Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
1.
Breast ; 74: 103693, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38430905

RESUMO

BACKGROUND: High breast density is an independent risk factor for breast cancer and decreases the sensitivity of mammography. This systematic review synthesizes the evidence on the impact of breast density (BD) information and/or notification on women's psychosocial outcomes among women from racial and ethnic minority groups. METHODS: A systematic search was performed in March 2023, and the articles were identified using CINHAL, Embase, Medline, and PsychInfo databases. The search strategy combined the terms "breast", "density", "notification" and synonyms. The authors specifically kept the search terms broad and did not include terms related to race and ethnicity. Full-text articles were reviewed for analysis by race, ethnicity and primary language of participants. Two authors evaluated the eligibility of studies with verification from the study team, extracted and crosschecked data, and assessed the risk of bias. RESULTS: Of 1784 articles, 32 articles published from 2003 to 2023 were included. Thirty-one studies were conducted in the United States and one in Australia, with 28 quantitative and four qualitative methodologies. The overall results in terms of breast density awareness, knowledge, communication with healthcare professionals, screening intentions and supplemental screening practice were heterogenous across studies. Barriers to understanding BD notifications and intentions/access to supplemental screening among racial and ethnic minorities included socioeconomic factors, language, health literacy and medical mistrust. CONCLUSIONS: A one-size approach to inform women about their BD may further disadvantage racial and ethnic minority women. BD notification and accompanying information should be tailored and translated to ensure readability and understandability by all women.


Assuntos
Densidade da Mama , Neoplasias da Mama , Feminino , Humanos , Estados Unidos , Neoplasias da Mama/psicologia , Etnicidade , Minorias Étnicas e Raciais , Confiança , Grupos Minoritários
2.
EClinicalMedicine ; 44: 101282, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35128368

RESUMO

BACKGROUND: Advances in breast cancer (BC) care have reduced mortality, but their impact on survival once diagnosed with metastasis is less well described. This systematic review aimed to describe population-level survival since 1995 for de novo metastatic BC (dnMBC) and recurrent MBC (rMBC). METHODS: We searched MEDLINE 01/01/1995-12/04/2021 to identify population-based cohort studies of MBC reporting overall (OS) or BC-specific survival (BCSS) over time. We appraised risk-of-bias and summarised survival descriptively for MBC diagnoses in 5-year periods from 1995 until 2014; and for age, hormone receptor and HER2 subgroups. FINDINGS: We identified 20 eligible studies (14 dnMBC, 1 rMBC, 5 combined). Potential sources of bias in these studies were confounding and shorter follow-up for the latest diagnosis period.For dnMBC, 13 of 14 studies reported improved OS or BCSS since 1995. In 2005-2009, the median OS was 26 months (range 24-30), a median gain of 6 months since 1995-1999 (range 0-9, 4 studies). Median 5-year OS was 23% in 2005-2009, a median gain of 7% since 1995-1999 (range -2 to 14%, 4 studies). For women ≥70 years, the median and 5-year OS was unchanged (1 study) with no to modest difference in relative survival (range: -1·9% (p = 0.71) to +2·1% (p = 0.045), 3 studies). For rMBC, one study reported no change in survival between 1998 and 2006 and 2007-2013 (median OS 23 months). For combined MBC, 76-89% had rMBC. Three of four studies observed no change in median OS after 2000. Of these, one study reported median OS improved for women ≤60 years (1995-1999 19·1; 2000-2004 22·3 months) but not >60 years (12·7, 11·6 months). INTERPRETATION: Population-level improvements in OS for dnMBC have not been consistently observed in rMBC cohorts nor older women. These findings have implications for counselling patients about prognosis, planning cancer services and trial stratification. FUNDING: SL was funded in part by a National Health and Medical Research Council (NHMRC) Project Grant ID: 1125433. NH was funded by the NBCF Chair in Breast Cancer Prevention grant (EC-21-001) and a NHMRC Investigator (Leader) grant (194410). BD and SAP were funded in part by the NHMRC Centre of Research Excellence in Medicines Intelligence (1196900).

