Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Mikrochim Acta ; 190(8): 321, 2023 07 25.
Artigo em Inglês | MEDLINE | ID: mdl-37491620

RESUMO

Neglected tropical diseases are those caused by infectious agents or parasites and are considered endemic in low-income populations. These diseases also have unacceptable indicators and low investment in research, drug production, and control. Tropical diseases such as leishmaniasis are some of the main causes of morbidity and mortality around the globe. Electrochemical immunosensors are promising tools for diagnostics against these diseases. One such benefit is the possibility of assisting diagnosis in isolated regions, where laboratory infrastructure is lacking. In this work, different peptides were investigated to detect antibodies against Leishmania in human and canine serum samples. The peptides evaluated (395-KKG and 395-G) have the same recognition site but differ on their solid-binding domains, which ensure affinity to spontaneously bind to either graphene oxide (GO) or graphene quantum dots (GQD). Cyclic voltammetry and differential pulse voltammetry were employed to investigate the electrochemical behavior of each assembly step and the role of each solid-binding domain coupled to its anchoring material. The graphene affinity peptide (395-G) showed better reproducibility and selectivity when coupled to GQD. Under the optimized set of experimental conditions, negative and positive human serum samples responses were distinguished based on a cut-off value of 82.5% at a 95% confidence level. The immunosensor showed selective behavior to antibodies against Mycobacterium leprae and Mycobacterium tuberculosis, which are similar antibodies and potentially sources of false positive tests. Therefore, the use of the graphene affinity peptide as a recognition site achieved outstanding performance for the detection of Leishmania antibodies.


Assuntos
Técnicas Biossensoriais , Grafite , Leishmaniose , Animais , Cães , Humanos , Carbono/química , Grafite/química , Reprodutibilidade dos Testes , Imunoensaio , Peptídeos , Anticorpos , Leishmaniose/diagnóstico
2.
One Health ; 17: 100581, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37332885

RESUMO

The recent geographic spread of Leishmania infantum along the borders of Argentina, Brazil and Paraguay has been highlighted. In our previous study, Lutzomyia longipalpis was found in 55 of 123 patches surveyed, and in some patches, sandflies were found at higher densities, forming hotspots. Based on the One Health approach, we investigated the seasonality of the vector, the presence of parasite DNA, and the environmental factors that contribute to vector and parasite dispersal in these previously described hotspots in Foz do Iguaçu, Brazil. Entomological surveys were conducted monthly for one year. Fourteen hotspots peridomicile and six intradomicile were sampled. PCR was used to assess the prevalence of Leishmania DNA in sandflies. Zero-inflated negative binomial regression was used to determine the association of micro- and mesoscale environmental variables with the occurrence and abundance of the three most abundant sandfly species sampled. A total of 3543 species were captured, with Lutzomyia longipalpis being the predominant species (71.78%) of the 13 species found. Evandromyia edwardsi, Expapillata firmatoi, Micropygomyia ferreirana and Pintomyia christenseni were reported for the first time in the region. NDVI, distance to water, precipitation, west-to-east wind, wind speed, maximum and minimum relative humidity, and sex were significant variables associated with vector presence/abundance in the environment. Vector presence/abundance in the peridomicile was associated with precipitation, altitude, maximum temperature, minimum and maximum relative humidity, west-to-east wind, wind speed, and sex. Leishmania DNA was detected in an average of 21% of Lu. longipalpis throughout the year. Vector abundance is concentrated in urban and peri-urban areas, with some specimens present in different parts of the city and some sites with high vector abundance. This distribution suggests that the risk of actual contact between humans and parasite vectors in urban areas during the epidemic period is associated with patches of peri-urban vegetation and then extends into urban areas.

3.
Talanta ; 257: 124348, 2023 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-36801564

RESUMO

Electrochemical immunosensors are excellent alternatives to prepare portable platforms used for rapid and inexpensive diagnostic of infectious diseases such as the recently emerged COVID-19. Incorporating synthetic peptides as selective recognition layers combined with nanomaterials such as gold nanoparticles (AuNPs) can significantly enhance the analytical performance of immunosensors. In the present study, an electrochemical immunosensor based on solid-binding peptide was built and evaluated towards SARS-CoV-2 Anti-S antibodies detection. The peptide used as recognition site has two important portions: one based on the viral receptor binding domain (RBD), capable of recognizing antibodies of the spike protein (Anti-S), and another suitable for interacting with gold nanoparticles. Gold-binding peptide (Pept/AuNP) dispersion was used directly to modify a screen-printed carbon electrode (SPE). The voltammetric behavior of the [Fe(CN)6]3-/4- probe after every construction and detection step was recorded using cyclic voltammetry by assessing the stability of the Pept/AuNP as a recognition layer onto the electrode surface. Differential pulse voltammetry was used as a detection technique, and a linear working range from 75 ng mL-1 to 15 µg mL-1 was established, with 1.059 µA dec-1 of sensitivity and R2 = 0.984. The response selectivity against SARS-CoV-2 Anti-S antibodies was investigated in presence of concomitant species. The immunosensor was used to detect SARS-CoV-2 Anti-spike protein (Anti-S) antibodies in human serum samples, successfully differentiating between negative and positive responses of samples at a 95% confidence level. Therefore, the gold-binding peptide is a promising tool to be applied as a selective layer for antibody detection.


