Objectives: We surveyed and reported low protective equipment usage and insufficient knowledge among endoscopy-fluoroscopy departments in Japan in 2020. Two years later, we conducted a follow-up survey of doctors, nurses, and technologists in Japan. Methods: We conducted a questionnaire survey on radiation protection from May to June 2022. The participants were medical staff, including doctors, nurses, and radiological and endoscopy technicians in endoscopy-fluoroscopy departments. The questionnaire included 17 multiple-choice questions divided into three parts: background, equipment, and knowledge. Results: We surveyed 464 subjects from 34 institutions. There were 267 doctors (58%), 153 nurses (33%), and 44 technologists (9%). The rate of wearing a lead apron was 98% in this study. The rates of wearing a thyroid collar, lead glasses, and radiation dosimeter were 27%, 35%, and 74%, respectively. The trend of the protective equipment rate was similar to that of our previous study; however, radiation dosimetry among doctors was still low at 58%. The percentage of subjects who knew the radiation exposure (REX) dose of each procedure was low at 18%. Seventy-six percent of the subjects attended lectures on radiation protection, and 73% knew about the three principles of radiation protection; however, the concept of diagnostic reference levels was not well known (18%). Approximately 60% of the subjects knew about the exposure dose increasing cancer mortality (63%) and the 5-year lens REX limit (56%). Conclusions: There was some improvement in radiation protection equipment or education, but relatively little compared to the 2020 survey of endoscopy departments.

12.
Med Dosim ; 48(3): 193-196, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37080819

RESUMO

We performed daily cone-beam computed tomography (CBCT) to determine the impact of rectal gas on the movements of prostate and seminal vesicles (SVs). We aimed to determine the relationship between planning target volume (PTV) margins and rectal gas. In 30 treatments of 15 prostate cancer patients, excessive rectal gas was removed and CBCT images were analyzed. Image registration between planning CT and daily CBCT images before and after rectal gas removal was performed for pelvic bone and prostate matching. The couch movement distance between each matching was considered the prostate movement. In addition, we measured SV tip movement between each matching. The anterior-posterior movement of the prostate before rectal gas removal (3.1 ± 2.9 mm) was significantly greater than that after rectal gas removal (1.2 ± 1.2 mm; p < 0.01). The left-right and superior-inferior movements were similar regardless of the presence or absence of rectal gas. The SV movement distances before and after rectal gas removal were 11.0 ± 5.8 mm and 4.6 ± 3.8 mm, respectively (p < 0.01), in pelvic bone matching, and 8.0 ± 4.2 mm and 3.8 ± 3.2 mm, respectively (p < 0.01), in prostate matching. After rectal gas removal, the SV position did not differ significantly between each matching. In 26 of the 30 treatments, SV movement distance in the presence of rectal gas was >6 mm, which is the minimum PTV margin at our institution. In comparison, after rectal gas removal and prostate matching, only 6 treatments demonstrated an SV movement distance of >6 mm. In the presence of rectal gas, the SVs require greater PTV margins than the prostate. Rectal gas removal should be considered if the movement distance on prostate matching is greater than the minimum PTV margin at treating institution.

13.
Br J Radiol ; 96(1146): 20230086, 2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-37086068

RESUMO

OBJECTIVE: We aimed to examine the factors contributing to radiation exposure exceeding the DRL of the transnasal ileus tube placement in this post hoc analysis from the cohort of the REX-GI study. METHODS: Patients with transnasal ileus tubes were enrolled in the rex-gi study from may 2019 to december 2020. We investigated the endoscope insertion time (min), procedure time (min), tube insertion length (cm), fluoroscopy time (FT: min), air kerma at the patient entrance reference point (Ka.r: mGy), and air kerma-area product (PKA: Gycm2). The third quartile value of the PKA value was calculated as the diagnostic reference level (DRL) value. We explored the factors associated with radiation exposure exceeding the DRL. RESULTS: In the REX-GI study, 496 patients who underwent transnasal ileus tube placement were enrolled. The median age of the patients was 71 years. The median endoscopy insertion time, procedure time, and tube insertion length were 6 min, 20 min, and 170 cm, respectively. The third quartile/median FT, Ka.r, and PKA were 18/11.9 min, 99.2/54.4 mGy, and 46.9/28 Gycm2, respectively. The third quartile value of PKA (47 Gycm2) was set as the DRL value. There were differences in distribution by the hospital. Compared with procedures under the DRL, the FT (19 vs 10 min), procedure time (25 vs 18 min), and tube insertion length (185 vs 165 cm) were significantly longer for procedures above the DRL. CONCLUSION: We report the DRL for transnasal ileus tube placement in Japan. A longer procedure time and tube insertion length may be associated with DRL exceedance. ADVANCES IN KNOWLEDGE: Transnasal ileus tube placement under fluoroscopy guidance is a standard clinical procedure for bowel obstruction. However, the appropriate radiation dose level has not yet been established.We report the (DRL) for transnasal ileus tube placement in Japan. A longer procedure time and tube insertion length may be associated with DRL exceedance.