3.
Br J Surg ; 108(7): 760-768, 2021 07 23.
Artigo em Inglês | MEDLINE | ID: mdl-34057990

RESUMO

BACKGROUND: In patients with triple-negative breast cancer (TNBC), oncological and survival outcomes based on locoregional treatment are poorly understood. In particular, the safety of breast-conserving surgery (BCS) for TNBC has been questioned. METHODS: A meta-analysis was performed to evaluate locoregional recurrence (LRR), distant metastasis (DM), and overall survival (OS) rates in patients with TNBC who had breast-conserving surgery versus mastectomy. Estimates were pooled in random-effects analysis. The effect of study-level co-variables was assessed by univariable metaregression. RESULTS: Fourteen studies, including 19 819 patients operated for TNBC met the inclusion criteria; 9828 patients (49.6 per cent) underwent BCS and 9991 (50.4 per cent) had a mastectomy. Patients with smaller tumours were more likely to be selected for BCS (pooled odds ratio (OR) for T1 tumours 1.95, 95 per cent c.i. 1.64 to 2.32; P < 0.001). The pooled OR for LRR was 0.64 (0.48 to 0.85; P = 0.002), indicating a statistically significantly lower odds of LRR among women who had BCS relative to mastectomy. The pooled OR for DM was 0.70 (0.53 to 0.94; P = 0.02), indicating a lower odds of DM among women who had BCS; however, this difference diminished with increasing study-level age and follow-up time. A pooled hazard ratio of 0.78 (0.69 to 0.89; P < 0.001) showed a significantly lower hazard for all-cause mortality among women undergoing BCS versus mastectomy. CONCLUSION: These results should be interpreted cautiously owing to likely differences in selection for BCS or mastectomy in the included studies. Patients with TNBC selected for BCS do not, however, have a worse prognosis than those treated with mastectomy, and breast conservation can be offered when feasible clinically.


Assuntos
Mastectomia Segmentar/métodos , Estadiamento de Neoplasias , Neoplasias de Mama Triplo Negativas/cirurgia , Feminino , Humanos , Resultado do Tratamento , Neoplasias de Mama Triplo Negativas/diagnóstico
4.
Clin Radiol ; 74(12): 974.e1-974.e6, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31521327

RESUMO

AIM: To compare a standard intra-operative mammography (IM) device with digital breast tomosynthesis using a dedicated device (Mozart system) in the evaluation of surgical margins at first excision. MATERIALS AND METHODS: The study received institutional review board approval and written informed consent was obtained from participants. From January 2018 to December 2018, a prospective analysis of the images of IM device and intra-operative digital breast tomosynthesis with a dedicated device (Mozart system) in n=89 breast cancer patients (average patients age: 58 years, age range: 35-76 years) was undertaken. Images were evaluated by two expert breast radiologists independently of each other and blinded to each other's interpretation, who indicated the positive cases requiring surgical re-excision intra-operatively. RESULTS: Mean cancer size was 12.5±4.5 mm. Radiological signs of the lesions were microcalcifications (n=71), nodules (n=10), and architectural distortions (n=8). A total of 20/89 (17%) patients underwent intra-operative re-excision for positive margins. Intra-operative digital breast tomosynthesis with a dedicated device and IM showed discrepancies in 15/89 cases (17%). Mozart system results informed the necessity to perform a re-excision (n=15). Overall, receiver operating characteristic (ROC) curve analysis showed and area under the ROC curve (AUC) of 0.82 for the Mozart system versus 0.65 for IM. ROC analysis of radiological findings with microcalcifications showed an AUC of 0.92 for the Mozart system versus 0.74 for IM, whereas AUC in cases with no microcalcifications were 0.87 and 0.75, respectively. CONCLUSION: Intra-operative digital breast tomosynthesis with a dedicated device provides more information (better accuracy) than IM and facilitated a reduction in re-excision rates.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mamografia , Margens de Excisão , Adulto , Idoso , Neoplasias da Mama/patologia , Neoplasias da Mama/cirurgia , Calcinose/diagnóstico por imagem , Feminino , Humanos , Período Intraoperatório , Mamografia/métodos , Mastectomia Segmentar/métodos , Pessoa de Meia-Idade
5.
Breast ; 45: 70-74, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30884341

RESUMO

PURPOSE: Follow-up schemes in breast cancer survivors are predominantly consensus-based. To determine evidence-based follow-up intervals, estimates of sensitivity of the screening test(s) and duration of the preclinical detectable phase (PCDP) are key. We estimated the sensitivity and the duration of the PCDP of clinical breast examination (CBE) and mammography for the detection of contralateral second breast cancers (CBC) in breast cancer survivors. METHODS: Women with a CBC (N = 589) diagnosed in Florence between 1980 and 2005 were included. Test sensitivity and the duration of PCDP were estimated using a simple exponential model of PCDP duration. Analyses were stratified by follow-up period (0-5 vs. >5 years after primary diagnosis) and age at CBC diagnosis (<50 vs. ≥50 years). RESULTS: For CBE, test sensitivity was 55% and the duration of the PCDP 16 months. Mammography sensitivity was 91% and duration of the PCDP 35 months. Stratified analyses showed a higher test sensitivity for CBE for women aged <50 (70% vs. 51%). No difference in the duration of PCDP of CBE was found. For mammography, test sensitivity and the duration of the PCDP were higher for women with longer follow-up and in older women. CONCLUSIONS: Poor test sensitivity for CBE with a shorter duration of the PCDP compared with mammography were observed. Mammography had high test sensitivity and the potential to detect CBCs early. The estimated duration of the PCDP (35 months) was considerably longer than the recommended follow-up interval (12 months). Future studies are needed to determine whether a longer follow-up interval is appropriate.


Assuntos
Assistência ao Convalescente/estatística & dados numéricos , Neoplasias da Mama/diagnóstico , Detecção Precoce de Câncer/estatística & dados numéricos , Mamografia/estatística & dados numéricos , Segunda Neoplasia Primária/diagnóstico , Adulto , Assistência ao Convalescente/métodos , Idoso , Sobreviventes de Câncer , Detecção Precoce de Câncer/métodos , Medicina Baseada em Evidências , Feminino , Humanos , Mamografia/métodos , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade , Fatores de Tempo
6.
Clin Radiol ; 73(8): 735-743, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29678274

RESUMO

AIM: To identify clinically occult nipple-areola complex (NAC) involvement using preoperative magnetic resonance imaging (MRI), to inform selection of patients eligible for nipple-sparing mastectomy (NSM) or skin-sparing mastectomy (SSM). MATERIAL AND METHODS: This was a retrospective study of 195 patients, who had preoperative breast MRI (February 2011 to January 2017) before undergoing surgical treatments (NSM or SSM) for newly diagnosed breast cancer. Tumour features at MRI (mass or non-mass lesion, diameter, lesion-NAC distance [LND]) and pathology (lesion diameter, histopathological type, receptor status) were recorded, as well as the type of surgery (NSM/SSM) and presence (NAC+) or absence (NAC-) of tumour at intraoperative evaluation of retroareolar tissue. Mann-Whitney test, Fisher's exact test, logistic regression, and receiver operating characteristic (ROC) curve analysis were used for analysis of NAC+ versus NAC- to assess variables that predict NAC tumoural involvement. RESULTS: Over the study period, NAC+ was proven histologically in 71/200 (35.5%) surgical treatments, while there were 129/200 NAC- (72 NSM and 128 SSM performed). LND at MRI was statistically (p<0.001) lower in NAC+ patients than in NAC- patients. The area under the ROC curve (0.82, 95% confidence interval [CI]: 0.76-0.88) indicated 10 mm as the best cut-off, with sensitivity of 82%, specificity of 72%, and accuracy of 79%. A 5-mm cut-off enhanced sensitivity, whereas a 15-mm cut-off favoured specificity. CONCLUSIONS: MRI is a useful tool for identifying NAC+ patients; a 10-mm cut-off for LND assists selection of patients for NSM, although intraoperative retroareolar tissue examination remains mandatory.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Imageamento por Ressonância Magnética/métodos , Mamilos/diagnóstico por imagem , Mamilos/patologia , Cuidados Pré-Operatórios , Adulto , Idoso , Neoplasias da Mama/cirurgia , Meios de Contraste , Feminino , Humanos , Meglumina/análogos & derivados , Pessoa de Meia-Idade , Mamilos/cirurgia , Compostos Organometálicos , Seleção de Pacientes , Estudos Retrospectivos , Sensibilidade e Especificidade
7.
Eur Radiol ; 28(2): 573-581, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28819862

