Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 81(4): 043504, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20441338

RESUMO

By using a water transmission line, current wave shaping was demonstrated for a fast capillary Z-pinch discharge recombination soft x-ray laser study. The pulsed power system consists of a water capacitor, a gap switch, a transmission line, and a capillary plasma load. A voltage wave initiated at the water capacitor propagates toward the capillary load through the transmission line. Control of the pulse delay that occurred in the transmission line provides the superposition of the forward and the backward voltage waves effectively in order to perform current wave shaping with higher current amplitude and rapid current decay.

2.
Opt Lett ; 34(19): 2964-6, 2009 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-19794783

RESUMO

Femtosecond laser pulses were used to make plasma filaments near an isolated positively or negatively highly biased electrode. The electrode was well positioned to sustain a high voltage up to U(max)=+/-400 kV to avoid the induced breakdown or a glow discharge; the shape of the electrode was chosen to reduce the corona effects at the maximal voltage. The filament's UV emission is shown to be very sensitive to the voltage applied: it increases nonlinearly with the electrode potential. Along with nanosecond filament-induced flashes at both polarities, long, about a half microsecond, corona flashes were observed at the negative polarity.

3.
J Food Sci ; 72(7): M280-5, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17995653

RESUMO

A novel and compact low-energy (keV) high-power pulsed electron beam (e-beam) that utilizes a secondary emission electron gun (SEEG) was designed and constructed. Escherichia coli JM 109 at a concentration of 10(6) CFU/mL was spread-plated on Luria-Bertani (LB) medium and subjected to the SEEG e-beam. The e-beam was administered as 1 or 5 pulses. The duration of a single pulse was constant at 5 micros, e-beam current density was constant at 25 mA/cm2, and e-beam energy varied between 60 and 82.5 keV. Following treatment with the SEEG e-beam, survivors of the irradiated E. coli samples were enumerated by a standard 10-fold dilution and spread-plated. The survivor curves were plotted on logarithmic scale as a function of e-beam dose. The D10-values were calculated as a negative reciprocal of the slope of the survivor curves. The D10-values for E. coli inactivated with 1- and 5-pulse SEEG e-beam were 0.0026 and 0.0217 Gy, respectively. These D10-values were considerably lower than published D10-values for E. coli inactivated with conventional high-energy continuous e-beam, likely due to shorter exposure time (t), greater current density (J), and a pulse mode of the SEEG e-beam. The SEEG e-beam showed promising results for microbial inactivation in a nonthermal manner; however, due to low energy of the SEEG e-beam, current applications are limited to surface decontamination. The SEEG e-beam may be an efficient processing step for surface inactivation of food-borne pathogens on ready-to-eat products, including fresh and leafy vegetables.


Assuntos
Escherichia coli/efeitos da radiação , Contaminação de Alimentos/prevenção & controle , Irradiação de Alimentos , Conservação de Alimentos/métodos , Contagem de Colônia Microbiana , Qualidade de Produtos para o Consumidor , Relação Dose-Resposta à Radiação , Escherichia coli/crescimento & desenvolvimento , Microbiologia de Alimentos , Cinética , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...