Assuntos
Íleus , Obstrução Intestinal , Humanos , Idoso , Níveis de Referência de Diagnóstico , Endoscopia , Fluoroscopia , Doses de Radiação , Íleus/diagnóstico por imagem
14.
Radiother Oncol ; 180: 109491, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36706956

RESUMO

BACKGROUND AND PURPOSE: In this study, fluoromisonidazole positron emission tomography (F-MISO PET/CT) was used to evaluate tumor hypoxia and re-oxygenation in patients with lung tumors treated with stereotactic body radiation therapy (SBRT). MATERIALS AND METHODS: Patients with T1-2 N0 lung cancer were included in this study. The prescribed dose was 48-52 Gy in four fractions. F-MISO PET/CT was performed twice, before SBRT and 1-3 days after the first irradiation. The maximum standardized uptake value (SUVmax) and tumor/muscle ratio (TMR) were evaluated as indicators of hypoxia. The threshold for hypoxia was defined as a TMR of 1.30 or more. RESULTS: Between 2016 and 2021, 15 patients were included. Pre-treatment tumor hypoxia was observed in nine tumors (60 %). TMR in all six tumors without pre-treatment hypoxia rose after single high-dose irradiation. In contrast, TMR in six of nine tumors with pre-treatment hypoxia dropped after irradiation, suggesting re-oxygenation. Although no local recurrence was noted, regional and/or distant relapses were seen in four patients (27 %). Of these, three had tumors with abnormal F-MISO uptake. The remaining patient had a tumor without signs of hypoxia on pre-treatment PET/CT. The 2-year progression free survival of patients with tumors with and without pre-treatment hypoxia were 30 % and 63 %, respectively (p = 0.319). CONCLUSION: Tumor hypoxia reduced after single high-dose irradiation. Tumor with F-MISO uptake seems to be an unfavorable prognostic factor in lung SBRT.


Assuntos
Neoplasias Pulmonares , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Radiocirurgia , Hipóxia Tumoral , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/radioterapia , Pulmão/patologia , Doses de Radiação , Hipóxia Tumoral/efeitos da radiação , Tomografia por Emissão de Pósitrons , Radiossensibilizantes , Estudos Prospectivos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais
15.
Eur J Nucl Med Mol Imaging ; 50(5): 1487-1498, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36539508

RESUMO

PURPOSE: To develop a novel nomogram for determining radium-223 dichloride (Ra-223) treatment suitability for metastatic castration-resistant prostate cancer (mCRPC) patients. METHODS: This Japanese Ra-223 Therapy in Prostate Cancer using Bone Scan Index (J-RAP-BSI) Trial was a retrospective multicenter investigation enrolled 258 mCRPC patients in Japan with Ra-223 treatment between June 2016 and August 2020, with bone scintigraphy findings before treatment, clinical data, and survival outcome available. A nomogram was constructed using prognostic factors for overall survival (OS) based on a least absolute shrinkage and selection operator Cox regression model. A sub-analysis was also conducted for patients meeting European Medicines Agency (EMA) guidelines. RESULTS: Within a median of 17.4 months after initial Ra-223 treatment, 124 patients (48.1%) died from prostate cancer. Predictive factors included (1) sum of prior treatment history (score 0, never prior novel androgen receptor-targeted agents (ARTA) therapy, never prior taxane-based chemotherapy, and ever prior bisphosphonate/denosumab treatment), (2) Eastern Cooperative Oncology Group (ECOG) performance status, (3) prostate-specific antigen doubling time (PSADT), (4) hemoglobin, (5) lactate dehydrogenase (LDH), and (6) alkaline phosphatase (ALP) levels, and (7) automated bone scan index (aBSI) value based on bone scintigraphy. The nomogram using those factors showed good discrimination, with apparent and optimism-corrected Harrell's concordance index values of 0.748 and 0.734, respectively. Time-dependent area under the curve values at 1, 2, and 3 years were 0.771, 0.818, and 0.771, respectively. In 227 patients meeting EMA recommendation, the nomogram with seven factors showed good discrimination, with apparent and optimism-corrected Harrell's concordance index values of 0.722 and 0.704, respectively. Time-dependent area under the curve values at 1, 2, and 3 years were 0.747, 0.790, and 0.759, respectively. CONCLUSION: This novel nomogram including aBSI to select mCRPC patients to receive Ra-223 with significantly prolonged OS possibility was found suitable for assisting therapeutic decision-making, regardless of EMA recommendation.


Assuntos
Neoplasias Ósseas , Neoplasias de Próstata Resistentes à Castração , Rádio (Elemento) , Masculino , Humanos , Rádio (Elemento)/uso terapêutico , Neoplasias de Próstata Resistentes à Castração/diagnóstico por imagem , Neoplasias de Próstata Resistentes à Castração/radioterapia , Neoplasias de Próstata Resistentes à Castração/tratamento farmacológico , Nomogramas , Prognóstico , População do Leste Asiático , Neoplasias Ósseas/diagnóstico por imagem , Neoplasias Ósseas/radioterapia , Neoplasias Ósseas/tratamento farmacológico , Estudos Retrospectivos
16.
Strahlenther Onkol ; 199(5): 465-476, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36477250

RESUMO

PURPOSE: Stereotactic body radiotherapy (SBRT) is a treatment option for early-stage lung cancer. We aimed to examine the differences in failure patterns after SBRT according to the clinical T stage. METHODS: A total of 120 patients with early-stage lung cancer (T1-3N0M0) who underwent SBRT were analysed. The clinical stage in patients whose tumours were in contact with the chest wall was confirmed using four-dimensional computed tomography (4D-CT). Local failure, regional node metastasis, and distant metastasis were confirmed from clinical charts. RESULTS: Median follow-up time was 27.5 months (range 7-122) after SBRT. Thirteen patients were restaged from clinical T2 with visceral pleural invasion to T3 with chest wall invasion using 4D-CT analysis. Thirty-seven patients developed recurrences. The median progression-free survival (PFS) and overall survival (OS) were 38.1 and 53.8 months, respectively. The 3­year PFS and OS rates were 50.7% and 60.3%, respectively. A significant difference was observed in PFS according to the clinical T stage (p = 0.001). No significant differences were observed in OS according to the clinical T stage (p = 0.213). The proportion of locoregional failures relative to distant metastasis decreased with progression from T1 to T3. The pleural dissemination rate was significantly higher in T3 tumours than in T1 and T2 tumours (p = 0.010). CONCLUSION: Clinical T stage is associated with PFS after SBRT for lung cancer. There were differences in the failure patterns according to T stage. 4D-CT might provide significant information for assessing chest wall invasion associated with unfavourable PFS.


Assuntos
Neoplasias Pulmonares , Radiocirurgia , Humanos , Tomografia Computadorizada Quadridimensional , Radiocirurgia/métodos , Resultado do Tratamento , Estudos Retrospectivos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia
17.
JGH Open ; 7(12): 869-874, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38162840

RESUMO

Background and Aim: Recently, the use of various endoscopic procedures performed under X-ray fluoroscopy guidance has increased. With the popularization of such procedures, diagnostic reference levels (DRLs) have been widely accepted as the global standard for various procedures with ionizing radiation. The Radiation Exposure from Gastrointestinal Fluoroscopic Procedures (REX-GI) study aimed to prospectively collect actual radiation exposure (RE) data and establish DRLs in gastrointestinal endoscopy units. In this post hoc analysis of the REX-GI study, we established DRLs for each disease site by analyzing cases of gastrointestinal enteral metallic stent placement. Methods: The REX-GI study was a multicenter, prospective observational study conducted to collect actual RE data during gastrointestinal enteral metallic stent placement. To establish DRL values for three disease sites, namely the esophagus, gastroduodenum, and colon, we examined fluoroscopy time (FT; min), number of X-ray images, air kerma at the patient entrance reference point (K a,r; mGy), and the air kerma-area product (P KA; Gy cm2) during enteral metallic stent placement. Results: Five-hundred and twenty-three stenting procedures were performed. The DRL values of FT (min) and the number of X-ray images for the esophagus/gastroduodenum/colon were 9/16/18 min and 9/15/11 min, respectively. Furthermore, the DRL values of K a,r and P KA for each disease site were 43.3/120/124 mGy and 10.3/36.6/48.4 Gy cm2, respectively. Among the procedures, esophageal stents were significantly associated with the lowest values (P < 0.001). Conclusion: The characteristics of RE vary according to disease site among gastrointestinal enteral metallic stent placements. Thus, it is desirable to set DRL values based on the disease site.

18.
Anticancer Res ; 42(11): 5305-5314, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36288870

RESUMO

BACKGROUND/AIM: This study evaluated the impact of knowledge-based plan (KBP) model improvement on plan complexity and delivery accuracy in volumetric modulated arc therapy (VMAT) for prostate cancer at multiple institutions. MATERIALS AND METHODS: Five institutions created the first KBP model before April 2017 and subsequently devised a new model (second model) based on feedback from the first KBP and the efforts of planners after April 2019. The dose-volume histogram (DVH) parameters were validated for two prostate cancer cases between the first and second KBPs. Plan complexity metrics, of the modulation complexity score for VMAT (MCSv), closed leaf score (CLS), small aperture score (SAS), and leaf travel (LT), were compared. The delivery accuracy metrics of γ pass rate and point dose discrepancy (plan vs. measurement) at isocenter were also compared. RESULTS: There were no significant differences in DVH parameters between the KBPs. Conversely, V50% of the rectum and bladder was reduced in 6/10 and 8/10 patients, respectively, and these variations were also converged from the first KBP to the second KBP. The mean±1SDs of MCSv, CLS, SAS20mm, and LT (first KBP vs. second KBP) were 0.27±0.033 vs. 0.26±0.044, 0.062±0.032 vs. 0.14±0.091, 0.59±0.048 vs. 0.70±0.14, and 411.91±32.08 mm vs. 548.33±127.50 mm, respectively. The delivery accuracy did not differ, whereas MCSv was moderately correlated with the point dose discrepancy. CONCLUSION: Multi-leaf collimator motion could be more complex with KBP model improvement, which had the potential to deteriorate the delivery accuracy.


Assuntos
Neoplasias da Próstata , Radioterapia de Intensidade Modulada , Masculino , Humanos , Planejamento da Radioterapia Assistida por Computador , Dosagem Radioterapêutica , Neoplasias da Próstata/radioterapia , Raios gama
19.
Kaku Igaku ; 59(1): 51-55, 2022.
Artigo em Japonês | MEDLINE | ID: mdl-36104246

RESUMO

OBJECTIVE: [177Lu]Lu-PSMA-617 is a radioisotope used in nuclear medicine. It is necessary to take appropriate measures to limit its exposure and ensures its airborne concentrations do not exceed legally permitted levels. Therefore, the purpose of this study was to measure the airborne radioactivity concentration in the inpatient room after administering [177Lu]Lu-PSMA-617 to humans. METHODS: Three males with advanced prostate-specific membrane antigen (PSMA)-positive metastatic castration resistant prostate cancer were intravenously administered [177Lu]Lu-PSMA-617 (7.4 GBq ± 10%) in an inpatient room, and the airborne radioactivity concentrations were measured at two locations in the room (in the center of the room and at the bedside) using a filter collection method. RESULTS: After administration of [177Lu]Lu-PSMA-617, the airborne radioactivity concentrations measured were below the limit of detection (1.1 × 10-6 Bq/cm3 or 9.5 × 10-7 Bq/cm3) in all three humans, and all concentrations were consistently below the standard value of 1/10,000 of 2 × 10-2 Bq/cm3, the legal airborne concentration limit of 177Lu. CONCLUSION: The results of this study confirmed that the airborne concentration of [177Lu]Lu-PSMA-617 after administration to humans was below the legally permitted level.


Assuntos
Neoplasias de Próstata Resistentes à Castração , Radioatividade , Dipeptídeos , Compostos Heterocíclicos com 1 Anel , Humanos , Pacientes Internados , Lutécio , Masculino , Antígeno Prostático Específico , Neoplasias de Próstata Resistentes à Castração/patologia , Neoplasias de Próstata Resistentes à Castração/radioterapia
20.
Gan To Kagaku Ryoho ; 49(8): 809-812, 2022 Aug.
Artigo em Japonês | MEDLINE | ID: mdl-36046961

RESUMO

Radiotheranostics is characterized by labeling high quality tumor-seeking compounds with imaging radionuclides for imaging and labeling with therapeutic radionuclides for therapeutic use. Although the nuclear medicine approach of fusing imaging and therapy is no doubt effective, the point is to recognize that it is not always necessary to carry out both imaging and therapy in a series, and how it is effective to carry out imaging and therapy respectively is the point. It may depend largely on the disease that is dealt with. In the therapy, it is of great concern to make optimum use of α emitters in addition to the conventional ß emitters. In the future, theranostics technology and its application to personalized medicine will bring great benefits.


Assuntos
Neoplasias , Radioisótopos , Humanos , Neoplasias/diagnóstico por imagem , Neoplasias/radioterapia , Medicina de Precisão , Radioisótopos/uso terapêutico , Compostos Radiofarmacêuticos/uso terapêutico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...