RESUMO

OBJECTIVES: To compare radiation dose delivered by digital mammography (FFDM) and breast tomosynthesis (DBT) for a single view. METHODS: 4,780 FFDM and 4,798 DBT images from 1,208 women enrolled in a screening trial were used to ground dose comparison. Raw images were processed by an automatic software to determine volumetric breast density (VBD) and were used together with exposure data to compute the mean glandular dose (MGD) according to Dance's model. DBT and FFDM were compared in terms of operation of the automatic exposure control (AEC) and MGD level. RESULTS: Statistically significant differences were found between FFDM and DBT MGDs for all views (CC: MGDFFDM=1.366 mGy, MGDDBT=1.858 mGy; p<0.0001; MLO: MGDFFDM=1.374 mGy, MGDDBT=1.877 mGy; p<0.0001). Considering the 4,768 paired views, Bland-Altman analysis showed that the average increase of DBT dose compared to FFDM is 38 %, and a range between 0 % and 75 %. CONCLUSIONS: Our findings show a modest increase of radiation dose to the breast by tomosynthesis compared to FFDM. Given the emerging role of DBT, its use in conjunction with synthetic 2D images should not be deterred by concerns regarding radiation burden, and should draw on evidence of potential clinical benefit. KEY POINTS: • Most studies compared tomosynthesis in combination with mammography vs. mammography alone. • There is some concern about the dose increase with tomosynthesis. • Clinical data show a small increase in radiation dose with tomosynthesis. • Synthetic 2D images from tomosynthesis at zero dose reduce potential harm. • The small dose increase should not be a barrier to use of tomosynthesis.


Assuntos
Neoplasias da Mama/diagnóstico , Mama/diagnóstico por imagem , Mamografia/métodos , Intensificação de Imagem Radiográfica/métodos , Adulto , Densidade da Mama , Feminino , Humanos , Pessoa de Meia-Idade , Doses de Radiação
8.
Clin Radiol ; 71(9): 889-95, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27210245

RESUMO

AIM: To examine the interpretive performance of digital breast tomosynthesis (DBT) as an adjunct to digital mammography (DM) compared to DM alone in a series of invasive lobular carcinomas (ILCs) and to assess whether DBT can be used to characterise ILC. MATERIALS AND METHODS: A retrospective, multi-reader study was conducted of 83 mammographic examinations of women with 107 newly diagnosed ILCs ascertained at histology. Consenting women underwent both DM and DBT acquisitions. Twelve radiologists, with varying mammography experience, interpreted DM images alone, reporting lesion location, mammographic features, and malignancy probability using the Breast Imaging-Reporting and Data System (BI-RADS) categories 1-5; they then reviewed DBT images in addition to DM, and reported the same parameters. Statistical analyses compared sensitivity, false-positive rates (FPR), and interpretive performance using the receiver operating characteristics (ROC) curve and the area under the curve (AUC), for reading with DM versus DM plus DBT. RESULTS: Multi-reader pooled ROC analysis for DM plus DBT yielded AUC=0.89 (95% confidence interval [CI]: 0.88-0.91), which was significantly higher (p<0.0001) than DM alone with AUC=0.84 (95% CI: 0.82-0.86). DBT plus DM significantly increased pooled sensitivity (85%) compared to DM alone (70%; p<0.0001). FPR did not vary significantly with the addition of DBT to DM. Interpreting with DBT (compared to DM alone) increased the correct identification of ILCs depicted as architectural distortions (84% versus 65%, respectively) or as masses (89% versus 70%), increasing interpretive performance for both experienced and less-experienced readers; larger gains in AUC were shown for less-experienced radiologists. Multifocal and/or multicentric and bilateral disease was more frequently identified on DM with DBT. CONCLUSION: Adding DBT to DM significantly improved the accuracy of mammographic interpretation for ILCs and contributed to characterising disease extent.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Carcinoma Lobular/diagnóstico por imagem , Carcinoma Lobular/patologia , Mamografia/métodos , Intensificação de Imagem Radiográfica/métodos , Idoso , Detecção Precoce de Câncer/métodos , Feminino , Humanos , Imageamento Tridimensional/métodos , Pessoa de Meia-Idade , Imagem Multimodal/métodos , Invasividade Neoplásica , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos
9.
Br J Surg ; 102(8): 883-93, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25919321