Assuntos
Técnicas Biossensoriais , COVID-19 , Nanopartículas Metálicas , Humanos , Ouro/química , SARS-CoV-2 , Técnicas Biossensoriais/métodos , Nanopartículas Metálicas/química , Imunoensaio/métodos , Anticorpos Antivirais , Peptídeos , Técnicas Eletroquímicas/métodos
4.
Biosensors (Basel) ; 12(10)2022 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-36291021

RESUMO

The development of immunosensors to detect antibodies or antigens has stood out in the face of traditional methods for diagnosing emerging diseases such as the one caused by the SARS-CoV-2 virus. The present study reports the construction of a simplified electrochemical immunosensor using a graphene-binding peptide applied as a recognition site to detect SARS-CoV-2 antibodies. A screen-printed electrode was used for sensor preparation by adding a solution of peptide and reduced graphene oxide (rGO). The peptide-rGO suspension was characterized by scanning electron microscopy (SEM), Raman spectroscopy, and Fourier transform infrared spectroscopy (FT-IR). The electrochemical characterization (electrochemical impedance spectroscopy-EIS, cyclic voltammetry-CV and differential pulse voltammetry-DPV) was performed on the modified electrode. The immunosensor response is based on the decrease in the faradaic signal of an electrochemical probe resulting from immunocomplex formation. Using the best set of experimental conditions, the analytic curve obtained showed a good linear regression (r2 = 0.913) and a limit of detection (LOD) of 0.77 µg mL-1 for antibody detection. The CV and EIS results proved the efficiency of device assembly. The high selectivity of the platform, which can be attributed to the peptide, was demonstrated by the decrease in the current percentage for samples with antibody against the SARS-CoV-2 S protein and the increase in the other antibodies tested. Additionally, the DPV measurements showed a clearly distinguishable response in assays against human serum samples, with sera with a response above 95% being considered negative, whereas responses below this value were considered positive. The diagnostic platform developed with specific peptides is promising and has the potential for application in the diagnosis of other infections that lead to high antibody titers.


Assuntos
Técnicas Biossensoriais , COVID-19 , Grafite , Humanos , Grafite/química , Técnicas Biossensoriais/métodos , Técnicas Eletroquímicas/métodos , SARS-CoV-2 , Espectroscopia de Infravermelho com Transformada de Fourier , Imunoensaio , COVID-19/diagnóstico , Eletrodos , Limite de Detecção , Peptídeos
5.
J Immunol Methods ; 503: 113242, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35182576

RESUMO

Immunoassays are practical and cost-effective approaches suitable for large-scale tuberculosis (TB) screening. This study identified new peptide mimotopes of Mycobacterium tuberculosis and applied them in the serodiagnosis of TB. Thereby, linear (X15, X8CX8) and constrained (LX-4 and LX-8) phage display peptide libraries were screened with purified Immunoglobulin G antibodies from TB-positive patients, and eight mimotopes were selected. The mimotope peptides were screened using the SPOT-synthesis technique followed by immunoblotting. Peptides P.Mt.PD.4 and P.Mt.PD.7 demonstrated the highest binding affinity and were chemically synthesized and used as antigens for enzyme-linked immunosorbent assay (ELISA) assays. Experimental designs were used to optimize the assays and to assess each variable's influence. Peptide P.Mt.PD.7 was differentiated between positive and negative samples and achieved 100% sensitivity and specificity when tested on a 100-sera panel. Therefore, the selected peptide was applied to the ELISA assay as a screening method for diagnosing TB represents a potential tool for helping to combat the disease.


Assuntos
Bacteriófagos , Mycobacterium tuberculosis , Tuberculose , Ensaio de Imunoadsorção Enzimática/métodos , Humanos , Biblioteca de Peptídeos , Peptídeos , Projetos de Pesquisa , Tuberculose/diagnóstico
6.
Braz. arch. biol. technol ; 64(spe): e21210127, 2021. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1285571

RESUMO

Abstract The rapid and accurate diagnosis of tuberculosis (TB), especially considering limited resources, is still a challenge. Development of new methodologies and tests are needed to overcome several disadvantages of the available standard tests. We evaluated the diagnostic potential of two antigens specific for Mycobacterium tuberculosis, the CFP10 and ESAT6 recombinant proteins, and developed stable formulations thereof. Sensitivity and specificity of the delayed-type hypersensitivity (DTH) skin testing and the induction of gamma interferon production (IFN-γ) by lymphocytes, as a non-invasive test, were evaluated using the CFP10 and ESAT6 protein formulations. The recombinant proteins produced by our group presented a high DTH response and the ability to differentiate between tuberculosis infection, BCG vaccination, and the contact with non-tuberculous mycobacteria (NTM). The production of IFN-γ by stimulation with individual and combined proteins was detected in a panel of 40 individuals and showed a specificity of 100% and a sensitivity of 90% when the two proteins were used together. Lyophilized formulations were stable under all conditions, while soluble formulations were stable under freezing at -20 ºC and -80 ºC. The proposed formulations containing the ESAT6 and CFP10 recombinant antigens constitute satisfactory tools for TB testing, suitable to be developed and implemented in a large-scale trial.


Assuntos
Tuberculose/diagnóstico , Interferon gama , Mycobacterium tuberculosis/isolamento & purificação , Antígenos/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA