Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 68
Filtrar
1.
Heart Rhythm ; 2024 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-38797310

RESUMO

BACKGROUND: Peridevice leak (PDL) following left atrial appendage closure (LAAC) portends adverse outcomes. OBJECTIVE: To assess the incidence, predictors, clinical implications, and temporal evolution of PDL following LAAC. METHODS: This single-center retrospective study included all patients who underwent LAAC with Watchman FLX and had no PDL detected at implant. The primary endpoint was incidence of new PDL at initial imaging. The composite secondary endpoint included continued oral anticoagulation after initial imaging, device-related thrombus, stroke or transient ischemic attack, major bleeding, and need for PDL closure at longest follow-up. Temporal evolution of PDL was assessed in patients with available surveillance imaging. RESULTS: Among 355 patients who completed imaging at 47 (IQR 6) days, 139 (39%) had a new PDL with a mean leak size of 3.2±1.4 [median 3.0 (IQR 2.0), and range 1.0-9.0 mm]. Multiple deployment attempts and larger device size were positive predictors of PDL, while increased contrast volume administration was a negative predictor of PDL. The composite secondary endpoint occurred in 42 (30%) and 33 (15%) patients with and without PDL respectively (p<0.001). Among the 139 patients with PDL, 43 (31%) had surveillance imaging where leak size regressed from 3.7±1.8mm at 46 (IQR 7) days to 1.7±2.0mm at 189 (IQR 127) days (p<0.001). The leak size regressed in 33 (77%), remained stable in 4 (9%), and progressed in 6 (14%) cases. CONCLUSION: Despite design improvements, LAAC with Watchman FLX demonstrates significant incidence of PDL with meaningful clinical implications. Regardless of initial size, most leaks regressed over time.

3.
JACC Clin Electrophysiol ; 10(1): 68-78, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37897465

RESUMO

BACKGROUND: Injury to the esophagus has been reported in a high percentage of patients undergoing ablation of atrial fibrillation (AF). OBJECTIVES: This study assessed the incidence of esophageal injury in patients undergoing ablation of AF with and without an esophageal deviating device. METHODS: This prospective, randomized, multicenter, double-blinded, controlled Food and Drug Administration investigational device exemption trial compared the incidence of ablation-related esophageal lesions, as assessed by endoscopy, in patients undergoing AF ablation assigned to a control group (luminal esophageal temperature [LET] monitoring alone) compared with patients randomized to a deviation group (esophagus deviation device + LET). This novel deviating device uses vacuum suction and mechanical deflection to deviate a segment of the esophagus, including the trailing edge. RESULTS: The data safety and monitoring board recommended stopping the study early after randomizing 120 patients due to deviating device efficacy. The primary study endpoint, ablation injury to the esophageal mucosa, was significantly less in the deviation group (5.7%) in comparison to the control group (35.4%; P < 0.0001). Control patients had a significantly higher severity and greater number of ablation lesions per patient. There was no adverse event assigned to the device. By multivariable analysis, the only feature associated with reduced esophageal lesions was randomization to deviating device (OR: 0.13; 95% CI: 0.04-0.46; P = 0.001). Among control subjects, there was no difference in esophageal lesions with high power/short duration (31.8%) vs other radiofrequency techniques (37.2%; P = 0.79). CONCLUSIONS: The use of an esophageal deviating device resulted in a significant reduction in ablation-related esophageal lesions without any adverse events.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Ablação por Radiofrequência , Humanos , Estudos Prospectivos , Ablação por Cateter/métodos , Esôfago/cirurgia
4.
J Innov Card Rhythm Manag ; 14(12): 5676-5680, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38155724

RESUMO

The ligament of Marshall is an embryological remnant of the left superior vena cava that contains neural tissues shown to be an arrhythmogenic source of atrial fibrillation (AF). Vein of Marshall (VOM) ethanol ablation is an ablation technique that can potentially treat AF by targeting the ligament of Marshall. We report a case of a patient who developed a pro-arrhythmic effect related to VOM ethanol ablation, which manifested as a perimitral flutter.

6.
J Cardiovasc Electrophysiol ; 34(8): 1698-1705, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37493499

RESUMO

INTRODUCTION: Among patients with non-valvular atrial fibrillation (AF) and percutaneous left atrial appendage closure (LAAC) undergoing direct current cardioversion (DCCV), the need for and use of LAA imaging and oral anticoagulation (OAC) is unclear. OBJECTIVE: The purpose of this study is to evaluate the real-world use of transesophageal echocardiography (TEE) or cardiac computed tomography angiography (CCTA) before DCCV and use of OAC pre- and post-DCCV in patients with AF status post percutaneous LAAC. METHODS: This retrospective single center study included all patients who underwent DCCV after percutaneous LAAC from 2016 to 2022. Key measures were completion of TEE or CCTA pre-DCCV, OAC use pre- and post-DCCV, incidence of left atrial thrombus (LAT) or device-related thrombus (DRT), incidence of peri-device leak (PDL), and DCCV-related complications (stroke, systemic embolism, device embolization, major bleeding, or death) within 30 days. RESULTS: A total of 76 patients with AF and LAAC underwent 122 cases of DCCV. LAAC consisted of 47 (62%), 28 (37%), and 1 (1%) case of Watchman 2.5, Watchman FLX, and Lariat, respectively. Among the 122 DCCV cases, 31 (25%) cases were identified as "non-guideline based" due to: (1) no OAC for 3 weeks and no LAA imaging within 48 h before DCCV in 12 (10%) cases, (2) no OAC for 4 weeks following DCCV in 16 (13%) cases, or (3) both in 3 (2%) cases. Among the 70 (57%) cases that underwent TEE or CCTA before DCCV, 16 (23%) cases had a PDL with a mean size of 3.0 ± 1.1 mm, and 4 (6%) cases had a LAT/DRT on TEE resulting in cancellation. There were no DCCV-related complications within 30 days. DISCUSSION: There is a widely varied practice pattern of TEE, CCTA, and OAC use with DCCV after LAAC, with a 6% rate of LAT/DRT. LAA imaging before DCCV appears prudent in all cases, especially within 1 year of LAAC, to assess for device position, PDL, and LAT/DRT.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Cardiopatias , Acidente Vascular Cerebral , Trombose , Humanos , Estudos Retrospectivos , Cardioversão Elétrica/efeitos adversos , Apêndice Atrial/diagnóstico por imagem , Trombose/diagnóstico por imagem , Trombose/etiologia , Trombose/prevenção & controle , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/terapia , Ecocardiografia Transesofagiana , Resultado do Tratamento , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Cateterismo Cardíaco/efeitos adversos
8.
J Innov Card Rhythm Manag ; 14(4): 5403-5409, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37143575

RESUMO

Persistent left superior vena cava (PLSVC) is the most common congenital thoracic venous anomaly, with 0.47% of patients undergoing pacemaker or cardiac implantable device placement found to have PLSVC. This review article describes challenges and interventions to successfully insert cardiac implantable electronic device leads into patients with PLSVC by providing multiple unique case examples.

9.
Pacing Clin Electrophysiol ; 46(7): 745-751, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37221927

RESUMO

BACKGROUND: Transesophageal echocardiography (TEE) and cardiac computed tomography angiography (CCTA) are currently utilized for left atrial appendage closure (LAAC) planning. During the recent global iodine contrast media shortage in 2022, cardiac magnetic resonance imaging (CMR) was utilized for the first time for LAAC planning. This study sought to assess the utility of CMR versus TEE for LAAC planning. METHODS: This single center retrospective study consisted of all patients who underwent preoperative CMR for LAAC with Watchman FLX or Amplatzer Amulet. Key measures were accuracy of LAA thrombus exclusion, ostial diameter, depth, lobe count, morphology, accuracy of predicted device size, and devices deployed per case. Bland-Altman Analysis was used to compare CMR versus TEE measurements of LAA ostial diameter and depth. RESULTS: 25 patients underwent preoperative CMR for LAAC planning. A total of 24 (96%) cases were successfully completed with 1.2 ± 0.5 devices deployed per case. Among the 18 patients who underwent intraoperative TEE, there was no significant difference between CMR versus TEE in LAA thrombus exclusion (CMR 83% vs. TEE 100% cases, p = .229), lobe count (CMR 1.7 ± 0.8 vs. TEE 1.4 ± 0.6, p = .177), morphology (p = .422), and accuracy of predicted device size (CMR 67% vs. TEE 72% cases, p = 1.000). When comparing the difference between CMR and TEE measurements, Bland-Altman analysis demonstrated no significant difference in LAA ostial diameter (CMR-TEE bias 0.7 mm, 95% CI [-1.1, 2.4], p = .420), but LAA depth was significantly larger with CMR versus TEE (CMR-TEE bias 7.4 mm, 95% CI [1.6, 13.2], p = .015). CONCLUSIONS: CMR is a promising alternative for LAAC planning in cases where TEE or CCTA are contraindicated or unavailable.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Trombose , Humanos , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Estudos Retrospectivos , Ecocardiografia Transesofagiana/métodos , Imageamento por Ressonância Magnética , Trombose/diagnóstico por imagem , Cateterismo Cardíaco , Resultado do Tratamento
10.
JACC Clin Electrophysiol ; 8(6): 795-799, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35738857

RESUMO

Thirty-eight patients had assessment of pulmonary vein occlusion with the dielectric mapping system and injection of saline as an alternative to contrast. Contrast injection was required to ascertain pulmonary vein occlusion in 31.6% (12 of 38) of subjects and 17.4% (27 of 155) of veins. No contrast was required in the last 13 subjects. In this single center study, a novel mapping-guided cryoablation approach appeared to minimize the use of contrast in pulmonary vein isolation for the treatment of atrial fibrillation.


Assuntos
Fibrilação Atrial , Criocirurgia , Veias Pulmonares , Pneumopatia Veno-Oclusiva , Fibrilação Atrial/cirurgia , Criocirurgia/efeitos adversos , Estudos de Viabilidade , Humanos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Pneumopatia Veno-Oclusiva/cirurgia , Resultado do Tratamento
11.
J Cardiovasc Electrophysiol ; 33(8): 1813-1822, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35671363

RESUMO

BACKGROUND: Sudden cardiac death (SCD) is common after orthotopic heart transplant (OHT). No clear guidelines for implantable cardioverter defibrillator (ICD) implantation in OHT patients at high risk for SCD currently exist. OBJECTIVES: To assess the safety, efficacy, and benefit of ICDs and resynchronization therapy post-OHT. We also provide a systematic review of previous reports. METHODS: A retrospective multicenter cohort study within the United States. Patients with ICD post-OHT between 2000 and 2020 were identified. RESULTS: We analyzed 16 patients from 4 centers. The mean standard-deviation (SD) age was 43 (18) years at OHT and 51 (20) years at ICD implantation. The mean (SD) duration from OHT to ICD implantation was 9 (5) years. The mean (SD) left ventricular ejection fraction (LVEF) was 35% (17%). There were 2 (13%) postprocedural complications: 1 hematoma and 1 death. Mean (SD) follow-up was 24 (23) months. Survival rate was 63% (10/16) at 1 year and 56% (9/16) at 2 years, with 6/7 of those who died having LVEF < 35% at the time of the ICD implantation. Patients were more likely to receive appropriate therapy if their ICD was implanted for secondary (5/8) rather than primary (0/8) prevention (p = .007). Of those who did, 4 patients survived to 30 days post-ICD therapy. Severe CAV was not associated with the rate of appropriate therapy. CONCLUSIONS: Beneficial outcomes were observed when ICDs were implanted for secondary prevention only, and in patients with higher baseline LVEF. We also observed benefits with resynchronization therapy.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca , Transplante de Coração , Adulto , Estudos de Coortes , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Transplante de Coração/efeitos adversos , Humanos , Estudos Multicêntricos como Assunto , Estudos Retrospectivos , Fatores de Risco , Volume Sistólico , Estados Unidos , Função Ventricular Esquerda
12.
J Cardiovasc Electrophysiol ; 32(11): 3027-3034, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34554620

RESUMO

INTRODUCTION: Defibrillation testing (DT) is recommended during the subcutaneous defibrillator (S-ICD) placement. We sought to compare 10 J shock impedance in sinus rhythm (SR) with 65 J defibrillation impedance and evaluate device position on a postimplant chest X-ray (CXR) using an intermuscular (IM) technique. METHODS: Consecutive S-ICD implantations between 12/2019 and 12/2020 at The Ohio State University were reviewed. All implantations were performed using a two-incision IM technique. Standard DT with 65 J shock and 10 J shock in SR were performed unless contraindicated. The PRAETORIAN score was calculated based on CXR. RESULTS: A total of 37 patients (age: 47.2 ± 15.8 years old, male: n = 26 [70.3%], body mass index: 30.1 ± 6.7 kg/m2 ) underwent IM S-ICD implantation, and of those, 27 (73%) underwent both 65 J shock and 10 J shock in SR. The coefficient of determination (R2 ) between 10 J shock impedance and 65 J shock impedance was 0.84. The mean of an impedance difference was 1.6 ± 4.8 Ω (minimum - 11 and maximum 8). Postimplant CXR was available for 33 out of 37 patients (89.2%). The PRAETORIAN score was less than 90 in all patients and the mean score was 32.7 ± 8.8. CONCLUSION: We demonstrated that 10 J shock impedance in SR correlated well with 65 J defibrillation impedance during IM S-ICD implantation. An IM implantation technique provides excellent generator location on postimplant CXR. The IM technique combined with 10 J shock in SR may be sufficient to predict and ensure the defibrillation efficacy of the S-ICD.


Assuntos
Desfibriladores Implantáveis , Adulto , Arritmias Cardíacas , Cardioversão Elétrica , Impedância Elétrica , Humanos , Masculino , Pessoa de Meia-Idade , Ohio , Tela Subcutânea
16.
J Cardiovasc Electrophysiol ; 32(10): 2824-2829, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33556991

RESUMO

Esophageal injury still occurs with high frequency during ablation of atrial fibrillation (AF). The purpose of this study is to provide a review of methods to protect the esophagus from injury during AF ablation. Despite advances in imaging and ablation, the potential risk of esophageal injury during AF ablation remains an important concern with a high occurrence of esophageal injury (≈15%). There have been numerous studies evaluating varied techniques for esophageal protection including active cooling and displacement of the esophagus. These techniques are reviewed in this manuscript as well as the role of esophageal protection in managing patients undergoing AF ablation procedure.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Esôfago/diagnóstico por imagem , Esôfago/cirurgia , Humanos
17.
JACC Clin Electrophysiol ; 7(6): 745-754, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33516715

RESUMO

OBJECTIVES: This study reports resource use and economic implications of rhythm monitoring with subcutaneous cardiac rhythm monitors (SCRMs). BACKGROUND: SCRMs generate a substantial amount of data that requires timely adjudication for appropriate clinical care. Resource use for SCRM monitoring is not known. METHODS: The study included consecutive transmissions during 4 weeks from 1,811 SCRMs. Resource use was quantified by assessment of time commitment of device clinic personnel and electrophysiologists for data adjudication. Incidence and characteristics of false positive (FP) episodes were assessed. Impact of custom programming for arrhythmia detection on incidence of FP episodes and resource use was analyzed. RESULTS: A total of 1,457 transmissions (alerts = 462; full downloads = 995) were received during study period. Average device clinic personnel time for adjudication of 1 transmission was 15 ± 6 min. This totaled to 364 h spent (2.3 full-time staff) over the 4-week period, which translated into a salary cost of $12,000 U.S. dollars (USD). Average time spent by an electrophysiologist for 1 transmission was 1.5 ± 1 min and totaled to 37 h for 4 weeks, which translated into an estimated cost of $9,600 USD. Of 1,457 total transmissions, 512 (35%) represented multiple transmissions from the same patients, which resulted in no additional reimbursement. Incidence of FP episodes in the entire cohort was 50% and was variable in alert (60%) and full download (49%) (p = 0.04) transmissions. When SCRMs with manufacturer suggested nominal programming and institutional custom programming were compared, there was a reduction in FP episodes (55% vs. 16%; p = 0.01), which translated to a 34% reduction in resource use for data adjudication. CONCLUSIONS: SCRM data adjudication requires significant resources. Custom programming for SCRMs may overcome the data deluge.


Assuntos
Desfibriladores Implantáveis , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/epidemiologia , Humanos , Incidência , Monitorização Fisiológica
18.
J Cardiovasc Electrophysiol ; 32(2): 477-483, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33205561

RESUMO

INTRODUCTION: Frequent right AQ4ventricular pacing (≥40%) with a transvenous pacemaker (TVP) is associated with the risk of pacing-induced cardiomyopathy (PICM). Leadless pacemakers (LPs) have distinct physical and mechanical differences from TVP. The risk of PICM with LP is not known. To identify incidence, predictors, and long-term outcomes of PICM in LP and TVP patients. METHODS: The study comprised all pacemaker-dependent patients with LP or TVP who had left ventricular ejection fraction (LVEF) of ≥50 from 2014 to 2019. The incidence of PICM (≥10% LVEF drop) was assessed with an echocardiogram. Predictors for PICM were identified using multivariate analysis. Long-term outcomes after cardiac resynchronization (CRT) were assessed in both groups. RESULTS: A total of 131 patients with TVP and 67 with LP comprised the study. All patients in the TVP group and the majority in the LP group underwent atrioventricular node ablation. The mean follow-up duration in TVP and LP groups was 592 ± 549 and 817 ± 600 days, respectively. A total of 18 (13.7%) patients in TVP and 2 (3%) in LP developed PICM after a median duration of 254 (interquartile range: 470) days. The incidence of PICM was significantly higher with TVP compared with LP (p = .02). TVP as pacing modality was a positive (odds ratio [OR]: 1.07) while age was negative (OR: 0.94) predictor for PICM on multivariable analysis. Both patients in LP and all except two in the TVP group responded to CRT. CONCLUSION: Incidence of PICM is significantly lower with LP compared with TVP in pacemaker-dependent patients. Age and TVP as pacing modality were predictors for PICM.


Assuntos
Cardiomiopatias , Marca-Passo Artificial , Estimulação Cardíaca Artificial/efeitos adversos , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/epidemiologia , Humanos , Incidência , Marca-Passo Artificial/efeitos adversos , Estudos Retrospectivos , Volume Sistólico , Função Ventricular Esquerda
20.
JACC Clin Electrophysiol ; 6(10): 1318-1331, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-33092762

RESUMO

Leadless pacemakers (LPs) have emerged as a meaningful alternative to transvenous pacemakers for single-ventricular pacing. LPs eliminate many of lead- and pocket-associated complications observed with transvenous pacemakers. Owing to the lack of atrioventricular synchronous pacing until recently, the use of LP was generally reserved for those patients who either required minimal ventricular pacing or had permanent atrial fibrillation. The only commercially available LP is the Micra transcatheter pacing system (Micra-TPS, Medtronic Inc. Fridley, Minnesota), which requires insertion of a 27-F (outer diameter) introducer sheath in the femoral vein. The LP is delivered to the right ventricle using a 23-F delivery catheter. Owing to the need for a large-bore sheath, the pivotal studies for the Micra transcatheter pacing system excluded patients with indwelling inferior vena cava filters and included only a few patients with bioprosthetic or repaired tricuspid valve. Subsequent real-world experience has demonstrated the overall safety and feasibility of LP placement, and use in various unconventional clinical settings has been validated, albeit with specific precautions. Additionally, incorporation of adjunctive techniques and strategies can improve the safety of the procedure in routine clinical settings as well. The objective of this state-of-the-art review is to highlight the key procedural elements to facilitate safe and efficient implantation of LP in routine as well as in unique clinical settings.


Assuntos
Fibrilação Atrial , Marca-Passo Artificial , Estimulação Cardíaca Artificial , Humanos , Minnesota , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...