RESUMO

BACKGROUND: MRI has been used increasingly in the diagnosis and management of women with invasive breast cancer. However, its usefulness in the preoperative assessment of ductal carcinoma in situ (DCIS) remains questionable. A meta-analysis was conducted to examine the effects of MRI on surgical treatment of DCIS by analysing studies comparing preoperative MRI with conventional preoperative assessment. METHODS: Using random-effects modelling, the proportion of women with various outcomes in the MRI versus no-MRI groups was estimated, and the odds ratio (OR) and adjusted OR (adjusted for study-level median age) for each model were calculated. RESULTS: Nine eligible studies were identified that included 1077 women with DCIS who had preoperative MRI and 2175 who did not. MRI significantly increased the odds of having initial mastectomy (OR 1·72, P = 0·012; adjusted OR 1·76, P = 0·010). There were no significant differences in the proportion of women with positive margins following breast-conserving surgery (BCS) in the MRI and no-MRI groups (OR 0·80, P = 0·059; adjusted OR 1·10, P = 0·716), nor in the necessity of reoperation for positive margins after BCS (OR 1·06, P = 0·759; adjusted OR 1·04, P = 0·844). Overall mastectomy rates did not differ significantly according to whether or not MRI was performed (OR 1·23, P = 0·340; adjusted OR 0·97, P = 0·881). CONCLUSION: Preoperative MRI in women with DCIS is not associated with improvement in surgical outcomes.


Assuntos
Neoplasias da Mama/cirurgia , Carcinoma Ductal de Mama/cirurgia , Carcinoma Intraductal não Infiltrante/cirurgia , Imageamento por Ressonância Magnética , Cuidados Pré-Operatórios , Neoplasias da Mama/patologia , Carcinoma Ductal de Mama/patologia , Carcinoma Intraductal não Infiltrante/patologia , Feminino , Humanos , Mastectomia , Mastectomia Segmentar
10.
Radiat Prot Dosimetry ; 165(1-4): 314-20, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25848107

RESUMO

Clinical studies using different imaging protocols to perform digital breast tomosynthesis (DBT) were reviewed (2008-14) to assess interpretive accuracy. Descriptive pooled statistics were used to estimate and summarise accuracy measures for each type of imaging protocol in relation to that of two-view full-field digital mammography (FFDM). In studies comparing multiple DBT imaging protocols, a trend of increased performance was often seen when including both the mediolateral oblique and craniocaudal views for DBT alone and even more so for DBT adjunct to FFDM. Overall, the average ΔAUC (%; sd) across studies for stand-alone DBT (relative to FFDM), in one and in two views, were 2.2 (± 3.7) and 5.9 (± 4.6), and when used together with FFDM, 3.9 (± 2.0) and 6.7 (± 0.9). With respect to individual studies, improvements in accuracy using DBT were present for different types of imaging protocols although the magnitude of the impact varied between studies, and some studies did not show significant improvements in comparison with FFDM. The most consistent effect of improvement in breast cancer detection was seen across studies for two-view DBT with FFDM. These summary findings may depend on the sampling constraints present in tomosynthesis imaging and on other factors discussed in this paper. In order to investigate these effects more thoroughly and how they might impact outcomes, comparative or randomized-controlled trials are warranted.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/diagnóstico , Mama/patologia , Mamografia/métodos , Intensificação de Imagem Radiográfica/métodos , Área Sob a Curva , Ensaios Clínicos como Assunto , Reações Falso-Positivas , Feminino , Humanos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Reprodutibilidade dos Testes
11.
Radiat Prot Dosimetry ; 165(1-4): 331-6, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25855075

RESUMO

Three reconstruction algorithms for digital breast tomosynthesis were compared in this article: filtered back-projection (FBP), iterative adapted FBP and maximum likelihood-convex iterative algorithms. Quality metrics such as signal-difference-to-noise ratio, normalised line-profiles and artefact-spread function were used for evaluation of reconstructed tomosynthesis images. The iterative-based methods offered increased image quality in terms of higher detectability and reduced artefacts, which will be further examined in clinical images.


Assuntos
Mamografia/métodos , Intensificação de Imagem Radiográfica/métodos , Algoritmos , Artefatos , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Imagens de Fantasmas , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Espalhamento de Radiação , Razão Sinal-Ruído , Software
12.
Breast ; 24(2): 93-9, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25554018

RESUMO

We examined how radiation dose levels in digital breast tomosynthesis (DBT) differ from those used in 2-view full-field digital mammography (FFDM). Acquisition parameter settings and information on the average absorbed dose to the glandular tissues within the breasts were reviewed based on clinical studies that evaluated DBT and FFDM. Dose ratios (DDBT/DFFDM) were derived from imaging protocols, which included tomosynthesis in 1- or 2-views alone, and as an adjunct technique to FFDM. Stand-alone DBT was associated with a much lower to a slightly higher radiation dose compared to that of comparable FFDM units, as summarized in dose ratio ranges of 0.34-1.0 for 1-view DBT, and 0.68-1.17 for 2-view DBT. One of the lowest reported dose estimates was obtained using a photon-counting DBT unit (avg. 0.70 mGy/scan; range: 0.28-1.26 mGy). Breast doses for DBT combined with FFDM are summarized in dose ratio ranges of 1.03-1.5 for 1-view DBT plus FFDM, and 2.0-2.23 for 2-view DBT plus FFDM. In the latter of these settings, the dose was reduced by ∼45% when 2D-views, reconstructed from the DBT images ("synthetic 2D images"), were used as a substitute for FFDM. Stand-alone DBT operated at lower to slightly higher radiation doses in comparison to FFDM. For DBT combined with FFDM, radiation doses were elevated, at maximum by a factor ∼2 1/4 of that of FFDM alone. In this setting, a replacement of FFDM with synthetic 2D-views reduced the breast dose approximately by half, which has substantial implications for population screening programs.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mamografia/métodos , Detecção Precoce de Câncer , Feminino , Humanos , Doses de Radiação , Intensificação de Imagem Radiográfica , Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia Computadorizada por Raios X
15.
Intern Med J ; 44(8): 764-70, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24863750

RESUMO

BACKGROUND: There is limited information on the risk of metastatic breast cancer (MBC) to inform younger women, particularly those under 40 years. AIMS: We conducted a retrospective analysis of a population-based cohort study to describe the risk, site and prognosis of MBC in young women under 40 years with an initial diagnosis of non-metastatic breast cancer and compared with older women. METHODS: Data were extracted from the New South Wales Central Cancer Registry and the Admitted Patient Data Collection database between 2001-2007. Main outcome measures were 5-year cumulative incidence of MBC, prognostic factors for MBC and overall survival (OS) from the date of MBC diagnosis. RESULTS: Three hundred and ninety-five (6%) of 6640 women with non-metastatic BC were <40 years. The 5-year cumulative incidence of MBC was 24% (95% CI 20-29%) for women <40 years with non-metastatic BC, compared with 9% (95% CI 9-10%) for women ≥40 years. Significant independent risk factors for MBC ≤ 5 years were age <40, regional disease at diagnosis, low socioeconomic status and the presence of other non-breast primary. At first record of MBC, visceral sites were more common for women <40 years than ≥40 (54% vs 43%; P = 0.03). Median survival for women with MBC within 5 years was not significantly different between young and older women (<40 years 18 months vs ≥40 years 14 months; log-rank P = 0.21). CONCLUSIONS: Women with non-metastatic BC before age 40 have a higher 5-year risk of developing MBC than older women. There were no significant differences in median survival following MBC between young and older women.


Assuntos
Neoplasias da Mama/epidemiologia , Neoplasias da Mama/secundário , Vigilância da População , Adulto , Fatores Etários , Idoso , Feminino , Seguimentos , Humanos , Incidência , Pessoa de Meia-Idade , Metástase Neoplásica , New South Wales/epidemiologia , Prognóstico , Estudos Retrospectivos , Fatores de Risco , Taxa de Sobrevida/tendências , Adulto Jovem
17.
Br J Radiol ; 86(1031): 20130255, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24029631

RESUMO

OBJECTIVE: To compare breast density estimated from two-dimensional full-field digital mammography (2D FFDM) and from digital breast tomosynthesis (DBT) according to different Breast Imaging-Reporting and Data System (BI-RADS) categories, using automated software. METHODS: Institutional review board approval and written informed patient consent were obtained. DBT and 2D FFDM were performed in the same patients to allow within-patient comparison. A total of 160 consecutive patients (mean age: 50±14 years; mean body mass index: 22±3) were included to create paired data sets of 40 patients for each BI-RADS category. Automatic software (MedDensity(©), developed by Giulio Tagliafico) was used to compare the percentage breast density between DBT and 2D FFDM. The estimated breast percentage density obtained using DBT and 2D FFDM was examined for correlation with the radiologists' visual BI-RADS density classification. RESULTS: The 2D FFDM differed from DBT by 16.0% in BI-RADS Category 1, by 11.9% in Category 2, by 3.5% in Category 3 and by 18.1% in Category 4. These differences were highly significant (p<0.0001). There was a good correlation between the BI-RADS categories and the density evaluated using 2D FFDM and DBT (r=0.56, p<0.01 and r=0.48, p<0.01, respectively). CONCLUSION: Using DBT, breast density values were lower than those obtained using 2D FFDM, with a non-linear relationship across the BI-RADS categories. These data are relevant for clinical practice and research studies using density in determining the risk. ADVANCES IN KNOWLEDGE: On DBT, breast density values were lower than with 2D FFDM, with a non-linear relationship across the classical BI-RADS categories.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mamografia/métodos , Intensificação de Imagem Radiográfica/métodos , Mama/citologia , Mama/patologia , Detecção Precoce de Câncer/métodos , Feminino , Humanos , Pessoa de Meia-Idade , Software , Tomografia por Raios X
18.
Br J Cancer ; 109(6): 1528-36, 2013 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-23963140

RESUMO

BACKGROUND: Magnetic resonance imaging (MRI) has been proposed to guide breast cancer surgery by measuring residual tumour after neoadjuvant chemotherapy. This study-level meta-analysis examines MRI's agreement with pathology, compares MRI with alternative tests and investigates consistency between different measures of agreement. METHODS: A systematic literature search was undertaken. Mean differences (MDs) in tumour size between MRI or comparator tests and pathology were pooled by assuming a fixed effect. Limits of agreement (LOA) were estimated from a pooled variance by assuming equal variance of the differences across studies. RESULTS: Data were extracted from 19 studies (958 patients). The pooled MD between MRI and pathology from six studies was 0.1 cm (95% LOA: -4.2 to 4.4 cm). Similar overestimation for MRI (MD: 0.1 cm) and ultrasound (US) (MD: 0.1 cm) was observed, with comparable LOA (two studies). Overestimation was lower for MRI (MD: 0.1 cm) than mammography (MD: 0.4 cm; two studies). Overestimation by MRI (MD: 0.1 cm) was smaller than underestimation by clinical examination (MD: -0.3 cm). The LOA for mammography and clinical examination were wider than that for MRI. Percentage agreement between MRI and pathology was greater than that of comparator tests (six studies). The range of Pearson's/Spearman's correlations was wide (0.21-0.92; 16 studies). Inconsistencies between MDs, percentage agreement and correlations were common. CONCLUSION: Magnetic resonance imaging appears to slightly overestimate pathologic size, but measurement errors may be large enough to be clinically significant. Comparable performance by US was observed, but agreement with pathology was poorer for mammography and clinical examination. Percentage agreement can provide supplementary information to MDs and LOA, but Pearson's/Spearman's correlation does not provide evidence of agreement and should be avoided. Further comparisons of MRI and other tests using the recommended methods are warranted.


Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Neoplasias da Mama/tratamento farmacológico , Neoplasias da Mama/patologia , Imageamento por Ressonância Magnética/métodos , Adulto , Neoplasias da Mama/diagnóstico por imagem , Quimioterapia Adjuvante , Estudos de Coortes , Feminino , Humanos , Pessoa de Meia-Idade , Terapia Neoadjuvante , Invasividade Neoplásica , Radiografia , Carga Tumoral
19.
Br J Cancer ; 108(8): 1579-86, 2013 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-23579217

RESUMO

BACKGROUND: There is no consensus on the most effective strategy (mammography or magnetic resonance imaging (MRI)) for screening women with BRCA1 or BRCA2 mutations. The effectiveness and cost-effectiveness of the Dutch, UK and US screening strategies, which involve mammography and MRI at different ages and intervals were evaluated in high-risk women with BRCA1 or BRCA2 mutations. METHODS: Into a validated simulation screening model, outcomes and cost parameters were integrated from published and cancer registry data. Main outcomes were life-years gained and incremental cost-effectiveness ratios. The simulation was situated in the Netherlands as well as in the United Kingdom, comparing the Dutch, UK and US strategies with the population screening as a reference. A discount rate of 3% was applied to both costs and health benefits. RESULTS: In terms of life-years gained, the strategies from least to most cost-effective were the UK, Dutch and US screening strategy, respectively. However, the differences were small. Applying the US strategy in the Netherlands, the costs were €43 800 and 68 800 for an additional life-year gained for BRCA1 and BRCA2, respectively. At a threshold of €20 000 per life-year gained, implementing the US strategy in the Netherlands has a very low probability of being cost-effective. Stepping back to the less-effective UK strategy would save relatively little in costs and results in life-years lost. When implementing the screening strategies in the United Kingdom, the Dutch, as well as the US screening strategy have a high probability of being cost-effective. CONCLUSION: From a cost-effectiveness perspective, the Dutch screening strategy is preferred for screening high-risk women in the Netherlands as well as in the United Kingdom.


Assuntos
Neoplasias da Mama/diagnóstico , Neoplasias da Mama/genética , Detecção Precoce de Câncer/métodos , Genes BRCA1 , Genes BRCA2 , Mutação , Adulto , Idoso , Neoplasias da Mama/economia , Análise Custo-Benefício , Detecção Precoce de Câncer/economia , Feminino , Predisposição Genética para Doença , Humanos , Imageamento por Ressonância Magnética/economia , Imageamento por Ressonância Magnética/métodos , Mamografia/economia , Mamografia/métodos , Pessoa de Meia-Idade , Modelos Econômicos , Modelos Estatísticos , Países Baixos , Reino Unido , Estados Unidos
20.
Br J Radiol ; 85(1020): e1174-8, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23175484

RESUMO

OBJECTIVE: The aim of this study was to supplement the paucity of information available on logistical aspects of the application of three-dimensional (3D) mammography in breast screening. METHODS: We prospectively examined the effect on radiographers' and radiologists' workload of implementing 3D mammography in screening by comparing image acquisition time and screen-reading time for two-dimensional (2D) mammography with that of combined 2D+3D mammography. Radiologists' accuracy was also calculated. RESULTS: Average acquisition time (measured from start of first-view breast positioning to compression release at completion of last view) for seven radiographers, based on 20 screening examinations, was longer for 2D+3D (4 min 3 s; range 3 min 53 s-4 min 18 s) than 2D mammography (3 min 13 s; range 3 min 0 s-3 min 26 s; p<0.01). Average radiologists' reading time per screening examination (three radiologists reading case-mix of 100 screens: 10 cancers, 90 controls) was longer for 2D+3D (77 s; range 60-90 s) than for 2D mammography (33 s; range 25-46 s; p<0.01). 2D+3D screen-reading was associated with detection of more cancers and with substantially fewer recalls than 2D mammography alone. CONCLUSION: Relative to standard 2D mammography, combined 2D+3D mammography prolongs image acquisition time and screen-reading time (at initial implementation), and appears to be associated with improved screening accuracy. ADVANCES IN KNOWLEDGE: These findings provide relevant information to guide larger trials of integrated 3D mammography (2D+3D) and its potential implementation into screening practice.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Competência Clínica/normas , Detecção Precoce de Câncer/métodos , Imageamento Tridimensional/normas , Mamografia/normas , Radiologia/normas , Carga de Trabalho , Estudos de Casos e Controles , Feminino , Humanos , Imageamento Tridimensional/métodos , Mamografia/métodos , Estudos Prospectivos , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...